Hydro-Mix - Model XT-EX - Flush Mount Digital Microwave Moisture Sensor for Hazardous Locations (Dust)
From Sensor - Hazardous Locations
The Hydro-Mix XT-EX has been designed to measure moisture in flowing bulk solids such as animal feed, grain, rice, pulses and also in liquids. The sensor can be easily installed in ducting, conveying and mixing systems. It is suitable for Zone 20 process environments (Zone 21 external to process). Comprising a single, intelligent unit that contains all on-board functionality including signal processing and averaging, the Hydro-Mix XT-EX precisely measures the moisture content of material passing over the ceramic faceplate. Remote configuration, calibration, diagnostics and firmware upgrades are simple using Hydronix Hydro-Com software. The linear output allows direct integration with any control system using industry standard interfaces.
-
Most popular related searches
Hydro-Mix XT-EX is Certified:
- ATEX: Group II Category 1/2D
- IECEx: Zone 20/21
- ETL: Class II Division 1/2
Features
The Hydro-Mix XT-EX has been designed to measure moisture in flowing bulk solids such as animal feed, grain, rice, pulses and also in liquids. The sensor can be easily installed in ducting, conveying and mixing systems. It is suitable for Zone 20 process environments (Zone 21 external to process). Certified for use in ATEX, IECEx and NEC/CSA Hazardous Locations (Dust).
- Compact, self-contained unit
- Fixing Plate seal enables installation in dusty or liquid processes or applications
- Certified for installation in Zone 20/21, Class II Div 1/2 environments
- Digital measurement technology provides precise linear moisture measurement with 25 readings per second
- Advanced Digital Signal Processing provides a clear signal with rapid response.
- Fully temperature compensated measurement
- Two analogue outputs, digital RS485 communications and configurable digital inputs/output, alarms
- Remote communication with Hydro-Com software allows configuration of all sensor parameters
- Consistent performance with no need for recalibration for the same material.
The Hydro-Mix XT-EX has been designed to measure m...
The Hydro-Mix XT-EX has been designed to measure moisture in flowing bulk solids such as animal feed, grain, rice, pulses and also in liquids. The sensor can be easily installed in ducting, conveying and mixing systems. It is suitable for Zone 20 process environments (Zone 21 external to process).
Body: 316 Stainless Steel.
Faceplate: Ceramic.
Internal Seals: EPDM FDA Approved O-Rings. Fixing Plate O-Ring: EPDM FDA Approved
The sensor is flush mounted with the internal wall of the installation using the included mounting assembly.
Measurement RangeMoisture: 0-100%, material dependant.
Depth: Approx. 75-100mm, material dependant.
Choice of modes for optimising sensor performance
TemperatureOperating temperature range: -20-60°C Moisture detection range: 0-60°C
Refresh Rate25 times per second
Analogue OutputsTwo configurable 4-20mA or 0-20mA current loop source available for moisture and temperature. May also be converted to 0-10V DC.
Two configurable digital signals available for averaging and alarm functions.
Digital (Serial) CommunicationOpto-Isolated RS485 2-wire port.
RS232, Ethernet and USB converters available. Programming details to access sensor values and parameters are available on request.
Pressure: 1 Bar Vacuum to 5 Bar pressure. Protection: Cable Gland IP68.
Integrated Cable4m, six twisted pairs, 22AWG, 0.35mm2 conductors. Screen braid with 65% minimum coverage plus aluminium/polyester foil. Maximum recommended cable run of 100m.
Power Supply+15V to +30V DC, 4W.
RatingsATEX: Ex II 1/2D
IECEx: Zn 20/21 AEx ta/tb IIIC T200 115°C Da/Db
ETL: Cl II, Div 1/2Grps E, F, G T115°C
Installation and Mounting
The Hydro-Mix XT-EX has been designed to measure moisture in flowing bulk solids such as animal feed, grain, rice, pulses and also in liquids. The sensor can be easily installed in ducting, conveying and mixing systems. It is suitable for Zone 20 process environments (Zone 21 external to process). Certified for use in ATEX, IECEx and NEC/CSA Hazardous Locations (Dust).
Brief details for mounting the Hydro-Mix XT-EX sensor in different types of mixer can be found below, and full details regarding both installation and calibration can be found in the User Guide.
Installation
The electrical cable of this sensor has to be terminated outside of the protected area or within a suitable housing that complies with the relevant protection zone. All connections within the protection zone must be made with the power supply isolated.
Typical Installation
Typical Installation into Mixers, Conveyors and Dryer Outlets
The Hydro-Mix XT-EX can be mounted in many different locations where there is a continuous flow of material across the ceramic faceplate. These include hoppers, ducting, conveyors and mixer systems.