
Cyber Power Systems (USA), Inc.
CyberPower PDU15B4F12R Basic PDU Datasheet
PowerDistributionUnitUser ManualK01-0000082-014241 12th Ave E #400, Shakopee, MN 553791-877-297-6937www.CPSww.comTable of ContentsModel List ......................................................1PDU Naming Convention ............................. 1Package Contents ........................................ 2Safety Precautions ....................................... 2Installation .................................................... 3Horizontal Installation ....................... 3Vertical Installation with Brackets ... 4Vertical Installation - Keyhole Mounts (0U models only) ... 5Cord Retention Tray installation ...... 5Meter Configuration .......................... 5Electrical Installation ........................ 6Troubleshooting ........................................... 6Product FeaturesTechnical Specification ................................ 7Basic Series ....................................... 7Metered Series ................................... 9Basic Series (0U) ............................... 10Metered Series (0U) ........................... 11Warranty & Service .......................................12 Model List:CheckBefore using, please check to ensure the package contains all theitems shown above. If there are missing parts please contactCyberPower technical support at www.CPSww.com or call 1-877-297-6937.Safety Precautions -Read the following before installing or operating the Power Distribution Unit (PDU):1. Use only the supplied hardware to attach the mounting brackets.2. The PDU must only be plugged into a three-wire, grounded outlet on acircuit protected by a fuse or circuit breaker. Connection to any other typeof power outlet may result in a shock hazard.3. Do not use extension cords or adapters with this PDU.4. Never install a PDU, or associated wiring or equipment, during a lightningstorm.5. Check that the power cord, plug, and socket are in good condition.6. CAUTION To prevent the risk of fire or electric shock, this PDU should beinstalled in a temperature and humidity controlled indoor area free ofconductive contaminants. Do not install this PDU where excessivemoisture or heat is present..Basic Series:PDU15B8RPDU15B10RPDU15B12RPDU20B8RPDU20B10RPDU20B12RPDU20BT8RPDU20BT10RPDU20BT12RPDU15B2F8RPDU15B2F10RPDU15B2F12RPDU15B4F8RPDU15B4F10RPDU15B4F12RPDU15B6F8RPDU15B6F10RPDU15B6F12RPDU20B2F8RPDU20B2F10RPDU20B2F12RPDU20B4F8RPDU20B4F10RPDU20B4F12RPDU20B6F8RPDU20B6F10RPDU20B6F12RPDU20BT2F8RPDU20BT2F10RPDU20BT2F12RPDU20BT4F8RPDU20BT4F10RPDU20BT4F12RPDU20BT6F8RPDU20BT6F10RPDU20BT6F12RMetered Series:PDU15M2F8RPDU15M2F10RPDU15M2F12RPDU20M2F8RPDU20M2F10RPDU20M2F12RPDU20MT2F8RPDU20MT2F10RPDU20MT2F12RBasic Series (0U):PDU15BV14FPDU15BV16FPDU15BV20FPDU15BV28FPDU15BV32FPDU20BV14FPDU20BV16FPDU20BV20FPDU20BV28FPDU20BV32FPDU20BVT14FPDU20BVT16FPDU20BVT20FPDU20BVT28FPDU20BVT32FMetered Series (0U):PDU15MV20FPDU15MV26FPDU15MV32FPDU20MV20FPDU20MV26FPDU20MV32FPDU20MVT20FPDU20MVT26FPDU20MVT32FPDU Naming Convention:1. Amperage: 2. Series: 3. Rack Space: 4. Input Voltage: 5. Plug Type: 6. Outlet Number Front 7. Outlet Number Rear 8. Network Management PDU XX M V HV T F R NET1 2 3 4 5 6 7 8Amperage – 15A, 20A, 30A B: =Basic M: =Metered SW: = SwitchedNULL: =Horizontal V:= VerticalNULL: =120V HV:= High Voltage – 200V to 230VNULL: =NEMA 5-15P / 5-20P T: = Twist (NEMA L5-L6 Plug) IEC:= (IEC C14/C20)Number of Outlets followed by F – Example 8FNumber of Outlets followed by R – Example 8RNET For information on Cyberpower products, visit www.CPSww.com For information on Cyberpower products, visit www.CPSww.com1 2Package ContentsPDU (1) Cord Retention Tray (1/2/3/4 pcs - varies by model)Horizontal InstallationUsed (1 set) Vertical InstallationUsed (1 