A-102 Heaters and Heat Exchanger Coils Brochure
2900 MacArthur Blvd. Northbrook, IL. USA 60062 www.serfilco.com (800) 323 - 5431 BULLETINA-102_NJAN 2011HEATERS andHEAT EXCHANGER COILSHEATERS WITH "SAFEGUARD" CONTROLS PROVIDE SAFE, EFFICIENT AND ECONOMICAL HEATING FOR:PLATING / PICKLING / RINSING ANODIZING / D.I. WATER / DYES ACIDS / ALKALIES / CLEANERS and OTHER AQUEOUS SOLUTIONS LISTED CERTIFIED? HeatersAvailable in a variety of configurations in steel, 304 SS, 316 SS, titanium, quartz, and Teflon®? Thermostat controls and liquid level sensors for safe operation? Heat exchanger coilsMetal coils in 316 SS and titanium; fluoropolymer tube coils THERMAL OVERLOAD PROTECTIONProtector I, II and III-SeriesPROTECTOR I SERIES (Standard on all electric im-mersion heaters)The Protector I over-temperature control system utilizes a heat sensitive fuse to detect overheating conditions. The fuse, placed inside a thermowell, positioned in contact with the heater sheath, will cut power to the heater in the event of a low liquid level.PROTECTOR II AND PROTECTOR III SERIES (Optional - Consult Sales Dept.)The Protector II and Protector III systems provide the same reliable over-temperature protection as the Protector I; however, the control systems feature a heat sensing ther-mostat. Should the tank’s liquid level drop to a preset over-heat point, the thermostat will trip and an audible alarm will sound, as well as cutting power to the heater. This eliminates dangerous operating conditions. After filling the tank, the immersion heater can be quickly made operational by pushing the reset button on the control to restore power. TEFLONSPIRALQUARTZTEFLONFLAT PROFILETHERMOSTATCONTROLMETAL L-SHAPEDLEVELCONTROLMETAL TUBEHEAT EXCHANGER2900 MacArthur Blvd. Northbrook, IL. USA 60062 www.serfilco.com (800) 323 - 5431HEATERS and HEAT EXCHANGER COILSSURFACE LOSSES IN KWfrom open hot water tankTYPICAL HEATER INSTALLATIONBe certain heater is properly connected in compliance with all codes and per instructions which accompany heater.Solution level must always remain above heated zone of heater.Heater should remain at least 2" above sludge at bottom of tank.CAUTION: All heated tanks should be equipped with an emergency automatic shut-off device. Solution level must be at least one inch below junction box. Junction box must not be sub-merged.TO DETERMINE THE HEATING REQUIREMENT OF A TANKCold zoneBracketHeated zoneA-102_NPage 2 Obtain the following information:1. TOTAL CUBIC FEET OF TANK. - Multiply the inside dimensions of the tank (depth x width x length). If the solution is normally 6" below the top of the tank, allow for this when calculating. 2. TOTAL GALLONS OF SOLUTION - Multiply by 7.48 the cubic feet of the tank occupied by solution. 3. AVERAGE AMBIENT (ROOM) TEMPERATURE WHERE TANK IS LOCATED.4. TEMPERATURE LEVEL AT WHICH SOLUTION IS TO BE HELD.5. HEAT-UP TIME DESIRED (HOURS).After this information is known, use the legend at right to make the calculations.A x 1.0* x 8.35 ** x B = __________________3412 x CD x E = __________________Add the results of both calculations. The total is the Kilowatt requirement of the tank. LEGEND* Specific heat of water. Insert specific heat of your solu-tion here. If unavailable, use water value.** Weight of water. Insert specific weight of your solution here. If unavailable, use water value.A = Total gallons of solutionB = Difference between ambient temperature and desired-solution temperature.C = Desired heat-up time (hours).D = Heat loss of tank. Refer to "Surface Losses" chart below.E = Square feet of top of tank (multiply length x width)80° -- 130° .16 180° .5085° .01 135°140°.18.21185°190°.55.6090° .0295° .04 145°150°.24.27195°200°.66.72100° .05105° .065 155°160°.30.34205°210°.80.87110° .09115° .10 165°170°.37.41215°220°.951.04120° .12125° .14 175° .45HEATERWATTSAMPS FOR HEATING LOADSINGLE PHASE THREE PHASE (BALANCED)120V 208V 230V 240V 460V 480V 208V 230V 240V 460V 480V1,000 8.4 4.8 4.4 