
Advanced Test Equipment Rentals
- Home
- Companies & Suppliers
- Advanced Test Equipment Rentals
- Downloads
- EMC Immunity Test System- Brochure
EMC Immunity Test System- Brochure
www.haefely.comHaefely is a subsidiary of Hubbell Incorporated.a brand ofEXPANDABLE TEST SYSTEMS 2 AXOS SERIESEMC IS ALL ABOUT STANDARDS. HAEFELY COVERS THEM IN JUST ONE SINGLE BOX. The standards - are you really familiar with all of them? Whether people talk about generic standards or product specific standards - stipulated by law or demanded from the manufacturer: HAEFELY has integrated all of them. Take benefit from the most modern and easy to use conducted immunity test system ever built. Welcome to the AXOS series. Domestic Industrial Medical ITWhite goods Robotics Monitoring ComputersBrown goods Welding machines Scanning PrintersHousehold Packing machines Analysing Modems Lightning devices Production lines Pumps HubsPortable tools Laboratory equipmentImplants PhonesHome automation ServersRenewable energy Telecom Transportation DefenseSolar panels Outdoor lines Automotive Component testingWindmills Repeater Motorcycles CommunicationsTurbines Switching stations Trucks VehiclesInverters Data concentrators Electric vehicles AircraftsInfrastructure Telecommunication centersCharging stations SatellitesIndoor applicancesOutdoor applicances3Expandable Test Systems THE STANDARDSIEC/EN 61000-4-5 Surge Combination Wave 1.2/50µs...8/20µs Surge events can be generated by lightning phenomena, switching transients or the activation of protection devices in the power distribution system. A surge itself is influenced by the propagation path taken so that impulses from the same event may have different forms depending upon where a measurement is taken. Combination Wave Generators (CWG) simulate a surge event in power lines close to or within buildings. Mostly the disturbances are tolerable because they are single events.IEC/EN 61000-4-4 Electric Fast Transients, EFT/Burst Industrial measurement and control equipment nearly always use conventional control units containing relays or other electro-mechanical switching devices. Fluorescent lamp ballast units, insufficiently suppressed motors (hair dryers, vacuum cleaners, drills, etc.) are found everywhere in the public power supply. All of these are primarily inductive loads which generate interference when switched on or off. EFT events, can cause microprocessor units to malfunction or reset, with corresponding disruption to normal operation.IEC/EN 61000-4-11 Voltage Dips and Interrupts Voltage failures occur following switching operations, short-circuits, response of fuses and when running up heavy loads. The quality of the electrical power supply is increasingly becoming a central topic of discussion. The interference sources in the mains, caused by electronic power control with non-linear components e.g. thyristors are used more frequently in domestic appliances such as hotplates, heating units, washing machines, television sets, economy lamps, PCs and industrial systems with speed-controlled drives.IEC/EN 61000-4-9 Pulsed Magnetic Field Under normal operating conditions, an AC current generates a steady magnetic field so that equipment, such as monitors, close to AC power lines could suffer interference. Under fault conditions, a sudden high current level can result in a short duration ma-gnetic field. Lightning strokes or short circuit fault currents in the power