set)Mounting BracketsVertical Mounting Brackets (1 set)(for 0U models only) Keyhole Mounting Pegs (2pcs)with Screws M4 X 8 (2pcs)(for 0U models only)Bracket MountingScrews M4 X 8 (4pcs)Cord Retainer Clips (8/10/12/14/16/20/24/30/32/38 pcs - varies by model) for Cord Retention TrayDocumentation:User ManualPowerDistributionUnitUser ManualProduct Registration Card ProductRegistration Card Cord Retention Tray Mounting Screws M3 X 6 (4/8/12/16 pcs - varies by model) Ground Screw M4 X 6 (1 pcs)InstallationHorizontal Installation (1U models only)Vertical Installation with BracketsStep 1 – Mounting bracket installationInstall the screws (M4 X 8) in holes diagonal from each other.Step 2 – PDU MountingInstall the PDU using fasteners compatible with the rack.Step 2 – PDU MountingInstall the PDU using fasteners compatible with the rack.Vertical Installation with Brackets (0U models only)Step 1 – Mounting bracket installationAttach the Vertical Mounting Brackets to the PDU with the 4 supplied Bracket Mounting Screws (M4 X 8).Step 2 – PDU MountingInstall the PDU using fasteners compatible with the rack.For information on Cyberpower products, visit www.CPSww.com For information on Cyberpower products, visit www.CPSww.com3 4Step 1 – Mounting bracket installationInstall the screws (M4 X 8) in holes diagonal from each other.Vertical Installation with Keyhole Mounts (0U Models) Electrical InstallationEnsure that the plug type of your PDU unit (e.g. NEMA 5-15P, NEMA 5-20P, NEMA L5-30P) matches the wall receptacle type that you are using.Step 1 – Receptacle evaluationPDU must be plugged into a three-wire, grounded wall receptacle only. The wall receptacle must also be connected to an appropriate branch circuit/main with fuse or circuit breaker protection. Connection to any other type of wall receptacle may result in a shock hazard.CAUTIONStep 2 – Plug the PDU into the wall receptacleStep 3 – Attach equipmentBefore attaching equipment, it is important to calculate the total load that you will be placing on the PDU. It is extremely important not to exceed the PDU's maximum current load (as outlined in the Specifications section). In order to determine your total load, simply add up the amperage of your devices and ensure that it does not exceed the unit’s capacity.TroubleshootingProblem Possible Cause SolutionPDU Outlets do notprovide power toconnectedequipment1. Open breaker2. Loose power cordReset Breaker check ifplug is completelyconnected.If the problem remainscontact tech support.Amperage displayedon Amperage Meterexceeds the unit’scapability (Meteredtype only)1. Overload2. Amperage meter isdamagedThe meter will flashwhen overloaded. Reduce the load on the PDU until the overload is gone. If the problem remains contact tech support.Circuit breaker hastripped1. Sustained overload2. Excessive ambient orinternal temperatures.3. Faulty breakerReset Breaker.If the problem remainscontact tech support.Align the the Keyhole Mounts to the Keyhole Slots on the rack. Insert and slide down to lock firmly into place.Step 2 – PDU MountingStep 1 – Keyhole Mount installationAttach the Keyhole Mounting Pegs to the PDU with the 2 supplied Bracket Mounting Screws (M4 X 8).For information on Cyberpower products, visit www.CPSww.com For information on Cyberpower products, visit www.CPSww.com5 6Cord Retention Tray installation (Optional for both horizontal and vertical installations)Attach the Cord Retention Tray to the PDU with the 4 supplied CordRetention Tray Mounting Screws (M3 X 6).Attach the Cord Retainer Clips to the Cord Retention Tray.Meter ConfigurationUse a screwdriver to gently remove the LED Meter. Rotate the LED Meter 90 degrees, and insert back into the PDU.NoteDepending on installation method (vertical or horizontal), the LED Meter