MWA Technology
  1. Companies & Suppliers
  2. MWA Technology
  3. Downloads
  4. Kamstrup Multical 402 Heat Meters ...

Kamstrup Multical 402 Heat Meters Brochure

Industrivej 28, Stilling · 8660 Skanderborg · Denmark · Tel.: +45 89 93 10 00 · Fax: +45 89 93 10 01 · info@kamstrup.com · www.kamstrup.comMULTICAL® 402Application MULTICAL® 402 is the compact ultrasonic meter which registers the exact consumption due to its supreme measuring accuracy. The meter is maintenance-free and has a long lifetime which guarantees minimum yearly operating costs. MULTICAL® 402 is used for heat, cooling and combined heat /cool-ing measurement in all water-based systems with temperatures from 2 to 160°C. The meter has been developed for measurement of energy consump-tion in family and multiple occupancy housing, housing associations, blocks of flats and small industry. FunctionalityMULTICAL® 402 consists of calcula-tor, flow sensor and two temperature sensors and is simple to install, read and verify. Our flow sensor range for MULTICAL® 402 comprises of the sizes 0.6 – 15 m³/h, and the supply options are 230 or 24 VAC mains module, 2xAA-cell battery, or D-cell battery with up to 16 years’ lifetime. MULTICAL® 402 is fitted with a connector for the supply and thus, it is easy to change battery or mains supply.By means of the calculator’s two front keys it is easy to adjust date and time or reset operating hour counter and info-event counter. Furthermore, the keys can be used to display log data, incl. yearly or monthly logger.MULTICAL® 402 receives pulses from up to two connected hot or cold water meters and carries out remote accumulation of energy and volume via pulse outputs. If you change from pulse input to pulse output, the meter is automatically configured for pulse inputs and pulse outputs respectively – without manual reconfiguration. Wireless readingThe meter is remotely read via Wire-less M-Bus or radio module. Con-sumption data is read, saved and transferred by means of the USB Meter Reader. Furthermore, radio can be read by means of a hand-held terminal or form part of a Kamstrup radio network. The transferred data is used for individual billing, consumption analysis and/or energy optimisation.Compact meter for heat and cooling with maximum functionalityD A T A S H E E T ? Up to 16 years’ battery lifetime ? Set/reset function ? Pulse outputs for energy and volume ? Pulse inputs for up to two water meters ? Wireless reading via Wireless M-Bus or radio0200M10MID-2004/22/EC2 5810725_E1_GB_11.2010MULTICAL® 402D A T A S H E E TContent Calculator functions 3 Pulse outputs and pulse inputs of the modules 7 Cabinet design 8 Approved meter data 9 Electrical data 10 Mechanical data 12 Materials 13 Accuracy 14 Dimentional sketches 16 Pressure loss 19 Accessories 20Energy calculationMULTICAL® 402 calculates energy based on the formula in EN 1434-1:2004, in which the international temperature scale from 1990 (ITS-90) and the pressure definition of 16 bar is used.The energy calculation can in a simplified way be expressed as: Energy = V x ?T x k. V is the supplied water volume?T is the temperature difference measured k is the thermal coefficient of water The calculator always calculates energy in [Wh], and then it is converted into the selected measur-ing unit.Application typesMULTICAL® 402 operates with four different energy formulas, E1...E9, that are all calculated in parallel in connection with each integration no matter how the meter is configured.The four energy types are calculated as follows:E1=V1(T1-T2)k Heat energy (V1 in flow or return)E3=V1(T2-T1)k Cooling energy (V1 in flow or return)E8=m³xT1 (Flow pipe)E9=m³xT2 (Return pipe)This renders MULTICAL® 402 capable of calculating the heat and cooling energy of most applica-tions, both closed and open systems.All energy types are data logged and can be displayed in-dependent of configuration.Flow measurementMULTICAL® 402 calculates current water flow every 12 seconds or every 4 seconds depending on