BHD Instrumentation Ltd.

Clamp Meter Fluke 322- Brochure

Fluke 320 and 330 SeriesClamp Meters• Narrow body and jaw fit into small spaces• Backlight available on most models• Accurate low current measurements• Inrush current feature on most models• Auto shut-offTechnical DataNew Inrush FeatureA new innovation from Fluke Fluke Clamp Meterswith the inrush feature measure motor startingcurrent like a circuit breaker or overload unit seesit. One button lets you troubleshoot current surgesthat can cause nuisance tripping. Fluke’s inrushfeature gives you a synchronized reading of thecurrent draw profile from motor start up.For more information about Fluke’s new inrushfeature go to www.fluke.com/330 to view Inrush, A Technology Brief.Visit Websitehttp://instrumentation.bhd.ca/BHD CGYTypewritten TextVisit WebsiteBHD CGYTypewritten Texthttp://instrumentation.bhd.ca/321 322AC Amps AC Amps AOhms OhmsAC Volts AC Volts AAuto-Off Auto-OffHold HoldCompact CompactDC VoltsMeasure ac current 400.0 A40.00 A400.0 AMeasure ac voltage400.0 V 400.0 V600 V 600 VMeasure continuity = 30 ? = 30 ?Measure dc voltage400.0 V600 VHigher resolution for loads below 40 amperes0 - 40.00A40.0 - 400.0AMeasure resistance 400.0 ? 400.0 ?Measure inrushWork in poorly lit areasMeasure non-linear loadsMeasure dc currentVariable speed drives and stand-by powerChoose the modelthat fits your work.Looking for a clamp meter that’s rightfor you? Match the functions andfeatures listed below to the FlukeClamp Meter best suited for your job.http://instrumentation.bhd.ca/BHD CGYTypewritten Texthttp://instrumentation.bhd.ca/333 334 335 336 337AC Amps AC Amps AC Amps AC Amps AC AmpsOhms Ohms Ohms Ohms OhmsAC Volts AC Volts AC Volts AC Volts AC VoltsAuto-Off Auto-Off Auto-Off Auto-Off Auto-OffHold Hold Hold Hold HoldFull Size Full Size Full Size Full Size Full SizeDC Volts DC Volts DC Volts DC Volts DC VoltsIn-rush In-rush In-rush In-rushBacklight Backlight Backlight BacklightTrue-rms True-rms True-rmsDC Amps DC AmpsFrequencyLarge JawMIN/MAX400.0 A 600.0 A 600.0 A 600.0 A 999.9 A600.0 V 600.0 V 600.0 V 600.0 V 600.0 V= 30 ? = 30 ? = 30 ? = 30 ? = 30 ?600.0 V 600.0 V 600.0 V 600.0 V 600.0 V600.0 ? 6000 ? 6000 ? 6000 ? 6000 ?100 mS 100 mS 100 mS 100 mSBacklight Backlight Backlight BacklightTrue-rms True-rms True-rms600.0 A 999.9 A400.0 Hzhttp://instrumentation.bhd.ca/BHD CGYTypewritten Texthttp://instrumentation.bhd.ca/Fluke 321 Fluke 322 Fluke 333 Fluke 334 Fluke 335 Fluke 336 Fluke 337Range 0 - 400.0 A 0 - 40.00 A 0 - 400.0 A 0 - 600.0 A 0 - 600.0 A 0 - 600.0 A 0 - 999.9 A40.0 - 400.0 AAccuracy 1.8% ± 5 counts 1.8% ± 5 counts 2% ± 5 counts 2% ± 5 counts 2% ± 5 counts 2% ± 5 counts 2% ± 5 counts(50 - 60 Hz) (50 - 60 Hz) (50 - 60 Hz) (50 - 60 Hz) (50 - 60 Hz) (10 - 100 Hz) (10 - 100 Hz)3.0% ± 5 counts 3.0% ± 5 counts 6% ± 5 counts 6% ± 5 counts(60 Hz - 400 Hz) (60 Hz - 400 Hz) (100 - 400 Hz) (100 - 400 Hz)Crest Factor — — — — 2.4 @ 500 A 3 @ 500 A 3 @ 500 A(50/60 Hz) 2.0 @ 600 A 2.5 @ 600 A 2.5 @ 600 Aadd 2% for C.F.>2 add 2% for C.F.>2 1.42 @ 1000 Aadd 2% for C.F.