may need to be rotated, before installation, for proper orientation. Basic Series Basic SeriesProduct FeaturesFront ViewBack ViewA BA. Mounting BracketB. Rear OutletsC. External Site GroundA. Mounting BracketB. Circuit BreakerA B C DD. AC Power CordE.EED. AC Power CordE. Cord Retention Tray Screw HolesEEProduct FeaturesFront ViewBack ViewA B C DA B CA. Mounting BracketB. Rear OutletsC. External Site GroundA. Mounting BracketB. Circuit BreakerC. Front Outlets D. AC Power CordE. Cord Retention Tray Screw HolesEETechnical Specifications Technical SpecificationsFor information on Cyberpower products, visit www.CPSww.com For information on Cyberpower products, visit www.CPSww.com7 8Model NamePDU15B8RPDU15B10RPDU15B12RPDU20B8RPDU20B10RPDU20B12RPDU20BT8RPDU20BT10RPDU20BT12RInput Voltage Max current 15 A Circuit Breaker 15 A Plug Type NEMA 5-15P NEMA 5-20P NEMA L5-20POutput Voltage Current 15 A Outlet Type NEMA 5-15RIndicators LED Indicators Meter ReadoutPhysicalEnvironmental Humidity Altitude TemperatureSafety Approvals Certifications WarrantyETL (test followed UL 1363)RoHSLifetimeOperating 0 to 95% Non-condensingNon-Operating 0 to 95% Non-condensingOperating 0ft to 10,000ftNon-Operating 0ft to 50,000ftOperating 32F to 95FNon-Operating 5F to 113FN/A17.5" x 1.5" x 1.75" / 44.5 x 3.81 x 4.45 cm15 ftN/A100 ~ 125 V20 ANEMA 5-20R100 ~ 125 V20 A20 A Power Cord Length Dimension (WxDxH)Model NamePDU15B2F8RPDU15B2F10RPDU15B2F12RPDU15B4F8RPDU15B4F10RPDU15B4F12RPDU15B6F8RPDU15B6F10RPDU15B6F12RPDU20B2F8RPDU20B2F10RPDU20B2F12RPDU20B4F8RPDU20B4F10RPDU20B4F12RPDU20B6F8RPDU20B6F10RPDU20B6F12RPDU20BT2F8RPDU20BT2F10RPDU20BT2F12RPDU20BT4F8RPDU20BT4F10RPDU20BT4F12RPDU20BT6F8RPDU20BT6F10RPDU20BT6F12RInput Voltage Max current 15 A Circuit Breake 15 A Plug Type NEMA 5-15P NEMA 5-20P NEMA L5-20POutput Voltage Current 15 A Outlet Type NEMA 5-15RIndicators LED Indicators Meter ReadoutPhysicalEnvironmental Humidity Altitude TemperatureSafety Approvals Certifications WarrantyETL (test followed UL 1363)RoHSLifetimeOperating 0 to 95% Non-condensingNon-Operating 0 to 95% Non-condensingOperating 0ft to 10,000ftNon-Operating 0ft to 50,000ftOperating 32F to 95FNon-Operating 5F to 113FN/A17.5" x 2.25" x 1.75" / 44.5 x 5.72 x 4.45 cmN/A100 ~ 125 V20 ANEMA 5-20R100 ~ 125 V20 A20 A15 ft Power Cord Length Dimension (WxDxH)Metered Series Product FeaturesFront ViewBack ViewA B C DA B C DA. Mounting BracketB. Rear OutletsC. External Site GroundA. Mounting BracketB. Circuit BreakerC. LED Meter ReadoutD. Front Outlets D. AC Power CordE. Cord Retention Tray Screw HolesEETechnical SpecificationsFor information on Cyberpower products, visit www.CPSww.com For information on Cyberpower products, visit www.CPSww.com9 10Basic Series (0U)Technical SpecificationsProduct FeaturesFront View Back ViewABCDEEDDDBAABA. AC Power Cord B. Circuit Breaker C. External Site Ground D. Cord Retention Tray Screw Holes E. Front OutletsA. Bracket Screw Hole B. Keyhole Mount Peg Screw Holes Model NamePDU15M2F8RPDU15M2F10RPDU15M2F12RPDU20M2F8RPDU20M2F10RPDU20M2F12RPDU20MT2F8RPDU20MT2F10RPDU20MT2F12RInput Voltage Max Current 15 A Circuit Breaker 15 A Plug Type NEMA 5-15P NEMA 5-20P NEMA L5-20P Power Cord LengthOutput Voltage Current 15 A Outlet Type NEMA 5-15RFiters & Protection EMI/RFI Filtration Surge SuppressionIndicators LED Indicators Meter ReadoutPhysicalEnvironmental Humidity Altitude TemperatureSafety Approvals Certifications Warranty100 ~ 125 V20 A20 A15 ft100 ~ 125 V20 ANEMA 5-20RN/AN/AN/AAmperage17.5" x 2.25" x 1.75" / 44.5 x 5.72 x 4.45 cmETL (test followed UL 1363)RoHSLifetimeOperating 0 to 95% Non-condensingNon-Operating 0 to 95% Non-condensingOperating 0ft to 10,000ftNon-Operating 0ft to 50,000ftOperating 32F to 95FNon-Operating 5F to 113F Dimension (WxDxH)Model