configuration.Power measurementMULTICAL® 402 calculates current power on the basis of current water flow and the temperature difference measured in connection with the latest integration.Current power is updated in the display every 24 seconds or every 4 seconds depending on configuration. Calculator functions35810725_E1_GB_11.2010MULTICAL® 402D A T A S H E E TE [Wh] = V x ?T x k x 1000E [kWh] = E [Wh] / 1,000E [MWh] = E [Wh] / 1,000,000E [GJ] = E [Wh] / 277,780E [Gcal] = E [Wh] / 1,163,100The upper push button is used to switch between the primary readings. The consumers typically use the first primary readings in connection with self-reading for bill-ing purposes.The lower push button is used to show secondary informa-tion on the selected primary reading.Min. and max. flow and powerMULTICAL® 402 registers minimum and maximum flow and power on a monthly as well as on a yearly basis. The registrations which can be read via data communication include max. and min. flow and power values, all with date indication.All max. and min. values are calculated as largest and smallest aver-age respectively of a number of current flow or power measurements. The average period used for all calculations is selected in the interval 1…1440 min.Temperature measurementMULTICAL® 402 is available in different versions for either Pt100 or Pt500 sensors in a 2-wire version.The measuring circuit includes a high resolution analog/ digital converter with a temperature range of 0,00°C…165,00°C.In addition to current temperatures for the energy calculation average temperatures on a yearly and monthly basis can also be displayed.Display functionsMULTICAL® 402 is equipped with a clear LC display including 8 digits, units of measurement and infor-mation panel. In connection with energy and volume readings 7 digits and the units of measurement to match are used, whereas 8 digits are used when e.g. meter number is read.As a starting point the display shows accumulated energy. When the push buttons are activated the display reacts immediately by calling other readings. The display automatically returns to accumulated energy reading 4 minutes after the latest activation of the push buttons.Calculator functions4 5810725_E1_GB_11.2010MULTICAL® 402D A T A S H E E TInfo code Description Response time0 No irrigularities -1 Supply voltage has been cut off -4 T2 sensor outside range, short-circuited or cut off < 30 sec.8 T1 sensor outside range, short-circuited or cut off < 30 sec.4096 District heating leak < 30 sec.16384 District heating burst < 30 sec. Calculator functionsSet/reset functionThe set/reset function of MULTICAL® 402 makes it possible to change a number of parameters by means of the two buttons on the meter’s front. The following parameters can be changed:• Date• Hour• Input A (preset of register)• Input B (preset of register)• Meter no. of Input A• Meter no. of Input B• Primary M-Bus address• Operating hour counter (reset)• Info-event counter (reset) As the installation seal is broken, the change can only be made by the energy supplier.Info codesMULTICAL® 402 constantly monitors a number of important functions, e.g. power supply, temperature sensors and leakage alarms. Should a serious error occur in the measuring system or in the installation, a flashing “INFO” will appear in the display whilst the error exists. The “INFO” panel will automatically disappear when the error has been corrected.An Info Event Logger indicates how many times the info code has been changed.The info logger stores the latest 50 changes, of which 36 can be displayed.55810725_E1_GB_11.2010MULTICAL® 402D A T A S H E E TVoltage supplyMULTICAL® 402 is available with 2 x AA battery supply (up to a lifetime of 6 years), D-cell battery (up to a lifetime of 16 years incl. Wireless M-Bus), 230 VAC mains module or 24 VAC mains module. The sup-ply modules are exchangeable without breaking the verification seal.Plug-in modulesPlug-in modules can be added to MULTICAL® 402 such as• Data• M-Bus• Wireless