4.2 2.2 2.1 2.8 2.6 2.5 1.3 1.22,000 16.7 9.7 8.7 8.4 4.4 4.2 5.6 5.1 4.9 2.6 2.53,000 25.0 14.5 13.1 12.5 6.6 6.3 8.4 7.6 7.3 3.8 3.74,000 33.4 19.3 17.4 16.7 8.7 8.4 11.2 10.1 9.7 5.9 4.96,000 50.0 28.9 26.1 25.0 13.1 12.5 16.7 15.1 14.5 7.6 7.38,000 66.7 38.5 34.8 33.4 17.4 16.7 22.3 20.2 19.3 10.1 9.79,000 75.0 43.3 39.2 37.5 19.6 18.8 25.1 22.7 21.7 11.4 10.912,000 100.0 57.7 52.2 50.0 26.1 25.0 33.4 30.2 29.0 15.1 14.518,000 150.0 86.6 78.3 75.0 39.2 37.5 50.1 45.3 43.4 22.7 21.727,000 225.0 129.9 117.4 112.5 58.7 56.3 75.1 67.9 65.1 34.0 32.636,000 300.0 173.1 156.6 150.0 78.3 75.0 100.1 90.5 86.8 45.3 43.4AMPS FOR SELECTION OF CONTROLS2900 MacArthur Blvd. Northbrook, IL. USA 60062 www.serfilco.com (800) 323 - 5431SINGLE ELEMENT SPIRALL-SHAPED TEFLON IMMERSION HEATERSSINGLE ELEMENT SPIRALOVER - THE - SIDETEFLON IMMERSION HEATERSHOT ZONELENGTH10 watts/square inch nominal.240 volts standard as listed - other voltages available. HOT ZONELENGTHCompatible with most plating tank solutions, inert to acids, anodizing and pickling solutions up to 212°F. temperature. Check Chemical Resistance Chart or with chemical supplier for proper material selection.Replaces alumina or graphite heaters.FEATURES:? Low watt density for long service life.? Non-contaminating Teflon covered stainless steel elements.? PTI or PTLI thermal protection standard.? Grounded internal metal element for safety.? U.L. listed, CSA certified.? Lightweight, non-floating construction.? Standard 3' flexible PVC liquid-tight conduit.? Polypropylene or Teflon guards optional. Consult Sales Dept.? Single phase only? Longer lengths available.? Vapor-tight polypropylene terminal enclosure. * Consult Sales Dept. for other choices.A-102_NPage 3Bottom design for even heating and varying liquid levels. PRICE CODE IDENTIFICATIONPrice Code Number: 79- _ __ __ __ #1 #2 #3 #4 #5_ WATTS VOLTS*HOTZONEInchesVERT.*LENGTHInchesPRICECODENUMBERSHIPWT.lbs.500 240 6 12 79-1009XAA1 61,000 240 8 12 79-1010XAA1 72,000 240 12 18 79-1011XAA1 83,000 240 17 18 79-1012XAA1 134,000 240 20 18 79-1013XAA1 155,000 240 24 18 79-1014XAA1 186,000 240 29 18 79-1015XAA1 218,000 240 37 18 79-1016XAA1 269,000 240 44 18 79-1017XAA1 29WATTS VOLTS*HOTZONEInchesVERT.*LENGTHInchesPRICECODENUMBERSHIPWT.lbs.500 240 5 11 79-1000XAA1 61,000 240 7 11 79-1001XAA1 72,000 240 12 17 79-1002XAA1 83,000 240 16 23 79-1003XAA1 134,000 240 20 29 79-1004XAA1 155,000 240 25 35 79-1005XAA1 186,000 240 29 40 79-1006XAA1 218,000 240 37 47 79-1007XAA1 259,000 240 44 54 79-1008XAA1 28#1 HEATER MATERIAL #2 VOLTAGE #3 PROTECTORConsult Sales Dept. #4 PHASEX = PTFE (Teflon)Q = QuartsP = Plain steelF = 304 stainless steelS = 316 stainless steelT = TitaniumA = 240VB = 480VC = 120VD = 208VE = 415VG = 600VH = 380VReplaceablePIResettablePII or PIIIA = to 1800 F B = 180-2300 FC = 230-3000 FD = to 180OFE = 180-230O FF = 230-300OF1 = 1f3 = 3f#5 OPTIONSBlank = No guardC = w/guardG = Guard onlyJ = Tube onlyE = Element onlyOVER-THE-SIDE HEATERS (OTS) SPIRAL TEFLON®2900 MacArthur Blvd. Northbrook, IL. USA 60062 www.serfilco.com (800) 323 - 5431Compatible with most plating tank solutions, inert to acids, anodizing and pickling solutions up to 212°F. temperature. Check Chemical Resistance Chart or with chemical supplier for proper material selection.Replaces alumina or graphite heaters.FEATURES:? Low watt density for long service life.? Non-contaminating Teflon covered stainless steel element.? PTI or PTLI thermal protection standard? U.L. listed, CSA certified.? Lightweight, non-floating construction.? Vapor-tight polypropylene terminal enclosure.? Standard 3' flexible PVC liquid-tight conduit.? Polypropylene or Teflon guards optional. Consult Sales Dept.? Single phase only? Grounded internal metal element for safety.? Longer vertical lengths available. SINGLE ELEMENT FLATL-SHAPED TEFLON IMMERSION HEATERSSINGLE ELEMENT FLATOVER-THE-SIDE TEFLONHOT ZONELENGTHFlat, low profile design. HOT ZONELENGTH10 watts/square inch nominal240 volts standard as listed - other volt-ages available. Low profile bottom design for evenheating and varying liquid levels.A-102_NPage 4* Consult Sales Dept. for other choices.WATTS VOLTS*HOTZONEInchesVERT.