waste gas Articles
-
Ghost Series AB 200 x 20` Enclosed Combustors - Case Study # 170102
Project Details Location: Mid-Continent Heat Capacity: 18.4 MM BTU/hr Inlet Pressure (AP): 2 psig Aereon's Ghost Series enclosed combustors are designed to burn waste gas in a smokeless application. This customer in the Mid-Continent region is using 6 combustors as an emergency backup to the sales line. Waste gas is supplied through a manifold system. The small footprint and simple ...
-
Very large waste gas volumes with low contaminant concentration - Case Study
Example: Electronics industry Similar tasks: Paint shops, spectacle coating, coating on the inside of cans The electronic industry produces semiconductors that generate very large waste gas streams that are only slightly contaminated. These waste gas streams are purified in rotary adsorbers. The continuous regeneration of the adsorbers generates highly contaminated but much lower waste gas ...
-
Several waste gas streams: Highly contaminated oxygen-free waste gas, and medium waste gas stream - Case Study
Example: Chemical industry Similar tasks: Petrochemical and pharmaceutical industries A producer of synthetic rubber creates a medium waste gas as well as a highly contaminated oxygen-free waste gas which contains primarily low hydrocarbons. The main waste gas stream is purified in a regenerative thermal oxidiser (RTO), while the oxygen-free waste gas passes through the CTP burner in the RTO ...
-
HP1500/HP3000 Flares - Case Study #170101
Project Details Location: Pecos, TX Flow Rate : 5 MMscfd Inlet Pressure(ΔP): 20psi Aereon’s HP series flares are used to burn high pressure waste gas at multiple flow rates. Customer used multiple flares along with a combustor to be able to accommodate high and low pressures coming from multiple sources. The integral skid design reduces installation costs and has a minimal ...
-
Several waste gas streams: Short, high concentration peaks and a constant medium concentration - Case Study
Example: Production of synthetic resin Similar tasks: Chemical industry, batch processes in the pharmaceutical and plastics industry The production of high quality synthetic resin for marine paints and varnishes, coatings and repair materials, involves different waste gas streams. In addition to waste gas with a medium level of contamination, there is also a highly contaminated waste gas which ...
-
Project Tank Vapors - Case Study
Project Overview: In 2015 Questor was selected to provide emissions control for a truck loading and tank vapors at a Shell oil battery in Alberta, Canada. The waste gas stream consists primarily of rich gasses, ethane (~19 mol%), propane (~35 mol%), butane (~24 mol%) and remaining hydrocarbons, ~35 mscf/d of fuel gas is required to draw the low pressure waste gas stream into the thermal oxidizer ...
-
Cyclone Series Air Assisted Flare With Model 850 Flamex Ignition System - Case Study #170604
Project Details Location: Freeport, TX Max Inlet Flow Rate: 12,765 lbs/hr Smokeless Flow Rate: 0 ‐ 100% of Max Flow, Meets Ringelmann1 Molecular Weight: 58.30 Flare Gas LHV: 3013 Btu/SCF Required Inlet Pressure: 12 psig Inlet Temperature: 80 F Aereon’s Air assist flare system with model 850 Flamexignition system is used in this case in Freeport, TX to dispose of heavier ...
-
Exergy evaluation of emitted waste gas and fuel consumption in food delivery process
Food delivery from restaurants and fast food shops by motorbikes is one of the major modes of its distribution. We aim to investigate the environmental impact of food delivery process by motorbikes. The environmental impact was described from the viewpoint of waste gas emission and emission exergy. A university campus was selected as the test site. We extracted the number of food delivery, ...
-
Momentum Series HP-1500 (4” X 25’) High Pressure Flare - Case Study #170206
PROJECT DETAILS Location:Permian Basin Flow Rate HP: 1.7 MMSCFD HP Inlet Pressure (ΔP): 50-75 PSIG Smokeless %: 100% Pilot & Controls: ProFire1300 Solar Package: No ElectricyRequired Installed Year:2017 Aereon’s Momentum Series, Unassisted Flare is used to burn off waste natural gas from a high-pressure separator. The technology used for this flare design allows for 100% ...
-
Tronox Namakwa sands furnace Gas CHP Plant - Case Study
Tronox is the largest fully integrated producer of titanium ore and titanium dioxide in the world. The Tronox Mineral Sands cogeneration power generation plant, located in the Western Cape, uses the waste gas from two open arc DC furnaces as an energy source. The gas engine power plant operates on waste gas produced by titanium melting. The facility consists of 8 of GE’s JMS620GS-SL ...