M-Bus• RadioIn this way the meter can adapt to various applications and data reading methods.Programming and verificationMETERTOOL for MULTICAL® 402 is a Windows® -based software which includes all facilities for calcula-tor programming. If the software is used together with VERIFICATION EQUIPMENT for MULTICAL® 402, the calculator can be tested and verified.Data logging interval Data logging depth Logged valueYearly logger 15 years Counter (as seen on the display)Monthly logger 36 months Counter (as seen on the display)Daily logger 460 days Consumption (increase)/dayInfo logger50 events (36 events can be shown in the display)Info code and dateData loggersMULTICAL® 402 contains a permanent memory (EEPROM), where the results of a number of various data loggers are stored. The meter contains the following data loggers:Calculator functions6 5810725_E1_GB_11.2010MULTICAL® 402D A T A S H E E TPulse outputs CE and CVMULTICAL® 402 has pulse outputs for energy and volume pulses respectively. CE on terminals 16-17 releases one pulse per least sig-nificant digit of the energy count in the display and CV on terminals 18-19 releases one pulse per least significant digit of the volume count in the display.If a higher resolution of pulse outputs is required, a CCC code with high resolution must be selected.Pulse inputs VA and VBMULTICAL® 402 has two extra pulse inputs, VA and VB, to collect and accumulate pulses remotely, e.g from cold-water meters and electric-ity meters. The pulse inputs are physically placed on the plug-in modules.The pulse inputs VA and VB function independently of the other inputs/outputs.Pulse outputs and pulse inputs of the modulesTariff functionsMULTICAL® 402 has 2 extra registers TA2 and TA3 to accumulate energy parallelly to the main register based on a programmed tariff condition. No matter which tariff type you select the tariff registers will be displayed as TA2 and TA3.The main register is always accumulated, irrespective of the selected tariff function, as it is considered the legal billing register. Tariff conditions TL2 and TL3 are monitored before each integration. If the tariff conditions are fulfilled, the consumed heat energy is ac-cumulated in either TA2 or TA3, as well as the main register.Calculator functions75810725_E1_GB_11.2010MULTICAL® 402D A T A S H E E TCabinet designPower supply/batteryTerminals for temperature sen-sorsButtons for changing displayUnder the cover the calcula-tor’s electronics are sealed by a verification label (secu-rity seal)Plug-in modulePlug for power supply/battery8 5810725_E1_GB_11.2010MULTICAL® 402D A T A S H E E TEU directives – Measuring Instrument Directive – Low Voltage Directive – Electromagnetic Compatibity Directive– Pressurised Equipment DirectiveStandard prEN 1434:2009Heat meter – Approval DK-0200-MI004-013– Temperature range ?: 2°C...160°C– Differential range ?T: 3K...150KCooling meter – Temperature range ?: 2°C...50°C– Differential range ?T: 3K...30KAccuracy EC ±(0,5 + ?Tmin/?T)%Temperature sensors – Type 402-V Pt100 – EN 60 751, 2-wire connection– Type 402-W/T Pt500 – EN 60 751, 2-wire connectionEN 1434 designation Environmental class AMID designation – Mechanical environment class M1– Electromagnetic environment class E1Non condensing, closed location (indoor installation), 5…55°CApproved meter dataType number Nom. flow qp [m³/h]Max. flow qs [m³/h]Min. flow qi [l/h]Min. cut off [l/h]Pressure loss ?p @ qp [bar]Connection meterLength [mm]402xxxxxx1xxx 0.6 1.2 6 3 0.04 G¾B 110402xxxxxx3xxx 0.6 1.2 6 3 0.04 G1B 190402xxxxxx4xxx 1.5 3.0 15 3 0.25 G¾B 110402xxxxxx5xxx 1.5 3.0 15 3 0.25 G¾B 165402xxxxxx7xxx 1.5 3.0 15 3 0.25 G1B 130402xxxxxx9xxx 1.5 3.0 15 3 0.25 G1B 190402xxxxxxAxxx 2.5 5.0 25 5 0.05 G1B 130402xxxxxxBxxx 2.5 5.0 25 5 0.05 G1B 190402xxxxxxDxxx 3.5 7.0 35 7 0.07 G5/4B 260402xxxxxxFxxx 6.0 12 60 12 0.19 G5/4B 260402xxxxxxGxxx 6.0 12 60 12 0.19 DN25 260402xxxxxxHxxx 10 20 100 20 0.06 G2B 300402xxxxxxJxxx 10 20 100 20 0.06 DN40 300402xxxxxxKxxx 15 30 150 30 0.14 DN50 