Adel System Srl
- Home
- Companies & Suppliers
- Adel System Srl
- Downloads
- Battery Chargers CB Manual
Battery Chargers CB Manual
All specifications are subject to change without notice Input: Single-phase 115 ? 277 Vac Output Jumper Selectable: 12 Vcd 6A; 24 Vdc 5 A Power Supply Function: setting by Jumper Suited for the following battery types: Open Lead Acid, Sealed Lead Acid, lead Gel, Ni-Cd, Li-Ion (option) Battery Care for, automatic diagnostic of battery status, short circuit element, Charging curve IUoUo, constant voltage and current Switching technology Semi-resonant Four charging levels: Boost, Absorption, Trickle, Recovery. Protected against short circuit, inverted polarity, over Load. Signal output (contact free) for fault battery state Protection degree IP20 - DIN rail Technical features The CB series is a “Switching technology” and “Battery Care philosophy”, since years parts of the core know-how at ADEL system, led to the development of this advanced multi-stage battery charging method, completely automatic and suited to meet the most advanced requirements of battery manufacturers. The Battery Care concept is base on algorithms that implement rapid and automatic charging, battery charge optimization during time, flat batteries recovery and real time diagnostic during installation and operation. The Real Time Auto-diagnostic system, monitoring battery faults such as, elements in short circuit, accidental reverse polarity connection, disconnection of the battery, they can easily be detected and removed by help of Blink Code of Diagnosis Led; during the installation and after sell. Each device is suited for all battery types, by means of jumpers it is possible setting predefined curves for Open Lead Acid, Sealed Lead Acid, Gel, Ni-Cd and. A rugged casing with bracket for DIN rail mounting provide IP20 protection degree. General Data Insulation voltage (In /Out) 3000 Vac Insulation voltage (In / PE) 1605 Vac Insulation voltage (Out / PE) 500 Vac Protection Class (EN/IEC 60529) IP20 Protection class I, with PE connected Reliability: MTBF IEC 61709 > 300.000 h Pollution Degree Environment 2 Connection Terminal Blocks screw Type 2,5mm(24–14AWG) Dimensions (w-h-d) 45x105x100 mm Weight 0.30 Kg approx Climatic Data Ambient temperature (operation) -25 ÷ +70°C De Rating Ta > 50°C - 2.5%(In) / °C Ambient temperature Storage -40 ÷ +85°C Humidity at 25 °C no condensation 95% to 25°C Cooling Auto Convention Norms and Certifications Conforming to:IEC/EN 60335-2-29,EN60950/UL1236, Electrical safety,89/336/EEC,EMCDirective,2006/95/EC (Low Voltage),DIN41773 (Charging cycle),Emission:IEC 61000-6-4,Immunity: IEC 61000-6-2.CE Signal Output (free switch contact) Main or Backup Input Power Yes Low Battery Yes Fault Battery Yes Type of Signal Output Contact (free switch contact) Max. current can be switched (EN60947.4.1): Max. DC1: 30 Vdc 1 A; AC1: 60 Vac 1A Min.1mA at 5 Vdc Resistive load Min. load Input Data Nominal Input Voltage (2 x Vac) 115 – 230 – 277 Input Voltage range (Vac) 90 – 305 Inrush Current (Vn and In Load) I2t ? 16 A ? 5 msec. Frequency 47 – 63 Hz ?6% Input Current (115 – 270 Vac) 2.4 – 1.2 A Internal Fuse 4 A External Fuse (recommended) 10 A (MCB curve B) Battery Output 24 Vdc (depend on jumper selection) Boost charge (Typ. at In) 28.8 Vdc Recovery Charge 2 – 16 Vdc Charging. Max Ibatt < 40°C (In) 5 A ? 5% Charging. Max Ibatt > 40°C (In) 3.5 A? 5% Battery Output 12 Vdc (depend on jumper selection) Boost charge (Typ. at In) 14.4 Vdc Recovery Charge 2 – 7 Vdc Charging. Max Ibatt < 40°C (In) 6 A ? 5% Charging. Max Ibatt > 40°C (In) 6 A ? 5% Generic Output Data Max. time Bust Charge (typ. At In) 15 h Min. time Bust Charge (typ. At In) 4 min. Jumper Configuration battery type (V cell) Ni-Cd (optional); when in Trickle Charging mode 2.23;2,25;2,27;2,3; 1,41–1,5 (20 cell.) Power Supply function By Jumper Enabling Select Output Voltage 12 or 24 Vdc By Jumper Enabling Select Boost or trickle charge By Jumper Enabling Efficiency (50% of In) 90% Charging current limiting Iadj 20 ÷ 100 % / In Quiescent Current ? 5 mA Charging Curve automatic: IUoUo 4 stage Detection of element in short circuit Yes Short-circuit protection) Yes Over Load protection Yes Over Voltage Output protection Yes Charging Type of charging it is Voltages and current stabilized IUoUo. The state of charging battery and Auto-diagnosis of the systems are identified by a blinking code on a Diagnosis LED and Battery Fault LED: State Diagnosis LED Battery Fault LED Charging Type Trickle - Float 1 Blink/sec OFF Absorption 1 Blink/sec OFF Boost – Bulk 3 Blink/sec OFF Recovery 5 Blink/sec OFF Auto diagnosis Reverse polarity 1Blink ON Battery No connect 2Blink ON Element in Short C. 3Blink ON Replace Battery 5Blink ON CB12245A Battery Charger One product for the field: 12 and 24 Vdc Charging for All Kind of Battery Boost/Trickle Charge selection Input: 115–277 Vac - State of Charge - System Diagnosis Enabling Power Supply Select Battery: 12 or 24 V Charging current Limiting Battery Fault Free switch contact Battery Connection 12 or 24 V Battery Fault Monitoring
Most popular related searches
