Doble Engineering Company
- Home
- Companies & Suppliers
- Doble Engineering Company
- Downloads
- Doble - TDR9100 - Circuit Breaker ...
Doble - TDR9100 - Circuit Breaker Diagnostics Brochure
TDR9100CIRCUIT BREAKER TEST SYSTEMThe TDR9100 is the essential test set for your circuit breaker testing - providing Main Contact timing, Motion, Resistance and Capacitance measurements with the flexibility to double or triple your useable channels.The TDR9100 is a state-of-the-art Circuit Breaker Test System engineered to test all types of circuit breakers with efficient and accurate performance measurements. Use this inclusive, rugged and field-portable instrument for simple and complex testing of circuit breakers.TDR9100 Benefits:• Test set features up to 4 breaks per phase, 3 motion channels and 6 event channels• Testing Flexibility - The test set can be ganged as a set of 2 or 3 units effectively doubling or tripling your usable channels and main contacts for up to 12 breaks per phase.• Supports 20kHz sampling rate and expanded analog measurement ranges• Rugged and Reliable - The TDR9100 is a single box solution, providing the accuracy of a laboratory instrument with durability for field use.• Complete Test Reports - provided in MS Excel™ format• User-friendly software interface - The new T-Doble Software features an intuitive control panel for quick, efficient and simple testing of circuit breakers.• High Accuracy Motion Recording - A patented digital rotary and linear transducer provide early diagnosis of mechanical problems.• Includes Pre-insertion resistor and Capacitance measurement capability• Detects main contact and resistor contact timing errors• Supports Doble Current Probe and other analog transducers• Immune to Interference - The accuracy of test results is unaffected by the severe conditions of electrostatic and electromagnetic interference that are normally present in harsh substation environments.• Controlled by user supplied PC®The TDR9100 comes with T-Doble Software for improved data management capability.• Intuitive and clear: easy-to-use test plans and test results• Data can be plotted, overlaid, analyzed and printed• Will import all TRX and T-Doble test result data and test plans• Trip (O)• Close (C)• Reclose (O-0.3s-C)• Tripfree (CO)• O-CO• O-0.3s-CO• First Trip (O)• Slow Close (C)TDR9100 Features:TDR9100 controls circuit breaker trip and close commands and supports the following operations: TDR9100 Optional Accessories:• O.C.B. & EHV Contact Cable Sets• Analog/Auxiliary Cable Kit - T9940• Doble Current Probe (20 A / 200 A Ranges)• 10’ or 60’ Instrument Ganging Cable• Full line of Motion Transducers & Adapters• Mechanical Adapter Clamp Set• External USB Printer – Model P1• Safety Switch Bypass Flag TDR9100 Technical Specifications:Main/Resistor Contact TimingOCB Configuration: 3 Contacts EHV Configuration: 12 Contacts - up to 36 with ganged unitsResolution: 50 µs / at max sample rateMaximum Sample Rate 20 kHz Resistor Detection Range: 10 O to 10 kOResistor (Insertion) Value Range: 10 to 7000 O Measurement Accuracy: Resistor Value: ± 10% Capacitor Value: ± 10%Capacitance Detection Range: 75 to 10,000 pF Voltage Isolation to Chassis: 1.0 kVTrip/Close Initiation ControlMaximum Input Current: ± 100 A Maximum Input Voltage: ± 300 V Voltage Isolation to Chassis: 1.0 kV Motion ChannelsNumber of Channels: 3 - up to 9 with ganged units Connector: 15-pin “D” Voltage Isolation to Chassis: 1.0 kV Event Channels Dual function, Analog or Auxiliary, user programmable Number of Channels: 6 - up to 18 with ganged units Analog Measurement Channels Maximum Input Voltage: ± 300 V Input Impedance: 1 MO Resolution: 12 Bit Number of Ranges: Ten - 0.2 to 300 V Analog Accuracy: ± 1% of reading, ± 1.5% full scale offset Voltage Isolation to Chassis: 1.0 kV Auxiliary Contact Channels Sense Mode: Voltage Sense/Contact Sense Maximum Input Voltage: ± 300 V Open Circuit Voltage: 30 V ± 10% Close Circuit Current: 28 mA ± 10% Voltage Isolation to Chassis: 1.0 kVDigital Linear/Rotary Motion Transducer Linear RotaryRange: 0.0 to 40.0” 0.0 to 2880.0° 0.0 to 1000.0 mmAccuracy: +/-0.1% of the value +/- 0.1% of the value +/- 0.1” max error +/- 0.1° max errorMeasurement Resolution: 0.00125” 0.09° 0.03 mmVelocity: 50 ft/s 120 rev/s max 15 m/sAcceleration: 1200 g for 50 µs max 30x106°/s2 maxGeneral Recordings: 25 seconds (all channels at max resolution) Up to 87 minutes (reduced resolution)Communication: USB or EthernetSafety: Safety Ground Remote Safety Switch Audible Indication (test in progress)Pending Certifications: CE, C-Tick, CSA CompliantPhysical Specifications:Dimensions: 24.0 X 15.5 X 8.5 in, 60.9 X 39.4 X 21.6 cmWeight: 24 lbs / 11 kgPower Supply: 100 – 240 V, 50/60 HzTemperature: 0° to 50° C operating, -25° to + 70° C storage Humidity: Up to 95% relative humidity non-condensingSpecifications are subject to change without noticeFor more information, email TDRinfo@doble.com.TOGETHER WE POWER THE WORLD®Doble Engineering Company Worldwide Headquarters85 Walnut StreetWatertown, MA 02472 USAtel +1 617 926 4900fax +1 617 926 0528www.doble.com MKT-SL-TDR9100-03/12Doble is ISO Certified Doble is an ESCO Technologies Company
Most popular related searches