DAPE New Energy

DAPE Solar Controllers

A energia que vem do solControladores para bombas solares 0.8kW-220.0kWsolar pumps controller ECO2www.dape.pt | geral@dape.pt | 00351 253 286 351CBS 080 01 | CBS 150 01 water that comes from the sun0.8kW-1.5kW Robust and easy to installThermic balance via forced coolingLED for identi?cation of the working modesContacts for level control stoppersHigh performance hybrid regulator for solar pumping systemsWorks with electric pumps till 1.5kWWorks with solar panels and generators/electric gridCan be fed simultaneously with generator and electric grid High conversion e?ciency rate, low noise, long-lifeMPTT state-of-the-art technology, e?ectiveness >99.9% Run dry working detector - motor protectionRobust system, unfailling protectionNew design - case 100&% hermeticeasy to install, operate and maintenancemain featuresCBS 080 01 CBS 150 01Item | Type 0.75 kW 1.50 kWMax. input DC voltage (Voc) 390 V 390 VRecommended MPPT voltage (vmp) 280-380 V 280-380 VRecommend PV power input 1,35 kWp 2,60 kWpMax. MPPT e?ciency 99% 99%Number of string´s 1 1Rated input voltage 230~ V, 1-phase 230~ V, 1-phaseInput frequency range 50~60 Hz 50~60 HzMax. motor output power 0,75 kW 1,50 kWRated output voltage 230~ V, 3-phase 230~ V, 3-phaseOutput frequency range 0~50/60 Hz 0~50/60 HzRated output current 9,6 A 12,0 AMax. e?eciency 97% 97%Protection class I IProtection degree IP54 IP54Environment temperature (-)25°C to (+)65°C (-)25°C to (+)65°CCooling Forced cooling Forced coolingDisplay LCD LCDDimension (LxWxH) 463x300x198 (mm) 463x300x198 (mm)Weight 12,2 Kg 12,6 KgShipping dimension (LxWxH) 580x305x240 (mm) 580x305x240 (mm) AC OUTPUT DC INPUT AC INPUT SYSTEM GENERAL DATAController 3.0 for irrigation Modern and functional designConnections Tested in dozens of electropumpsCBS 220 01 CBS 400 01Item | Type 2.2 kW 4.0 kWMax. input DC voltage (Voc) 790 V 790 VRecommended MPPT voltage (vmp) 500-700 V 500-700 VRecommend PV power input 3,70 kWp 6,60 kWpMax. MPPT e?ciency 99% 99%Number of string´s 1 2Rated input voltage 400~ V, 3-phase 400~ V, 3-phaseInput frequency range 50~60 Hz 50~60 HzMax. motor output power 2,20 kW 4,00 kWRated output voltage 400~ V, 3-phase 400~ V, 3-phaseOutput frequency range 0~50/60 Hz 0~50/60 HzRated output current 8,8 A 17,5 AMax. e?eciency 97% 97%Protection class I IProtection degree IP54 IP54Environment temperature (-)25°C to (+)65°C (-)25°C to (+)65°CCooling Forced cooling Forced coolingDisplay LCD LCDDimension (LxWxH) 673x400x247 (mm) 673x400x247 (mm)Weight 12,6 Kg 22,7 KgShipping dimension (LxWxH) 780x400x400 (mm) 780x400x400 (mm) DC INPUT AC INPUT AC OUTPUT SYSTEM GENERAL DATAHigh performance hybrid regulator for solar pumping systemsWorks with electric pumps from 2.2k to 4.0kWWorks with solar panels and generators/electric gridCan be fed simultaneously with generator and electric grid High conversion e?ciency rate, low noise, long-lifeMPTT state-of-the-art technology, e?ectiveness >99.9% Run dry working detector - motor protectionRobust system, unfailling protectionNew design - case 100&% hermeticeasy to install, operate and maintenancemain features Robust and easy to installThermic balance via forced coolingLED for identi?cation of the working modesContacts for level control stoppersECOwww.dape.pt | geral@dape.pt | 00351 253 286 3512.2kW-4.0kWCBS 220 01 | CBS 400 01solar pumps controller water that comes from the sunController 3.0 for irrigation Modern and functional designConnections Tested in dozens of electropumpsHigh performance hybrid regulator for solar pumping systemsWorks with electric pumps from 5.5kW to 15.0kWWorks with