Bryan Boilers Div. - Bryan Steam LLC

Bryan - BH Series - Electric Water & Steam Boilers - Brochure

Bryan Steam LLC — Leaders Since 1916 783 N. Chili Ave., Peru, Indiana 46970 U.S.A.Phone:765-473-6651 • Internet:www.bryanboilers.com Fax: 765-473-3074 • E-mail: inquiry@bryansteam.comBryan BH Series Steam & Hot Water BoilersNOTE: Units larger than 2040 KW require two power panels.Specifi cations subject to change without notice. Consult factory for information on other boiler options.Form No. 3200 ©2010 Bryan Steam LLC Printed in USA 50-2312Form No. 3200(Rev. 5/10)Bryan ElectricBH SeriesSteam & Water Boilers196,000 to 7,840,000 BTUH60 to 2,400 KWWater Boiler390BHW4T7Steam Boiler240BHS4T8PLAN VIEWLEFT END VIEW FRONT VIEWPOWER PANEL SIZING CHART — in (cm) Three Phase Voltage 208,240 380,480,575 D E 60-90 KW 60-180 KW 30 (76) 36 (91) 105-180 KW 195-360 KW 30 (76) 48 (122) 195-240 KW 390-480 KW 30 (76) 66 (168) 270-330 KW 510-720 KW 36 (91) 72 ( 183) 360-480 KW 780-1140 KW 60 (152) 82 (208) — 1200-1440 KW 60 (152) 90 (229) — 1530-1920 KW 60 (152) 96 (244) — 2040KW 72 (183) 96 (244) MODELS "W" WATER MODELS "S" 15# STEAM MODELS "Q" 150# STEAM Dimensions in (cm) Dimensions in (cm) Dimensions in (cm)BRYAN® BOILERSNOTE: Units larger than 2040 KW require two power panels. Input KW Length Width Height Inlet Outlet Length Width Height Inlet Outlet Length Width Height Inlet Outlet A B C F G A B C F G A B C F G 60-75 50 33 35 2 2 50 41 43 2 3 50 33 35 1 2 30 (127) (84) (89) (5) (5) (127) (104) (109) (5) (8) (127) (84) (89) (3) (5) (76)90-120 50 33 35 2 2 50 41 43 2 3 50 41 43 1 2 30 (127) (84) (89) (5) (5) (127) (104) (109) (5) (8) (127) (104) (109) (3) (5) (76)135-150 50 41 43 2 2 56 47 49 3 4 50 41 43 1 3 30 (127) (104) (109) (5) (5) (142) (119) (124) (8) (10) (127) (104) (109) (3) (8) (76)165-240 56 47 49 3 3 56 47 49 3 4 80 41 43 1 3 30 (142) (119) (124) (8) (8) (142) (119) (127) (8) (10) (203) (104) (109) (3) (8) (76)270-360 56 47 49 3 3 60 59 61 4 6 80 41 43 1 3 30 (142) (119) (124) (8) (8) (152) (150) (155) (10) (15) (203) (104) (109) (3) (8) (76)390-480 56 53 55 4 4 60 65 67 4 6 60 65 67 2 3 30 (142) (135) (140) (10) (10) (152) (165) (170) (10) (15) (152) (165) (170) (4) (8) (76)510-600 80 47 49 6 6 84 53 55 4 6 84 53 55 2 4 55 (203) (119) (124) (15) (15) (213) (135) (140) (10) (15) (213) (135) (140) (4) (10) (140)660-750 84 53 55 6 6 84 53 55 4 6 84 53 55 2 4 55 (213) (150) (140) (15) (15) (229) (180) (170) (15) (20) (229) (180) (170) (4) (10) (140)780-900 84 59 55 6 6 90 71 67 6 8 90 71 67 2 4 55 (213) (150) (140) (15) (15) (229) (180) (170) (15) (20) (229) (180) (170) (4) (10) (140)960-1020 90 65 61 6 6 90 71 67 6 8 90 71 67 2 6 55 (229) (165) (155) (15) (15) (229) (180) (170) (15) (20) (229) (180) (170) (4) (15) (140)1080-1200 90 71 67 6 6 94 77 73 6 8 94 77 73 2 6 55 (229) (180) (170) (15) (15) (239) (196) (185) (15) (20) (239) (196) (185) (4) (15) (140)1260-1320 90 71 67 6 6 94 77 73 6 8 94 77 73 2 6 55 (229) (180) (170) (15) (15) (239) (196) (185) (15) (20) (239) (196) (185) (4) (15) (140)1380-1440 90 71 67 6 6 98 83 79 6 8 98 83 79 2 6 55 (229) (180) (170) (15) (15) (249) (211) (201) (15) (20) (249) (211) (201) (4) (15) (140)1530-1620 90 71 67 6 6 98 83 79 6 8 98 83 79 2 6 55 (229) (180) (170) (15) (15) (249) (211) (201) (15) (20) (249) (211) (201) (4) (15) (140)1710-1800 94 77 73 6 6 98 83 79 6 8 98 83 79 2 6 55 (239) (196) (185) (15) (15) (249) (211) (201) (15) (20) (249) (211) (201) (4) (15) (140)1920-2040 