NECRON Energy
- Home
- Companies & Suppliers
- NECRON Energy
- Downloads
- C Series - Unintertuptible Power Supply ...
C Series - Unintertuptible Power Supply Brochure
Uninterruptable Power Supply & Data Center Infrastructure Solutionswww.necron.com.tr/en | info@necron.com.trC SERIES1-2-3-5-6-10 KVAClose protectionC Series; is an unintertuptible power supply that has easily got the leading position among its rivals by its special design in parallel with the needs of small offices and medical sector.It is easy to monitor-configure by its user-friendly and pure LCD screen and impressive with its chic design.1 YIL GARANTILI1 YEARS WARRANTYUninterruptable Power Supply & Data Center Infrastructure Solutions www.necron.com.tr/en | info@necron.com.trTechnical specificationsC SERIESINPUTOUTPUTBATTERYINDICATORPROTECTIONGENERALNumber of PhaseVoltage and Voltage TolerancePower FactorFrequencyPower Factor RangeVoltage and Voltage ToleranceSocket TypeFrequency RangeVoltage WaveformTotal Harmonic DistortionCrest FactorOverload CapacityShort - Circuit ProtectionBy-Pass and the Transfer timeBattery Type and PlacementCapacity and Pieces (Internal)Backup Time (%100 Load)Nominal Charge VoltageBattery ChargerStandard ModelLong Time ModelBattery Charge TimeTypeControl PanelMeasurements and AlertsOverloadShort CircuitOverheatedModem/Network ProtectionWarnings and AlertsInterface and ProtocolSoftwareEfficiencyNoise LevelElectromagnetic CompatibilityOperating TemperatureStorage TemperatureOperating HumidityProtection ClassCooling ModeWorking HeightDimensions (WxDxH)Weight (UPS + Battery Module)1 Phase + Neutral0.7 / 0.8 220 VAC ± 2%50 Hz, ± 0.5% HzTrue Sinewave< 2 % Linear Load, < 3 % Non-Linear Load3:130 Sec for 110% ~ 150 % Load, 10 Sec for 150% Load, Then Transfer Bypass ModeElectronic Short Circuit ProtectionStandart Static Bypass, Transfer From Mains to the Battery Without InterruptionVRLA Dry Type Battery, Internal or External Type in an Optional UPS220VAC, 165 ~ 300 VAC> 0.97220VAC, 176 ~ 276 VAC> 0.992xGrounding Plug8x12V / 7Ah 12Vx7Ah x 20 12Vx9Ah x 2013 Minutes 6 Minutes 7 Minute 5 Minute96 VDC85%< 42dBA90%192x460x340 mm32 kg 33 kg 84 kg 93 kg260x717x570 mm145x400x220 mm13 kg0 °C ~ 40 °C,25 °C ~ 70 °C0% ~ 90% ( non-condensing )IP 20Cooling Fan With Variable Speed Depending On Load Level 2000M<45 dBAEN 59001-2, 62040-1-1, 62040-2, 61000-2*2, 61000-4-2, 61000-4-3, 61000-4-4, 61000-4-5<55 dBA1A6.5A1A4.5A240 VDC3x12V / 7Ah8 Minutes36 VDC3xGrounding Plug Connection Terminal< 5 HoursGraphic LCD and LED DisplayTouch Keys ( On , Off, Menu )Input / Output, Voltage & Frequency, Load Level, Battery CapacityElectronic Overload Protection After a Period of Uninterrupted Transfer to BypassAutomatic Inverter ShutdownTransfer to Bypass The Internal Temperature of 90 °C, <80 °C When Transferred Back to InverterSurge Voltage Protection for Modem / Network LineAudible and Visual Alarm for; Battery Operation, Battery Low, Low Voltage, UPS Failure, OverloadRS232 Communication Port DB9 Port, Optional SNMP or AS 400 SupportFree Network Support, Monitoring and Control Software, Windows, Linux, MAC/OSXC2KC1K C3K C6KC5K C10K50 / 60 Hz ± 10%
