CertainTeed Corporation

Flintlastic - SA NailBase for Self-Adhering System Brochure

C e r t a i n Te e dSelf-Adhering SBS Modified BitumenRoof System for Low Slope RoofsAfter more than a century of making roofingmaterials that really last, CertainTeed stands strong.In fact, we’re rated #1 with America’s buildingand remodeling professionals.So whether you have a residential or commercialproject, you can turn to CertainTeed withconfidence. We’ve been around a long time, and ourexpertise goes into giving you better products.We manufacture complete systems and protectyou with strong warranties. We use the highestquality materials, and that makes for betterroofs — not to mention lower life-cycle costs.It’s all a part of our promise to you.Quality made certain. Satisfaction guaranteed.™12Goes down fast. Stays on strong.Flintlastic® SA performs in all the right ways.What’s more important to you? Speed of installation,durability or appearance? The Flintlastic SA(self-adhering) SBS modified bitumen low slope roof-ing system is a premium performer in all these areas.What is the SA system?With high-quality materials bottom to top,components of the Flintlastic SA system include:Flintlastic® SA NailBase (mechanically attached)Flintlastic® SA PlyBase (self-adhering)Flintlastic® SA Mid Ply (self-adhering)Flintlastic® SA Cap (self-adhering)Flintlastic® SA Cap FR (fire-rated, self-adhering)What are the advantages?No torches, no hot asphalt, no fumes and no mess —all of which means application is much cleaner andfaster. Plus, equipment needs are minimal. Theseadvantages are even more amazing considering thelong system life you can expect.Where can I use it?These products are flexible: They work well on bothcommercial and residential roofs in three-ply ortwo-ply applications, depending on the roof’s require-ments. Large jobs or small, Flintlastic SA can be usedanywhere you want a low slope roof that will last.What about colors?Now you can color coordinate a low slope roof to anadjacent shingle roof. Flintlastic SA is available incolors to complement the most popular CertainTeedshingles. Please refer to the CertainTeed CommercialRoof Systems Manual for product data sheets andcomplete specification details. Product applicationmust comply with CertainTeed installation instructions.The Flintlastic SA Family of ProductsFlintPrime™ SA is a premium, specially engineered,water-based, solvent-free primer for wood, metalor concrete. It is designed to enhance the adhesionof self-adhesive roofing membranes. Available in1-gallon cans and 3.5-gallon buckets.FlintBond™ SBSModified BitumenAdhesive is a premiumgrade adhesive,available in trowel,brush and caulkgrade. With FlintlasticSA membranes, thetrowel and caulk grade are used for endlap, sidelapbead and vertical flashing details. Available in 3.5-gal-lon buckets, 5-gallon pails and 10.3-oz caulk tubes.Every professional roofer is familiar with the toolsneeded to complete a roof installation, but just as arecap, specific tools you’ll need to install Flintlastic SAinclude:• Heavy, weighted roller for pressing the membraneinto place.• Suitable trowel for applying adhesive to flashingdetails.• Roofer’s knife with hooked blade.• Long-handled (standing) roller with 1/8"-1/4" nap forapplying primer (1/8" nap for smooth surfaces, 1/4"nap for more porous surfaces).• Caulk gun for applying beads of FlintBond adhesive.• Hand-held hot air welding gun such as the LeisterTriac™ (110 volt power required) or Primus SievertPNS-4™ Hot Air Kit.• Seam probing tool to check for small voids.Burnt Sienna Colonial Slate Heather Blend Moiré BlackResawn Shake Weathered Wood White CoolStar™3Important Application Considerations• Do not attempt application if ice, snow, moisture ordew are present. Bonding substrates must be clean,dry and free of dust or other inhibitors of properadhesion. Ambient temperature must be 50ºFor above.• Store Flintlastic SA rolls indoors on pallets, protectedfrom the elements. Rolls that are improperly storedor have been warehoused for prolonged periods oftime may lose their tack.