94 77 73 8 8 102 95 91 6 8 102 95 91 2 6 55 (239) (196) (185) (20) (20) (259) (241) (231) (15) (20) (259) (241) (231) (5) (15) (140)Element RemovalClearanceHBryan electric hot water or steam boilers...For commercial, institutional and industrial applicationsBryan BH Series Boiler Specifi cationsModel Input KW MBH BHP lbs/hr (kg/hr) Water lbs (kg) Steam lbs (kg) Input KW MBH BHP lbs/hr (kg/hr) Water lbs (kg) Steam lbs (kg)60BH 196 6 207 (93) 900 (408) 1,000 (454) 660BH 2,156 66 2,277 (1,033) 3,350 (1,520) 3,600 (1,633)75BH 245 7.5 259 (117) 900 (408) 1,000 (454) 720BH 2,352 72 2,484 (1,127) 3,500 (1,588) 3,800 (1,724)90BH 294 9 311 (141) 1,000 (454) 1,100 (499) 780BH 2,548 78 2,691 (1,221) 3,600 (1,633) 4,000 (1,814)105BH 343 10.5 362 (164) 1,000 (454) 1,300 (590) 840BH 2,744 84 2,898 (1,315) 3,700 (1,678) 4,100 (1,860)120BH 392 12 414 (187) 1,000 (454) 1,300 (590) 900BH 2,940 90 3,105 (1,408) 3,850 (1,746) 4,200 (1,905)135BH 441 13.5 466 (211) 1,200 (544) 1,400 (635) 960BH 3,136 96 3,312 (1,502) 4,000 (1,814) 4,400 (1,996)150BH 490 15 518 (234) 1,200 (544) 1,400 (635) 1020BH 3,332 102 3,519 (1,596) 4,500 (2,041) 5,000 (2,268)165BH 539 16.5 569 (258) 1,300 (590) 1,500 (680) 1080BH 3,528 108 3,726 (1,690) 4,500 (2,041) 5,100 (2,313)180BH 588 18 621 (281) 1,300 (590) 1,500 (680) 1140BH 3,724 114 3,933 (1,784) 5,000 (2,268) 5,500 (2,495)195BH 637 19.5 673 (305) 1,400 (635) 1,700 (771) 1200BH 3,920 120 4,140 (1,878) 5,250 (2,381) 5,700 (2,586)210BH 686 21 725 (328) 1,400 (635) 1,700 (771) 1260BH 4,116 126 4,347 (1,972) 5,500 (2,495) 6,000 (2,722)225BH 735 22.5 776 (352) 1,500 (680) 1,800 (816) 1320BH 4,312 132 4,554 (2,066) 5,600 (2,540) 6,100 (2,767)240BH 784 24 828 (375) 1,600 (726) 1,900 (862) 1380BH 4,508 138 4,761 (2,160) 5,700 (2,586) 6,300 (2,858)270BH 882 27 932 (422) 1,600 (726) 2,000 (907) 1440BH 4,704 144 4,968 (2,253) 5,800 (2,361) 6,400 (2,903)300BH 980 30 1,035 (469) 1,700 (771) 2,200 (998) 1530BH 4,999 153 5,279 (2,394) 6,000 (2,722) 6,600 (2,994)330BH 1,078 33 1,139 (516) 1,800 (816) 2,300 (1,043) 1620BH 5,293 162 5,589 (2,535) 6,200 (2,812) 6,800 (3,084)360BH 1,176 36 1,242 (563) 1,800 (816) 2,400 (1,089) 1710BH 5,587 171 5,900 (2,676) 6,400 (2,903) 7,000 (3,175)390BH 1,274 39 1,346 (610) 2,000 (907) 2,500 (1,134) 1800BH 5,881 180 6,210 (2,817) 6,600 (2,994) 7,200 (3,266)420BH 1,372 42 1,449 (657) 2,000 (907) 2,600 (1,179) 1920BH 6,273 192 6,624 (3,005) 6,800 (3,084) 7,400 (3,357)450BH 1,470 45 1,553 (704) 2,100 (953) 2,700 (1,225) 2040BH 6,665 204 7,038 (3,192) 7,000 (3,175) 7,600 (3,447)480BH 1,568 48 1,656 (751) 2,150 (975) 2,800 (1,270) 2160BH 7,057 216 7,452 (3,380) 7,200 (3,266) 7,800 (3,538)510BH 1,666 51 1,760 (798) 2,500 (1,134) 2,900 (1,315) 2280BH 7,449 228 7,866 (3,568) 7,400 (3,357) 8,100 (3,764)540BH 1,764 54 1,863 (845) 2,500 (1,134) 3,000 (1,361) 2400BH 7,841 240 8,280 (3,756) 7,600 (3,447) 8,300 (3,765)600BH 1,960 60 2,070 (939) 3,000 (1,361) 3,500 (1,588) NOTES: * Lbs. steam per hour from and at 212°F. ** Not intended for use as a principal heating source for living space of any individual residence.Effi ciencyBryan Electric Boilers are nearly 95% effi cient at all load levels. Varying loads do not effect the effi ciency since the resistive type heating elements are immersed and designed to heat the water directly. With a modulating step control only the elements that are required to heat the water to