*LENGTHInchesDIA.*inchesPRICECODENUMBERSHIPWT.lbs.500 240 6 14 5 79-1018XAA1 61,000 240 7 14 6 79-1019XAA1 72,000 240 9 17 8 79-1020XAA1 83,000 240 10 23 9 79-1021XAA1 134,000 240 12 29 11 79-1022XAA1 155,000 240 13 35 12 79-1023XAA1 186,000 240 14 40 13 79-1024XAA1 22WATTS VOLTS*HOTZONEInchesVERT.*LENGTHInchesDIA.*inchesPRICECODENUMBERSHIPWT.lbs.500 240 5 12 5 79-1027XAA1 61,000 240 6 12 6 79-1028XAA1 72,000 240 8 18 8 79-1029XAA1 83,000 240 9 18 9 79-1030XAA1 134,000 240 11 18 11 79-1031XAA1 155,000 240 12 18 12 79-1032XAA1 186,000 240 13 18 13 79-1033XAA1 22OVER-THE-SIDE HEATERS (OTS) COIL TEFLON®2900 MacArthur Blvd. Northbrook, IL. USA 60062 www.serfilco.com (800) 323 - 5431Compatible with most plating tank solu-tions, inert to acids, anodizing and pickling olutions up to 212°F. temperature. Check Chemical Resistance Chart or with chemi-cal supplier for proper material selection.Replaces alumina or graphite heaters.FEATURES:? U.L. listed, CSA certified.? Low watt density for long service life.? Non-contaminating Teflon covered stainless steel elements.? PTI thermal protection standard.? Grounded internal metal element for safty.? Lightweight, non-floating construction.? Vapor-tight polypropylene terminal enclosure.? Standard 3' flexible PVC liquid-tight conduit.? Polypropylene or Teflon guards optional. Consult Sales Dept.? Standard 3-phase wiring. Consult Sales Dept. for optional single phase.SIX ELEMENTOVER - THE - SIDE TEFLON IMMERSION HEATERSNINE ELEMENTOVER - THE - SIDE TEFLON IMMERSION HEATERS10 watts/square inch nominal240 volts standard as listed - other voltages available. 3 to 18 kw, 10 watts/square inch nominal 240 volts standard as listed - other voltages available.A-102_NPage 5* Consult Sales Dept. for other choices. LENGTHHOTZONEThermalprotectorThermalprotectorLENGTHHOTZONEWATTS VOLTS*HOTZONEinchesLENGTH*inchesPRICE CODENUMBERSHIPWT. lbs2,000 240 9 17 79-1069XAA3 193,000 240 15 23 79-1070XAA3 224,000 240 21 29 79-1071XAA3 246,000 240 28 35 79-1072XAA3 278,000 240 38 47 79-1073XAA3 3310,000 240 47 59 79-1074XAA3 4012,000 240 55 68 79-1075XAA3 45WATTS VOLTS*HOTZONEinchesLENGTH*inchesPRICE CODENUMBERSHIPWT. lbs3,000 240 9 17 79-1076XAA3 284,500 240 15 23 79-1077XAA3 336,000 240 21 29 79-1078XAA3 369,000 240 28 35 79-1079XAA3 4012,000 240 38 47 79-1080XAA3 4915,000 240 47 59 79-1081XAA3 6018,000 240 55 68 79-1082XAA3 67OVER-THE-SIDE HEATERS (OTS) LOOP TEFLON®2900 MacArthur Blvd. Northbrook, IL. USA 60062 www.serfilco.com (800) 323 - 5431HOTZONELENGTHTRIPLE TUBESINGLE TUBEFor plating tanks, pickling and other acidic aque-ous solutions. Check Chemical Resistance Chart or with chemical supplier for proper material selection.Not for use in hydrofluoric acid or alkaline solutions.FEATURES:? Heavy duty, long lasting construction.? PQI thermal protection standard? Grounded for safety.? U.L. listed, CSA certified.? Vapor-tight polypropylene terminal enclosure.? Standard 3' flexible PVC liquid-tight conduit.? Replaceable elements and quartz tube.? Complete standard heater provided with polypropylene guard, optional Teflon guard available for solutions over 200°F. and chromic acid.26 watts/square inch nominal.240 volts standard as listed, other voltages available. HOTZONELENGTHStandard design consists of three individual single phase heaters, which can be wired delta in the field to achieve a three phase balanced operating system. Individual elements are field replaceable.26 watts/square inch nominal.240 volts standard as listed, other voltages available. A-102_NPage 6Single phase standard. Consult Sales Dept. for optional 3 phase.