
Chongqing Blue Jay Technology Co.,Ltd
General Electric Data Monitor Unit BJ-194E-2S4(S)
Chongqing Blue Jay Electronic Co., Ltd Product Introduction Tel: +0086-023-67636974 Email:sales@cqbluejay.com Fax:+0086-023-67636974 Add: Redstone Road 2# 17-3,Jiangbei District , 400020, Chongqing, P.R.China BJ-194E-2S4(S) Electric Data Monitor Unit 1. 3 lines LED display 2. Select bottom 3. Control bottom 4. Enter bottom 5. LED display show parameter Function & Feature ·Class 0.2 or 0.5 power and energy ·Current measuring .../5 or .../1 A ·Option RS-232 Modbus/RTU Communications ·Expandable input / output modules (up to 3 modules) ·ITF Technology: galvanic insulation protection inputs outputs ·Universal series power supply Applications ·Metering of distribution feeders, transformers, generators, capacitor banks and motors. ·Medium and low voltage systems. ·Commercial, industrial, utility. BJ194E-2S4(S), simplify type of the E series power meter, Removed the alarm and pulse interface Measure: Three-phase voltage (phase voltage, line voltage), frequency, current, active power, reactive power, apparent power, power factor, active power, reactive power. These parameters can be centralized on a PC or PLC through an RS 235 link using MODBUS protocol. Also can choose ASCII code direct output, easy for secondary development. Can connect CT and free to set CT & PT ratio with its four direct access keys and LED displays. Chongqing Blue Jay Electronic Co., Ltd Product Introduction Tel: +0086-023-67636974 Email:sales@cqbluejay.com Fax:+0086-023-67636974 Add: Redstone Road 2# 17-3,Jiangbei District , 400020, Chongqing, P.R.China Technical characteristics Current measurement on inputs (TRMS) Power measurement CT primary 10 000 A Accuracy 0.50% CT secondary 1 and 5 A 1 and 5 A Power factor measurement Measurement range 0 ... 11 kA Accuracy 0.50% Input consumption <0 .1 VA Auxiliary power supply Measurement updating period 1 s AC voltage DC/AC 85~265 ± 30 % Accuracy 0.20% Frequency 50 / 60 Hz Impulse withstand voltage 4 kV Consumption < 10 VA Voltage measurement (TRMS) Communication Direct measurement between phases 18 ... 400 VAC Link RS232/RS485 PT primary 500 000 VAC Terminal DB9 or pin connect PT secondary 100VAC/400VAC Type 2 ... 3 wires half duplex Frequency 50 / 60 Hz Protocol Modbus ASCII mode Input consumption <0 .1 VA ASCII mode direct output Frequency measurement MODBUS speed 4800/9600bauds Measurement range 45 ... 65 Hz Operating conditions Accuracy 0.10% Operating temperature - 10 ... + 55 °C Energy accuracy Storage temperature - 20 ... + 85 °C Active (according to IEC 62053-22) Class 0 .5 S Relative humidity 95% Reactive (according to IEC 62053-23) Class 2 Dimensions Type Panel mounting Dimensions H x W x D 120 x 120 x 128 mm Case protection rating IP 40 Display type LED Terminal block type fixed Weight 450 g Ordering Information: BLUE JAY ELECTRONIC accept customized products, please contact our sales team before order
Most popular related searches
Stay in the loop!
Select your areas of interest to receive industry updates.