the desired temperature/pressure will be energized in order to encourage a balanced load during operation.Replaceable Hairpins Each element hairpin is fi eld replaceable with no welding, soldering, or brazing required. Each hairpin, as standard for all Bryan Electric Boilers, is Incoloy sheathed and industrial size 0.430? diameter. Elements are designed for 75 watts/sq. inch for long life (optional 50 W/D available). Elements are individually installed in a standard ANSI 150 lb. blind fl ange.Steam Disengaging Area Steam release area is near the middle of the horizontal vessel for maximum steam disengaging area for dry steam and stable water level.Water Boiler Design Vessel is designed for proper circulation around individual elements to maximize heat transfer. High velocities, i.e. heat pump applications, are handled with very little pressure drop when using a horizontal tank for the pressure vessel. Supply and return nozzle sizes can be made larger to accommodate the fl ow requirements. Pressure drop is minimal through the boiler and no dangers are involved with low fl ow conditions.Bryan Series BH Electric hot water** or steam boilers are compact, completely packaged and wired units with automatic controls and featuring long life Incoloy sheathed elements. Applications include hot water heating, steam heating, process heating, and supplemental heat for heat pump type equipment. All Bryan Boilers are built in accordance with the requirements of the ASME boiler and pressure vessel code and are UL listed. Water boilers are 150 psig MAWP and steam boilers either 15 psig or 150 psig. Higher pressures are available.Electric Element BundleEach element replaceable with hand tools. Incoloy sheathed, 75 watts/sq. in.Spacing disc for support and proper circulation around individual elementsRemovable threaded fi ttings for ease of indi-vidual element replacement150 lb. ANSI fl angeWater boiler trim and controls Steam boiler trim and controlsStepindicatinglightsControl panel Lifting lugsASME relief valvePressure and temperature gauges(2) Highlimit controlsDrainOperating controlProbe type low water cutoff controlPower panelFused control circuit transformerBlowdownFused control circuit transformerStepIndicating lights Control panelPowerpanelLiftinglugsStandard Equipment Supplied:HOT WATER DESIGN BOILERS: Model “W” (150# ASME Design) Temperature and pressure gauge, Operating immersion aquastat, 2 high limit aquastats, Low water cutoff, Relief valve, Metal jacket with 4? fi berglass, 75 W/D Incoloy sheathed elements with pressure connector power lugs. Separate power panel and control panel, On/Off control switch, 120 volt control transformer (fused), Magnetic contactors with 120 volt coil, Individual circuit Class JKS fusing, step indicating lamps, First on/fi rst off progressive step controller, National Board Inspection and UL Label.Power Circuit Design:All Bryan BH Series boilers feature copper bus bar distri-bution, wherein the fuse clip for each branch circuit and the main power lugs are all bolted directly to a bus bar. The bus bar can carry the full load current of the boiler, withstanding the largest available fault current from the entering power system. Use of the bus bar protects all current-carrying parts and prevents damage to the boiler.Optional Equipment Available:Power panel door electric interlock. Preheat switch. Flow switch. Manual reset controls. Manual blowdown