* Consult Sales Dept. for other choices.WATTS VOLTS*HOT ZONEinchesLENGTH*inchesPRICE CODENUMBERSHIPWT. lbs.500 240 6 10 79-1136QAA1C 91,000 240 7 11 79-1137QAA1C 101,000 240 7 17 79-1138QAA1C 112,000 240 12 17 79-1139QAA1C 112,000 240 12 23 79-1140QAA1C 143,000 240 18 23 79-1141QAA1C 143,000 240 18 29 79-1142QAA1C 173,500 240 21 29 79-1143QAA1C 174,000 240 28 35 79-1144QAA1C 204,000 240 28 41 79-1145QAA1C 235,000 240 33 41 79-1146QAA1C 235,000 240 33 47 79-1147QAA1C 266,000 240 39 47 79-1148QAA1C 266,000 240 39 52 79-1149QAA1C 298,000 240 49 59 79-1150QAA1C 3110,000 240 62 71 79-1151QAA1C 34WATTS VOLTS*HOT ZONEinchesLENGTH*inchesPRICE CODENUMBERSHIPWT. lbs.1,500 240 6 10 79-1152QAA1C 213,000 240 7 11 79-1153QAA1C 223,000 240 7 17 79-1154QAA1C 266,000 240 12 17 79-1155QAA1C 266,000 240 12 23 79-1156QAA1C 309,000 240 18 23 79-1157QAA1C 309,000 240 18 29 79-1158QAA1C 3410,500 240 21 29 79-1159QAA1C 3412,000 240 28 35 79-1160QAA1C 3812,000 240 28 41 79-1161QAA1C 4415,000 240 33 41 79-1162QAA1C 4415,000 240 33 47 79-1163QAA1C 4818,000 240 39 47 79-1164QAA1C 4818,000 240 39 52 79-1165QAA1C 5224,000 240 49 59 79-1166QAA1C 5530,000 240 62 71 79-1167QAA1C 65OVER-THE-SIDE HEATERS (OTS) TUBULAR2900 MacArthur Blvd. Northbrook, IL. USA 60062 www.serfilco.com (800) 323 - 543135 watts/square inch nominal240 volts standard as listed - other voltages available. Single phase standard. Consult Sales Dept. for optional 3 phase.Standard 3' flexible PVC liquid-tight conduit.35 watts/square inch nominal240 volts standard as listed - other voltages available. Standard units consist of a single head with 3' flexible PVC liquid tight conduit.Single phase standard. Consult Sales Dept. for optional 3 phase.A-102_NPage 7HOTZONELENGTHTRIPLE TUBE METAL OVER - THE - SIDE IMMERSION HEATERSFEATURES:? Heavy duty, long lasting construction.? PI thermal protection standard? U.L. listed except plain steel, all CSA certified.? Grounded for safety.? Vapor tight polypropylene terminal enclosure.¹ Consult Sales Dept. for other choices.² For 304SS heater, change S to F in Price Code Number. For titanium heater, change S to T in Price Code Number. For plain steel, change S to P in Price Code Number. For plating tanks, rinse tanks and other aqueous solutions. Check Chemical Re-sistance Chart or with chemical supplier for proper material selection.SINGLE TUBE METAL OVER - THE - SIDE IMMERSION HEATERSWATTS VOLTS1HOTZONEinchesLENGTH1inches316 STAINLESSSTEEL2SHIPWT. lbs.3,000 240 6 11 79-1178SAA1 216,000 240 10 17 79-1179SAA1 309,000 240 16 23 79-1180SAA1 3312,000 240 20 29 79-1181SAA1 3915,000 240 25 35 79-1182SAA1 4518,000 240 30 40 79-1183SAA1 5124,000 240 37 47 79-1184SAA1 6327,000 240 44 54 79-1185SAA1 6930,000 240 49 59 79-1186SAA1 7536,000 240 58 68 79-1187SAA1 84WATTS VOLTS1HOTZONEinchesLENGTH1inches316 STAINLESSSTEEL2SHIPWT. lbs.1,000 240 6 11 79-1168SAA1 72,000 240 10 17 79-1169SAA1 103,000 240 16 23 79-1170SAA1 114,000 240 20 29 79-1171SAA1 135,000 240 25 35 79-1172SAA1 156,000 240 30 40 79-1173SAA1 178,000 240 37 47 79-1174SAA1 239,000 240 44 54 79-1175SAA1 2410,000 240 49 59 79-1176SAA1 2512,000 240 58 68 79-1177SAA1 28OVER-THE-SIDE HEATERS (OTS) TUBULAROVERALLLENGTHTHERMALPROTECTORCOLDZONEHOTZONE2900 MacArthur Blvd. Northbrook, IL. USA 60062 www.serfilco.com (800) 323 - 5431HOT ZONEVERTICALHOT ZONEVERTICALTRIPLE TUBE METAL L-SHAPEDIMMERSION HEATERS(Riser height mea-sured from bottom of sludge leg to bottom of gooseneck. Non-standard lengths are available.)For plating tanks, rinse tanks and other non-sludging aqueous solutions. Check Chemical Resistance Chart or with chemical supplier for proper material selection.FEATURES:? Bottom mount design for even heating and varying solution levels.? Standard 2" sludge legs (longer available).? Heavy duty, long lasting construction.? PLI thermal protection standard? U.L. listed except plain steel, all CSA certified.? Grounded for safety.? Vapor- tight polypropylene terminal enclosure.? Standard 3' flexible PVC liquid-tight conduit.? Optional Teflon flexible riser or straight vertical configuration available.