• Do not apply membrane that has been improperlystored, exposed to moisture, or has lost its tack.If the material isn’t bonding, STOP the application• Always remember to put safety first and follow allOSHA safety guidelines with any roofing installation.• Substrates must be free of dust, dirt, oil, debrisand moisture.• Primer, if used, must be applied at the specified rateand must be allowed to thoroughly dry.• Work with manageable lengths of Mid Ply and Capfor the particular job. Where appropriate, cut rollsinto 1/3- or 1/2-roll lengths and allow material torelax prior to installation.• In cooler weather, a hand-held hot air welding guncan be used to warm the sidelap areas and improveadhesion (prior to application of the FlintBond SBSModified Bitumen Adhesive).• Use caution with the weighted roller at endlapareas. Don’t squeeze out too much adhesive.• When applying Mid Ply (or PlyBase) directly tosubstrate, design adequate roof ventilation into thesystem through the use of roof relief vents.• Do not mix Flintlastic SA membranes with othertypes of roof membranes. Flintlastic SA membranesare specifically designed to be applied together.The permanent top film of the Mid Ply, PlyBase andNailBase cannot receive torching, hot asphalt orother non self-adhering application methods. TheFlintlastic SA Cap (or SA Cap FR), PlyBase and MidPly cannot be applied to any surfaces other than asdescribed herein.• Do not use cold adhesives with Flintlastic SAmembranes other than for flashing details and capsheet overlaps as described herein.• Refer to the CertainTeed Commercial Roof SystemsManual for complete requirements.• When applying Flintlastic SA on slopes exceeding1" in 12", membranes shall be back nailed. Whenapplied parallel to the slope, Flintlastic SA shall beblind-nailed at end laps 2" in from top edge, 6" o.c.through tin discs and to wood nailers. See GeneralRequirements Section of the CertainTeedCommercial Roof Systems Manual for details.Deck PreparationCertainTeed recommends the use of Flintlastic SANailBase base sheet in conjunction with allself-adhering membrane roof installations. FlintlasticSA NailBase can be mechanically attached to nailablesubstrates or applied using hot asphalt (non-nailablesubstrates). For non-nailable substrates where useof hot asphalt to adhere the base sheet may not beappropriate, Flintlastic SA Mid Ply or Flintlastic SAPlyBase may be used in lieu of Flintlastic SA NailBaseon surfaces properly primed with FlintPrime™ SA.However, note that without the use of a base sheet,the membrane may be difficult to later remove(if necessary) and certain UL and FM listings for theproducts may not apply. Prior to application ofFlintlastic SA products, ensure roofs have positivedrainage. Consult the local building official forminimum slope and drainage requirements.Application of Flintlastic SA NailBaseBeginning at the low point of the roof, mechanicallyfasten Flintlastic SA NailBase to nailable deck usingappropriate fasteners (see fasteners chart below).Start with an appropriate roll width (1/3 or 1/2 roll)to accommodate offsetting of sidelaps of subsequentlayers of Mid Ply and/or Cap sheet. Install so that noside-laps areagainst the flowof water. A minimumfastening pattern is every9" on center on sidelaps and every 18" on center intwo staggered rows in the field of the sheet.Standard (Round Head) Roofing Nails and Cap (Note: CertainTeed does not permit the use of plastic caps)For use with Base Sheet, Flash/Termination Bar on Plywood Decks, Non Veneer Decks, Wood Plank DecksLarge Head Roofing NailsFor use with Base Sheet, Flash/Termination Bar on Plywood Decks, Non Veneer Decks, Wood Plank DecksBase Sheet Fasteners for some Cementitious Roof DecksFor use with Base Sheet on Light Weight Insulation Concrete, Poured GypsumSelf-Locking FastenersFor use with Base Sheet on Cement/Wood FiberPrime non-nailable substrates such as concreteusing FlintPrime SA water-based primer. Allow to