-
Ghost Series AB-200 x 20’ Enclosed Flare - Case Study #170302
PROJECT DETAILS Location: Somerset, CO Heat Capacity: 18.4 MMBTU/hr Inlet Pressure (ΔP): 6” WC Heating Value: ~300 BTU/SCF AB-200: 490 MSCFD Carbon Credits: $6000/ day Installed Year: 2017 Aereon’s Ghost series enclosed flare is pictured here on a Coal Bed Methane operation in Somerset Colorado. Harmful Methane was being vented to the atmosphere from an abandoned ...
-
Preventing Gas Evaporation with Fluoropolymers
Do you find that you’re going through your gas quicker than you thought? It might not be something in your head. You may have an issue with gas evaporation. While gas evaporation is usually more of a problem in the hot summer months, it still does occur in the colder months as well, which means you will need to safeguard against it at all costs. If you want to save money at the pump now ...
By Fluorostore
-
Thermal waste gas purification of siliceous organic compounds - Case Study
Example: Electrical industry Similar tasks: Electronic industry, Coating, Waste management When coating mica insulation materials, peaks of high contamination occur. The exhaust air containing organic compounds generates excess heat when oxidised in the regenerative thermal oxidiser (RTO). The properties of ceramic honeycomb blocks allow for the storage of that excess heat, for the production of ...
-
Optimizing The Operation And Material Selection For Fluorinated Waste Gas Incineration
A thermal oxidizer system is used by Honeywell Specialty Chemicals to reduce organic and acid gas emissions from their fluoro-products plant. The thermal oxidizer system consists of a multi-gas fired vortex burner mounted on a vertical residence chamber. ...
-
First WESP - waste gas cleaning system for China wood based panel industry
The official signing of the contract with the leading DARE Wood Based Panel Group in Danyang (near Nanjing) took place on November 23th, 2014 in the presence of the Environment Agency. This is emission control system has been developed by EWK and is an Europe wide "State of Art" system in the wood based panel and pellet industry. DARE has taken a major step in protecting the environment. During ...
-
Decomposition of benzene by non-thermal plasma processing: Photocatalyst and ozone effect
Plasma technology has some shortcomings, such as higher energy consumption and byproducts produced in the reaction process. However non-thermal plasma associated with catalyst can resolve these problems. Therefore this kind of technology was paied more and more attention to treat waste gas. A hybrid system comprising a non-thermal plasma reactor and nanometer titanium dioxide catalyst was used ...
-
Ghost Series AB-20 x 20’ Enclosed Combustor - Case Study #170205
PROJECT DETAILS Location: Permian Basin Flow Rate LP: 20.0 MSCFD LP Inlet Pressure (ΔP): 4 oz/in.2 Smokeless %: 100% Pilot & Controls: ProFire2100 Solar Package: No Electricity Required Installed Year: 2017 Aereon’sGhost Series Enclosed Combustor (EPA Certified for Quad O Compliance) is used to burn off waste natural gas from a low pressure tank. The technology used ...
-
High Temperature Flare (HTF) - Case Study #170605
PROJECT DETAILS Location: Beaumont, TX Product Loaded: Gasoline Max RVP: 10.20 PSIA @ 109 °F Max Liquid Loading Rate: 7,000 GPM Max Inlet Flow Rate: 52,087 ACFH Rated Heat Release : 81 MMBTU/HR Max VOC Concentration: 45% Inlet Temperature: 100°F MAX Aereon’s Abutec HTF (High Temperature Flare) is designed to maintain high destruction efficiency and removal efficiency, ...
-
Ghost Series & Momentum Series Combo AB-20 Combustor / HP-1500 Flare - Case Study #170203
Project Details Location: Permian Basin Flow Rate HP: 1.5 MMSCFD HP Inlet Pressure (ΔP): 50-75 PSIG Flow Rate LP: 20.0 MSCFD LP Inlet Pressure (ΔP): 4 oz/in.2 Smokeless %: 100% Pilot & Controls: ProFire 2100 & 1300 Solar Package: No Electricity Required Installed Year: 2017Installed Year: 2017 Aereon’s Ghost/Momentum Combo Package (EPA Certified for Quad O ...
-
Energy and exergy analysis of a combined transcritical CO2 compression refrigeration and single effect H2O-LiBr vapour absorption system
A refrigeration system is conceived and analysed wherein high grade waste heat from the gas cooler of a TCRS is utilised to operate a single effect H2O-LiBr VARS. A simulation program is developed for computation of optimum gas cooler pressure of TCRS. The COP and ? ex for individual TCRS and VARS as well as for the combined system have been evaluated. For different values of evaporator ...
Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you