
Gantner Instruments Environment Solutions GmbH
e.reader Series - Brochure
Gantner Instruments Test & Measurement GmbH ? www.gantner-instruments.com ? office@gantner-instruments.com Montafonerstraße 8 ? A-6780 Schruns / Austria ? T +43 (0) 5556 73784-410 ? F +43 (0) 5556 73784-419 Industriestraße 12 ? D-64297 Darmstadt / Germany ? T +49 (0) 6151 95136-0 ? F +49 (0) 6151 95136-26 e.reader Intelligent Data Logger Order Information: Product Article No. e.reader 511373 Configuration software e.commander 234476 Accessories Ethernet crossover cable 496524 8 analog inputs Voltage, current, resistance measurement, Pt100/Pt1000, and power supply for external sensors Analog/digital conversion Resolution of 19 bit, sample rate 1 s up to 24 h 6 digital in/outputs and 2 relays outputs Status, counter, frequency measurement Data memory with individual logging interval 128 MB flash, 16 MB RAM, 1 s up to 24 h individual per channel Low power consumption in power sleep mode 50 mW/200 mW at a sample rate of 10 min /10 s Flexable communications RS485, RS232, Ethernet TCP/IP Modem: FTP via PPP, GPRS via VPN Tunnel FTP client and FTP server email generator with data attachment Additional Features • Accuracy up to 0.01 % (depends on the range) • Power supply 10 to 30 VDC • Temperature range -20 °C up to + 60 °C • Pluggable screw terminals for field, power and communication connection up to 1.5 mm2 • DIN rail mounting (EN 50022 rail) • Electromagnetic Compatibility according IEC 801-2/-3 The intelligent data logger e.reader is designed to acquire 8 analog voltage, current, resistance or Pt100/Pt1000 signals. Additionally 6 digital in/outputs and 2 relays outputs are available. Data access, I/O expansion, and configuration can be done via any of the communication interfaces RS 485 (3x), RS 232, or Ethernet. Configurable logging intervals from 1s up to 24h and measurements can be logged into a 16 MB RAM or a 128 MB flash memory. A selectable sleep mode causes the logger will wake up for one measurement and go to sleep again after storing the results. This extremely low power usage and make the unit great for autonomous applications. Built-in PAC functionality provides complete programmability with built-in functions like sequencing, controlling mathematics and Boolean combinations. I/O expansion is possible by adding any standard e.bloxx modules on the built-in RS-485 bus interface. Gantner Instruments Test & Measurement GmbH ? www.gantner-instruments.com ? office@gantner-instruments.com Montafonerstraße 8 ? A-6780 Schruns / Austria ? T +43 (0) 5556 73784-410 ? F +43 (0) 5556 73784-419 Industriestraße 12 ? D-64297 Darmstadt / Germany ? T +49 (0) 6151 95136-0 ? F +49 (0) 6151 95136-26 e.reader Technical Data Valid from August 2007. Specification subject to change without notice. DB_EREADER_E_13.doc Digital In-/Outputs Number 6 Inputs Functionality Status, counter, frequency Input voltage max. 30 VDC Input current max. 1.5 mA Input frequency 1 kHz Outputs Functionality Process- or host controlled Contact Open Collector Output voltage max. 30 VDC Output current max. 100 mA Output frequency max. 100 Hz Power supply and power consumption Power supply 10 up to 30 VDC over voltage and overload protection Power consumption at Sample rate of 10 min approx. 50 mW Sample rate of 1 min approx. 150 mW Sample rate of 10 s approx. 200 mW Sample rate of 1 s approx. 4 W Mechanical Case Aluminium and ABS Dimensions (W x H x D) 235 x 90 x 83 mm (9.25 x 3.54 x 3.27 in) Weight 800 g (1.76 lb) Protective system IP20 Mounting DIN EN-rail Environmental Operating temperature -20 °C up to +60 °C Storage temperature -40 °C up to +85 °C Relative humidity 5 % up to 95 % at 50 °C non condensing Communication interfaces RS485 3 1 Slave 1Master and Slave 1 Master for connection of additional modules RS232 1 Ethernet TCP/IP 1 Data format 8E1, 8N1, selectable Protocols ASCII, Modbus-RTU, Gantner LocalBus (binary), PPP Baudrate Local Bus up to 1500000 Baud others 2400 up to 115200 Baud Analog/Digital Conversion Resolution 19 bit in numbers 0.003 up to 0.01 % range dependent sample rate 1 s up to 24 h Conversion method Sigma-Delta Analog Inputs Number 8 Repeatability 0.003 % typical (within 24 h) Measurement Range Accuracy Resolution Voltage ±10 V ±2 mV 40 µV (input impedance 100M?) ±5 V ±1 mV 20 µV ±1 V ±0.2 mV 4 µV ±100 mV ±20 µV 0.4 µV ±10 mV ±10 µV 0.04 µV Current 25 mA ±4 µA 80 nA (internal shunt 100 ?) 1 mA ±0.2 µA 4 nA Resistance 20 k? ±5 ? 0.25 ? (2, 4-wire, I = 0.5 mA) 4 k? ±1 ? 0.05 ? 2 k? ±0.6 ? 0.03 ? RTD (2-, 4-wire) Pt100 (-200 to +850 °C) ±0.5 °C 0.1 °C Pt100 (-200 to +250 °C) ±0.2 °C 0.01 °C Pt1000 (-200 to +850 °C) ±1 °C 0.1 °C Pt1000 (-200 to +140 °C) ±0.3 °C 0.01 °C Linearity deviation 0.01 % of the final value Temperature influence on zero 10 µV / 10 K on sensitivity 0.02 % / 10 K Relay Outputs Number 2 Functionality normal open Current max. 1 A Voltage max. 60 VDC Data Memory Flash (non volatile) 128 MByte RAM (volatile) 16 MByte Logging interval 1 s up to 24 h individual per channel
Stay in the loop!
Select your areas of interest to receive industry updates.