Hioki E.E. Corporation
  1. Companies & Suppliers
  2. Hioki E.E. Corporation
  3. Downloads
  4. FT3470-52 - Magnetic Field Hitester ...

FT3470-52 - Magnetic Field Hitester Datasheet

FT3470-51/-52MAGNETIC FIELD HiTESTERComplies with ICNIRP 2010Environmental Measuring InstrumentsCompliance testing of household appliancesCompliance testing of household appliancesProviding robust support for 3-axis magnetic ? ux density measurementProviding robust support for 3-axis magnetic ? ux density measurementMeasurement of environmental magnetic ? eldsMeasurement of environmental magnetic ? eldsMeasurement of magnetic ? elds in the vicinity of electrical power equipmentMeasurement of magnetic ? elds in the vicinity of electrical power equipment2225sThe level output function allows RMS values to be recorded with a recorder or logger, making i t usefu l for applications involving observation of data over extended periods of time.Level output100msX-axisY-axisZ-axisYou can also observe magnet ic field waveforms by connecting the instrument to an oscil loscope or recorder.Waveform output2The memory function is helpful when using the standard-defined measurement method for averaging readings taken at three different heights. The FT3470-50 series can also be used to take measurements at substations, underground lines, and pole-mounted transformers.Using the output funct ion, the FT3470-50 ser ies can be combined with the MEMORY HiCORDER MR8880-20 to observe waveforms, allowing the capture of level and waveform output. Measurement underneath transmission linesLong-term measurement and waveform observationThe instrument can store up to 99 measurement data points in its memory.Memory function Checking data on a computerMeasurement data is saved to memory.Saved data can be checked and deleted on-site. Data can be stored up to memory No. 99.Batch capture: Measurement data recorded using the instrument’s memory function can be imported to a computer with a single operation.Your one-stop solution for magnetic ? eld measurementYour one-stop solution for magnetic ? eld measurementThe FT3470-50 Series complies with the ICNIRP 2010 guidelines as well as other relevant standards for evaluation testing. The FT3470-50 Series complies with the ICNIRP 2010 guidelines as well as other relevant standards for evaluation testing. The guideline value has been changed to 200 µT (for public exposure) at 50/60 Hz.The guideline value has been changed to 200 µT (for public exposure) at 50/60 Hz.The FT3470-50 Series completely supports related measurements.The bundled application software can be used to check measurement data.Compatible OS : Windows XP, Vista, 7Functions : RMS logger, batch export and tester setupStorage format : CSV format2. Magnetic ? eld measurement methods The FT3470-50 Series complies with IEC 62110/IEEE 644 as well as IEC 62233.2. Magnetic ? eld measurement methods The FT3470-50 Series complies with IEC 62110/IEEE 644 as well as IEC 62233.3. Magnetic ? eld measuring instrument requirements The FT3470-50 Series complies with IEC 61786.3. Magnetic ? eld measuring instrument requirements The FT3470-50 Series complies with IEC 61786.1. International guidelines ICNIRP 2010 compliant.1. International guidelines ICNIRP 2010 compliant.The FT3470-50 Series completely supports related measurements.3100cm2 SensorShips with the FT3470-51 and FT3470-52Standard sensor for use with theIEC/EN 62233 standard.f122×295Lmm, 220gThe area of magnetic in? uence that occurs around an object through which a current is passing is termed a magnetic ? eld. Because the values obtained when measuring a magnetic ? eld vary with direction due to the ? eld’s directionality, it is necessary to measure all three axes of the magnetic ? eld.The FT3470-50 Series is capable of accurate measurement because it measures three axes simultaneously and calculates the composite (R) value. It can also measure each axis (X, Y, and Z) separately. What is Three-Axis Measurement?