Energy Monitoring Downloads
-
SINEAX TI807-5 Passive DC Signal Isolator - Data Sheet
Application The signal isolator SINEAX TI 807 serves to electrically insulate the analog DC signal in the range 0...20 mA which depending on version is then converted to a current or voltage signal (0...20 mA or 0...10 V). It operates passively and does not require a separate power supply, but derives the little auxiliary energy it needs from the DC ...
-
SINEAX TI816-5 Passive DC Signal Isolator - Data Sheet
The signal isolator SINEAX TI 816 (Fig. 1) serves to electrically insulate an analog DC signal in the range 0...20 mA which depen- ding on version is then converted to a current or voltage signal (0...20 mA or 0...10 V). It operates passively and does not require a separate power supply, but derives the little auxiliary energy it needs from the DC ...
-
SINEAX SI815-5 Passive DC Signal Isolator - Data Sheet
Application The signal isolator SINEAX SI 815 serves to electrically insulate the 4 to 20 mA input circuit of a 2-wire transmitter. It performs two tasks at the same time. Firstly it provides electrical insulation and secondly it conducts the power supply needed for measurement to the 2-wire transmitter without injecting into the circuit itself. Thus the isolator does not require an power supply ...
-
SMARTCONTROL ECS Energy Control System - Technical Data
Application The multitalented SMARTCONTROL expands the Energy Control System (ECS), which is widespread in industry and building ...
-
SINEAX - Model U554 - Transducer for AC Voltage with Different Characteristics - Datasheet
The transducer SINEAX U 554 (Fig. 1) converts a sinusoidal or a distorted AC voltage into a load independent DC current or a load independent DC voltage proportional to the measured value. Depending on the version, part of the measuring range of interest may be amplified at the beginning or end. The section of no or minor interest is suppressed. A live zero output signal is possible with all ...
-
SINEAX SI815-1 Passive DC Signal Isolator - Data Sheet
Application The signal isolator SINEAX SI 815 serves to electrically insulate the 4 to 20 mA input circuit of a 2-wire transmitter. It performs two tasks at the same time. Firstly it provides electrical insulation and secondly it conducts the power supply needed for measurement to the 2-wire transmitter without injecting into the circuit itself. Thus the isolator does not require an power supply ...
-
PROTOR-mobile - Portable Vibration Condition Monitoring - Datasheet
PROTOR-Mobile is the ideal investigative tool for condition monitoring of rotating machinery. It provides the same extensive facilities as a standard PROTOR system, but as a portable unit, rugged enough to withstand a typical Power Station ...
-
SINEAX TVD825 Isolating Amplifier DC-Signal Duplicator (Current/Voltage) - Data Sheet
The purpose of the signal converter / duplicator SINEAX TVD825 is to electrically insulate input and output signals, respectively to amplify and / or change the signal level or type (current or voltage) of the input ...
-
SINEAX TV815 DC-Signal Converter (Current/Voltage) - Data Sheet
The purpose of the signal converter SINEAX TV815 is to electrically insulate input and output signals, respectively to amplify and/or change the signal level or type (current or voltage) of the input ...
-
LINAX PQ3000 Transparent Monitoring of Power Quality and Energy Consumption - Operating Instructions
The LINAX PQ3000 combines the characteristics of a power quality measurement device with functions for comprehensive energy consumption and condition monitoring. It stands out by the display quality and intuitive ...
-
RJM - Model RD 7000 - Precision Cable Locators Brochure
The RD7100 contains advanced locating technologies from Radiodetection. RD7100, Radiodetection’s industry-specific range of underground cable locator equipment, contains advanced locating technologies with each model optimized for the challenges of locating a particular buried utility. ...
-
RJM - Model RD8100 - Precision Cable Locators Brochure
Radiodetection RD8100 Locator Range Keeping you on the Right Line.New range of locators delivering optimized precision for the damage prevention ...
-
SINEAX DME 424/442 Programmable Multi-Transducers - Data Sheet
Application The SINEAX DME 4 series of multi-transducers (Fig. 1) simultaneously measure several variables of an electric power system and process them to produce 2 resp. 4 analog output signals. 2 or 4 digital outputs are available for signalling limits or energy metering. For two of the limit outputs up to three measurands can be logically ...
-
SINEAX A 230 / A 230s Multifunctional Power Monitor with System Analysis - Data Sheet
Benefits System and load analysis by measurement of harmonics, THD, asymmetry, comprehensive average and max./min. values High functionality in a compact form (depth 46 mm) low costs for purchase, engineering and installation 4-digit, 14 mm high LED display enables reliable reading from a distance, especially in dark rooms User configurable display simplifies local operation ...
-
SINEAX DME442 Programmable Multi-Transducer - Data Sheet
Application The SINEAX DME 4 series of multi-transducers (Fig. 1) simultaneously measure several variables of an electric power system and process them to produce 2 resp. 4 analog output signals. 2 or 4 digital outputs are available for signalling limits or energy metering. For two of the limit outputs up to three measurands can be logically ...
-
SINEAX A 210 / A 220 Multifunctional Power Monitor - Data Sheet
Application The A 210/A 220 power measuring instrument is suitable for control panel mounting and measures all the important measurands in 3-phase and single-phase ...
-
A2000 Multifunctional Power Meter - Technical Data
Applications The measuring instrument is used for the analysis of alternating current systems, in particular where conventional analog measuring instruments included in distribution systems no longer fulfill continuously growing demands. This is especially applicable where harmonic distortion and harmonics are crucial in addition to current, voltage and ...
-
SIRAX - Model BT5100 - Transducer for AC Voltage - Operating Instructions
This document describes the universal measurement device SIRAX BT5100. It is intended to be used by: Installation personnel and commissioning engineers, service and maintenance personnel, ...
Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you