AcuFlow Metering Pumps

AquFlow HydroDrive - AC Variable Frequency Drive Brochure

AquFlow HYDRODRIVETM AC Variable Frequency DriveStandard Features:• Motor Overload Protection**• 200% Starting Torque• Electronic Inrush Current Limit• Short Circuit Protection• Regeneration Protection• Slip Compensation with Boost• Ride Through Power Interruptions• Diagnostic LEDs• 100% Holding Torque at 0 RPM• Barrier Terminal Block• NEMA-4X / IP-65 EnclosureNotes: **UL approved as an electronic overload protector formotors.SpecificationsInput Voltage (VAC ±10%, 50/60Hz) 115 or 208/230Maximum Load (% for 2 Minutes) 150Switching Frequency at Motor (kHz) 16Signal Following Input Voltage (VDC) 0 - 5Signal Following Input Resolution (Bits) 8Maximum Speed Range (% of Base) 70 - 110Minimum Speed Range (% of Base) 0 - 40Acceleration Range (Seconds) 0.3 - 20Deceleration Range (Seconds) 0.3 - 20Slip Compensation Range (Volts/Hz/Amp) 0 - 3Current Limit Range (% Range Setting) 0 - 200Boost Range for 50 Hz Output 0 - 70Boost Range for 60 Hz Output 0 - 35Motor Horsepower (HP) 1/4, 1/2, 3/4, 1Output Frequency (Hz) 0 - 50, 0 - 60Frequency Multiplier (1X, 2X) 1, 2Minimum Operating Frequency at Motor (Hz) 1Speed Regulation (% Base Speed @ 30:1) 2.5VFD Speed Range (Ratio) 60:1Operating Temperature Range (C) 0 - 45The HydroDriveTM AC Variable FrequencyDrive is a variable speed control in a NEMA-4X / IP-65washdown, watertight enclosure. It is designed tooperate 208-230 Volt 3-phase AC induction motorsthrough 3.6 Amps RMS. The sine wave coded PulseWidth Modulated (PWM) output operates at a frequencyof 16Hz which provides high torque and high efficiencyat a low noise level.Due to its ergonomic engineering, the HydroDriveTM AC is easy to install and operate. Tailoringto specific applications is accomplished via selectablejumpers and trimpot adjustments, which eliminate thecomputer-like programming required on other drives.However, for most reciprocating pump applications noadjustments are necessary.Main features include adjustable RMS Current Limit withl2t Motor Overload protection. In addition, adjustable SlipCompensation provides excellent load regulation.Power StartTM delivers over 200% motor torque toensure startup of all pump designs. Electronic InrushCurrent Limit eliminates harmful AC line inrush currentand adjustable Linear Acceleration and Decelerationmake the drive suitable for soft start/stop applications.The Ride Through feature provides a smooth recoveryto the previous set speed during a momentary powerloss and Regeneration Protection eliminates trippingdue to the cyclic loading of reciprocating pumps.Standard front panel features include Diagnostic LEDs,Manual Speed Potentiometer, Auto/Manual Switch,Start/Stop Switch, and a Power On/Off Switch. Otherfeatures include a barrier terminal block to facilitate fieldwiring, adjustable performance trimpots, modular circuitboard, as well as electrical and optical signal isolation.AquFlow HYDRODRIVETM AC Variable Frequency Drive© 2011 AquFlow 1642 McGaw Avenue • Irvine, CA 92614Phone (949) 757-1753 • Fax (949) 757-1687email: sales@aquflow.comhttp://www.aquflow.com Printed in U.S.A. 05/02Bulletin 24310.20TRIMPOT ADJUSTMENTS• Minimum Speed (MIN) • Maximum Speed (MAX)• Acceleration (ACCEL) • Deceleration (DECEL)• Slip Compensation • Current Limit (CL)(COMP) • Boost (BOOST)OPTIONAL ACCESSORY• Multi Speed Board: Provides multi speed operationthrough a PLC.JUMPER SELECTABLE FEATURES• J1/J2 (115V/230V): Selects incoming power voltage.• J3 (1/4, 1/2, 3/4, 1): Selects motor horsepower.• J4 (Auto/Man): Selects automatic or manual reset mode.• J5 (50Hz/60Hz): Selects motor frequency.• J6 (1X/2X): Selects motor frequency multiplier.• J7 (FIX/ADJ): Selects fixed or adjustable boost.Dimensions: (inches/meters)
Most popular related searches

Contact supplier

Drop file here or browse