(Consult Sales Dept).SINGLE TUBE METAL L-SHAPEDIMMERSION HEATERS35 watts/square inch nominal 240 volts standard as listed - other voltages available. Single phase standard. Consult Sales Dept. for optional three phase.(Riser height mea-sured from bottom of sludge leg to bottom of gooseneck. Non-standard lengths are available.)¹ For 304SS heater, change S to F in Price Code Number. For titanium heater, change S to T in Price Code Number. For plain steel, change S to P in Price Code Number.35 watts/square inch nominal 240 volts standard as listed - other voltages available. Three phase standard. Consult Sales Dept. for optional single phase.A-102_NPage 8WARNINGELECTRIC IMMERSION HEATERS WILL IGNITE MANY PLASTIC TANKS SUCH AS POLYPROPYLENE AND POLYETHYLENE AND SUBJECT PERSONNEL TO SHOCK HAZARD IF NOT PROPERLY INSTALLED AND MAINTAINED.SHOCK HAZARDIGNITIONSOURCE² Consult Sales Dept. for other choices.WATTS VOLTS2 HORIZ.2inchesVERT.2inches316 STAINLESSSTEEL1SHIPWT. lbs.1,000 240 13 15 79-1208SAA1 102,000 240 17 19 79-1209SAA1 113,000 240 22 25 79-1210SAA1 124,000 240 26 25 79-1211SAA1 135,000 240 31 37 79-1212SAA1 146,000 240 36 50 79-1213SAA1 158,000 240 44 50 79-1214SAA1 189,000 240 50 50 79-1215SAA1 2010,000 240 55 50 79-1216SAA1 2212,000 240 64 50 79-1217SAA1 25WATTS VOLTS2 HORIZ.2inchesVERT.2inches316 STAINLESSSTEEL1SHIPWT. lbs.3,000 240 13 15 79-1218SAA3 306,000 240 17 37 79-1219SAA3 339,000 240 22 37 79-1220SAA3 3612,000 240 26 37 79-1221SAA3 3915,000 240 31 37 79-1222SAA3 4218,000 240 36 50 79-1223SAA3 4524,000 240 44 50 79-1224SAA3 5427,000 240 50 50 79-1225SAA3 6030,000 240 55 50 79-1226SAA3 6636,000 240 64 50 79-1227SAA3 75OVER-THE-SIDE HEATERS (OTS) TUBULAR2900 MacArthur Blvd. Northbrook, IL. USA 60062 www.serfilco.com (800) 323 - 5431Provides digital indication of setpoint and control point temperature.? SIngle setpoint ? 1 or 3 phase controls with 5 ft. FEP sleeved sensor.? -58oF to 302°F temperature range. (-50o to 150°C).? cULus listed.? ±1°F accuracy.? Optional 10 ft. sensor? Large LED readout.A-102_NPage 9For temperature control of heated aqueous solutions. ? Single setpoint? 30°F to 220°F temperature range.? 1 or 3 phase controls with 5 ft. FEP sleeved sensor.? cULus listed. ? ±5°F accuracy.FEP is fluorinated ethylene propylene fluoro polymer.For fluid processing and leak detectionSERIES LC2 Single function probe Designed to control power to im-mersion heater should process solution drop below upper probe.SERIES LC3 Dual function probe Style same as above and also controls power to pump, solenoid valve or other equipment. 10 amp maximum.? Prevents heater burn out from low liquid level.? Designed for use in conductive solu-tions up to 70K OHMS resistance.? PTFE covered stainless steel, titanium, Hastelloy® C or graphite probes available.DIGITAL COMBINATION CONTROLS WITH STEPDOWN TRANSFORMERLIQUID LEVEL SENSOR - SINGLE AND DUAL FUNCTIONNON-INDICATING COMBINATION CONTROLS WITH STEPDOWN TRANSFORMERDIGITAL COMBINATION CONTROLS WITH STEPDOWN TRANSFORMERProvides digital indication of setpoints and control point temperatures. ? Dual setpoints for heat / cool applications.? 1 or 3 phase controls with 10 ft. FEP sleeved sensor.? 0-500°F temperature range (Field selectable 0 - 260oC).? cULus listed? ±.25% accuracy (full span).? Large LED readout.* Designate material selection in Price Code Number and Model Number. S = 316 Stainless steel T = Titanium H = Hastelloy G = Graphite (Not field trimmable)ORDERING INFORMATIONPRICECODE NO.MODELNUMBER VOLTSMAX.AMPSSHIP/ WT.lbs/(Kg.) OPTIONS*79-1660 A79-1660 BDLC 302DLC 304240480 3016(7.5) Add -LT to Price Code Number and Model Number for "less transformer".Transformer must be used at 480 volts.PII or PIII resettable systems (Consult Sales Dept.)