drythoroughly, but not more than 4 hours to retaintack-enhancing properties. Apply SA NailBase usingASTM Type III or IV hot asphalt* at the rate of 25 lbs.per 100ft2, or self-adhere SA PlyBase (or Mid Ply).Overlap base sheet sidelaps 2" and endlaps 4".Offset endlaps a minimum of 3'. Turn base sheetover fascia and fasten. Do not leave installed baseexposed. Cover in the same day with Flintlastic SAMid Ply and/or Flintlastic SA Cap (or SA Cap FR).Don’t leave the installed Flintlastic SA NailBaseexposed to the weather; cover with Flintlastic SA Capthe same day.Application of Flintlastic SA Mid Plyor PlyBaseNote: Proceed to “Before Installing Flintlastic SA Cap(or SA Cap FR)” if installing a 2-ply system.Before installing Flintlastic SA Mid Ply (or PlyBase),sweep the underlying base sheet or primed surface toremove any dust, dirt or sand particles that couldinterfere with adhesion.Apply Mid Ply (or PlyBase) over installed Flintlastic SANailBase or, for non-nailable decks such as concrete,properly primed substrates (see above). Surface mustbe dry and free from dust or dirt. Start Mid Ply (or PlyBase) application at the low pointof the roof with appropriate roll width to offset sidelaps18" from sidelaps of base sheet. Install flush to roofedge if over base sheet, otherwise turn the Mid Ply(or PlyBase) over the fascia minimum 2" and secure.Design layout so that no sidelaps are against the flowof water.Cut rolls into manageable lengths. Fold the mem-brane back halfway lengthwise to remove the splitrelease film. Press membrane securely into place,and repeat with the opposite half of the membrane.Use a heavy, weighted roller over the entire surface ofthe Flintlastic SA Mid Ply (or PlyBase) membrane tosecure the membrane. Work outwards to eliminatevoids. Overlap sidelaps of subsequent Mid Ply (or PlyBase)membrane lengths 2" and endlaps 6". Offset (stagger)endlaps minimum 3'. Cut endlaps at opposingdiagonal corners at a 45° angle approx. 2" from thecorners to minimize “T”-seams. Apply a bead or smalltrowel dab (quarter size) of FlintBond™ SBS ModifiedBitumen Adhesive, trowel or caulk grade, at theedge of the angled cut to avoid a capillary. Use of ahand-held hot air gun at the joint area prior to rollingthe membrane will maximize adhesion. In areas proneto cold temperatures, snow and freeze-thaw cycles,it may be more effective to use the hot air gun to formjoints, and to completely fill all mole holes with asphaltthat has been slightly melted using the gun. It isrecommended to apply a bead of FlintBond SBSModified Bitumen Adhesive, caulk grade, at all Mid Ply(or PlyBase) side and endlaps to eliminate a capillary.Don’t leave the installed Flintlastic SA Mid Ply(or PlyBase) exposed to the weather; cover withFlintlastic SA Cap the same day.*Use Type III asphalt for slopes under 3" per foot; Type IV asphalt for slopes over 3" per foot. Spot mopping may be appropriate. Consult CertainTeed.4Before Installing Flintlastic SA Cap(or SA Cap FR)If roof edge detail utilizes edge metal, proceed asfollows. If Mid Ply or (PlyBase) has been applied,install minimum 26 gauge edge metal using appropri-ate fasteners, and set entirely in a uniform 1/8"-1/4"thick troweling of FlintBond SBS Modified BitumenAdhesive, trowel grade. Remove any oil from themetal surface using a vinegar and water solution.Prime the horizontal surface of the metal withFlintPrime SA and allow primer to dry. Apply a beadof caulk grade FlintBond adhesive to the edge ofthe metal where it meets the Mid Ply (or PlyBase).Proceed with Flintlastic SA Cap (or SA Cap FR)installation.If Mid Ply is not specified: Over the Flintlastic SANailBase, install a wide strip of Mid Ply to thatdimension extending 6" onto the field of the roof andflush to the roof edge, self-adhered. Install minimum26 gauge edge metal using appropriate fasteners,set entirely in a uniform 1/8"-1/4" thick troweling ofFlintBond SBS Modified Bitumen Adhesive, trowelgrade. Prime the horizontal surface of the metal withFlintPrime SA and allow primer to