steam-traps Downloads
54 downloads found
This installation sheet covers the installation and maintenance of the CDS and CDH Series Sanitary steam ...
The Delta DSV-UC Venturi Steam Trap with universal connector has been specifically designed for trace heating and line drainage applications as well as small to medium heat exchanger applications. The two-bolt universal connector system is a permanent replacement venturi orifice steam trap that will fit onto any standard ...
Save energy costs by non-invasively monitoring your existing steam traps to remotely detect early failures Steam trap failures cause you to lose money. Leaking traps increase steam costs and blocked traps can cause pipe damage.Instead of time-consuming manual audits, the ...
(Mod. 043).— Sealing surfaces treated and balanced, making them extremely tightness, even exceeding DIN-3230 requeriments.Page 3.— All steam traps undergo throrough testing.— Each component is numbered, registered and inspected. ...
The DSV Venturi Steam Traps are designed for multipurpose applications from line drainage, trace heating, through to medium heat exchanger applications. ...
16• Discharge with virtually no banking-up• Robust, insensitive regulator• Installation in any position• Max. admissible back pressure 80 % of the upstream pressureFeatures of the DK seriesApplicationTypeDK 45 Rhombusline body with enclosed, weather-resistant regulator for discharging steam lines and tracing systems without banking-up of condensateDK 47-L Compact ...
ByGESTRA
Factory-set closing pressure 0.8 bar.UBK 46 Steam trap with adjustable condensate discharge temperature, thereby suppressing the formation of flash steam. With Y-type strainer.SMK 22, SMK 22-51 Steam trap for SIP applications.MK 20 Steam trap for low-pressure ...
ByGESTRA
22Steam Trap Units for UNIVERSAL (Swivel) ConnectorsBK 36A/7MK 36A/71Features• Maintenance-free, ultra-compact steam traps made from stainless steel, suitable for all UNIVERSAL (Swivel) connectors• Installation in any position• Integrated spiral wound gasket for connector• Only two screws make for a quick and easy installation• ...
ByGESTRA
Steam has two components: 1] the latent heat useful in process for Heat transfer, and 2] the Sensible heat in the form of condensate having only the heat content not useful in process, rather hindering Heat transfer and causing damage to piping equipment due to its presence. Hence, there is need to remove condensate and trapped steam. This is done by Steam trap. ...
na olanak sa¤layan yatay pozisyonda olmal?d?r.The steam trap must be fitted with the float arm inhorizontal plane so that the float rises and falls verticallyin the body.SK 55ÞAMANDIRALI KONDENSTOPDüßük Tahliye KapasiteliTermostatik Hava TahliyeliFLOAT TRAPFor Low Discharge CapacityWith Thermostatic Air VentÖzellikler / Main FeaturesAYVAZ SK 55 ...
ByAyvaz
The Delta 25DSV Venturi Orifice Steam Trap is designed for multipurpose applications from line drainage and trace heating, through to medium to large process applications. The25DSV has an integrated strainer and an in-line removable orifice insert. The body of the 25DSV does not have to be removed from the line for maintenance purposes. Access to the insert orifice and strainer is through the ...
—Stainless SteelStainless SteelFluorine ResinStainless SteelStainless SteelStainless SteelStainless SteelStainless SteelStainless SteelStainless SteelStainless SteelCast Stainless SteelStainless SteelStainless Steel — —SUS316L —SUS316L —SUS316LSUS430/304PTFESUS304SUS304SUS304 —SUS304SUS420FSUS416SUS304 —SUS316LSUS303A351 Gr.CF8A351 Gr.CF8AISI316LA351 Gr.CF8AISI316L ...
Ball float steam traps with a level regulator are used to automatically drain power equipment and steam pipe lines of all types. Float regulators which are used in them can be characterised by high water hammer resistance and additional thermal regulators serve to self-vent at start-up. The construction of the steam trap allows for the replacement of regulation parts without dismantling the body ...
önler.A Float through a simple lever mechanism opens orcloses the valve according to the condensate levelinside the trap. The opening is proportional withcondensate rate. It is uneffected by instantaneouspressure changings. These types of steam trapsspecially used where prompt and continious dischargeof condensate is necessary. For such cases float trapsare the ...
ByAyvaz
In industry, one of steam’s most important tasks is to provide thermal energy through condensation, and to heat a variety of media in heat exchangers. During this process, the steam flows through pipes and cools down more and more en route, so that condensate forms here, too. Condensate prevents the optimum transfer of heat, but also, in particular, leads ...
ByGESTRA
The Delta DSV25 Venturi Steam Trap is designed for multipurpose applications from line drainage and trace heating, through to medium to large process applications. The DSV25 has an integrated strainer and an in-line removable venturi insert. The body of the DSV25 does not have to be removed from the line for maintenance purposes. Access to the insert and strainers is through the top and bottom ...
Thermodynamic steam trap with for the extraction of steam condensates. For use in: steam piping, irons, laundries, tanks and vessels with condensate discharge, multiple plate presses, vulcanizing autoclaves, pressure reduction equipment, etc. ...
Thermodynamic steam trap with filter for the extraction of steam condensates. For use in: steam piping, irons, laundries, tanks and vessels with condensate discharge, multiple plate presses, vulcanizing autoclaves, pressure reduction equipment, ...