SVECOM - P.E. Srl
- Home
- Companies & Suppliers
- SVECOM - P.E. Srl
- Downloads
- Garioni Naval - HRSG & WHRB - Exhaust ...
Garioni Naval - HRSG & WHRB - Exhaust Gas Boilers - Brochure
www.garioninaval.comwww.euroboilers.comENERGY INTELLIGENT ® BOILER PLANT IN WATER-TUBE TECHNIQUEHeat RecoveRyBoileRs-HRsG & WHRB euRoBoileRs GRoupw w w . e u r o b o i l e r s . c o mw w w . g a r i o n i n a v a l . c o m• Building & Hospitals• Manufacturing plants• process industries• petrocHeMical coMplexes• pulp & paper plants• utilities/power producers• iron & steel Mills• tyre & ruBBer factories• cHeMical industries• sugar refineries• fertilizer plantsindustRies seRvedapplicationapplicationindustRies seRvedPower Generation Process SteamProcess HeatCo-Generation•PINCH POINT Approach Temperature•LOAD TURNDOWN & CONTROL•STEAM TEMPERATURE RANGE•SYSTEM PRESSURE DROPS Operating Modes Firing Temperatures Staggered or inline Tubes Parasitic Loads Availability / Reliability Casing Design Material Selection (process and gas sides)w w w . g a r i o n i n a v a l . c o mdesiGn pointsdesiGn pointsACCORDING TO HEAT INPUT • Unifired • Supplementary Fired • Fully Fired • Fresh air firedACCORDING TO CIRCULATION • Natural circulation • Forced circulation • Assisted circulation ACCORDING TO NUMBER OF PRESSURE LEVELS • Single Pressure / Low or High • Multiple Pressure / Low or High ACCORDING TO SOURCE AND HYGIENE • Biomass, MSW, Solid Fuels, Coals, Prime Mover • Clean or DirtyACCORDING TO PROJECT CONSTRAINTS • Economy, Emissions, Timelines, Locationsw w w . e u r o b o i l e r s . c o mselection cRiteRiaselection cRiteRiaw w w . g a r i o n i n a v a l . c o mSimplex-2 Pass HorizSimplex-2 Pass VertDuplex-1 Pass HorizSimplex-1 Pass HorizSimplex-1Pass-Elev DrumSimplex-Special-1Pass-WaterCoolBiDrum-Cross Drum (max 950C)BiDrum-Vertical (max 950C)Bi-Drum-Membrane (max 1482C)Field Erected DesignsElevated Drum DesignCoil Type DesignOnce Thru HRSGWHRB-STHWHRB-STVWHRB-DSHWHRB-SSH-(DF)WHRB-SSE-(DF)WHRB-SMH-(DF)HRSG-CDSHRSG-CDVHRSG-PFMHRSG-FEHEGB–EDDEGB-CTCOTSG10.0 Tons/Hr.10.0 Tons/Hr.15.0 Tons/Hr.30.0 Tons/Hr.30.0 Tons/Hr.30.0 Tons/Hr125 Tons/Hr.125 Tons/Hr.125 Tons/Hr.As Reqd.30 Tons/Hr.5 Tons/Hr.As Reqd25 Bar25 Bar25 Bar25 Bar25 Bar25 Bar80 Bar80 Bar80 BarAs Req.50 Bar50 BarAs Req.SATSATSAT/SHSAT/SHSAT/SHSH/SH550C550C550CAs Req.SH400CSATAs Req.Engines/GT/Process GasEngines/GT/Process GasEngines/GT/Process GasGT/Process Gas(+Gas, Fuel Oil)Engines/GT/Process GasGT/Process Gas(+Gas, Fuel Oil)Engines/GT/Process GasEngines/GT/Process GasEngines/GT/Process GasGTsEngines/GT/Process GasEngines/GT/Process GasGTProduct Series Capacity Pressure Temp Fuels Up to: Up to: Up to:RanGeRanGesupplementaRy fiRinG BuRneRcomBustion system (Integrated into PLC Management Systems) (Interlocked with PLC Management System) (FireEye/Honeywell) Fuel Skids to EN-12952/NFPA/IRI/FM (Rack &/or Windbox Mount) (Fully-metered &/or single-point designs) (Compact Packaged) • In Duct Grid Design • Register Design (In Duct)• Standards: EN-12952/NFPA/IRI/FMPitch• Packaged Fuel Skids• Scope Includes: Combustion Air Blower With Seal Air Damper for Fresh Air Firing. Silencer is Standard. (Standard Inverter Rated Motor/Optional VSD) Burner Management / Combustion Control SystemsupplementaRy fiRinG BuRneR comBustion systemw w w . e u r o b o i l e r s . c o m• (S) For Heavy Oils (Re-Circulation Control)• (O) BMS Integrated into PLC (Economic Module)• (O) Intermittent Blow-Down Control• (O) Redundant Electro-Mechanical Reserve System (Controllers-Fuji/Yokogawa/Honeywell/Eurotherm)• (O) De-Superheating Control (Attemperator or Diverging CV), Pressure Control Stations, Combi Stations• (O) Automatic Soot Blowing Control (Steam or Sonic)•(S) Double Door Enclosure w/ Indipendent MCC & PLC Section- (IP/NEMA) ; (IP 54/55 or IP 40 or Ex-Proof) a (O) Purge Control Unit (Ex-Proof)• (S) Panel Air Conditioning Unit• (S) UPS for PLC Control Section• (S) BMS Interlocked with PLC• (S) Touch Screen Control Panel With PLC (Optional Fail Safe PLC)• (S) DCS/SCADA Communication Interface (Modbus/Ethernet/Profibus)• (S) 3-Element Control System• (S) Flow Metering with trending for Main Fuel, Steam, Feed Water• (S) De-Salting Drum (Surface) Blow Down Control• (S) Oxygen Trim (O2) Control (Fired Boilers Only)• (S) Level Switches Based on Conductivity Probes (in addition to LT/Cap)w w w . g a r i o n i n a v a l . c o mcontRol systemcontRol systemElectrical Devices GE / Terasaki or Green Power /Telemecanique