dry. Apply a beadof caulk grade FlintBond SBS Modified BitumenAdhesive at the roof side edge of the metal whereit meets the Mid Ply strip. Proceed with cap sheetinstallation.Similarly, complete your sheet metal flashinginstallation using cut Mid Ply strips at all flashingdetails prior to flashing application. Seal edges ofMid Ply flashing strips with a bead of FlintBond.See “Typical Construction Details,” pages 8-11,for examples. If Mid Ply has been installed as partof the system, set flanges in trowel grade FlintBondand properly fasten. All cap sheet flashings installedto transitions that overlap onto mineral surface mustbe set in a uniform troweling of FlintBond trowelgrade adhesive.Application of Flintlastic SA Cap(or SA Cap FR)Before installing Flintlastic SA Cap (or SA Cap FR),sweep the surface of the installed SA NailBase (orPlyBase) or Mid Ply clean. To install Flintlastic SA Cap(or SA Cap FR), start at the low point of the roof withan appropriate roll width to offset sidelaps from theunderlying membrane a minimum of 18". Work withmanageable lengths for proper handling. Position SA Cap (or SA Cap FR) with selvage edgerelease strip at high side of roof. Install in weather-lapped fashion, with no laps against the flow of water.Once positioned, lift and fold back (lengthwise) thelower half of the membrane. Remove the split releasefilm and press firmly into place. Then repeat with theother (high side of the roof) half of the membrane.Follow the same layout and split release film proce-dures as for Mid Ply (or PlyBase), but overlap sidelaps3" and endlaps 6". Use a heavy, weighted roller overthe entire surface of Flintlastic SA Cap (or SA Cap FR)to secure it in place and prevent voids, workingoutward from the center of the sheet.5As subsequent membrane lengths are installed,remove the selvage edge release strip just prior tooverlapping to keep the adhesive area protectedand clean. Cut endlaps at opposing diagonal cornersat a 45° angle approx. 3" from the corners to minimizeT-seams.Use FlintBond SBS Modified Bitumen Adhesive, trowelgrade, on the entire 6" width of each endlap prior tooverlapping. Apply a uniform 1/8"-1/4" troweling of theFlintBond on the entire width of the endlaps to theunderlying membrane. Install the overlapping sheet.Always apply FlintBond (extend beyond underlying lapminimum 1/4") on the entire width of any overlap whenapplying SA Cap (or SA Cap FR) over another mineralsurface such as the SA Cap (or SA Cap FR) endlap.At all vertical and other flashing points, applyFlintBond SBS Modified Bitumen Adhesive, trowelgrade, wherever there is an overlap onto mineralsurfacing.Once the membrane has had a chance to bond,check all laps and joints for full adhesion. If themembrane can be lifted at any area it is not properlyadhered. A seam probing tool can be helpful to checkfor small voids at laps. If necessary, use appropriatehand-held hot air welding tool and seam roller oran application of FlintBond to seal small unbondedareas if they exist.The Proper T-Seam Detail• Before adhering Flintlastic SA Mid Ply or Cap(or SA Cap FR) endlaps, trim the underlying sheet’slower outside corner at the end of the roll.• Follow with the overlapping sheet, trimming theupper outside corner.• Corners should be trimmed on a diagonal angle5-1/2" long from end of roll to outside edge.• Width of trim should be equal in width to the sidelapspecified (3" for Flintlastic SA Cap [or SA Cap FR]and 2" for Flintlastic SA Mid Ply [or PlyBase]).• Trimmed corners should be completely covered byapplication of succeeding courses.• Note: If using Flintlastic SA Mid Ply (or PlyBase),apply quarter-size dab of FlintBond at T-seam area.If using Flintlastic SA Cap (or SA Cap FR), theendlap should be completely set in trowelgrade FlintBond along the entire6" lap width.Rake Edge Detail• Cut selvage area at a 45° angle at all rake edges.