valve. Automatic blowdown with 24 hour time clock. Alarms. Indicating lights. Larger connection for heat pump applications.Other Designs Available:1) BE – Economical Electric Boilers (Form 3600)2) WT – Indirect Hot Water Supply Heaters (Form 4800)Standard Equipment Supplied:STEAM DESIGN BOILERS: Model “S” (15# ASME Design) Model “Q” (150# ASME Design) Steam pressure gauge w/gauge clock, Operating pressure control, 2 high limit pressure controls, Combination low water cutoff and pump control, Auxiliary low water cutoff, Relief valve, Water glass set, Metal jacket with 4? fi berglass, 75 W/D Incoloy sheathed elements with pressure connector power lugs. Separate power panel and control panel, On/off control switch, 120 volt control transformer (fused), Magnetic contactors with 120 volt coil, Individual circuit Class JKS fusing, Step indicating lamps, First on/ fi rst off progressive step controller, National Board Inspection and UL Label.Standard Design Features Nom. Output Steam Output* Approx. Shipping Weight Model Nom. Output Steam Output* Approx. Shipping WeightASME relief valvePressure gaugeProbe type low water cutoff control(2) high limit controlsOperating controlWater level gauge glassLow water cutoff and pump controlHeavy duty 11 gauge power panel cabinetSingle point electric connectionEach branch circuit is fused individually using copper bus bar for power distributionSeparate control panel for 120V controls4" channel baseLouvered panel cover for proper cooling air circulationImmersion heating bundles broken down in 150 KW bundles or lessHinged access door for access to vessel, ASME and elements4" fi berglass insulation16 gauge jacketing all around structural frame (zinc-coated rust resistant primer and enamel fi nished)Bryan electric hot water or steam boilers...For commercial, institutional and industrial applicationsBryan BH Series Boiler Specifi cationsModel Input KW MBH BHP lbs/hr (kg/hr) Water lbs (kg) Steam lbs (kg) Input KW MBH BHP lbs/hr (kg/hr) Water lbs (kg) Steam lbs (kg)60BH 196 6 207 (93) 900 (408) 1,000 (454) 660BH 2,156 66 2,277 (1,033) 3,350 (1,520) 3,600 (1,633)75BH 245 7.5 259 (117) 900 (408) 1,000 (454) 720BH 2,352 72 2,484 (1,127) 3,500 (1,588) 3,800 (1,724)90BH 294 9 311 (141) 1,000 (454) 1,100 (499) 780BH 2,548 78 2,691 (1,221) 3,600 (1,633) 4,000 (1,814)105BH 343 10.5 362 (164) 1,000 (454) 1,300 (590) 840BH 2,744 84 2,898 (1,315) 3,700 (1,678) 4,100 (1,860)120BH 392 12 414 (187) 1,000 (454) 1,300 (590) 900BH 2,940 90 3,105 (1,408) 3,850 (1,746) 4,200 (1,905)135BH 441 13.5 466 (211) 1,200 (544) 1,400 (635) 960BH 3,136 96 3,312 (1,502) 4,000 (1,814) 4,400 (1,996)150BH 490 15 518 (234) 1,200 (544) 1,400 (635) 1020BH 3,332 102 3,519 (1,596) 4,500 (2,041) 5,000 (2,268)165BH 539 16.5 569 (258) 1,300 (590) 1,500 (680) 1080BH 3,528 108 3,726 (1,690) 4,500 (2,041) 5,100 (2,313)180BH 588 18 621 (281) 1,300 (590) 1,500 (680) 1140BH 3,724 114 3,933 (1,784) 5,000 (2,268) 5,500 (2,495)195BH 637 19.5 673 (305) 1,400 (635) 1,700 (771) 1200BH 3,920 120 4,140 (1,878) 5,250 (2,381) 5,700 (2,586)210BH 686 21 725 (328) 1,400 (635) 1,700 (771) 1260BH 4,116 126 4,347 (1,972) 5,500 (2,495) 6,000 (2,722)225BH 735 22.5 776 (352) 1,500 (680) 1,800 (816) 1320BH 4,312 132 4,554 (2,066) 5,600 (2,540) 6,100 (2,767)240BH 784 24 828 (375) 1,600 (726) 1,900 (862) 1380BH 4,508 138 4,761 (2,160) 5,700 (2,586) 6,300 (2,858)270BH 882 27 932 (422) 1,600 (726) 2,000 (907) 1440BH 4,704 