*Consult Sales Dept. for other choices79-1661 A79-1661 BDLC 502DLC 504240480 5017(8)79-1662 A79-1662 BDLC 752DLC 754240480 7523(10.5)79-1663 A79-1663 BDLC 902DLC 904240480 9025(11.5)79-1664 A79-1664 BDLC 1202DLC 1204240480 12027(12.5)79-1665 A79-1665 BDLC 1502DLC 1504240480 15033(15)ORDERING INFORMATIONPRICECODE NO.MODELNUMBER VOLTSMAX.AMPSSHIP/ WT.lbs/(Kg.) OPTIONS*79-1670 A79-1670 BDQ 302DQ 304240480 3019(8.5) Add -LT to Price Code Number and Model Number for "less transformer".Transformer must be used at 480 volts.PII or PIII resettable systems (Consult Sales Dept.)*Consult Sales Dept. for other choices79-1671 A79-1671 BDQ 502DQ 504240480 5020(9)79-1672 A79-1672 BDQ 752DQ 754240480 7526(12)79-1673 A79-1673 BDQ 902DQ 904240480 9028(13)79-1674 A79-1674 BDQ 1202DQ 1204240480 12030(13.5)79-1675 A79-1675 BDQ 1502DQ 1504240480 15036(16.5)ORDERING INFORMATIONPRICECODE NO.MODELNUMBER VOLTSMAX.AMPSSHIP/ WT.lbs/(Kg.) OPTIONS*79-1534A79-1534BNR302NR304240480 3015(7) Add -LT to Price Code No. and Model No. for "less transformer".Transformer must be used at 480 volts.Add -H to Price Code No. and Model No. for high temp. model (150°F to 550°F)PII or PIII resettable systems (Consult Sales Dept.)*Consult Sales Dept. for other choices79-1535A79-1535BNR502NR504240480 5016(7.5)79-1536A79-1536BNR752NR754240480 7522(10)79-1537A79-1537BNR902NR904240480 9024(11)79-1538A79-1538BNR1202NR1204240480 12026(12)79-1539A79-1539BNR1502NR1504240480 15032(14.5)ORDERING INFORMATIONLC SERIES — 2 PROBES LC SERIES — 3 PROBESPRICECODE NO.MODELNUMBERPROBE LENGTH(FIELD TRIM)in.PRICECODE NO.MODELNUMBERPROBE LENGTH(FIELD TRIM)in.79-1510 * LC2( * )6 6 79-1517 * LC3( * )6 679-1511 * LC2( * )12 12 79-1518 * LC3( * )12 1279-1512 * LC2( * )18 18 79-1519 * LC3( * )18 1879-1513 * LC2( * )24 24 79-1520 * LC3( * )24 2479-1514 * LC2( * )30 30 79-1521 * LC3( * )30 3079-1515 * LC2( * )36 36 79-1522 * LC3( * )36 3679-1516 * LC2( * )48 48 79-1523 * LC3( * )48 48THERMOSTATS and LIQUID LEVEL SENSORS2900 MacArthur Blvd. Northbrook, IL. USA 60062 www.serfilco.com (800) 323 - 5431HEATERS and HEAT EXCHANGER COILS A-102_NPage 10For a more in-depth analysis of your specific heat requirements, provide the following information and we will gladly size your heat exchanger.Initial temperature________________________________Desired temperature______________________________Tank size: Length _______ Width _______ Height ______Solution depth __________________________________Type of solution to be heated or cooled _______________Production load: Lbs./hr. ________ & load temp. _______Agitation (type) _________________________________Rectifiers: Number ______ Voltage _______ Amp ______Covered or uncovered tank _____________________Insulated tank & tank material ______________________Steam pressure at coil hook-up point ________________Cooling media _____ Inlet temp. ______ Flow rate _____Maximum flow rates, performance curves and pressure drops are determined at the factory for optimum design efficiency. Contact us for perfor-mance data.TEFLON and METALFT.² OF SURFACE AREA REQUIRED(all metals) or30 (Teflon)FT2 OF AREAREQ'D FOR ONE HOUR HEAT-UPConsult Sales Dept. for pressures above 50 lb. for metal and 30 lb. for Teflon.STEAM PRESSURE FACTORSQUICK ESTIMATION (BASED ON STEAM) HEAT-UP STEP 1 Determine gallons in tank. (U.S. Gal. = Tank Width ___" x Length ___" x Depth ___" ÷ 231.) Enter this amount at (A) in Formula 1.STEP 2 Subtract temperature of media to be heated from the tem-perature to which it must be heated. (? Temperature = Desired Temp. ___°F - Initial Temp.___ °F) Enter this amount at (B).STEP 3 Locate your useable steam pressure in Steam Pressure Factor chart and find the factor number. Enter this at (C).STEP 4 Multiply (A) times (B) times (C). Divide the product by 1000. This is the square foot area you require for a one hour heat-up. If more time is available, coil surface area may be reduced by dividing the square foot area by the heat-up time available, up to 4 hours maximum. Formula 1(A) ________ x (B) _______ x (C) ________ ÷ 1,000 = FT2 (GALLONS) (? T) (STEAM FACT.) FORMULA FOR HOT WATER HEATING MEDIASTEP 1 Determine gallons in tank. Enter at (A) in Formula 2.STEP 2 Subtract temperature