• Apply a bead of FlintBond caulk along cut edgeto eliminate mole holes.6Typical Construction Details – Flintlastic SA 2-Ply SystemShingle TransitionVent Pipe Collar DetailDrain DetailParapet Wall7Typical Construction Details – Flintlastic SA 2-Ply SystemAlternate Parapet Wall Concrete Wall Termination with SurfaceMount FlashingScupper Detail8Typical Construction Details – Flintlastic SA 2-Ply SystemEdge DetailRain Gutter Edge DetailInside Corner Outside Corner92-Ply System SpecificationsSPECIFICATION: SA-FR-C-B2Maximum Warranty Duration 12-year NDLFlintlastic SA NailBase sheet, applied using hotasphalt, or Flintlastic SA PlyBase, self-adhered asbase ply. Flintlastic SA Cap FR, self-adhered.For use over non-nailable decks orapproved insulation2.01 Roofing SystemSummary of Materials per 100 Square FeetFlintPrime SA (min. 1/5 gal. per 100ft2) <1 lbs.Flintlastic SA PlyBase (1 ply)* 43 lbs.Flintlastic SA Cap FR (1 ply) 88 lbs.Approximate Total Weight** 132 lbs.*Or 41 lbs plus the asphalt if Flintlastic SA NailBasemopped to primed concrete.**Plus insulation if used.Note: Flintlastic SA Mid Ply (or FlintFlash SA),FlintBond Trowel Grade and FlintBond Caulk Gradeare needed for flashing details and mineral surfacemembrane overlaps. FlintPrime SA is needed forsurfaces that require priming.CantsIn angles of roof deck and vertical surfaces, theroofing contractor shall furnish and install anapproved cant strip with a minimum 3" face.Roof System VentilationRoof system as shown requires ventilation as perNRCA recommendations.Specification with insulation and approvedgypsum cover board meets U.L. Class A forslopes up to 1/2" per foot.SPECIFICATION: SA-FR-N-B2Maximum Warranty Duration 12-year NDLFlintlastic SA NailBase sheet, nailed.Flintlastic SA Cap FR, self-adhered.For use over nailable decks2.01 Roofing SystemSummary of Materials per 100 Square FeetFlintlastic SA NailBase Sheet (1 ply)* 41 lbs.Flintlastic SA Cap FR (1 ply) 88 lbs.Approximate Total Weight* 129 lbs.*Add GlasBase™ Base Sheet if installing U.L. Class Asystem.Note: Flintlastic SA Mid Ply (or FlintFlash SA),FlintBond Trowel Grade and FlintBond Caulk Gradeare needed for flashing details and mineral surfacemembrane overlaps. FlintPrime SA is needed forsurfaces that require priming.CantsIn angles of roof deck and vertical surfaces, theroofing contractor shall furnish and install anapproved cant strip with a minimum 3" face.Use of CertainTeed’s GlasBase under theFlintlastic SA NailBase qualifies the system forU.L. Class A over combustible decks at slopesto 1/2" per foot. GlasBase can be mechanicallyfastened simultaneously with the Flintlastic SANailBase.102-Ply System SpecificationsSPECIFICATION: SA-C-B2Maximum Warranty Duration 12-year NDLFlintlastic SA NailBase sheet, applied using hotasphalt, or Flintlastic SA PlyBase, self-adhered asbase ply. Flintlastic SA Cap, self-adhered.For use over non-nailable decks orapproved insulation(Flintlastic SA Base required over insulation)2.01 Roofing SystemSummary of Materials per 100 Square FeetFlintPrime SA (min. 1/5 gal. per 100ft2) <1 lbs.Flintlastic SA PlyBase (1 ply)* 43 lbs.Flintlastic SA Cap (1 ply) 95 lbs.Approximate Total Weight** 139 lbs.*Or 41 lbs plus the asphalt if Flintlastic SA NailBasemopped to primed concrete.**Plus insulation if used.Note: Flintlastic SA Mid Ply (or FlintFlash SA),FlintBond Trowel Grade and FlintBond Caulk Gradeare needed for flashing details and mineral surfacemembrane overlaps. FlintPrime SA is needed forsurfaces that require priming.CantsIn angles of roof deck and vertical surfaces, theroofing contractor shall furnish and install anapproved cant strip with a minimum 3" face.Roof System VentilationRoof system as shown requires ventilation as perNRCA recommendations.SPECIFICATION: SA-N-B2Maximum Warranty Duration 12-year NDLFlintlastic SA NailBase sheet, nailed.Flintlastic SA Cap, self-adhered.For use over nailable decks2.01 Roofing SystemSummary of Materials per 100 Square FeetFlintlastic SA NailBase Sheet (1 ply) 41 lbs.Flintlastic SA Cap (1 ply) 95 lbs.Approximate Total Weight 136 lbs.Note: Flintlastic SA Mid Ply (or FlintFlash SA),FlintBond Trowel Grade and