solar panels and generators/electric gridCan be fed simultaneously with generator and electric grid High conversion e?ciency rate, low noise, long-lifeMPTT state-of-the-art technology, e?ectiveness >99.9% Run dry working detector - motor protectionRobust system, unfailling protectionNew design - case 100&% hermeticeasy to install, operate and maintenancemain features Robust and easy to installThermic balance via forced coolingLED for identi?cation of the working modesContacts for level control stoppersECOwww.dape.pt | geral@dape.pt | 00351 253 286 351CBS 550 01 | CBS 750 01 | CBS 1100 01 | CBS 1500 015.5kW-15.0kWCBS 550 01 CBS 750 01 CBS 1100 01 CBS 1500 01Item | Type 5.5 kW 7.5 kW 11.0 kW 15.0 kWMax. input DC voltage (Voc) 790 V 790 V 790 V 790 VRecommended MPPT voltage (vmp) 500-700 V 500-700 V 500-700 V 500-700 VRecommend PV power input 9,00 kW 12,00 kW 18,00 kW 24,00 kWMax. MPPT e?ciency 99% 99% 99% 99%Number of string´s 2 3 4 6Rated input voltage 400~ V, 3-phase 400~ V, 3-phase 400~ V, 3-phase 400~ V, 3-phaseInput frequency range 50~60 Hz 50~60 Hz 50~60 Hz 50~60 HzMax. motor output power 5,50 kW 7,50 kW 11,0 kW 15,0 kWRated output voltage 400~ V, 3-phase 400~ V, 3-phase 400~ V, 3-phase 400~ V, 3-phaseOutput frequency range 0~50/60 Hz 0~50/60 Hz 0~50/60 Hz 0~50/60 HzRated output current 23,0 A 31,0 A 34,0 A 38,0 AMax. e?eciency 97% 97% 97% 97%Protection class I I I IProtection degree IP54 IP54 IP54 IP54Environment temperature (-)25°C to (+)65°C (-)25°C to (+)65°C (-)25°C to (+)65°C (-)25°C to (+)65°CCooling Forced cooling Forced cooling Forced cooling Forced coolingDisplay LCD LCD LCD LCDDimension (LxWxH) 673x400x247 (mm) 673x400x247 (mm) 673x400x247 (mm) 673x400x247 (mm)Weight 24,2 Kg 24,8 Kg 26,6 Kg 26,7 KgShipping dimension (LxWxH) 780x400x400 (mm) 780x400x400 (mm) 780x400x400 (mm) 780x400x400 (mm) DC INPUT AC INPUT AC OUTPUT SYSTEM GENERAL DATAsolar pumps controller water that comes from the sunController 3.0 for irrigation Modern and functional designConnections Tested in dozens of electropumpsECOwww.dape.pt | geral@dape.pt | +351 253 286 351Robust system, easy to installLCD display in the interior for easy programming of the systemCBS 1850 01 | CBS 2200 01 | CBS 3000 01 | CBS 3700 01 | CBS 4500 0118.5kW-45.0kWCBS 1850 01 CBS 2200 01 CBS 3000 01 CBS 3700 01 CBS 4500 01Item | Type 18.5 kW 22.0 kW 30.0 kW 37.0 kW 45.0 kWMax. input DC voltage (Voc) 790 V 790 V 790 V 790 V 790 VRecommended MPPT voltage (vmp) 500-700 V 500-700 V 500-700 V 500-700 V 500-700 VRecommend PV power input 30,0 kWp 35,0 kWp 45,0 kW 55,0 kW 65,0 kWMax. MPPT e?ciency 99% 99% 99% 99% 99%Number of string´s 6 7 9 11 13Rated input voltage 400~ V, 3-phase 400~ V, 3-phase 400~ V, 3-phase 400~ V, 3-phase 400~ V, 3-phaseInput frequency range 50~60 Hz 50~60 Hz 50~60 Hz 50~60 Hz 50~60 HzMax. motor output power 18,5 kW 22,0 kW 30,0 kW 37,0 kW 45,0 kWRated output voltage 400~ V, 3-phase 400~ V, 3-phase 400~ V, 3-phase 400~ V, 3-phase 400~ V, 3-phaseOutput frequency range 0~50/60 Hz 0~50/60 Hz 0~50/60 Hz 0~50/60 Hz 0~50/60 HzRated output current 57,0 A 70,0 A 85,0 A 105 A 135 AMax. e?eciency 97% 97% 97% 97% 97%Protection class I I I I IProtection degree IP54 IP54 IP54 IP54 IP54Environment temperature (-)25°C to (+)65°C (-)25°C to (+)65°C (-)25°C to (+)65°C (-)25°C to (+)65°C (-)25°C to (+)65°CCooling Forced cooling Forced cooling Forced cooling Forced cooling Forced coolingDimension (LxWxH) 1500x600x400 (mm) 1500x600x400 (mm) 1500x600x400 (mm) 1500x600x400 (mm) 1500x600x400 (mm)Weight 80,0 kg 90,0 kg 100,0 kg 110,0 kg 110,0 kgShipping dimension (LxWxH) 1600x650x450 (mm) 1600x650x450 (mm) 1600x650x450 (mm) 