or MGPLC System RENU or ICP-DAS (High Ambients) Siemens or Allen Bradley or MitsubishiFixtures & Fittings EU/USA/JapanOxygen Analyzers Ametek (Land Instruments)/Fuji/Client SpecificValves Kitazawa or Velan / Mival / Valvole Hoffman (LP) / DHV or Equiv. (Isolation & Drains)Feed Pumps SIHI or KSB (HP) / Grundfoss or Nocchi (LP)Dosing Systems LMI (LP) / Doseuro (HP)Safety Valves Tyco (Kunkle) / LeserSampling Stations FM (Catch’n’Grab Stations are Standard) Fully Automated Water Analysis Stations on Request)Control Valves Samson or Arca or Koso / Fisher or MasonlienanTransmitters Fuji or Autrol/Ivensys or Honewell/Yokogawa or RosemountTemp. Sensors/TT Comeco or FujiVortex Meters Krohne or RheonikGauges Nuvo Fima / AshcroftSwitches Danfoss or Sauter or SOR / Mercoid / AshcroftVariable Speed Drives ABB or Yasakawa or Fuji/Danfoss or Schneider/LS SystemsLevel Control Switches Gestra or Mobrey / VYC or RTK / Clark RelianceDe-Salting Control Gestra or Spirax / VYC or RTKLevel Indicators Klinger / Bont or Diesse (LP)w w w . e u r o b o i l e r s . c o mWoRld class equipmentsWoRld class equipments• ELECTRICALS, INSTRUMENTATION AND CONTROLS• NEMA/IP/Ex-PROOF• CONTINUOUS EMISSIONS MONITORING SYSTEMS (CEMS)• LADDERS & PLATFORMS• AIR & FLUE HEATERS• FUEL OIL HEATERS AND PUMPING SKIDS• BLOWDOWN SYSTEMS• SCR, SNCR, & CO Catalytic System (NOX/SOX CONTROL)• ERECTION AND COMMISSIONING• DIVERTER, DAMPERS, GUILLOTINES, EXPANSION JOINTS• FLUE GAS DUCTING Internal Lined (Insulated) in Carbon Steel With (O) SS Liners External Insulated/Uninsulated in Carbon Steel, Corten or Stainless• DEAERATORS Pressurized (Tray or Spray) Atmospheric (Spray)• FEED WATER PUMPS Turbine Driven Motor Driven• DOSING SYSTEMS• STACKS Main and/or By-Pass External Insulated/Uninsulated/Lined in Carbon Steel, Corten or Stainlessw w w . g a r i o n i n a v a l . c o mplant Room equipmentsplant Room equipmentsin tHe siZinG of tHe economiZeRappRoacH point is usedappRoacH point is used in tHe siZinG of tHe economiZeR• The approach is the difference between the economizer water outlet temperature and the Saturation temperature of the steam. A good approach point is between 15°F - 30°F.• This temperature will guarantee that no steaming will occur in the economizer section.• It is not always possible to achieve an approach point in this zone.• If the saturation temperature is too high, achieving an approach temperature in this zone will lead to a stack outlet temperature well below the dew point, resulting in use of special steels to avoid corrosion.w w w . e u r o b o i l e r s . c o mw w w . g a r i o n i n a v a l . c o m• The pinch point is the difference between the saturation temperature and the EVAP exit temperature• It is desirable to make the pinch point as small as possible without making the cost of the EVAP astronomicaltRansfeR suRface aReapincH is ussed in siZinG Heatof tHe evappincH is ussed in siZinG Heat tRansfeR suRface aRea of tHe evappRocess desiGn consideRationpRocess desiGn consideRationSYSTEM DRAFT LOSSHigher the permissible draft loss. Lower is the capital cost and GT output.Restriction on firing temperature due to construction. All operating modes to satisfy this limit.FIRING TEMPERATURE LIMITATIONPINCH POINTLower Pinch means higher heat recovery and higher capital cost.Lower approach means higher heat recovery and higher capital cost. Lower approach means higher steaming potential under upset/partial load conditions.APPROACH TEMPERATUREDifficult for unfired units as heat source is uncontrolled. Some what better for supplementary fired units as heat imput is partially controllable.APPROACH TEMPERATURE / APPROACH TEMPERATUREVery narrow for unfired units. Comparatively wider for fired units as EXH.Gas reheat temperature has a considerable impact on steam temp.STEAM TEMPERATURE CONTROL RANGEw w w . e u r o b o i l e r s . c o mHigher operating modes to suit operation. Design needs checking for worst conditions.NUMEROUS OPERATING MODESw w w . g a r i o n i n a v a l . c o mw w w . e u r o b o i l e r s . c o mw w w . g a r i o n i n a v a l . c o mw w w . e u r o b o i l e r s . c o mGARIONI NAVAL S.p.A.V.le dei Caduti 3 - 25030 Castelmella (Bs) - Italyphone +39 030 2681541 - fax +39 030 2680910garioninaval@garioninaval.comSTEAM GENERATORSSTEAM BOILERSTHERMAL OIL HEATERSHOT WATER BOILERSPRESSURIZED WATER BOILERSELECTRIC STEAM GENERATORSMARINE APPLICATIONSRECOVERY BOILERSECONOMIZERSWATER TREATMENTACCESSORIES
Most popular related searches
