Dryair
  1. Companies & Suppliers
  2. Dryair
  3. Downloads
  4. Central Heating Units CHU-1200 - ...

Central Heating Units CHU-1200 - Brochure

DRYAIR INC. 606 Highway Drive, St.Brieux, SK., Canada, SOK 3V0 Tel: (306) 275-4848, 1-888-750-1700, Fax: (306) 275-4664 E-mail: dryair@dryair.ca Web: www.dryair.caDRYAIR INC. 1095 N. Main Street, Bowling Green, Ohio, USA, 43402 Tel: (419) 354-8546, 1-866-354-8546, Fax: (419) 354-9706E-mail: dryair@dryair.us Web: www.dryair.usCentral Heating ModuleModel 2000-1200Features:• Propane or natural gas fuel source. Can beconverted to natural gas or propane with optionalconversion packages.• Compact and portable design for easypositioning on the work site.• Water heater has a 2-stage output allowingvariable heat delivery to accommodate changingheat requirements.• All system operation is controlled and monitoredfrom the heat module control panel2000-1200 050830Product Specs• Temperature control and fuelusage is automatic.• 8-light system operationfeature for easy systemtroubleshooting. • Fluid circulation system is lowpressure and atmosphericallyvented. There is no chance ofan explosion or line burst dueto pressure build-up. Nospecial boiler certification isrequired to operate thesystem.• Quick-connect hose couplers ,“no-drain” fluid lines and a“rapid air elimination” featureensures quick setup-and-gooperation.• A transport trailer is available and is specifically designed to carrythe Dryair 2000-1200 central heating module.45"104"134"84"Type...................................- Staged output, electric spark ignitionTemperature Range...........- 120°F to 200°F (49°C to 93°C)Fuels specs...Natural gas fired.......*Input capacity............- 1,233,000 BTU/H.......*Output capacity .........- 1,023,390 BTU/H.......Gas pressure range ...- 6” to 14” W.C........Manifold gas pressure- 3.5” to 4” W.C........Consumption - max ....- 1,233 CU.FT/H (34.9 CU.M/H)Propane fired.......*Input capacity............- 1,134,360 BTU/H.......*Output capacity .........- 941,544 BTU/H.......Gas pressure..............- 11” W.C........Manifold gas pressure- 10” to 11” W.C........Consumption - max. ...- 12.4 US GAL/H (46.9 L/H)Control & monitoring..........- Full gauge panel monitoringcirculation fluid temperatures &pressures, fuel pressures...........................................- 11-light system operation feature foreasy system troubleshooting.Weight................................- 1,815 LBS. (823 KG)Electrical ............................- 115/230 V, single phase, 60 Hz,30 AmpsLoading - standard.............- Forklift pockets on all four sides Module fluid circulation system...Basic features.................- Atmospherically vented low pressuresystem, adjustable fluidtemperature control, auto pressureby-pass for pump protection andvariable flow demands, autotemperature bypass for heatexchanger protection. ...Heat transfer fluid (HTF) - Non-toxic propylene glycol / watermixture, freeze protected...Primary lines & couplers - 2' fluid circulation lines, 2” ballvalves, 2" Kamlock quick-couplers ...Circulation pump ............- 2 HP, 80 GPM (364 LPM) @ 30P.S.I....Lock-out..........................- Locks out primary “supply” & “return”fluid circulation valves and controlpanelOptional...Transport trailer...Skyhook frame ...............- Steel frame with four corner liftingeyelets, weld attach to water heatermodule base...Gas conversion ..............- Propane or natural gas burner traysand gas trainsSpecifications* For every 1000 ft. increase in elevation after 2000 ft, input BTU's are derate by 4%.
Most popular related searches