1. INSTALLATION• Remove the cover and snap battery into battery snap. • Insert the battery in the blue plastic holder.2. OPERATION• In the default mode, the button will silence the audio buzzer while the LED keeps blinking until the alarm state is corrected. If not in an alarm state, the button tests the circuit.• There is a two second delay to damp any sloshing of the liquid.• A low battery voltage is signaled by a intermittent beeping for 5 seconds every 30 seconds, (to conserve power). The LED will blink continuously.3. DIFFERENT MODES• Jumper B should always be on. Jumper A always off. • Jumpers C and D work in combination to produce these modes:• A buzzer “snooze alarm” is done by connecting the input ot LS2 terminal blocks. Buzzer repeats every 30 minutes until level is corrected.4. BATTERY LIFEThe low power circuit allows the battery to last for 10 years. Any alarms will deplete the battery at a rate of 25mA. Therefore the Ultralife battery included (capacity of 1250mA-hr) will produce a continuous alarm for about 50 hours.March 29, 2013ALARM BOX (AB-1)Engineering 205 Seneca Parkway, Rochester, NY 585-301-0970 www.drumalarm.comC D BEHAVIOR USEOFF OFF Pushing button silences alarm, LED continues to blink until level corrected.DefaultON OFF Buzzer output sounds for 4 seconds. (one time)WirelessOFF ON Two inputs, two separate outputs. SpecialON ON Pushing the button shuts of the buzzer and LED. Automatically resets when level is corrected.ShutoffBCDA