Municipal Incinerator (Slovenia) - Case Study
Courtesy of Glosfume
WID and BREF-compliant EU showcase municipal incinerator in Slovenia
During 2008 Glosfume was asked to supply a ceramic filter which could achieve emission levels below WID. Representing the state-of-the-art in high temperature filtration design rated at 70,589 Am3/hr @ 250 °C. The installation complies both Waste Incineration Directive (WID) and BAT Reference note (BREF) compliant and will be used by the EU as a reference plant.
- Installation date: 2008
- Location: Republic of Slovenia
- Filter unit: HTMC12 (400)
- Filtration area: 912 m2
- Operating temperature: 250 °C
- Dry scrubbing: sodium bicarbonate injection/activated carbon injection
Typical emission levels:
- Particulate: 0.8 mg/Nm3
- HCl: 6.5 mg/Nm3
- SO2: 1.8 mg/Nm3
- NOx: < 200 mg/Nm3
- HF: 0.4 mg/Nm3
- Dioxins: 0.05 ng/Nm3
- Heavy Metals: < 0.5 mg/Nm3
Customer comments