Boiler mact compliance at Boise Wallula case study
Courtesy of Lundberg, LLC
Lundberg Helped Boise Wallula Reduce Emissions with a Geoenergy E-Tube WET ESP
A major pulp and paper supplier in the northwest was in need of a cost effective solution to reduce their particulate emissions from a biomass fired boiler. Lundberg provided a Geoenergy Wet ESP to meet their needs. The result was a ten fold decrease in particulate emissions and they now meet current Boiler MACT particulate emissions standards.
Problem
In 2005 a major pulp and paper supplier required air pollution control equipment that would reduce particulate emissions from their biomass wet stoker boiler. The boiler was already equipped with a wet scrubber, and the client was in search of a simple reliable solution to further reduce emissions.
Industry
Pulp and Paper
Objective
Meet Boiler MACT particulate reduction requirements
Solution
Geoenergy E-Tube wet ESP
Results
- Met Boiler MACT particulate requirements
- High uptime and low maintenance costs
- No boiler fan modifications required
- Minimal process downtime required for installation.
Customer comments
No comments were found for Boiler mact compliance at Boise Wallula case study. Be the first to comment!