network can generate high level short duration magnetic fields.4 AXOS SERIESTHE STANDARDSIEC/EN 61000-4-5 Telecom Wave 10/700µs / ITU K.20, K.21, K.44, K.45 Telecommunication networks and lines are often disposed to lightning strikes and their associated effects. All telecommunication systems linked with lines in-IEC/EN 61000-4-12 Ring Wave / IEEE C62.41 Ring waves are used to simulate lightning or switching effects in domestic single or three phase supplies within an adequately protected building. The waveform has similar characteristics in both open and short circuit conditions. The ring wave is characterised as a bipolar damped oscillating wave.5Expandable Test SystemsTHE MODULAR CONCEPTWelcome to the unique design and concept of modularity designed by HAEFELY.HAEFELY is recognizing an increasing interest in testing departments to configure the required functions in compact immunity test systems more flexible than ever. For that reason HAEFELY designed a unique concept of modularity which eviscerates large additional investments for customers in the future. Moreover, constantly reduced product development times call for powerful, easy-to-operate and ready-to-use conducted immunity test systems which can be expanded in a multitude of different test applications. Customer requirements, particularly in the telecommunications and industrial electronics sector, emphasize a test system‘s ac-curacy and modularity, thus clearly pointing to easy to expand T&M equipment that is favourably priced and suitable for most of industries.The new AXOS series has been tailored to exactly meet these requirements, offering special cost advantages for T&M applications in the development, production and servicing of telecommunications, components as well as safety and industrial electro-nics. All AXOS test systems come equipped with all the hardware needed for instant upgrades by only entering optional key codes into the licence code manager of the unit. After entering the key code(s) the additional test functionalities like Surge Combination Wave, Ring Wave, Telecom Wave, EFT/Burst or Voltage Dips and Interrupts become available immediately. No direct intervention has to be done by the user at all. License Manager of the AXOS series6 AXOS SERIESAXOS5 EXPANDABLE TEST SYSTEM AXOS5 front view AXOS5 rear viewThe new AXOS5 expandable test system integrates all of the best features of several stand-alone test systems into one single economic solution. It can be individually combined either with 5 kV Surge Combination Wave, 5 kV EFT/Burst, Dips & Interrupts, along with an integrated single-phase coupling / decoupling network. This allows quick and completely automated testing to the most common IEC, EN, ANSI, IEEE and UL standards.The AXOS5 can either be operated via front panel by large colour graphic interface or remotely from the PC. The easy to use menu together with the availability of predefined test routines for different standards makes testing easy and reliable, even for less fre-quently users. Numerous additional functions such as external start/stop function allows easy integration of the test system also in customer specific test environments. All the test parameters can be varied in a broad range wide above the requirements of the standards. Together with the ability of changing test parameters during test, AXOS5 is not only the ideal product for compliance and pre-compliance testing, it is useful