[Image]MagneticFieldXX-axis measurementThe X-, Y-, and Z-axes of Hioki’s 3-axis sensors are labeled, making it easy to identify the direction of magnetic ? elds. Select from two differently sized sensors according to the needs of your application.Two 3-axis sensors3.Procedure for measuring magnetic ? ux density (in microteslas)Position the probe2 Measure the magnetic ? ux density3Magnetic fl ux density mode covers the entire range from 10 Hz to 400 kHz.Set the mode1The FT3470-50 series can also be used to measure exposure levels as defined by IEC/EN 62233 (compliant with the ICNIRP 2010 guidelines).ADVANTAGET(Tesla)SI unit of magnetic fl ux density*1µT=10mGA/mSI unit of magnetic fi eld strengthG(Gauss)Unit of magnetic fl ux densitySimple operation for easy measurement1. User-selectable display units2.Also consider:Record and Analyze Power Supply Problems Simultaneously with a Single UnitThe New World Standard for Power Quality AnalysisPOWER QUALITY ANALYZER PW3198? Assess power quality problems in accordance with international standards (IEC61000-4-30 Class A)?High-precision, gapless recording (V: ± 0.1 % rdg., A and W: ± 0.2 % rdg. ± 0.1 % f.s.)?CATIV 600V - Safe enough for incoming power lines?High-order harmonics and up to 80kHz bandwidth?Wide dynamic input range and rated up to 6000V peak?All standard interfaces included (LAN, USB, SD card)?Synchronize multiple devices with optional GPS BOX3cm2 Sensor Ships with the FT3470-52Enables detailed analysis of magnetic fi eld distribution for measurement targets.?27×165Lmm, 95gThe operation mode switches with every push.The FT3470-50 series can use different units of magnetic ? ux density as required by the applicable standard or regulation. ADVANTAGEADVANTAGEX-axisZ-axisR: Compositex yzY-axisXYZR:CompositeYY-axis measurement ZZ-axis measurement Features4Headquarters : 81 Koizumi, Ueda, Nagano, 386-1192, Japan TEL +81-268-28-0562 FAX +81-268-28-0568 http://www.hioki.co.jp / E-mail: os-com@hioki.co.jpHIOKI USA CORPORATION : TEL +1-609-409-9109 FAX +1-609-409-9108 http://www.hiokiusa.com / E-mail: hioki@hiokiusa.comAll information correct as of Oct. 19, 2012. All specifications are subject to change without notice. FT3470-50E2-2XM Printed in JapanDISTRIBUTED BYHIOKI (Shanghai) Sales & Trading Co., Ltd. : TEL +86-21-63910090 FAX +86-21-63910360 http://www.hioki.cn / E-mail: info@hioki.com.cnHIOKI INDIA PRIVATE LIMITED : TEL +91-731-6548081 FAX +91-731-4020083 E-mail: info@hioki.inHIOKI SINGAPORE PTE. LTD. : TEL +65-6634-7677 FAX +65-6634-7477 E-mail: info@hioki.com.sgHIOKI KOREA CO.,LTD. TEL +82-42-936-1281 FAX +82-42-936-1284 E-mail: info-kr@hioki.co.jpNote: Company names and Product names appearing in this catalog are trademarks or registered trademarks of various companies.Measurement accuracy will be maintained when the tester and sensor are used in an environment where the temperature is 23°C ±5°C and humidity is 80% RH or less with no condensationn Basic specificationsMagnetic flux density 10Hz to 400kHz/ 10Hz to 2kHz/ 2kHz to 400kHzExposure level General Public/ OccupationalIndicated axes X, Y, Z/ R (measured axes: X, Y, Z)Measurement method True RMSRange switching Auto/ manualDisplay update rateSlow function off: 250msec.Slow function on: 2sec.