power-factor Downloads
307 downloads found
Data sheet Power Factor ...
The electricity usually travel very long distance from the generating plants to the customers. To ensure all customers get acceptable voltage levels considering the voltage drop and loading on the grid net work, the grid networks typically supply electricity voltage at high end of the range which is higher than required by most equipment to work at best efficiency. This can result in over voltage ...
Energy Ace recommends the use of Power Factor Correction as industrial processes vary wildly across different businesses. What they do have in common is that they consume large amounts of energy in carrying out their processes, mainly through the use of motors and ...
All-in-one power quality product for active harmonic mitigation and power factor correction ...
Transducer for Active, Apparent, Reactive Power, Phase Angle and Power ...
NF20 is power factor controller for reactive power compensation. It controls external reactive power element (capacitor) to meet reactive power demand of the load. This reduces burden on source to supply additional reactive current. Precise and fast measurements are useful tool for system analysis. Powerful protection function protects system and switching element in case of system faults. ...
3Ph in/3Ph out Online UPS with high power factor 0.9, use AC-DC-AC converter,support 6 units ups parallel operation,EPO/RS232/Bypass available. 6pulse or 12 pulse ...
Rated Speed : 1500 RPM -50 Hz. Phase : 3. Power Factor : ...
3Ph in 3Ph out Online UPS,1.0 power factor output, online capacity expansion and maintenance,4 units UPS for parallel working up to 1200KVA,LCD display 13 ...
GE 230V series is particularly suitable for three-phase networks with low harmonic distortion in current. These equipment guarantee an accurate power factor correction, thanks to a multistep design that effectively divides the power. In addition, on the G6E cabinet, all the capacitors banks are assembled on racks, easily removable from the front of the panel, for simple management and ...
Ratings at 0.8 power factor. Ambient reference conditions: 1,000 mbar, 27ºC, 30% relative humidity. Standby Power Standby duty, operation under variable load, without over load. Prime Power-Continuous duty operation, under variable load 24/24h-10% over load permissible 1 hour/12 ...
The transducer SINEAX G536 (Fig. 1) measures the phase angle or power factor between current and voltage of a single or 3-phase balanced network having a sine wave ...
In both process and bias applications, the Advanced Energy (AE) Pinnacle® 3000 DC power supply provides the highest efficiency and power factor available, resulting in the lowest operating and installed cost in the industry. ...
Power factor correction denotes the introduction of capacitors to an inefficient system (basically the shock absorber of the power system). The capacitors, whether static or automated, reduce current and improve the power factor of a system, bringing it as close to unity as possible. Power ...
Ratings at 0.8 power factor. Ambient reference conditions: 1,000 mbar, 27ºC, 30% relative humidity. Standby Power Standby duty, operation under variable load, without over load. Prime Power-Continuous duty operation, under variable load 24/24h-10% over load permissible 1 hour/12 ...