NamePDU15BV14FPDU15BV16FPDU15BV20FPDU15BV28FPDU15BV32FPDU20BV14FPDU20BV16FPDU20BV20FPDU20BV28FPDU20BV32FPDU20BVT14FPDU20BVT16FPDU20BVT20FPDU20BVT28FPDU20BVT32FInput Voltage Max Current 15 A Circuit Breaker 15 A Plug Type NEMA 5-15P NEMA 5-20P NEMA L5-20POutput Voltage Current 15 A Outlet Type NEMA 5-15RIndicators LED Indicators Meter ReadoutPhysicalEnvironmental Humidity Altitude TemperatureSafety Approvals Certifications Warranty LifetimeOperating 0 to 95% Non-condensingNon-Operating 0 to 95% Non-condensingOperating 0ft to 10,000ftNon-Operating 0ft to 50,000ftOperating 32F to 95FNon-Operating 5F to 113F1.75" x 1.5" x 24" / 4.45 x 3.81 x 60.96 cm1.75" x 1.5" x 36" / 4.45 x 3.81 x 91.44 cm1.75" x 1.5" x 48" / 4.45 x 3.81 x 121.92 cm1.75" x 1.5" x 60" / 4.45 x 3.81 x 152.40 cm1.75" x 1.5" x 70" / 4.45 x 3.81 x 177.80 cmETL (test followed UL 1363)RoHSN/AN/ANEMA 5-20R20 A100 ~ 125 V20 A20 A10 ft100 ~ 125 V Power Cord Length Dimension (WxDxH)Metered Series (0U)Technical SpecificationsProduct FeaturesFront View Back ViewABCDEEDDDBAABFA. AC Power Cord B. Circuit Breaker C. External Site Ground D. Cord Tray Screws Holes E. Front OutletsF. LED Meter ReadoutA. Bracket Screw Hole B. Keyhole Mount Peg Screw Holes For information on Cyberpower products, visit www.CPSww.com For information on Cyberpower products, visit www.CPSww.com11 12Model NamePDU15MV20FPDU15MV26FPDU15MV32FPDU20MV20FPDU20MV26FPDU20MV32FPDU20MTV20FPDU20MTV26FPDU20MTV32FInput Voltage Max Current 15 A Circuit Breaker 15 A Plug Type NEMA 5-15P NEMA 5-20P NEMA L5-20POutput Voltage Current 15 A Outlet Type NEMA 5-15RIndicators LED Indicators Meter ReadoutPhysicalEnvironmental Humidity Altitude TemperatureSafety Approvals Certifications Warranty100 ~ 125 V20 A20 A10 ftN/A100 ~ 125 V20 ANEMA 5-20RETL (test followed UL 1363)RoHSLifetimeOperating 0 to 95% Non-condensingNon-Operating 0 to 95% Non-condensingOperating 0ft to 10,000ftNon-Operating 0ft to 50,000ftOperating 32F to 95FNon-Operating 5F to 113FAmperage1.75" x 2.25" x 48" / 4.45 x 5.72 x 121.92 cm1.75" x 2.25" x 60" / 4.45 x 5.72 x 152.40 cm1.75" x 2.25" x 70" / 4.45 x 5.72 x 177.80 cm Power Cord Length Dimension (WxDxH)Product Registration Thank you for purchasing a CyberPower product. Prompt product registration entitles coverage under the Limited Warranty, and also allows the opportunity to be notified of product enhancements, upgrades, and other announcements. Registration is quick and easy at www.cpsww.com/register .Need Additional Help? Feel free to contact our Tech Support department with installation,troubleshooting, or general product questions.CyberPower Technical SupportPhone: 1-877-297-6937Email: tech@cpsww.comWeb: www.CPSww.comMail: 4241 12th Avenue E, Suite 400 Shakopee, MN 55379Hours of Operation: Monday – Friday, 8:00am – 5:00pm (CST)Limited Warranty Read the following terms and conditions carefully before using the CyberPower PDU(the “Product”). By using the Product you consent to be bound by and become a party to the terms and conditions of this Limited Warranty (together referred to as this “Warranty”). If you do not agree to the terms and conditions of this Warranty, you should return the Product for a full refund prior to using it.Who is Providing this Warranty? CyberPower Systems (USA), Inc. (“CyberPower”) provides this Limited Warranty.What Does This Warranty Cover? This warranty covers defects in materials and workmanship in the Product under normal use and conditions.What is the Period of Coverage? This Warranty is for as long as the original owner owns the Product.Who Is Covered? This warranty only covers the original purchaser. Coverage ends if you sell or otherwise transfer the Product.How Do You Get Service? 