Fortuners Advanced Technology Solutions Pvt. Ltd. products
Inverter - UPS
Fortuners - Home UPS Inverter
DSP Based Control Technology which ensure high reliability and fast processing. Multi-function LCD Display for real time parameters status and fault annunciationLike ; Battery voltage, Mains Input Voltage, Output Voltage, Charging Current,Device Temperature, Load power in Watt, Charging mode, ON / OFF status, UPS / Inverter mode selection, Battery type selection. Intelligent Current Controlled Charger ensures that battery full charging andenhances the battery life. High Level of Protection from Overload, Short-circuit, over-temperature, Batterylow and Battery over Voltage, Reverse phase at output. Mains range selectable to INVERTER MODE (110V to 280Vac) or UPS MODE185V to 260Vac. Temperature controlled cooling fan operation to optimize cooling based onloading.
Fortuners - Industrial UPS/Inverter
We offer complete DSP based pure sine wave UPS / Inverter wide range for industrial applications (2.5 KVA to 15 KVA Single Phase and 5 KVA to 30KVA Three Phase) with various battery bank configurations. DSP based Control. TUBULAR/SMF. UPS/INVERTER mode. Intelligent power full grid Charging. Extra Power backup. Unique onsite parameter setting. LCD Display . Pure Sine Wave inverter. Durable design.
MPPT Solar Inverters
Fortuners - Solar Inverter
MPPT Solar Inverters are a next generation solar inverters, High efficiency MPPT technology ensure 20 % to 30% more solar power harvesting from the same capacity solar panels as compare to other technology. Its state-of-the-art design and intelligent control optimizes the yield of all PV installations in residential, offices, rural and other remote installations with very poor or no grid availability.
Fortuners - Solar Inverter
PWM solar inverter cost optimized solar power backup solution for residential, offices, rural and other remote installations with very poor or no grid availability. It consists of PWM based solar charge controller and bi-directional inverter with transformer on the AC side. Transformer based design makes our inverter more rugged and reliable in verse grid input conditions. It provides uninterrupted pure sine wave power at the load output using solar, battery and grid input in customizable order of priority. Latest DSP based control ensures excellent performance and protection from any kind of malfunction. All inverters are ease of operation and Plug ‘N’ Use types of design make it the ideal product for all kinds of users. All Solar UPS can use as a normal inverter incase of solar panels are not connected with the inverter.
Fortuners - Solar Inverter
FORTUNER Solar Hybrid Inverters are a next generation solar inverters, Active front end technology enables it to store the renewable solar energy in the battery as well as export any excess solar power generated, to the grid through net meter, resulting in improved savings at consumer end. In case of High level of flexibility in the form of configurable set points gives an unparalleled level of control over the inverters’ parameters. Customizability of settings makes it the ideal product for solar applications like process industries or Telecom BTS where each site has a different grid condition.
Fortuners - String / On Grid Inverters
String / On Grid Inverters are a next generation solar inverters, active front end Technology enables it to synchronized Renewable Solar Energy to the grid, User can consume that Energy or export to utility power generation company through net meter, resulting in improved savings at consumer end. With the On-Grid inverter no need to connect any Battery Bank, which make this solution cost effective Power saving solution.
Other Products
FORTUNER - Grid Tie Solar Inverter
FORTUNER Grid Tie Solar Inverter is designed to convert Solar Power into utility-grade electricity Power that can be utilized by the home or sold to the local power authority. Grid tie Inverter use high efficiency MPPT technology to ensure that maximum power harvesting from PV array and converted to AC and delivered to the Utility Grid. Grid Tie Inverters are configured to feed into the LT (Low Voltage) utility network with the all safety measure. Anti islanding feature ensure that the inverter switch off when grid power is absent. In order to operate, the Solar Grid Tie Inverter must have grid power available and connected. Wide input voltage range of PV array Voltage gives the flexibility to the user to use a large range of PV modules.
Deep Cycle Solar Batteries
FORTUNER - Sealed Lead-Acid Rechargeable Battery
The FORTUNER sealed lead-acid rechargeable battery is non-spillable and maintenance free. A VRLA (valve regulated lead acid) battery is a starved electrolyte AGM type battery and has a safety valve which prevents excessive build up of gas pressure inside the battery. Valve-regulated lead acid batteries rely upon internal gas recombination to minimize electrolyte loss over the life of the battery, thereby eliminating the need for re-watering. A lead-acid battery has lead positive plates, lead oxide negative plates, and an electrolyte which is a solution of sulfuric acid and distilled water. The plates and the plate separator material between them are arranged in plate packs in plate compartments. VRLA batteries are particularly suited for remote back-up power applications because they do not require the same type of periodic maintenance required by flooded cells. These differing maintenance requirements provide cost savings.
Fortuners - Deep Cycle Solar Batteries
Opzv batteries are standby batteries with tubular plates, especially designed as battery backup power for all industrial applications which demand low-maintenance as well as average and long discharges. The tubular design immobilized GEL and Tubular Plate technology to offer high reliability and performance and guarantees a longer operating life.
Solar Charge Controller
Fortuners - Solar Super Converter
Solar Charger Controller also regulates the rate at which electric current is added to or drawn from batteries. It prevents overcharging, over and variable voltage which if not controlled can reduce battery performance or life span and may pose a safety risk. It also prevents complete drainage (”deep discharge”) of a battery and facilitates controlled discharge thereby maintaining the battery’s longevity. Equipped with Micro controller and Digital Signal Processing (DSP) technology Solar Charger Controller is fully protected against transient over voltage and reverse the current flow, and can charge any type of battery.