for monitoring & debugging function during design phase as well. A wide range of cost-efficient and user friendly coupling / decoupling networks for power lines as well as for symmetrical and asymmetrical data- and signal lines are available as options.7Expandable Test SystemsOVERVIEW FEATURES & BENEFITS? Easy to operate with manual and auto-mated test modes, software assisted test preparation, pre-defined test rou-tines and visual aided test setups ? Economic & EfficientTouch screen guarantees reduction of time and effort - Experience and know-how at a reasonable price ? Safe and reliable operation by using safety interlock, warning lamp and emergency stop functions? Voltage and current monitoring of surge impulses and EUT power pro-vides valuable feedback to the test engineer? Automatic generation of test report, including test parameters, test setup and test resultSTANDARDS? IEC/EN 61000-4-4 EFT / Burst? IEC/EN 61000-4-5 Surge Edition 2 & 3? IEC/EN 61000-4-9 Imp Magnetic Field ? IEC/EN 61000-4-11 AC Dips and Interrupts? IEC/EN 61000-4-29 DC Dips and Interrupts ? IEC/EN 61000-6-1 Generic Residential ? IEC/EN 61000-6-2 Generic Industrial ? IEC/EN 60335-1 Household ? IEC/EN 60601-1 Medical? and many moreAPPLICATIONS? Compliance & pre-compliance testing of electrical products? CE marking? Product development and debugging? Compliance testing of telecom and wireless devicesINDUSTRIES? Industrial? Residential? Components? Medical? Renewable energy? Telecom8 AXOS SERIESTECHNICAL DATA - AXOS5 GENERAL DATAControl power 85 V - 264 V50/60 HzDimensions (W x H x D)19“ / 4U(45 x 18 x 49 cm)User test storage unlimited Weight 25 kgRemote interface Ethernet, RJ45 USB for USB memory stickDisplay 7“ / 800x480 / 24 bitwith touch-screenAUX. interface D-sub 37p for external CDN, external trans-former etc.External trigger input5 V TTL Synch input BNC, 10 V – 264 V ACTrigger output 5 V TTL External start / stopinput5 V TTL, starts / stops predefined test se-quenceEUT failed input 5 V TTL Analog output 0 – 10 V, for use with external optionsWarning lamp output2 x 24 V / 1 A DC Safety circuit stops the test when unlocked IEC / EN 61000-4-4 EDITION 2 & 3 EFT / BURSTOutput voltage 0.2 – 5.0 kV ±10% at coaxial outputSpike frequency 1 Hz – 1 MHzPolarity pos / neg / alternate Burst duration 10 µs – 1 sOutput impedance 50 Ohm Burst period 1 ms – 10 sRise time 5 ns ±30% Test time 1 s– 1'000 minutesImpulse duration 50 ns ±30% at 50 Ohm50 ns –15 +100 ns at 1'000 OhmTrigger automatic, manual,external trigger inputBurst mode normal, continuous, real, randomIntegrated single phase coupling / decoupling network264 V AC / 16 A220 V DC / 10 A9Expandable Test SystemsIEC / EN 61000-4-5 EDITION 2 & UPCOMING EDITION 3 SURGE COMBINATION WAVEOutput voltage 0.2 – 5.0 kV ±10% Output current 0.1 – 2.5 kA ±10%Voltage rise time 1.2 µs ±30% Current rise time 8 µs ±20%Voltage duration 50 µs ±20% Current duration 20 µs ±20%Polarity postive / negative / alternateIntegrated single phase CDN264 V AC / 16 A220 V DC / 10 AOutput impedance 2 OhmPhase sync 0 – 359° with 1° steps or asynchronous modeImpulse trigger automatic 2 s – 100 minmanualexternal trigger inputCounter preselect 1 – 1'000 / infiniteCounter 100'000Peak voltagemonitorBNC output: 1000:1display: 3 digitsPeak currentmonitorBNC output: 1 kA/Vdisplay: 3 digits IEC / EN 61000-4-11 EDITION 2 AND IEC / EN 61000-4-29 DIPS & INTERRUPTSMax. voltage 264 V AC/DC Interrupt time 0.5 period – 800 peri-ods100 µs – 1000 minutesMax. current 16 A AC/DC continuous20 A for 5 s 23 A for 3 s40 A for 3 s > 500 A inrush currentInterval time 1 period – 800 periods synch 100 µs – 1000 minutes asynchTrigger automatic manualexternal trigger inputTest time 1 s – 1000 minutes infiniteInterruptdip level0%0% – 99% with external voltage sourcePhase sync 0 – 359° 16 / 40 / 50 / 60 Hzasynchronous modeRMS voltage monitorBNC output: 100:1display: 4 digitsRMS current monitorBNC output: 10 A/Vdisplay: 4 digits10 AXOS SERIESOVERVIEW OF AXOS5 SERIES**additional antenna coil "MSURGE-A" required*external voltage dips transformer "DIP 116" required? Activated by default ? Optionally available by activation via key codeAXOS5 Compact Test System Article no. 2490400 Surge 1.2/50µs...8/20µs IEC/EN 61000-4-5EFT/Burst IEC/EN 61000-4-4Voltage Dips IEC/EN 61000-4-11*Magnetic FieldIEC/EN 61000-4-9**AXOS5 Surge Test System Article no. 2490401 Surge 1.2/50µs...8/20µs IEC/EN 61000-4-5EFT/Burst IEC/EN 61000-4-4Voltage Dips IEC/EN 61000-4-11*Magnetic FieldIEC/EN 61000-4-9**AXOS5 EFT/Burst Test System Article no. 2490402 Surge 1.2/50µs...8/20µs IEC/EN 61000-4-5EFT/Burst IEC/EN 61000-4-4Voltage Dips IEC/EN 61000-4-11*Magnetic FieldIEC/EN 61000-4-9**AXOS5 Dips Test System Article no. 2490403 Surge 1.2/50µs...8/20µs IEC/EN 61000-4-5EFT/Burst IEC/EN 61000-4-4Voltage Dips IEC/EN 61000-4-11*Magnetic FieldIEC/EN 61000-4-9**SCOPE OF SUPPLY - OPTIONS & ACCESSORIES11Expandable Test SystemsSCOPE OF SUPPLY AXOS5 Compact Immunity Test System 2490400AXOS5 Surge Test System 2490401AXOS5 EFT/Burst Test System 2490402AXOS5 Voltage Dips Test System 2490403Qty. 1 Immunity Test System AXOS5Qty. 1 Mains Cable Qty. 1 User ManualQty. 1 Certificate of CalibrationOPTIONS AND ACCESSORIESFP-EFT 32M 3-Phase CDN EFT/Burst 32 A / 690 V 2490170FP-EFT 100M2 3-Phase CDN EFT/Burst 100 A / 690 V 2495860IP4A Capacitive Coupling Clamp for EFT/Burst 2491300FP-SURGE 32A Automatic 3-Phase CDN Surge 32 A / 690 V 2490700FP-SURGE 100M2 3-Phase CDN Surge 32A / 690 V 2490180PCD 121 Symmetrical Data & Control Line Coupler 2498010PCD 126A Asymmetrical Data & Control Line Coupler 2498030DEC 5 Symmetrical Data & Control Line Decoupler 2490141DEC 6 Symmetrical Data & Control Line Decoupler 2490151DEC 7 Asymmetrical Data & Control Line Decoupler 2490161DIP 116 Automatic Dips Transformer 16 A 40/70/80% 2490410MSURGE-A Magnetic Field Test IEC / EN 61000-4-9 2490441VTM 15000 Isolation Test 1.2/50 us up to 10 kV 2499960VTM 15000/05 Isolation Test 1.2/50 us up to 10 kV / 0.5J 2499692PDP 8000 HV Differential Probe 1000:1 for Surge 2499911CP 101 Current Probe Model for Surge 2499931ES External Emergency Stop Switch P12 4700751WL External Warning Lamp P12 4700750Calibration Accredited Calibration AXOS5 2490420Surge Key Code Key Code for Surge extension AXOS5 4700814EFT/Burst Key Code Key Code for EFT/Burst extension AXOS5 4700815Dips Key Code Key Code for Voltage Dips extension AXOS5 470081612 AXOS SERIESAXOS8 EXPANDABLE TEST SYSTEMThe new AXOS8 expandable test system integrates all of the best features of several stand alone test systems into one single economic solution. It can be individually combined either with 7 kV Surge Combination Wave, 7 kV Ring Wave, 7 kV Telecom Wave*, 5 kV EFT/Burst or Dips & Interrupts, along with an integrated single-phase coupling / decoupling network. This allows quick and completely automated testing to the most common IEC, EN, ANSI, ITU, IEEE