Aereon, part of Cimarron group

Mechanical Vapor Recover Unit (VRU) - Case Study #170504

SHARE
Oct. 24, 2018

Project Details

  • Location: Appalachian Basin /Utica
  • Flow Rate HP: 50 MMSCFD
  • Suction Pressure: 0-12 Oz/in2
  • Discharge Pressure: 200 PSI
  • Electric Drive: 20 HP


Aereon’s Jordan Technologies MeVRU (Electric Drive) is designed with a cold weather package in this application. Flash gas is being captured from three (3) condensate tanks on site and processing the flow through the electric drive MeVRU. The enclosure houses an O2analyzer and a heater. The enclosure is classified as Class 1 Div1 and is designed to meet the customers Safety requirements. The MeVRU as shown here, can be sized to meet a wide range of operating conditions provided by our customers.