FlintBond Caulk Gradeare needed for flashing details and mineral surfacemembrane overlaps. FlintPrime SA is needed forsurfaces that require priming.CantsIn angles of roof deck and vertical surfaces, theroofing contractor shall furnish and install anapproved cant strip with a minimum 3" face.11Typical Construction Details – Flintlastic SA 3-Ply SystemVent Pipe Collar DetailParapet Wall Scupper DetailDrain Detail12Shingle Transition Edge DetailTypical Construction Details – Flintlastic SA 3-Ply SystemInside Corner Outside Corner13SPECIFICATION: SA-FR-C-B3Maximum Warranty Duration 15-yearand 20-year NDL Flintlastic SA NailBase sheet, applied using hotasphalt, or Flintlastic SA PlyBase, self-adhered asbase ply.Flintlastic SA Mid Ply, self-adhered.Flintlastic SA Cap FR, self-adhered.For use over non-nailable decks orapproved insulation2.01 Roofing SystemSummary of Materials per 100 Square FeetFlintPrime SA (min.1/5 gal. per 100ft2) <1 lbs.Flintlastic SA PlyBase Sheet (1 ply) 43 lbs.Flintlastic SA Mid Ply (1 ply) 64 lbs.Flintlastic SA Cap FR (1 ply) 88 lbs.Approximate Total Weight* 196 lbs.*Plus insulation as applicable.Note: Flintlastic SA Mid Ply (or FlintFlash SA),FlintBond Trowel Grade and FlintBond Caulk Gradeare needed for flashing details and mineral surfacemembrane overlaps. FlintPrime SA is needed forsurfaces that require priming.CantsIn angles of roof deck and vertical surfaces, theroofing contractor shall furnish and install anapproved cant strip with a minimum 3" face.Specification described (with SA PlyBaseinterply) meets U.L. Class A for slopes up to1/2" per foot over gypsum coverboard.SPECIFICATION: SA-FR-N-B3Maximum Warranty Duration 15-year NDL Flintlastic SA NailBase sheet, nailed.Flintlastic SA Mid Ply, self-adhered.Flintlastic SA Cap FR, self-adhered.For use over nailable decks2.01 Roofing SystemSummary of Materials per 100 Square FeetFlintlastic SA NailBase Sheet (1 ply) 41 lbs.Flintlastic SA Mid Ply (1 ply) 64 lbs.Flintlastic SA Cap FR (1 ply) 88 lbs.Approximate Total Weight 193 lbs.Note: Flintlastic SA Mid Ply (or FlintFlash SA),FlintBond Trowel Grade and FlintBond Caulk Gradeare needed for flashing details and mineral surfacemembrane overlaps. FlintPrime SA is needed forsurfaces that require priming.CantsIn angles of roof deck and vertical surfaces, theroofing contractor shall furnish and install anapproved cant strip with a minimum 3" face.Specification described (with SA PlyBaseinterply) meets U.L. Class A to inclines of 1/2"in 12" over gypsum coverboard.3-Ply System Specifications14SPECIFICATION: SA-C-B3Maximum Warranty Duration 15-yearand 20-year NDL Flintlastic SA NailBase sheet, applied using hotasphalt, or Flintlastic SA PlyBase or Mid Ply,self-adhered as base ply.Flintlastic SA Mid Ply, self-adhered.Flintlastic SA Cap, self-adhered.For use over non-nailable decks orapproved insulation2.01 Roofing SystemSummary of Materials per 100 Square FeetFlintPrime SA (min.1/5 gal. per 100ft2) <1 lbs.Flintlastic SA PlyBase Sheet (1 ply) 43 lbs.Flintlastic SA Mid Ply (1 ply) 64 lbs.Flintlastic SA Cap (1 ply) 95 lbs.Approximate Total Weight* 203 lbs.*Plus insulation as applicable.Note: Flintlastic SA Mid Ply (or FlintFlash SA),FlintBond Trowel Grade and FlintBond Caulk Gradeare needed for flashing details and mineral surfacemembrane overlaps. FlintPrime SA is needed forsurfaces that require priming.CantsIn angles of roof deck and vertical surfaces, theroofing contractor shall furnish and install anapproved cant strip with a minimum 3" face.SPECIFICATION: SA-N-B3Maximum Warranty Duration 15-year NDL and 20-year NDLFlintlastic SA NailBase sheet, nailed.Flintlastic SA Mid Ply, self-adhered.Flintlastic SA Cap, self-adhered.For use over nailable decks2.01 Roofing SystemSummary of Materials per 100 Square FeetFlintlastic SA NailBase Sheet (1 ply) 41 lbs.Flintlastic SA Mid Ply (1 ply) 64 lbs.Flintlastic SA Cap (1 ply) 95 lbs.Approximate Total Weight 200 lbs.Note: Flintlastic SA Mid Ply (or FlintFlash SA),FlintBond Trowel Grade and FlintBond Caulk