(Slow function: Functionality for applying the 1-sec RMS value integration time required by IEC/EN 62233)Crest factor 3 or lessBut exposure level (occupational) for r1 is 1.45 or less.FunctionSwitching magnetic flux density (T, A/m, G), Slow function, Maximum value hold, Memory function (99 measurements), Auto power off, Buzzer soundInterface USB1.1Storage environment -10 to 50°C, 80% RH or less (no condensation)Operating environment 0 to 40°C, 80% RH or less (no condensation)Period of guaranteed accuracy 1 year Power supply Four LR6 alkaline batteries 1.5V, Rated power supply voltage DC1.5V×4, AC adapter 9445-02Continuous usageApprox. 10 h (with sensor connected, continuous, low load operation)Dimensions 100W×150H×42D mm (3.94"W×5.91"H×1.65"D)Mass 870g (30.7 oz)Applicable standardsSafety EN61010EMC EN61326, EN61000-3-2, EN61000-3-3Standard compliance IEC61786Measurement items RangeMeasurement modePrescribed accuracy rangeMeasurement accuracyXYZr0 10Hz-400kHz10Hz-2kHz2kHz-400kHz0.050 to 2.000 µT ±3.5% rdg.± 0.5% f.s.(50Hz to 100kHz when in 10Hz-400kHz mode)r1 0.50 to 20.00 µTr2 5.0 to 200.0 µTr3 0.050 to 2.000 mTRr0 10Hz-400kHz10Hz-2kHz2kHz-400kHz0.100 to 3.464 µT ±3.5% rdg.± 0.5% f.s.(50Hz to 100kHz when in 10Hz-400kHz mode)r1 1.00 to 34.64 µTr2 10.0 to 346.4 µTr3 0.100 to 3.464 mTFT3470-51/52 (with 100cm2 Sensor)n Exposure level (General Public/ Occupational)Measurement items Range Measurement mode Measurement accuracyX, Y, Zr0 0.50 to 20.00 % ±3.5% rdg. ±0.5% f.s. for smoothed edge 50 Hz to 1 kHz operation±5.0% rdg. ±0.5% f.s. for smoothed edge 1 kHz to 100 kHz operationr1 5.0 to 200.0 %Rr0 1.00 to 34.64 %r1 10.0 to 346.4 %Measurement items RangeMeasurement modePrescribed accuracy rangeMeasurement accuracyXYZr010Hz-400kHz10Hz-2kHz 0.200 to 2.000 µT ±3.5% rdg.± 0.5% f.s.(50Hz to 100kHz when in 10Hz-400kHz mode)2kHz-400kHz 0.050 to 2.000 µTr1 10Hz-400kHz10Hz-2kHz2kHz-400kHz0.50 to 20.00 µTr2 5.0 to 200.0 µTr3 0.050 to 2.000 mTRr010Hz-400kHz10Hz-2kHz 0.400 to 3.464 µT ±3.5% rdg.± 0.5% f.s.(50Hz to 100kHz when in 10Hz-400kHz mode)2kHz-400kHz 0.100 to 3.464 µTr1 10Hz-400kHz10Hz-2kHz2kHz-400kHz1.00 to 34.64 µTr2 10.0 to 346.4 µTr3 0.100 to 3.464 mTFT3470-52 (with 3cm2 Sensor)n Magnetic flux density accuracy specificationsn OutputOutput mode Magnetic flux density (T), Exposure level (%)Output typeMON Waveform output for each axis (X, Y, Z)REC Composite RMS value level output (output via the X-axis)Exposure level output (output via the X-axis)Output accuracyMON ±3.5% rdg.± 10mVREC ±3.5% rdg.± 3mV(±5.0% rdg.±3mV when the exposure level is or exceeds 1kHz)Output rate0.1 mV/display value countAn output rate based on the magnetic flux density unit T is used.Ordering Information SpecificationsFT3470-50 100cm2 Sensor9758 9759 9445-02*Smoothed edge: Exposure level is here defined as the time doman evalution introduced in IEC/ EN 62233 applied to the magnetic flux density indicated in the ICNIRP 2010 Guidelines.)MAGNETIC FIELD HiTESTER FT3470-51Magnetic Field HiTester FT3470-50, 100cm2 Sensor, AC Adapter (9445-02 or 9445-03 (EU)), Instruction manual, CD (PC application software), USB cable, LR6 alkaline battery×4, Carrying CasePacking contents:FT3470-50MAGNETIC FIELD HiTESTER FT3470-52Magnetic Field HiTester FT3470-50, 100cm2 Sensor, 3cm2 Sensor, AC Adapter (9445-02 or 9445-03 (EU)), Extention Cable 9758, Output Cable 9759, Instruction manual, CD (PC application software), USB cable, LR6 alkaline battery×4, Carrying CasePacking contents:n OptionsExtension Cable 9758 (1.5m, for connecting a sensor and the instrument)Output Cable 9759 (1.5m, with three BNC jacks on the output end)AC Adapter 9445-02AC Adapter 9445-03 (EU)100cm2 Sensor3cm2 Sensor
Most popular related searches