Kabelwerke Villingen GmbH (KWV)

Double Insulated Single Wires For The Interconnection Of PV Systems

Double insulateD single wires for the interconnection of PV systems:solarVill® XsPV1-fapplications:SolarVill® XS is a low-cost variant of the PV1-F Photovoltaic wire used for the interconnections of the PV Modules, Panel-Strings and Inverters. The SolarVill® XS PV1-F is TÜV 2 PfG 1169/08.2007 certified. For use in fixed installation or steady movement in free motion (without tensile load) For outdoor use in wet and dry locations Highly resistant to solar radiation Not to be used as buried cableavailable sizes:Cross sectionin mm2 (AWG)Conductor construction(in mm)Nominal outer diameter inmm (inches)Copper weightkg/km (lbs/1000ft.)Cable weightkg/km (lbs/1000ft.)2.5 (14) 44 x 0.25 4.5 (0.18) 20.7 (13.91) 38 (25.53)4.0 (12) 50 x 0.30 5.0 (0.20) 33.8 (22.71) 54 (36.29)6.0 (10) 74 x 0.30 5.6 (0.22) 50.4 (33.87) 74 (49.73)10.0 (8) 74 x 0.40 6.9 (0.26) 88.1 (59.20) 119 (79.96)16.0 (6) 114 x 0.40 7.7 (0.30) 136.9 (91.99) 174 (116.92)25.0 (4) 189 x 0.40 9.3 (0.34) 229.2 (154.01) 296 (198.90)35.0 (2) 259 x 0.40 10.7 (0.42) 314.9 (211.60) 397 (266.77)features: The cable is halogen-free and does not generate corrosive or toxic gases if burned The material used is highly flame-resistant and has low smoke emissions The material used for the cable’s insulation and its jacket is highly resistant to atmospheric conditions such as UV radiation and abrasion A large temperature range allow the use under extreme weather conditions The cable has a superior flexibility for use in high mechanical load The insulation and the jacket cannot be separated – for a simplified manufacturing process Compliant with the RoHS Directive and REACH Regulation Longer life expectancy - guaranteed for 25 yearsTÜV R 60038725TÜV 2 PfG 1169/08.2007Kabelwerke Villingen gmbhColour available: blackKabelwerke Villingen gmbhAm Krebsgraben 3/178048 Villingen -SchwenningenGermanyPhone: +49 (0)7721 / 206 17-0Fax: +49 (0)7721 / 206 17-90info@kwv-vs.dewww.kwv-vs.deKabelwerke Villingen gmbhversion: 04/2011technical properties:According to PV1-F TÜV requirements: Flexible tinned conductor (class 5 - DIN EN 60228) Short-circuit strength: up to 200°C/5s Hot Set Test at 200°C Hot Pressure Test: up to 140°C Long-term behaviour Test: 20,000h at 120°C Voltage Test (online test): 10kV Nominal Voltage: [U0/U] AC 0.6/1.0kV AC Voltage Test: 6.5kV Possible Voltage up to 1.8 kV (conductor/conductor, not grounded system, unloaded circuit) Highly resistant to acid, lye, ozone and UV Halogen free Temperature range: -40°C up to +90°C (fixed) Maximum temperature at the conductor +120°C
Most popular related searches