1600x650x450 (mm) 1600x650x450 (mm) DC INPUT AC INPUT AC OUTPUT SYSTEM GENERAL DATAsolar pumps controller water that comes from the sunHigh performance hybrid regulator for solar pumping systemsWorks with electric pumps from 18.5kW to 45.0kWWorks with solar panels and generators/electric gridCan be fed simultaneously with generator and electric grid High conversion e?ciency rate, low noise, long-lifeMPTT state-of-the-art technology, e?ectiveness >99.9% Run dry working detector - motor protectionRobust system, unfailling protectionNew design - case 100&% hermeticeasy to install, operate and maintenancemain featuresThermic balance via forced coolingContacts for level control stoppersAcess to the contacts Panel’s controlSystem data display Source selectorHigh performance hybrid regulator for solar pumping systemsWorks with electric pumps from 18.5kW to 45.0kWWorks with solar panels and generators/electric gridCan be fed simultaneously with generator and electric grid High conversion e?ciency rate, low noise, long-lifeMPTT state-of-the-art technology, e?ectiveness >99.9% Run dry working detector - motor protectionRobust system, unfailling protectionNew design - case 100&% hermeticeasy to install, operate and maintenancemain featuresRobust system, easy to installLCD display in the interior for easy programming of the systemThermic balance via forced coolingContacts for level control stoppersECOwww.dape.pt | geral@dape.pt | +351 253 286 351CBS 5500 01 | CBS 7500 01 | CBS 9000 01 | CBS 11000 01 | CBS 13200 01 | cbs 16000 01 | cbs 22000 0155.0kW-220.0kWCBS 5500 01 CBS 7500 01 CBS 9000 01 CBS 11000 01 CBS 13200 01 CBS 16000 01 CBS 2200 01Item | Type 55.0 kW 75.0 kW 90.0 kW 110.0 kW 132.0 kW 160.0 kW 220.0 kWMax. input DC voltage (Voc) 790 V 790 V 790 V 790 V 790 V 790 V 790 VRecommended MPPT voltage (vmp) 500-700 V 500-700 V 500-700 V 500-700 V 500-700 V 500-700 V 500-700 VRecommend PV power input 85,0 kW 115,0 kW 135,0 kW 165,0 kW 200,0 kW 240,0 kW 330,0 kWMax. MPPT e?ciency 99% 99% 99% 99% 99% 99% 99%Number of string´s 17 23 27 33 40 48 66Rated input voltage 400~ V, 3-phase 400~ V, 3-phase 400~ V, 3-phase 400~ V, 3-phase 400~ V, 3-phase 400~ V, 3-phase 400~ V, 3-phaseInput frequency range 50~60 Hz 50~60 Hz 50~60 Hz 50~60 Hz 50~60 Hz 50~60 Hz 50~60 HzMax. motor output power 55,0 kW 75,0 kW 90,0 kW 110,0 kW 132,0 kW 160,0 kW 220,0 kWRated output voltage 400~ V, 3-phase 400~ V, 3-phase 400~ V, 3-phase 400~ V, 3-phase 400~ V, 3-phase 400~ V, 3-phase 400~ V, 3-phaseOutput frequency range 0~50/60 Hz 0~50/60 Hz 0~50/60 Hz 0~50/60 Hz 0~50/60 Hz 0~50/60 Hz 0~50/60 HzRated output current 160,0 A 195,0 A 230,0 A 290,0 A 300,0 A 375,0 A 500,0 AMax. e?eciency 97% 97% 97% 97% 97% 97% 97%Protection class I I I I I I IProtection degree IP54 IP54 IP54 IP54 IP54 IP54 IP54Environment temperature (-)25°C to (+)65°C (-)25°C to (+)65°C (-)25°C to (+)65°C (-)25°C to (+)65°C (-)25°C to (+)65°C (-)25°C to (+)65°C (-)25°C to (+)65°CCooling Forced cooling Forced cooling Forced cooling Forced cooling Forced cooling Forced cooling Forced coolingDimension (LxWxH) 1900x950x600 (mm) 1900x950x600 (mm) 1900x950x600 (mm) 1900x950x600 (mm) 1900x950x600 (mm) 1900x950x600 (mm) 2300x950x800 (mm)Weight 180,0 kg 180,0 kg 190,0 kg 190,0 kg 260,0 kg 260,0 kg 280,0 kgShipping dimension (LxWxH) 2000x1000x700 (mm) 2000x1000x700 (mm) 2100x1000x700 (mm) 2100x1000x700 (mm) 2400x1000x750 (mm) 2400x1000x750 (mm) 2400x1000x850 (mm) DC INPUT AC INPUT AC OUTPUT SYSTEM GENERAL DATAAcess to the contacts Panel’s controlSystem data display Source selectorsolar pumps controller water that comes from the sun
Most popular related searches