of media to be heated from the tem-perature to which it must be heated. Enter at (B).STEP 3 Multiply (A) times (B) times 8.33. Enter answer at (C).STEP 4 Subtract the required tank temperature from the temperature of your hot water supply. Enter this figure at (D).STEP 5 Multiply (D) by 100 for all metals or 30 for Teflon and enter answer at (E).STEP 6 Divide (C) by (E) to determine square feet of area required. If more time is available, coil surface area may be reduced by dividing the square foot area by the heat-up time available, up to 4 hours maximum.Formula 2(A)_______ x (B)_______ x 8.33 = ____ (gallons) (?T)___________________________ = (C) = 100 (all metals) (E)or x (D)______________ 30 (Teflon) (Temp. rise required)FORMULA FOR COOLING WITH ANY MEDIUMThis formula assumes that all electrical energy is dissipated in the tank as heat. In more efficient electrochemical conversions, the energy dissipated as heat may be less.STEP 1 Determine watts by multiplying voltage times amperage delivered by the tank rectifier. Multiply this product times 3.412 to determine BTU's. Enter answer at (A) in Formula 3.STEP 2 Subtract cooling liquid temperature from required tank tem-perature. Enter at (B). CAUTION: If this number is less than 15, consult Sales Dept. for assistance in determining proper coil size.STEP 3 Multiply (B) times 100 for all metals or 30 for Teflon and enter answer at (C).STEP 4 Divide (A) by (C) to determine square feet of surface area required.Formula 3(A)____________________(volts x amps x 3.412) = (A) =(B) _______________ x 100 (C)(Req'd. tank temp. minus cooling liquid temp.)Steam PressureAvailable PSI 5 10 15 20 25 50Steam Factorfor Metal .55 .50 .42 .37 .30 .25Steam Factorfor Teflon 2.75 2.50 2.10 1.85 1.50 __HEAT TRANSFER and TUBE & COIL SIZING2900 MacArthur Blvd. Northbrook, IL. USA 60062 www.serfilco.com (800) 323 - 5431A-102_NPage 11SERPENTINE COILS (4-pass)GRID COILSHORIZONTAL GRIDVERTICAL GRID5“12” RisersStandardWidth(corresponds to tankdepth)Length (corresponds to tank wall length)1“O.D.tubing on 11/2” centers1“ NPTNipplesStandardInlet RiseOutlet RiserWhere tank space is at a premium, the gridcoil is only 2" thick. The gridcoil permits full flow-through of solution for efficient heat transfer. Every square inch of surface is an active heat transfer area. Gridcoils can be banked or stacked for greater heat transfer.Standard connections are 1" NPT nipples on 4" centers for serpentine and 5" centers for grids. 1" NPT nipples on variable centers for vertical models.Gridcoils are offered in two styles - horizontal and vertical. However, the horizontal gridcoil is more commonly specified. Also, gridcoils can be operated in shallow solutions - as low as 12". The vertical style is ideal for deep, narrow tanks or wells.Serpentine coils offer lower cost per heating surface area. The design allows them to be installed in tanks with limited space.GRIDCOIL SPECIFICATIONS4“36”Length23”13”riserFor 30”MinimumTank Depth6“¹ For titanium grid coil change 'S' to 'T' in price code no.² Add 'V' to end of price code no. for vertical style. Add 'H' to end of price code for horizontal style.³ Add 'S' to end of price code number for steam. Add 'W' to end of price code number for waterWidthLength(corresponds to tank depth)1“NPTNipplesStandard8“ RiserStandardSURFACEAREASq. ft.LENGTHin.PRICE CODE NO. **316 SS TITANIUM2.753.754.7524364879-1432SA79-1432SB79-1432SC79-1432TA79-1432TB79-1432TC5.757.258.7560789679-1432SD79-1432SE79-1432SF79-1432TD79-1432TE79-1432TFSURFACEAREASq. ft.COIL DIMENSIONS(inches)NUMBER OFTUBESPRICE CODE NUMBER ¹,², ³316 SSWIDTH LENGTH32.032.534.535.218-1/236-1/224-1/218-1/212060961321224161279-1443SK79-1446SE79-1444SH79-1443SL38.038.338.738.842-1/218-1/224-1/236-1/260144108722812162479-1447SE79-1443SM79-1444SJ79-1446SF42.945.145.447.124-1/236-1/242-1/224-1/212084721321624281679-1444SK79-1446SG79-1447SF79-1444SL51.351.452.857.724-1/236-1/242-1/236-1/214496841081624282479-1444SM79-1446SH79-1447SG79-1446SJ60.264.067.670.342-1/236-1/242-1/236-1/296201081322824282479-1447SH79-1446SK79-1447SJ79-1446SL75.076.682.489.842-1/236-1/242-1/242-1/21201441321442824282879-1447SK79-1446SM79-1447SL79-1447SMSURFACEAREASq. ft.COIL