and UL standards.The AXOS8 can either be operated via front panel by large colour graphic interface or remotely from the PC. The easy to use menu together with the availability of predefined test routines for different standards makes testing easy and reliable, even for less frequently users. Numerous additional functions such as external start/stop function allows easy integration of the test system also in customer specific test environments. All the test parameters can be varied in a broad range wide above the requirements of the standards. Together with the ability of changing test parameters during test, AXOS8 is not only the ideal product for compliance and pre-compliance testing, it is useful for monitoring & debugging function during design phase as well. A wide range of cost-efficient and user friendly coupling / decoupling networks for power lines as well as for symmetrical and asymmetrical data- and signal lines are available as options.AXOS8 front view AXOS8 rear view*external Telecom Wave Modul "TW8" required 13Expandable Test SystemsOVERVIEWFEATURES & BENEFITS? Easy to operate with manual and automated test modes, software as-sisted test preparation, pre-defined test routines and visual aided test setups ? Economic & EfficientTouch screen guarantees reduction of time and effort - Experience and know-how at a reasonable price ? Safe and reliable operation by using safety interlock, warning lamp and emergency stop functions? Voltage and current monitoring of surge impulses and EUT power provides valuable feedback to the test engineer? Automatic generation of test report, including test parameters, test setup and test resultAPPLICATIONS? Compliance & pre-compliance testing of electrical products? CE marking? Product development and debugging? Compliance testing of telecom and wireless devices? OvertestingSTANDARDS? IEC/EN 61000-4-4 EFT / Burst? IEC/EN 61000-4-5 Surge Edition 2 & 3 (1.2/50µs...8/20µs)? IEC/EN 61000-4-5 Surge (10/700µs)*? IEC/EN 61000-4-9 Magnetic Field** ? IEC/EN 61000-4-11 AC Dips and Interrupts***? IEC/EN 61000-4-12 Ring Wave? IEC/EN 61000-4-29 DC Dips and Interrupts ? IEC/EN 61000-6-1 Generic Residential ? IEC/EN 61000-6-2 Generic Industrial ? IEC/EN 60335-1 Household ? IEC/EN 60601-1 Medical? IEC/EN 60950? EN 55024? IEEE C62.41? ITU K.20, K.21, K.44, K.45* in combination with external Telecom Wave Modul "TW8" ** additional antenna coil "MSURGE-A" required *** external voltage dips transformer "DIP 116" required14 AXOS SERIESGENERAL DATAControl power 85 V - 264 V50/60 HzDimensions (W x H x D)22“ / 6U(45 x 27 x 50 cm)User test storage unlimited Weight 30 kgRemote interface Ethernet, RJ45 USB for USB memory stickDisplay 7“ / 800x480 / 24 bitwith touch-screenAUX. interface D-sub 37p for external CDN, external trans-former etc.External trigger input5 V TTL Synch input BNC, 10 V – 264 V ACTrigger output 5 V TTL External start / stopinput5 V TTL, starts / stops predefined test se-quenceEUT failed input 5 V TTL Analog output 0 – 10 V, for use with external optionsWarning lamp output2 x 24 V / 1 A DC Safety circuit stops the test when unlockedIEC / EN 61000-4-4 EDITION 2 & 3 EFT / BURSTOutput voltage 0.2 – 5.0 kV ±10% at coaxial outputSpike frequency 1 Hz – 1 MHzPolarity pos / neg / alternate Burst duration 10 us – 1 sOutput impedance 50 Ohms Burst period 1 ms – 10 sRise time 5 ns ±30% Test time 1 s– 1000 minutesImpulse duration 50 ns ±30% at 50 Ohm50 ns –15 +100 ns at 1000 OhmTrigger automatic, manual,external trigger inputBurst mode normal, continuous, real, randomIntegrated single phase coupling / decoupling network264 V AC / 16 A220 V DC / 10 AIEC / EN 61000-4-5 EDITION 2 & UPCOMING EDITION 3 SURGE COMBINATION WAVEOutput voltage 0.2 – 7.0 kV ±10% Output current 0.1 – 3.5 kA ±10%Voltage rise time 1.2 us ±30% Current rise time 8 us ±20%Voltage duration 50 us ±20% Current duration 20 us ±20%Polarity pos / neg / alternate Integrated single phase CDN264 V AC / 16 A220 V DC / 10 AOutput impedance 2 OhmsPhase sync 0 – 359° with 1° steps or asynchronous modeImpulse trigger automatic 2 s – 100 minmanualexternal trigger inputCounter preselect 1 – 1000 / infiniteCounter 100000Peak voltagemonitorBNC output: 1000:1display: 3 digitsPeak currentmonitorBNC output: 1 kA/Vdisplay: 3 digits TECHNICAL DATA - AXOS815Expandable Immunity Test Systems IEC / EN 61000-4-5 Telecom Wave / ITU K.20, K.21, K.44, K.45Max. voltage 0.2 - 7.0 kV ± 10% Source impedance / coupling15 Ohm 40 Ohm40 Ohm gas arrestersFront time OC 10 µs ± 30% Outputs 1 x 15 Ohm direct4 x 40 Ohm direct 4 x 40 Ohm gas arrestersDecay time OC 700 µs ± 20% Impulse output Banana connectorUndershoot OC < 30% Impulse input HV connectorFront time SC 5 µs ± 20% Transitions V, PolarityDecay time SC 320 µs ± 20% Number of events1 - 10'000Undershoot SC < 30% Repetition rate up to 30 / min.Polarity Positive / negative /alternateWeight 10 kg IEC / EN 61000-4-12 AND IEEE C62.41 Ring Wave Max. voltage 0.2 - 7.0 kV ± 10% Repetition rate Up to 30 pulses / minFrequency 100 kHz Polarity Positive / negative / alternateRise time OC 0.5 µs Floating output Max. 460 V / ACRise time SC 1 µs Phase sync accuracy± 1°Impedance 12 Ohm, 30 Ohm Damping rate 60% of previous peakIEC / EN 61000-4-11 EDITION 2 AND IEC / EN 61000-4-29 DIPS & INTERRUPTSMax. voltage 264 V AC/DC Interrupt time 0.5 period – 800 periods100 µs – 1000 minutesMax. current 16 A AC/DC continuous20 A for 5 s 23 A for 3 s40 A for 3 s > 500 A inrush currentInterval time 1 period – 800 periods synch 100 µs – 1000 minutes asynchTrigger automatic manualexternal trigger inputTest time 1 s – 1000 minutes infiniteInterruptdip level0%0% – 99% with external voltage sourcePhase sync 0 – 359° 16 / 40 / 50 / 60 Hzasynchronous modeRMS voltage monitorBNC output: 100:1display: 4 digitsRMS current monitorBNC output: 10 A/Vdisplay: 4 digits16 AXOS SERIESOVERVIEW OF AXOS8 SERIES* in combination with external Telecom Wave Modul "TW8" ** external voltage dips transformer "DIP 116" required *** additional antenna coil "MSURGE-A" requiredAXOS8 Compact Test System Article no. 2490800Surge 1.2/50µs...8/20µs IEC/EN 61000-4-5 Telecom Wave 10/700µs* IEC/EN 61000-4-5 & ITU Ring Wave IEEE C62.41EFT/Burst IEC/EN 61000-4-4Voltage Dips IEC/EN 61000-4-11*Magnetic FieldIEC/EN 61000-4-9**AXOS8 Surge Test System Article no. 2490810Surge 1.2/50µs...8/20µs IEC/EN 61000-4-5 Telecom Wave 10/700µs* IEC/EN 61000-4-5 & ITU Ring Wave IEEE C62.41EFT/Burst IEC/EN 61000-4-4Voltage Dips IEC/EN 61000-4-11*Magnetic FieldIEC/EN 61000-4-9**AXOS8 EFT/Burst Test System Article no. 2490830Surge 1.2/50µs...8/20µs IEC/EN 61000-4-5 Telecom Wave 10/700µs* IEC/EN 61000-4-5 & ITU Ring Wave IEEE C62.41EFT/Burst IEC/EN 61000-4-4Voltage Dips IEC/EN 61000-4-11*Magnetic FieldIEC/EN 61000-4-9**AXOS8 Dips Test System Article no. 2490840Surge 1.2/50µs...8/20µs IEC/EN 61000-4-5 Telecom Wave 10/700µs* IEC/EN 61000-4-5 & ITU