EIT Scorpion - Model HB-5 - Solid-State Electronic Blasting Machine
From Electric Initiators
To Test: Always check blasting circuit with appropriate for blasting test device prior to connecting to Blasting Machine- Before connecting to blasting circuit, depress 'CHARGE' switch until 'READY' light illuminates. While maintaining pressure on 'CHARGE' switch depress 'DETONATE' switch. 'READY' light should extinguish immediately. Caution: Do NOT relax 'CHARGE' switch when depressing 'DETONATE' switch. The dual switch firing circuit assures the blaster's intent to initiate. When 'READY' light fails to illuminate within 5 seconds, replace the Heavy Duty Alkaline 9V battery accessible through the battery cap located on the right side of the unit. Make note to insure proper polarity when replacing battery. To Fire: Connect Blasting Machine to blasting circuit and repeat 'CHARGE' AND 'DETONATE' sequence as in To Test.'
-