Det-Tronics - Detector Electronics Corporation is part of Carrier
EQ 3720RM Relay Module - Specification Brochure
DESCRIPTIONThe 8 Channel Relay Module is specially designed toexpand the Output capability of the Det-Tronics EagleQuantum Premier™ System.The unit is designed to provide eight relay outputchannels for use with non-supervised devices (PLCs,fans, dampers, motor control centers, etc.) or deviceswith their own supervision.System status can be determined using the trouble-shooting procedures, Eagle Quantum Safety SystemSoftware (S3) and the status indicators on the module.LED INDICATORSLEDs on the front panel of the relay module areprovided for indicating device status. The LED’s aretested upon power-up to verify their operation.The relay module has two LEDs for the device andtwo LEDs for each channel. On the device level, onegreen LED indicates power, while the other amberLED indicates a LON communication fault. For eachchannel, one red LED indicates channel activationand the other amber LED indicates that the moduleoperating voltage is low or that the module has notbeen configured (all eight channel LEDs blink).MOUNTINGThe relay module is DIN rail or direct panel mountablefor configurations requiring installation in NEMA or IPenclosures. DIN rail and mounting clip options must bespecified at the t ime of order. Refer to the“Specifications” section for mounting arrangements anddimensions.SPECIFICATION DATAEagle Quantum™ Premier8 Channel Relay ModuleEQ3720RM2.2 ©Detector Electronics Corporation 2004 8/04 90-1181DET-TRONICS®FEATURES• Expands the output capabilities of the Det-TronicsEagle Quantum Premier™ system• Individual channel LEDs indicate Active status• Provides remote output capabilities via LON/SLC• Panel or DIN rail mounting• Power LED display • Plug-in wiring connectors• RFI and EMI hardened (CE Marked)• Programmable normally energized/de-energizedcontacts• Programmable failed state on loss ofcommunication with controller (Fail on / Fail off /Hold last state).SPECIFICATIONSPOWER REQUIREMENTS— 3 watts nominal, 4 watts maximum. INPUT VOLTAGE—24 vdc nominal, 18 to 30 vdc. 10% overvoltage willnot cause damage to the equipment.RELAY CONTACT RATING—2 amperes (resistive) at 30 Vdc maximum.0.5 ampere (resistive) at 125 Vac (FM & CSA only).OUTPUT STYLE—Type "C" relay (normally open/normally closed).RESPONSE TIME—Output actuates in <0.15 second after acknowledgingan alarm command message.LON COMMUNICATION—Digital communication, transformer isolated (78.5kbps).TEMPERATURE RANGE—Operating: –40°F to +185°F (–40°C to +85°C).Storage: –67°F to +185°F (–55°C to +85°C).HUMIDITY RANGE—5 to 95% RH, non-condensing.DIMENSIONS—Refer to Figure 1.SHIPPING WEIGHT—1 pound (0.45 kilograms).CERTIFICATION—FM / CSA: Class I, Div. 2, Groups A, B, C, D (T4).Class I, Zone 2, Group IIC (T4).CENELEC/CE: ATEX/EMC Directive Compliant.0539 II 3 GEEx nC IIC T4DEMKO 03 ATEX 135246UT4 (Tamb = –40°C to +85°C).Vin = 24 vdc ±10%.Special conditions for safe use:The device shall be installed in an enclosure thatcomplies with all relevant requirements of EN 50021:1999, and provides a degree of ingress protection ofat least IP54. The device may only be installed,connected or removed when the area is known to benon-hazardous.90-11812.2 2A B C A B C A B C A B C A B C A B C A B C A B C1 6 1 61 2 3 4 5 6 7 8A B C A B C A B C A B C A B C A B C A B C A B C1 6 1 61 2 3 4 5 6 7 84.5(11.3)5.0(12.7)2.5(6.4)1.3(3.4)5.2(13.2)1.8(4.6)5.2(13.2) 1.9(4.8)4.5(11.3)C2096PANEL MOUNTING DIMENSIONS DIN RAIL MOUNTING DIMENSIONSFigure 1—Dimensions of the Relay Module in Inches (Centimeters)INSTALLATIONMOUNTING ENCLOSUREThe Relay Module must be properly installed in asuitable enclosure that is rated for the location. Theenclosure must provide space to install and wire therelay