Dynapower - Model MPS-250 - 800V Inverter for Behind-the-Meter Energy Storage
From Behind-the-Meter Energy Storage Inverter
For 480 VAC class grid-connected energy storage applications, Dynapower offers the patent-pending MPS-250 800V, a 250 kW inverter from the Micro Power Systems® (MPS) family of behind the meter, four-quadrant, energy storage inverters. Dynapower’s flexible and modular MPS-250 800V optimizes the transfer of energy between a DC energy storage system and a three-phase grid. The MPS provides power conditioning (voltage and frequency support), VAR support, and Standby UPS capabilities for intermittent loads and renewable generation. Systems are available in indoor and outdoor configurations. Multiple units can be paralleled in grid forming mode for microgrid applications. The MPS-250 800V integrates controls and a full complement of switchgear and protection including an AC circuit breaker,
Details
AC contractors, AC and DC Fusing, DC load break contactors, and a DC manual isolation switch into a single, heavy duty industrial enclosure. This offers end users and energy storage integrators a cost advantage when compared to non-integrated systems that require additional add-on protection.
Key Features
- Low Acoustic Footprint
- Parallel Operation in Grid Forming Mode
- Integrated AC Breaker with Shunt Trip
- Integrated DC Disconnect
- Integrated DC Input Fuses
- Cloud-based remote monitoring
Additional Features
TWO MODES OF OPERATION
The patent-pending MPS-250 provides two modes of operation — Grid-Tied (PQ-mode) and Stand-Alone (UF mode). In the Grid-Tied mode, the patent-pending MPS-250 controls the AC output real power (P) and reactive power (Q). In Stand-Alone mode, the system controls the AC output voltage (U) and frequency (F). The system can be started in either mode and the transfer between modes is done dynamically. Advanced controls schemes for multi-unit and microgrid applications are available.
SYSTEM CONTROL
Dynapower’s state of the art control and monitoring platform provides operators with both local and remote operation of the system. In the remote operating mode, a communication link provides autonomous operator control via Ethernet, RS232, or RS485. For local control, Dynapower provides an Operator Interface Terminal (OIT) for error set commands and full system display status.
COMPREHENSIVE SYSTEM MONITORING
The patent-pending MPS-250 provides full system status information including AC output real & reactive power, AC output voltage & frequency and DC battery voltage and DC current readings to the remote operator through feedback signals or through the communication link (via an RTU or PLC). An on-board monitoring system captures error history and grid fault data. System operating information is displayed on the OIT in both local and remote modes of operation.
FAULTS
AC Over Voltage, AC Under Voltage, AC Under Frequency, AC Over Frequency, AC Overload, Over-temperature, DC Over Voltage, DC Over Current, Ground Fault
STANDARDS COMPLIANCE
IEEE 1547, UL 1741 SA, UL Listing
SAFETY FEATURES
Anti-islanding with UL compliant trip points
Input Specifications
- DC Voltage : 580-830 VDC
- Max DC Current : 450 A
- DC Voltage Ripple : <1%
Grid Connection
- AC Line Voltage : 480 VAC 3 Phase, +10%, -12%
- AC Line Frequency : 60 Hz (57 – 60.5 Hz) Field Settable
- Continuous AC Current : 301 A RMS
- Overload AC Current : 320 A RMS
- Continuous AC Power : 250 kW
- Overload AC Power : 300 kW
- Power Factor : 0 – 1.0 Leading or Lagging
- Current Harmonics : IEEE 1547 Compliant, <5% TDD
- Peak Efficiency : 97.5%
Specifications
- Operating Temp : -25 — 50°C, De-rated from 45 to 50°C
- Cooling : Forced Air Cooled
- Rated Max Elevation : 1,000 Meters Full Power; , Up to 3,000 Meters With Derating
- Enclosure : UL 3R (Outdoor)
- Dimensions (HxWxD) : 79” x 41” x 41”
- Weight : 3,500 lbs
Customer reviews
No reviews were found for Dynapower - Model MPS-250 - 800V Inverter for Behind-the-Meter Energy Storage. Be the first to review!