Carbolite - Model LHT Series - High Temperature Laboratory Oven
The high temperature laboratory oven range LHT comprise three sizes of bench mounted units, each available with maximum operating temperatures of 400°C, 500°C and 600°C.
-
Most popular related searches
Standard Features
- 400øC, 500øC or 600øC maximum operating temperatures
- 30, 60 or 120 litres chamber volumes
- R38 PID controller
- Heavy duty convection fan for good uniformity
- low thermal mass insulation for high energy efficiency
- Corrosion resistant, brushed stainless steel interior
- 2 Multi-position shelves
- Suitable for continuous operation
- Hard wearing, zinc coated & stoved epoxy polyester coated exterior
Options (specify these at time of order):
- Cable entry ports
- Over-temperature protection (recommended to protect valuable contents & for unattended operation)
- A range of sophisticated digital controllers, multi-segment programmers and data loggers is available. These can be fitted with RS232, RS485 or Ethernet communications
- Viewing window (not compatible with stoving & curing option)
- Stoving & curing options for extraction of small volumes of volatile solvents (not compatible with viewing window option)
- Variable speed fan
- Floor stands & stacking frames
- Routine spares kit
- Air exhaust fan (may alter achievable uniformity)
Specifications
LHT 4/30
- Max temp (°C) : 400
- Min temp (°C) : Ambient +60
- Volume (litres) : 30
- Temp stability (°C) : ±0.5
- Temp uniformity (°C) : ±5.0 @ 250°C
- Heat-up time (mins) : 50
- Recovery time (mins) : 10
- Dimensions: Internal H x W x D (mm) : 300 x 300 x 305
- Dimensions: External H x W x D (mm) : 570 x 860 x 550
- Shelves fitted / accepted : 2
- Shelf loading each / total (kg) : 10 / 20
- Max power (W) : 1000
- Weight (kg) : 73
LHT 4/60
- Max temp (°C) : 400
- Min temp (°C) : Ambient +60
- Volume (litres) : 60
- Temp stability (°C) : ±0.5
- Temp uniformity (°C) : ±5.0 @ 250°C
- Heat-up time (mins) : --
- Recovery time (mins) : 16
- Dimensions: Internal H x W x D (mm) : 400 x 400 x 405
- Dimensions: External H x W x D (mm) : 670 x 930 x 670
- Shelves fitted / accepted : 2 / 3
- Shelf loading each / total (kg) : 15 / 30
- Max power (W) : 1500
- Weight (kg) : 99
LHT 4/120
- Max temp (°C) : 400
- Min temp (°C) : Ambient +60
- Volume (litres) : 120
- Temp stability (°C) : ±0.5
- Temp uniformity (°C) : ±5.0 @ 250°C
- Heat-up time (mins) : --
- Recovery time (mins) : 20
- Dimensions: Internal H x W x D (mm) : 645 x 455 x 405
- Dimensions: External H x W x D (mm) : 920 x 1060 x 650
- Shelves fitted / accepted : 2 / 4
- Shelf loading each / total (kg) : 15 / 40
- Max power (W) : 2250
- Weight (kg) : 179
LHT 5/30
- Max temp (°C) : 500
- Min temp (°C) : Ambient +60
- Volume (litres) : 30
- Temp stability (°C) : ±0.5
- Temp uniformity (°C) : ±5.0 @ 250°C
- Heat-up time (mins) : --
- Recovery time (mins) : 10
- Dimensions: Internal H x W x D (mm) : 300 x 300 x 305
- Dimensions: External H x W x D (mm) : 570 x 860 x 550
- Shelves fitted / accepted : 2
- Shelf loading each / total (kg) : 10 / 20
- Max power (W) : 2000
- Weight (kg) : 73
LHT 5/60
- Max temp (°C) : 500
- Min temp (°C) : Ambient +60
- Volume (litres) : 60
- Temp stability (°C) : ±0.5
- Temp uniformity (°C) : ±5.0 @ 250°C
- Heat-up time (mins) : 50
- Recovery time (mins) : 16
- Dimensions: Internal H x W x D (mm) : 400 x 400 x 405
- Dimensions: External H x W x D (mm) : 670 x 930 x 670
- Shelves fitted / accepted : 2 / 3
- Shelf loading each / total (kg) : 15 / 30
- Max power (W) : 2250
- Weight (kg) : 99
LHT 5/120
- Max temp (°C) : 500
- Min temp (°C) : Ambient +60
- Volume (litres) : 120
- Temp stability (°C) : ±0.5
- Temp uniformity (°C) : ±5.0 @ 250°C
- Heat-up time (mins) : --
- Recovery time (mins) : 20
- Dimensions: Internal H x W x D (mm) : 645 x 455 x 405
- Dimensions: External H x W x D (mm) : 920 x 1060 x 650
- Shelves fitted / accepted : 2 / 4
- Shelf loading each / total (kg) : 15 / 40
- Max power (W) : 3000
- Weight (kg) : 179
LHT 6/30
- Max temp (°C) : 600
- Min temp (°C) : Ambient +60
- Volume (litres) : 30
- Temp stability (°C) : ±0.5
- Temp uniformity (°C) : ±5.0 @ 250°C
- Heat-up time (mins) : 70
- Recovery time (mins) : 10
- Dimensions: Internal H x W x D (mm) : 300 x 300 x 305
- Dimensions: External H x W x D (mm) : 570 x 860 x 550
- Shelves fitted / accepted : 2
- Shelf loading each / total (kg) : 10 / 20
- Max power (W) : 2000
- Weight (kg) : 73
LHT 6/60
- Max temp (°C) : 600
- Min temp (°C) : Ambient +60
- Volume (litres) : 60
- Temp stability (°C) : ±0.5
- Temp uniformity (°C) : ±5.0 @ 250°C
- Heat-up time (mins) : --
- Recovery time (mins) : 10*
- Dimensions: Internal H x W x D (mm) : 400 x 400 x 405
- Dimensions: External H x W x D (mm) : 670 x 930 x 670
- Shelves fitted / accepted : 2 / 3
- Shelf loading each / total (kg) : 15 / 30
- Max power (W) : 2250
- Weight (kg) : 99
LHT 6/120
- Max temp (°C) : 600
- Min temp (°C) : Ambient +60
- Volume (litres) : 120
- Temp stability (°C) : ±0.5
- Temp uniformity (°C) : ±5.0 @ 250°C
- Heat-up time (mins) : --
- Recovery time (mins) : --
- Dimensions: Internal H x W x D (mm) : 645 x 455 x 405
- Dimensions: External H x W x D (mm) : 920 x 1060 x 650
- Shelves fitted / accepted : 2 / 4
- Shelf loading each / total (kg) : 15 / 40
- Max power (W) : 3000
- Weight (kg) : 179