144 4,968 (2,253) 5,800 (2,361) 6,400 (2,903)300BH 980 30 1,035 (469) 1,700 (771) 2,200 (998) 1530BH 4,999 153 5,279 (2,394) 6,000 (2,722) 6,600 (2,994)330BH 1,078 33 1,139 (516) 1,800 (816) 2,300 (1,043) 1620BH 5,293 162 5,589 (2,535) 6,200 (2,812) 6,800 (3,084)360BH 1,176 36 1,242 (563) 1,800 (816) 2,400 (1,089) 1710BH 5,587 171 5,900 (2,676) 6,400 (2,903) 7,000 (3,175)390BH 1,274 39 1,346 (610) 2,000 (907) 2,500 (1,134) 1800BH 5,881 180 6,210 (2,817) 6,600 (2,994) 7,200 (3,266)420BH 1,372 42 1,449 (657) 2,000 (907) 2,600 (1,179) 1920BH 6,273 192 6,624 (3,005) 6,800 (3,084) 7,400 (3,357)450BH 1,470 45 1,553 (704) 2,100 (953) 2,700 (1,225) 2040BH 6,665 204 7,038 (3,192) 7,000 (3,175) 7,600 (3,447)480BH 1,568 48 1,656 (751) 2,150 (975) 2,800 (1,270) 2160BH 7,057 216 7,452 (3,380) 7,200 (3,266) 7,800 (3,538)510BH 1,666 51 1,760 (798) 2,500 (1,134) 2,900 (1,315) 2280BH 7,449 228 7,866 (3,568) 7,400 (3,357) 8,100 (3,764)540BH 1,764 54 1,863 (845) 2,500 (1,134) 3,000 (1,361) 2400BH 7,841 240 8,280 (3,756) 7,600 (3,447) 8,300 (3,765)600BH 1,960 60 2,070 (939) 3,000 (1,361) 3,500 (1,588) NOTES: * Lbs. steam per hour from and at 212°F. ** Not intended for use as a principal heating source for living space of any individual residence.Effi ciencyBryan Electric Boilers are nearly 95% effi cient at all load levels. Varying loads do not effect the effi ciency since the resistive type heating elements are immersed and designed to heat the water directly. With a modulating step control only the elements that are required to heat the water to the desired temperature/pressure will be energized in order to encourage a balanced load during operation.Replaceable Hairpins Each element hairpin is fi eld replaceable with no welding, soldering, or brazing required. Each hairpin, as standard for all Bryan Electric Boilers, is Incoloy sheathed and industrial size 0.430? diameter. Elements are designed for 75 watts/sq. inch for long life (optional 50 W/D available). Elements are individually installed in a standard ANSI 150 lb. blind fl ange.Steam Disengaging Area Steam release area is near the middle of the horizontal vessel for maximum steam disengaging area for dry steam and stable water level.Water Boiler Design Vessel is designed for proper circulation around individual elements to maximize heat transfer. High velocities, i.e. heat pump applications, are handled with very little pressure drop when using a horizontal tank for the pressure vessel. Supply and return nozzle sizes can be made larger to accommodate the fl ow requirements. Pressure drop is minimal through the boiler and no dangers are involved with low fl ow conditions.Bryan Series BH Electric hot water** or steam boilers are compact, completely packaged and wired units with automatic controls and featuring long life Incoloy sheathed elements. Applications include hot water heating, steam heating, process heating, and supplemental heat for heat pump type equipment. All Bryan Boilers are built in accordance with the requirements of the ASME boiler and pressure vessel code and are UL listed. Water boilers are 150 psig MAWP and steam boilers either 15 psig or 150 psig. Higher pressures are available.Electric Element BundleEach element replaceable with hand tools. Incoloy sheathed, 75 watts/sq. in.Spacing disc for support and proper circulation around individual elementsRemovable threaded fi ttings for ease of indi-vidual element