Dale Power Solutions Ltd.
- Home
- Companies & Suppliers
- Dale Power Solutions Ltd.
- Downloads
- E200 (1-3kVA) - Single Phase High ...
E200 (1-3kVA) - Single Phase High Efficiency UPS System Brochure
Dale Power Solutions Ltd Dale Power Solutions Ltd Salter Road, Eastfield Industrial Estate, Scarborough, North Yorkshire, YO11 3DU, United Kingdom Telephone: +44 (0) 1723 583511 Email: info@dalepowersolutions.com Website: www.dalepowersolutions.com Registration No 941798 England Document ref S5264EU08rev7 Features ? High frequency, double conversion on-line technology ? Fully digital DSP control ? User friendly LCD interface ? Wide input voltage range ? Cold start function ? Advanced battery management ? Selectable ECO mode for high efficiency operation ? Automatic battery charge in UPS off mode ? Lightning and surge protection ? Short circuit and overload protection ? Automatic fan speed control with load variation ? Smart RS232 communications with monitoring software ? USB communications port included ? Optional relay or SNMP communications card ? Matching EE battery packs available ? E suffix models have no internal battery and increased E200 Series UPS Single Phase 1-3kVA 0.7PF Specifications Dale Power Solutions Ltd reserves the right to make changes in specification without notice or liability. All information is subject to Dale Power Solutions own data & is considered accurate at time of publishing. UPS Model E201(E) E202(E) E203(E) Capacity 1000VA/700W 2000VA/1400W 3000VA/2100W Input Voltage range 115V AC - 295V AC, load < 70% 160V AC - 295V AC, load > 70% Phase Single phase Frequency 46 - 54Hz ±0.5Hz or 56 - 64Hz ±0.5Hz (auto sensing) Power Factor 0.97 Output Voltage 208/220/230/240V AC ±2% Phase Single phase Frequency Range 50 / 60Hz ±0.2% (auto selected at start up) THD (Linear Load) < 3% THD (Non-Linear Load) < 6% Overload Capability >110% for 30 sec then transfer to bypass >150% for 0.3 sec then transfer to bypass Crest Factor 3:1 (max) Power Factor 0.7 Short Circuit Protection On-line mode: Inverter turns off after 5 cycles, inhibits transfer to the bypass & provides an alarm Battery Mode: Inverter turns off after 5 cycles & provides an alarm Bypass mode: AC input fuse blows or circuit breaker operates Waveform Sine wave Transfer Time 0ms (between on-line mode & battery mode) Efficiency On-line mode: >83% On-line mode: >85% Battery Model 12V valve regulated lead acid maintenance free DC Voltage 24V DC 48V DC 72V DC Battery 2x 12V / 9Ah 4x 12V / 9Ah 6x 12V / 9Ah Backup Time At Half Load 11 mins 11 mins 11 mins Backup Time At Full Load 4 mins 4 mins 4 mins Charge Current Internal Battery: 1A External Battery: 4A (E suffix) Recharge Time 90% capacity after 8 hours charging Environment Temperature 0ºC to +40ºC Relative Humidity 0 - 95% (non-condensing) Altitude 1500m maximum Storage Temperature -25ºC to +55ºC Communication Standard: RS232, USB Optional: SNMP or Relay Card LCD Display Measurements: Input/output voltage/freq, battery voltage, load power and kVA, UPS temperature Operation mode: On-line, Battery, Bypass LED Indication Green LED: Normal operation Yellow LED: Warning condition Red LED: Abnormal operation Noise level < 45dBA Safety & EMC CE marked to 2006/95/EC & 2004/108/EC Tested to EN62040-1-1:2003 & EN62040-2:2006 Weight & Dimensions Standard Unit Weight 10.0kg / E suffix 5.2kg 21.0kg / E suffix 11.0kg 25.0kg / E suffix 11.0g Dimensions (H x W x D) 215 x 144 x 361 mm 337 x 191 x 428 mm Standard Accessories Control Software Yes Yes Yes Input & Output Leads Yes Yes Yes Data Lead Yes Yes Yes User Manuals Yes Yes Yes
Most popular related searches