module and must also provide for ground wiretermination. Access into the enclosure must begained by using a special tool to open the enclosure.The enclosure should be rated for the temperaturerange of the location plus the temperature rise of allequipment installed inside the enclosure. Theenclosure must be rated for electrical equipment thatis going to be installed.NOTEIt is recommended to maintain a minimum of 4inches clearance between the module and otherequipment to provide adequate room for wiringand ventilation.WIRINGAll electrical connections are made to the field wiringconnectors furnished with the module. (Connectorsaccept up to a single 12 AWG wire.) Refer to Figure 2for identification of module wiring terminals.Connector P1, Terminals 1 to 624 Vdc Power Input1 — +2 — –3 — Shield*4 — +5 — –6 — Shield**Shields on power wires are optional unless requiredby local codes.Connect the module power supply to terminals 1 and2. If additional terminals are required for poweringother devices, these devices should be connected toterminals 4 and 5. Shields are to be connected toterminals 3 and 6 — chassis (earth) ground terminals. Connector P2, Terminals 1 to 6LON TerminalsBe sure to observe polarity when wiring the LON.1 — "A" side of signaling circuit for COM 12 — "B" side of signaling circuit for COM 14 — "A" side of signaling circuit for COM 25 — "B" side of signaling circuit for COM 23 & 6 — shield connections (shields required).90-11812.2 3CHANNEL 8CHANNEL 7CHANNEL 6CHANNEL 5CHANNEL 4CHANNEL 3CHANNEL 2CHANNEL 1COM654321COM 2 SHLDCOM 2 BCOM 2 ACOM 1 SHLDCOM 1 BCOM 1 ASHLDBASHLDBALON FROMPREVIOUS DEVICELON TONEXT DEVICEPOWER654321SHLD–+SHLD–+SHLD*–+SHLD*–+24 VDCINPUT VOLTAGE24 VDCINPUT VOLTAGEEQ3720RMTOEARTHGROUNDC2206COMMON ANO BNC CCOMMON ANO BNC CCOMMON ANO BNC CCOMMON ANO BNC CCOMMON ANO BNC CCOMMON ANO BNC CCOMMON ANO BNC CCOMMON ANO BNC C123456789101112131415161718192021222324* SHIELDS ON POWER WIRES ARE OPTIONAL UNLESS REQUIRED BY LOCAL CODES. NOTE: RELAY CONTACTS SHOWN IN REST (DE-ENERGIZED) STATE.Figure 2—Relay Module Wiring Terminal ConfigurationConnectors P3 and P4Unsupervised Output Ancillary Applications(Unrelated to Fire Detection/Protection)Connect external wiring to the appropriate terminalson the relay module terminal block. See Figure 2.CONFIGURATIONSetting Relay Module Network AddressOne unique network address must be assigned toeach relay module. The address is set by the 8switch DIP assembly on the relay module.When using the switches located on the relay module,the address is binary coded and is the sum of allswitches placed in the “closed” position. Each discrete point of a relay module has a tagnumber and a descriptor for unique identification.Det-Tronics S3 Safety System Software is used fordevice configuration. The following shows theminimum software/firmware releases:ORDERING INFORMATION When ordering, please specify:EQ3720RM 8 Channel Relay ModuleOptions Panel MountDIN Rail MountFor additional information or for assistance indesigning a system to meet the needs of a specificapplication, please contact:Detector Electronics Corporation6901 West 110th StreetMinneapolis, Minnesota 55438 USAOperator: (952) 941-5665 or (800) 765-FIRECustomer Service: (952) 946-6491Fax: (952) 829-8750Web site: www.detronics.comE-mail: detronics@detronics.comREGISTERED BY UL AND BSINO. A2305 • NO.25826ISO 9001REGISTERED FIRMREGIS TEREDFIRMDetector Electronics Corporation6901 West 110th Street • Minneapolis, Minnesota 55438 • Operator (952) 941-5665 or (800) 765-FIRECustomer Service (952) 946-6491 • Fax (952) 829-8750 • www.detronics.com • E-mail: detronics@detronics.comController Version S3 Version2.01 2.8.0.0
Most popular related searches
Stay in the loop!
Select your areas of interest to receive industry updates.