replacement150 lb. ANSI fl angeWater boiler trim and controls Steam boiler trim and controlsStepindicatinglightsControl panel Lifting lugsASME relief valvePressure and temperature gauges(2) Highlimit controlsDrainOperating controlProbe type low water cutoff controlPower panelFused control circuit transformerBlowdownFused control circuit transformerStepIndicating lights Control panelPowerpanelLiftinglugsStandard Equipment Supplied:HOT WATER DESIGN BOILERS: Model “W” (150# ASME Design) Temperature and pressure gauge, Operating immersion aquastat, 2 high limit aquastats, Low water cutoff, Relief valve, Metal jacket with 4? fi berglass, 75 W/D Incoloy sheathed elements with pressure connector power lugs. Separate power panel and control panel, On/Off control switch, 120 volt control transformer (fused), Magnetic contactors with 120 volt coil, Individual circuit Class JKS fusing, step indicating lamps, First on/fi rst off progressive step controller, National Board Inspection and UL Label.Power Circuit Design:All Bryan BH Series boilers feature copper bus bar distri-bution, wherein the fuse clip for each branch circuit and the main power lugs are all bolted directly to a bus bar. The bus bar can carry the full load current of the boiler, withstanding the largest available fault current from the entering power system. Use of the bus bar protects all current-carrying parts and prevents damage to the boiler.Optional Equipment Available:Power panel door electric interlock. Preheat switch. Flow switch. Manual reset controls. Manual blowdown valve. Automatic blowdown with 24 hour time clock. Alarms. Indicating lights. Larger connection for heat pump applications.Other Designs Available:1) BE – Economical Electric Boilers (Form 3600)2) WT – Indirect Hot Water Supply Heaters (Form 4800)Standard Equipment Supplied:STEAM DESIGN BOILERS: Model “S” (15# ASME Design) Model “Q” (150# ASME Design) Steam pressure gauge w/gauge clock, Operating pressure control, 2 high limit pressure controls, Combination low water cutoff and pump control, Auxiliary low water cutoff, Relief valve, Water glass set, Metal jacket with 4? fi berglass, 75 W/D Incoloy sheathed elements with pressure connector power lugs. Separate power panel and control panel, On/off control switch, 120 volt control transformer (fused), Magnetic contactors with 120 volt coil, Individual circuit Class JKS fusing, Step indicating lamps, First on/ fi rst off progressive step controller, National Board Inspection and UL Label.Standard Design Features Nom. Output Steam Output* Approx. Shipping Weight Model Nom. Output Steam Output* Approx. Shipping WeightASME relief valvePressure gaugeProbe type low water cutoff control(2) high limit controlsOperating controlWater level gauge glassLow water cutoff and pump controlHeavy duty 11 gauge power panel cabinetSingle point electric connectionEach branch circuit is fused individually using copper bus bar for power distributionSeparate control panel for 120V controls4" channel baseLouvered panel cover for proper cooling air circulationImmersion heating bundles broken down in 150 KW bundles or lessHinged access door for access to vessel, ASME and elements4" fi berglass insulation16 gauge jacketing all around structural frame (zinc-coated rust resistant primer and enamel fi nished)Bryan Steam LLC — Leaders Since 1916 783 N. Chili Ave., Peru, Indiana 46970 U.S.A.Phone:765-473-6651 • Internet:www.bryanboilers.com