LAMTEC - Model CMS - Combustion Management System - Tech Sheet
The CMS offers absolute flexibility in the design and control of your combustion control system. CMS incorporates up to 18 analogue inputs (or 9 failsafe), 41 digital outputs, 60 digital inputs, and 10 channels for actuator/drive control depending upon module hardware configuration. Internally, CMS can provide up to 16 individual fuel curves, each controlling up to 10 channels/actuators with 20 ...
-
ACL - Model CSC400-FD - Forced Draft Burner Management System/Combustion Safety Controller - Brochure
The ACL Forced Draft CSC400-FD Combustion Safety Controller is a leading edge burner management system which provides burner ignition and air/fuel ratio control for forced draft burner applications. It monitors three separate thermocouple inputs that can be used for temperature control in process applications such as tanks, heater/treaters, fired separators, line heaters, re-boilers or any other ...
-
Enerac - Model 2000 - Combustion Management System - Brochure
The Enerac 2000 represents a new generation in integrated combustion management. Its unique modular design provides the flexibility to select the optimum combustion analyzer to meet every need. For the first time, the capabilities of a comprehensive combustion analyzer can be expanded with add-on communication, environmental (NOX-S02), and data modules. All the modules can be purchased with the ...
By Enerac, LLC
-
Lamtec - Model CMS - Combustion Management System Brochure
Modular burner management. Simple operation. From basic to high end applications. Freely configurable I/O (Inputs/Outputs). Language neutral by using symbols and graphics. World wide approvals CE/UL/SIL3 in preparation. CODESYS Soft-PLC integrated. Integrated fault indicator system. Fieldbus on-board. Centralised or distributed module architecture. Compliance with current safety requirements. ...
-
Lamtec - Model FMS - Combustion Management System Brochure
Burner control Electronical compound, up to 5 channels. Universal field bus to interface process control. PC/Modeminterface. Integrated load controller. Integrated leakage test. Integrated CO/O2 controller. Sliding controlled fuel changed. Simultaneous combustion of 2 fuels with variable mixture ratio. Blow out of the burner ...
-
Garioni Naval - Keeler DS - Water Tube Steam Boiler up to 60 t/h - Brochure
www.garioninaval.comwww.euroboilers.comSeries Flows Upto 22 Kg/Sec. (80.0 Tons/Hr.)Pressures Upto 103 Bar(g)Temperature Upto 565 CDSI I I Series Flows Upto 38 Kg/Sec. (135.0 Tons/Hr.)Pressures Upto 103 Bar(g)Temperature Upto 565 CDSI I I XSeries Flows Upto 101 Kg/Sec. (362.8 Tons/Hr.)Pressures Upto 103 Bar(g)Temperature Upto 565 CDSI I I XXRange?Superior natural circulation and operational ...