>2AC Response Averaging Averaging Averaging Averaging True-rms True-rms True-rmsInrush Integration Time — — — 100 mS 100 mS 100 mS 100 mSRange — — — — — 0 - 600.0 A 0 - 999.9 AAccuracy — — — — — 2% + 3 counts 2% + 3 countsRange 0 - 400.0 V 0 - 400.0 V 0 - 600.0 V 0 - 600.0 V 0 - 600.0 V 0 - 600.0 V 0 - 600.0 V0 - 600 V 0 - 600 VAccuracy 1.2% + 5 counts 1.2% + 5 counts 1% + 5 counts 1% + 5 counts 1% + 5 counts 1% + 5 counts 1% + 5 counts(50 - 400 Hz) (50 - 400 Hz) (50/60 Hz) (50/60 Hz) (50/60 Hz) (20 - 100 Hz) (20 - 100 Hz)6% + 5 counts 6% + 5 counts(100 - 400 Hz) (100 - 400 Hz)AC Response Averaging Averaging Averaging Averaging True-rms True-rms True-rmsRange — 0 - 400.0 V 0 - 600.0 V 0 - 600.0 V 0 - 600.0 V 0 - 600.0 V 0 - 600.0 V0 - 600 VAccuracy — 1% + 5 counts 1% + 5 counts 1% + 5 counts 1% + 5 counts 1% + 5 counts 1% + 5 countsRange 0 - 400.0 ? 0 - 400.0 ? 0 - 600.0 ? 0 - 600.0 ? 0 - 600.0 ? 0 - 600.0 ? 0 - 600.0 ?601 - 6000 ? 601 - 6000 ? 601 - 6000 ? 601 - 6000 ?Accuracy 1% ± 5 counts 1% ± 5 counts 1.5% ± 5 counts 1.5% ± 5 counts 1.5% ± 5 counts 1.5% ± 5 counts 1.5% ± 5 countsContinuity = 30 ? = 30 ? = 30 ? = 30 ? = 30 ? = 30 ? = 30 ?Range — — – — — — 5.0 - 400.0 HzAccuracy — — — — — — 0.5% ± 5 countsTrigger Level — — — — — — 10 - 100 Hz = 5 A5 - 10 Hz,100 - 400 Hz = 10 AMIN/MAX No No No No No No YesBacklight No No No No Yes Yes YesDisplay Hold Yes Yes Yes Yes Yes Yes YesHeight 7.5” 7.5” 9.375” 9.375” 9.375” 9.875” 9.875”Size Width 2.5” 2.5” 3.125” 3.125” 3.125” 3.125” 3.125”Depth 1.4” 1.4” 1.625” 1.625” 1.625” 1.625” 1.625”Jaw Opening 1” (25.4 mm) 1” (25.4 mm) 1.2” (30.5 mm) 1.2” (30.5 mm) 1.2” (30.5 mm) 1.2” (30.5 mm) 1.2” (30.5 mm)Max. Wire Size 500 MCM 500 MCM 750 MCM 750 MCM 750 MCM 750 MCM or 750 MCM ortwo 500 MCM two 500 MCMWeight 8 oz. 8 oz. 11 oz. 11 oz. 11 oz. 11 oz. 11 oz.Need Technical Assistance?Call 1-800-44-FLUKE toll free in the U.S. or (800) 36-FLUKE in Canada or (425) 446-5500 in other countries.Fluke CorporationPO Box 9090, Everett, WA USA 98206Fluke Europe B.V.PO Box 1186, 5602 BD Eindhoven, The NetherlandsFor more information call:In the U.S.A. (800) 443-5853 or Fax (425) 446-5116In Europe/M-East/Africa (31 40) 2 675 200 or Fax (31 40) 2 675 222In Canada (800) 36-FLUKE or Fax (905) 890-6866From other countries +1 (425) 446-5500 or Fax +1 (425) 446-5116Web access: http://www.fluke.com©2005 Fluke Corporation. All rights reserved. Printed in U.S.A. 3/2005 1629613 D-US-N Rev CFluke.Keeping your worldup and running.Models 333, 334, 335,336 and 337Operating temperature-14 °F to 122 °F (-10 °C to 50 °C)Altitude2,500 metersBattery life(2) AA alkaline approximately150 hours continuous, auto-matic low battery indicatorSafety ratingIEC 1010-2-031, 600 V CAT IIITemperature de-ratingAdd 0.1 x specified accuracy foreach ºC above 28 ºC or below18 ºCStorage temperature-40 ºF to 140 ºF (-40 ºC to 60 ºC)WarrantyThree yearsModels 321 and 322Operating temperature-14 °F to 122 °F (-10 °C to 50 °C)Altitude2,000 metersBattery life(2) AAA carbon zinc approxi-mately 100 hours continuous,automatic low battery indicatorSafety ratingIEC 1010-2-031, 600 V CAT IIITemperature de-rating< 18 °C, > 28 °C add 0.1 xspecified accuracy / °C Storage temperature-22 °F to 140 °F (-30 °C to 60 °C)WarrantyTwo years600VCAT IIIDesigned and Conforms to IEC 1010-2-031Specifications (@23 ºC + 5 ºC RH 0 - 90%)Visit Websitehttp://instrumentation.bhd.ca/BHD CGYTypewritten TextVisit WebsiteBHD CGYTypewritten Texthttp://instrumentation.bhd.ca/
Most popular related searches