DIMENSIONS(inches)NUMBER OFTUBESPRICE CODE NUMBER ¹,², ³316 SSWIDTH LENGTH5.66.76.88.412-1/212-1/218-1/218-1/23036243088121279-1442SB79-1442SC79-1443SA79-1443SB8.89.410.011.512-1/224-1/218-1/224-1/248243630816121679-1442SD79-1444SA79-1443SC79-1444SB13.213.613.713.718-1/224-1/212-1/236-1/248367224121682479-1443SD79-1444SC79-1442SF79-1446SA15.115.816.316.812-1/242-1/218-1/236-1/284246030828122479-1442SG79-1447SA79-1443SE79-1446SB17.217.819.219.512-1/224-1/212-1/218-1/296481087281681279-1442SH79-1444SD79-1442SJ79-1443SF19.520.022.022.642-1/236-1/224-1/218-1/2303660842824161279-1447SB79-1446SC79-1444SE79-1443SG23.223.425.726.142-1/212-1/218-1/224-1/2361329672288121679-1447SC79-1442SL79-1443SH79-1444SF26.328.930.330.636-1/218-1/224-1/242-1/24810884482412162879-1446SD79-1443SJ79-1444SG79-1447SDHEAT EXCHANGERS and GRID/SERPENTINE COILS2900 MacArthur Blvd. Northbrook, IL. USA 60062 www.serfilco.com (800) 323 - 5431HEATERS and HEAT EXCHANGER COILSSTATE-OF-THE-ART IN HEATUnmatched for operating performance, installation ease and quality construction, tube coils are produced from high grade FEP with PTFE guard construction.Compact tube coil exchangers maximize heating/cooling efficiency through a design that not only creates extremely high surface area, but also ensures outstanding flow-through circulation of the process bath by creating uniform spacing be-tween the tubing. No other heat exchanger is faster or cheaper to install/service thanks to a unique design that incorporates a manifold into the heat exchanger package.Only the highest quality components and craftsmanship go into the manufacture of these tube coils . . . so that you can expect outstanding performance and dependability over a long service life.? CONSTRUCTION FROM HIGH GRADE MATERIALSFrame - high strength mechanical grade TeflonGuard and fittings - mechanical grade TeflonCoil - FEP ( virgin fluorinated ethylene propylene) to 30 PSI steam or water (For up to 60 PSI steam or water, consult Sales Dept.)? NON-CONTAMINATING? OUTSTANDING RESISTANCE TO VIRTUALLY ALL ACIDS AND ALKALIES? SIZES FROM 2.25 FT.2 OF EXCHANGE AREA TO 46.5 FT.2? OTHER SIZES AVAILABLECUSTOM COIL CAPABILITIESWe offer many standard model heat exchangers in a wide range of materials such as stainless steel, titanium and FEP. Custom configurations, high density exchange areas, special fittings on connections, and consideration for heating and/or cooling media (as in using a coil for an evaporator for a refrigeration system) are just a few.Consult Sales Dept. MAINTENANCEDue to the well known anti-stick properties of FEP, very little maintenance is required. However, when excessive build-up does occur, either chemically clean or pressure spray to clean.DO NOT ATTEMPT TO CLEAN BY SCRAPING.Manifold fittings may require slight re-tightening after the first 24 hours of use due to the cold flow properties of FEP. However, once re-tightened, no further tightening should be required.HEAT EXCHANGERS FLUOROPOLYMER TUBE COILSA-102_NPage 12F.O.B. Northbrook, Illinois Specifications subject to change without notice.TO ORDER - Select Price Code Number1/4 TUBE COIL - RectangularSURFACEAREAsq. ft.CONNECTIONSin. SIZE inPRICE CODENUMBER2.25 ½" FNPT 11½ x 11½ x 1½ 79-1478X4.5 ½" FNPT 11½ x 11½ x 2 79-1479X4.5 ½" FNPT 15½ x 15½ x 1½ 79-1480X9.25 ½" FNPT 15½ x 15½ x 2 79-1481X1/2 TUBE COIL - RoundSURFACEAREAsq. ft.CONNECTIONSin.PRICE CODESIZE in.PRICE CODENUMBER6 1" FNPT 17½ x 17½ x 2 79-1482X12 1" FNPT 17½ x 17½ x 3¼ 79-1483X18 1½" FNPT 17½ x 17½ x 4½ 79-1484X24 1½" FNPT 17½ x 17½ x 5¾ 79-1485X11.5 1" FNPT 23½ x 23½ x2 79-1486X23 1" FNPT 23½ x 23½ x 3¼ 79-1487X34.5 1½" FNPT 23½ x 23½ x 4½ 79-1488X46.5 1½" FNPT 23½ x 23½ x 5¾ 79-1489X
Most popular related searches