Ring Wave IEEE C62.41EFT/Burst IEC/EN 61000-4-4Voltage Dips IEC/EN 61000-4-11*Magnetic FieldIEC/EN 61000-4-9**17Expandable Test Systems* in combination with external Telecom Wave Modul "TW8" ** external voltage dips transformer "DIP 116" required *** additional antenna coil "MSURGE-A" required? Activated by default ? Optionally available by activation via key codeAXOS8 Ring Wave Test System Article no. 2490820Surge 1.2/50µs...8/20µs IEC/EN 61000-4-5 Telecom Wave 10/700µs* IEC/EN 61000-4-5 & ITU Ring Wave IEEE C62.41EFT/Burst IEC/EN 61000-4-4Voltage Dips IEC/EN 61000-4-11*Magnetic FieldIEC/EN 61000-4-9**AXOS8 Telecom Wave System Article no. 2490850Surge 1.2/50µs...8/20µs IEC/EN 61000-4-5 Telecom Wave 10/700µs* IEC/EN 61000-4-5 & ITU Ring Wave IEEE C62.41EFT/Burst IEC/EN 61000-4-4Voltage Dips IEC/EN 61000-4-11*Magnetic FieldIEC/EN 61000-4-9**18 AXOS SERIESSCOPE OF SUPPLY - OPTIONS & ACCESSORIESSCOPE OF SUPPLY AXOS8 Compact Immunity Test System 2490800AXOS8 Surge Test System 2490810AXOS8 EFT/Burst Test System 2490830AXOS8 Voltage Dips Test System 2490840AXOS8 Ring Wave Test System 2490820AXOS8 Telecom Wave Test System 2490850Qty. 1 Immunity Test System AXOS8Qty. 1 Telecom Wave Modul "TS 8" 10/700µs*Qty. 1 Mains Cable Qty. 1 User ManualQty. 1 Certificate of CalibrationOPTIONS AND ACCESSORIESFP-EFT 32M 3-Phase CDN EFT/Burst 32 A / 690 V 2490170FP-EFT 100M2 3-Phase CDN EFT/Burst 100 A / 690 V 2495860IP4A Capacitive Coupling Clamp for EFT/Burst 2491300FP-SURGE 32A Automatic 3-Phase CDN Surge 32 A / 690 V 2490700FP-SURGE 100M2 3-Phase CDN Surge 32A / 690 V 2490180TW 8 Telecom Wave Modul 10/700µs 4700915PCD 121 Symmetrical Data & Control Line Coupler 2498010PCD 126A Asymmetrical Data & Control Line Coupler 2498030DEC 5 Symmetrical Data & Control Line Decoupler 2490141DEC 6 Symmetrical Data & Control Line Decoupler 2490151DEC 7 Asymmetrical Data & Control Line Decoupler 2490161DIP 116 Automatic Dips Transformer 16 A 40/70/80% 2490410MSURGE-A Magnetic Field Test IEC / EN 61000-4-9 2490441VTM 15000 Isolation Test 1.2/50 us up to 10 kV 2499960VTM 15000/05 Isolation Test 1.2/50 us up to 10 kV / 0.5J 2499692PDP 8000 HV Differential Probe 1000:1 for Surge 2499911CP 101 Current Probe Model for Surge 2499931ES External Emergency Stop Switch P12 4700751WL External Warning Lamp P12 4700750* only with AXOS8 Telecom Wave Test System (2490850) 19Expandable Test SystemsOPTIONS AND ACCESSORIESSurge Key Code Key Code for Surge extension AXOS8 4700911EFT/Burst Key Code Key Code for EFT/Burst extension AXOS8 4700912 Ring Wave Key Code Key Code for Ring Wave extension AXOS8 4700913Dips Key Code Key Code for Voltage Dips extension AXOS8 4700914VALUE ADDED SERVICES? Pre- & After Sales Support ? Application Support? Commissioning? Warranty Extension? Calibration (accredited & factory)? Training and Seminars? Rental units March 2013Headquarters China (Sales & Service Office) North American OfficeHaefely Test AG HAEFELY Representative Office Hipotronics Inc.Birsstrasse 300 8-1-602, Fortune Street Haefely EMC Division4052 Basel No.67, Chaoyang Road, Chaoyang District 1650 Route 22Switzerland Beijing, China 100025 Brewster, NY 10509? + 41 61 373 41 11 ? +86 10 8578 8099 ? +1 845 279 3644? + 41 61 373 49 12 ? +86 10 8578 9908 ? +1 845 279 2467? emcsales@haefely.com ? sales@haefely.com.cn ? emcsales@hubbell-haefely.com
Most popular related searches
Stay in the loop!
Select your areas of interest to receive industry updates.