Comparison of EN 14078 and ASTM D7371 infrared biodiesel methods
Infrared (IR) analysis is the most widely used measurement technology for measuring biodiesel in diesel. Both EN 14078 and ASTM D7371 methods use infrared as the analytical method and more specifically FTIR (Fourier Transform Infrared) spectroscopy. Infrared is a common spectroscopic technique used for quantitative and qualitative analysis. In the biodiesel measurement, the fatty acid methyl ...
-
The Effect of Feedstocks on InfraRed Blend Measurements
IR can be a simple, effective way to measure biodiesel blend ratios from a variety of feedstocks BY SANDRA RINTOUL With biodiesel hitting a new production record of 823 million gallons through October and expected to reach 1.28 billion by 2013, more biodiesel will ultimately be blended into our diesel fuel. This boom in production has opened the doors to a number of potential biodiesel ...
-
Get comparable ASTM/EN data for biodiesel blend while saving time and money
If you need to verity how much biodiesel is in a diesel fuel, sending a sample off to a laboratory can take several days to get an answer. This can add unnecessary delays if a truck has just been loaded for a delivery, but must wait for the lab result. The best solution is to have an on-site test where the fuel is loaded or delivered. The two most widely used analytical methods for measuring the ...
-
Biofuels blend measurements with portable mid-infrared analyzers
Globally, governments are putting more emphasis on sustainable energy sources and are creating energy policies that promote the production and use of biofuels. With the Renewable Fuels Standard-2 (RFS-2), the United States set biofuels blending volumes to 12.95 billion gallons (49.0 billion liters) for 2010, increasing to 36 billion gallons (136 billion liters) by 2022. With similar mandates or ...
-
Meeting the Challenges of Biodiesel Blend Measurements with Portable Mid-Infrared Analyzers - Case study
In a published paper on biodiesel blend quality submitted by the National Renewable Energy Laboratory1, the chief problem found with biodiesel blends was inaccurate blend ratios. Retail customers and fleet managers do not typically worry about whether the blend ratio is correct until a problem occurs. For fleet managers, an incorrect blend can mean a total shutdown of operations. On the ...
-
InfraSpec VFA-IR Spectrometer for Biodiesel Blend Measurements
Synopsis: Simple, yet powerful, filter-based IR spectrometers are ideal for compliance to the new ASTM 7861 test method for accurately measuring biodiesel blend ratios. The Wilks InfraSpec analyzer was the instrument used to develop and validate this method and thus is the industry standard for field measurement of FAME (Fatty Acid Methyl Ester) blend percentages. Introduction: Biodiesel is a ...