Gradeare needed for flashing details and mineral surfacemembrane overlaps. FlintPrime SA is needed forsurfaces that require priming.CantsIn angles of roof deck and vertical surfaces, theroofing contractor shall furnish and install anapproved cant strip with a minimum 3" face.3-Ply System Specifications15System Selection GuideFlintlastic SA NailBase Flintlastic SA PlyBase Flintlastic SA Mid Ply Flintlastic SA Cap Flintlastic SA Cap FRRoll Dimensions 64'6" x 39-3/8" 64'6" x 39-3/8" 32'1" x 39-3/8" 32'11" x 39-3/8" 32'11" x 39-3/8"Thickness 1.5 mm 1.5 mm 3.0 mm 4.0 mm 3.2 mmWeight 82 lbs 86 lbs 64 lbs 95 lbs 88 lbs.Coverage 2 Squares 2 Squares 1 Square 1 Square 1 SquareTop Surface Permanent Film Permanent Film Permanent Film Mineral-Variety of Colors MineralBottom Surface Sand Removable Release Film Removable Release Film Removable Release FilmReinforcement Fiber Glass Mat Fiber Glass Mat Polyester/Fiber Glass Polyester/Fiber Glass Heavy Fiber Glass MatScrim Combination Mat Scrim Combination MatTensile (lb/in) 65/40 (MD/CD) 65/40 (MD/CD) 80/60 (MD/CD) 80/60 (MD/CD) 60/55 (MD/CD)Elongation (%) 6/5 (MD/CD) 6/5 (MD/CD) 50/55 (MD/CD) 50/55 (MD/CD) 4/4 (MD/CD)Packaging Palletized, Bands Individual Cartons Individual Cartons Individual Cartons Individual Cartons, 20 Rolls Per Pallet 20 Rolls Per Pallet 20 Rolls Per Pallet 20 Rolls Per Pallet 20 Rolls Per PalletGood – Better – Best. Don't specify less.The chart below is a quick guide to choosing the right roof system for your needs.Please note: the best roofs have adequate drainage and utilize a double-layer of FlintBoard™ roof insulation.GOOD BETTER BESTNailable Decks Non-Nailable Nailable Decks Non-Nailable Nailable Decks Non-NailableAPPNailed base Mopped base Nailed base Mopped base Nailed base, 1 Mopped base, 1and 1 APP Cap and 1 APP Cap and 1 Premium and 1 Premium smooth APP ply smooth APP plyAPP Cap APP Cap and 1 APP Cap and 1 APP CapSBSNailed base Mopped base Nailed base, 1-2 Mopped base, Nailed base, Mopped base,and 1 SBS and 1 SBS BUR fiberglass 1-2 BUR 1 smooth SBS 1 smooth SBSPremium Cap Premium Cap interply sheets, fiberglass Premium ply Premium ply 1 SBS Cap interply sheets, and 1 SBS and 1 SBS 1 SBS Cap Premium Cap Premium CapBURNailed base, 2 Mopped base, Nailed base, Mopped base, Nailed base, Mopped base,BUR interply 2 BUR interply 3 BUR interply 3 BUR interply 3 BUR interply 3 BUR interplysheets, gravel sheets, gravel sheets, gravel sheets, gravel sheets, sheets,surfacing or surfacing or surfacing or surfacing or 1 Premium 1 Premiumfiberglass cap fiberglass cap fiberglass cap fiberglass cap BUR cap BUR capSASA NailBase SA PlyBase SA NailBase 2 SA Plybase SA NailBase SA PlyBaseSA Cap SA Cap SA Plybase SA Cap SA Mid Ply SA Mid PlySA Cap SA Cap SA Cap16UL 2218 Class 4 Impact Resistance – Certain systems are UL classified as to impact resistance as described in the UL Roofing Materials and Systems Directory.Caution: CertainTeed Flintlastic roofing products are intended for use by professional roofing contractors only. It is the responsibility of theinstaller to follow all appropriate and required safety precautions in conjunction with the installation of any CertainTeed roofing product.Meets or exceeds ASTM D6164 (SA Mid Ply and SA Cap), ASTM D6163 (SA Cap FR) and ASTM D4601 (SA NailBase and PlyBase).ICC-ES ESR-1388BUR (Built-Up Roofing) APP Modified BitumenSBS Modified Bitumen Self-Adhering SBS Modified BitumenPrimerFasteners FlintEDGE™ InsulationAdhesive Coating RepairCertainTeed Full SystemsFor more information on CertainTeed Commercial Roofing Products, go to www.certainteed.com or to register, visit ctndl.com. CertainTeed CorporationP.O. Box 860Valley Forge, PA 19482Professional: 800-233-8990Consumer: 800-782-8777© 3/12 CertainTeed Corporation, Printed in U.S.A.Code No. COMM-123ASK ABOUT ALL OF OUR OTHER CERTAINTEED® PRODUCTS AND SYSTEMS:www.certainteed.com http://blog.certainteed.comROOFING • SIDING • TRIM • DECKING • RAILING • FENCE • FOUNDATIONS GYPSUM • CEILINGS • INSULATION • PIPE