1. Call us at (877) 297-6937 or write to us at Cyber Power Systems (USA), Inc., 4241 12th Ave. E., STE 400, Shakopee, MN 55379 or send us an e-mail message at claims@cyberpowersystems.com for instructions.2. When you contact CyberPower, identify the Product, the Purchase Date, and the item(s) of Connected Equipment. Have information on all applicable insurance or other resources of recovery/payment that are available to the Initial Customer and Request a Claim Number. 3. You must provide a purchase receipt (or other proof of the original purchase) and provide a description of the defect.4. Pack and ship the product to CyberPower and, if requested, the item(s) of Connected Equipment, a repair cost estimate for the damage to the Connected Equipment, and all claim forms that CyberPower provides to you. Show the Claim Number on the shipping label or include it with the product. You must prepay all shipping costs, you are responsible for packaging and shipment, and you must pay the cost of the repair estimate.What Will We Do To Correct Problems? CyberPower will inspect and examine the Product. If the Product is defective in material or workmanship, CyberPower will repair or replace it at CyberPower's expense, or, if CyberPower is unable to or decides not to repair or replace the Product (if defective) within a reasonable time, CyberPower will refund to you the full purchase price you paid for the Product (purchase receipt showing price paid is required).Who Pays For Shipping? We pay when we send items to you; you pay when you send items to us.What Are Some Things This Warranty Does Not Cover? 1. This Warranty does not cover any software that was damaged or needs to be replaced due to the failure of the Product or any data that is lost as a result of the failure or the restoration of data or records, or the reinstallation of software.2. This Warranty does not cover or apply to: misuse, modification, operation or storage outside environmental limits of the Product or the equipment connected to it, nor for damage while in transit or in storage, nor if there has been improper operation or maintenance, or use with items not designed or intended for use with the Product, such as laser printers, appliances, aquariums, medical or life support devices, etc.What are the Limitations? 1. This Warranty does not apply unless the Product and the equipment that was connected to it were connected to properly wired and grounded outlets (including compliance with electrical and safety codes of the most current electrical code), without the use of any adapters or other connectors.2. The Product must have been plugged directly into the power source and the equipment connected to the Product must be directly connected to the Product and not “daisy-chained” together in serial fashion with any extension cords, another Product or device similar to the Product, surge suppressor, or power tap. Any such installation voids the Limited Warranty.3. The Product and equipment connected to it must have been used properly in a suitable and proper environment and in conformance with any license, instruction manual, or warnings provided with the Product and the equipment connected to it.4. The Product must have been used at all times within the limitations on the Product's VA capacity. 5. The sole and exclusive remedies of the Initial Customer are those provided by this Warranty.Contact Information CyberPower Systems, Inc. 4241 12th Ave. EastSuite 400Shakopee, MN 55379 Phone: (952) 403-9500 Toll-free: (877) 297-6937CyberPower is the warrantor under this Limited Warranty. You may also contact CyberPower on the web at CPSww.com.For information on Cyberpower products, visit www.CPSww.com For information on Cyberpower products, visit www.CPSww.com13 14
Stay in the loop!
Select your areas of interest to receive industry updates.