Fax: 765-473-3074 • E-mail: inquiry@bryansteam.comBryan BH Series Steam & Hot Water BoilersNOTE: Units larger than 2040 KW require two power panels.Specifi cations subject to change without notice. Consult factory for information on other boiler options.Form No. 3200 ©2010 Bryan Steam LLC Printed in USA 50-2312Form No. 3200(Rev. 5/10)Bryan ElectricBH SeriesSteam & Water Boilers196,000 to 7,840,000 BTUH60 to 2,400 KWWater Boiler390BHW4T7Steam Boiler240BHS4T8PLAN VIEWLEFT END VIEW FRONT VIEWPOWER PANEL SIZING CHART — in (cm) Three Phase Voltage 208,240 380,480,575 D E 60-90 KW 60-180 KW 30 (76) 36 (91) 105-180 KW 195-360 KW 30 (76) 48 (122) 195-240 KW 390-480 KW 30 (76) 66 (168) 270-330 KW 510-720 KW 36 (91) 72 ( 183) 360-480 KW 780-1140 KW 60 (152) 82 (208) — 1200-1440 KW 60 (152) 90 (229) — 1530-1920 KW 60 (152) 96 (244) — 2040KW 72 (183) 96 (244) MODELS "W" WATER MODELS "S" 15# STEAM MODELS "Q" 150# STEAM Dimensions in (cm) Dimensions in (cm) Dimensions in (cm)BRYAN® BOILERSNOTE: Units larger than 2040 KW require two power panels. Input KW Length Width Height Inlet Outlet Length Width Height Inlet Outlet Length Width Height Inlet Outlet A B C F G A B C F G A B C F G 60-75 50 33 35 2 2 50 41 43 2 3 50 33 35 1 2 30 (127) (84) (89) (5) (5) (127) (104) (109) (5) (8) (127) (84) (89) (3) (5) (76)90-120 50 33 35 2 2 50 41 43 2 3 50 41 43 1 2 30 (127) (84) (89) (5) (5) (127) (104) (109) (5) (8) (127) (104) (109) (3) (5) (76)135-150 50 41 43 2 2 56 47 49 3 4 50 41 43 1 3 30 (127) (104) (109) (5) (5) (142) (119) (124) (8) (10) (127) (104) (109) (3) (8) (76)165-240 56 47 49 3 3 56 47 49 3 4 80 41 43 1 3 30 (142) (119) (124) (8) (8) (142) (119) (127) (8) (10) (203) (104) (109) (3) (8) (76)270-360 56 47 49 3 3 60 59 61 4 6 80 41 43 1 3 30 (142) (119) (124) (8) (8) (152) (150) (155) (10) (15) (203) (104) (109) (3) (8) (76)390-480 56 53 55 4 4 60 65 67 4 6 60 65 67 2 3 30 (142) (135) (140) (10) (10) (152) (165) (170) (10) (15) (152) (165) (170) (4) (8) (76)510-600 80 47 49 6 6 84 53 55 4 6 84 53 55 2 4 55 (203) (119) (124) (15) (15) (213) (135) (140) (10) (15) (213) (135) (140) (4) (10) (140)660-750 84 53 55 6 6 84 53 55 4 6 84 53 55 2 4 55 (213) (150) (140) (15) (15) (229) (180) (170) (15) (20) (229) (180) (170) (4) (10) (140)780-900 84 59 55 6 6 90 71 67 6 8 90 71 67 2 4 55 (213) (150) (140) (15) (15) (229) (180) (170) (15) (20) (229) (180) (170) (4) (10) (140)960-1020 90 65 61 6 6 90 71 67 6 8 90 71 67 2 6 55 (229) (165) (155) (15) (15) (229) (180) (170) (15) (20) (229) (180) (170) (4) (15) (140)1080-1200 90 71 67 6 6 94 77 73 6 8 94 77 73 2 6 55 (229) (180) (170) (15) (15) (239) (196) (185) (15) (20) (239) (196) (185) (4) (15) (140)1260-1320 90 71 67 6 6 94 77 73 6 8 94 77 73 2 6 55 (229) (180) (170) (15) (15) (239) (196) (185) (15) (20) (239) (196) (185) (4) (15) (140)1380-1440 90 71 67 6 6 98 83 79 6 8 98 83 79 2 6 55 (229) (180) (170) (15) (15) (249) (211) (201) (15) (20) (249) (211) (201) (4) (15) (140)1530-1620 90 71 67 6 6 98 83 79 6 8 98 83 79 2 6 55 (229) (180) (170) (15) (15) (249) (211) (201) (15) (20) (249) (211) (201) (4) (15) (140)1710-1800 94 77 73 6 6 98 83 79 6 8 98 83 79 2 6 55 (239) (196) (185) (15) (15) (249) (211) (201) (15) (20) (249) (211) (201) (4) (15) (140)1920-2040 94 77 73 8 8 102 95 91 6 8 102 95 91 2 6 55 (239) (196) (185) (20) (20) (259) (241) (231) (15) (20) (259) (241) (231) (5) (15) (140)Element RemovalClearanceH
Most popular related searches