270 The stated minimum temperatures apply to the type approval only. The meter has no cutoff for low tem-perature and thus measures as low temperatures as 0.01°C and 0.01 K.95810725_E1_GB_11.2010MULTICAL® 402D A T A S H E E TReplacement interval3.65 VDC, D-celle lithium3.65 VDC, 2xAA cell lithiumMounted on wall16 years @ tBAT < 30°C 6 years @ tBAT < 30°CMounted on the flow sensor12 years @ tBAT < 40°C 5 years @ tBAT < 40°C10 5810725_E1_GB_11.2010MULTICAL® 402D A T A S H E E TCalculator dataTypical accuracy – Calculator EC ±(0.15 + 2/?T)% – Sensor set ET ±(0.4 + 4/?T)%Display LCD – 7 (8) digits with a digit heigth of 7.6 mmResolution 9999.999 – 99999.99 – 999999.9 – 9999999 Energy units MWh – kWh – GJ – Gcal Data logger (Eeprom) 460 days, 36 months, 15 years, 50 info codesClock/calendar Clock, calendar, leap-year compensation, target dateData communication KMP protocol with CRC16 used for optical communication and for base modulesPower in temperature sensors < 10 µW RMS sensorsSupply voltage 3.6 VDC ± 0.1 VDCBattery The replacement interval is reduced by using data modules, at frequent data communication and at high ambient temperature.Mains supply 230 VAC +15/-30%, 50/60 Hz 24 VAC ±50%, 50/60 HzInsulation voltage 4 kVPower supply < 1 WBack-up supply Integral super-cap eliminates operational stop-down due to short-term power cuts.EMC data Meets EN 1434 class A (MID class E1)Electrical data115810725_E1_GB_11.2010MULTICAL® 402D A T A S H E E TElectrical dataTemperature measurementT1 Flow temperatureT2 Return temperature?T(T1-T2) Heat metering?T(T2-T1) Cooling metering402-V 2-W Pt100Measuring range0.00…165.00°C 0.00…165.00°C 0.01…165.00K 0.01…165.00K402-W/T 2-W Pt500Measuring range0.00…165.00°C 0.00…165.00°C 0.01…165.00K 0.01…165.00KPulse inputs VA and VB VA: 65-66 and VB: 67-68 via moduleWater meter connection FF(VA) and GG(VB) = 01…40Pulse input 680 k? pull-up to 3.6 VPulse ON < 0.4 V for > 30 msec.Pulse OFF > 2.5 V for > 1.1 sec.Pulse frequency < 0.5 Hz Electrical isolation NoMax. cable length 25 m Requirements to external contact Leakage current at function open < 1 µA Pulse outputs CE and CV Energy (16-17) Volume (18-19) via moduleThe pulse outputs can be configured for heat or cooling energyType Open collector (OB)Pulse length Programmable 32 msec. or 100 msec. External voltage 5…30 VDCCurrent 1…10 mAResidual voltage UCE ˜ 1 V at 10 mAElectrical isolation 2 kVMax. cable length 25 m 12 5810725_E1_GB_11.2010MULTICAL® 402D A T A S H E E TEnvironment class Meets EN 1434 class A (MID class E1)Ambient temperature 5…55°C, non condensing, closed location (indoor installation)Protection class – Calculator IP54– Flow sensor IP65Media temperature – Heat meters 402-V/W: 15…130°C – Cooling meters 402-T: 2…50°C – Heat/Cooling meters 402-T: 2…130°C – Media in flow sensor WaterStorage temperature -20…60°C (drained flow meter)Pressure step (with thread) PN16Pressure step (with flanges) PN25Weight From 1.8 to 12 kg depending on the size of the flowpart Flow sensor cable 1.5 m (the cable cannot be removed)Connection cables ø3.5…6 mmSupply cable ø5…10 mmMechanical dataAt medium temperatures over 90°C in the flow sensor, we recommend using flange meters and mounting the calculator on the wall.135810725_E1_GB_11.2010MULTICAL® 402D A T A S H E E TWetted parts Housing, gland Enkotal (alpha brass)Housing, flange Stainless steel, W.no. 1.408 or RG5 (red brass)Transducers AISI 316Gaskets EPDMMeasuring pipe PES 30% GFReflectors AISI 304Flow sensor housingTop/wall brackets PC + 20% glassCalculator casingTop cover PCBase unit ABS with TPE gaskets (thermoplastic elastomer)Internal cover ABSFlow sensor cable Silicone cable with internal teflon insulationMaterials14 5810725_E1_GB_11.2010MULTICAL® 402D A T A S H E E TAccuracySub-units of the heat meter MPE according to EN 1434-1 MULTICAL® 402, typical accuracyFlow sensor Ef = ±(2 + 0.02 qp/q) % Ef = ±(1 + 0.01 qp/q) %Calculator Ec = ±(0.5 +?Tmin/?T) % Ec = ±(0.15 + 2/?T) %Sensor set Et = ±(0.5 + 3?Tmin/?T) % Et = ±(0.4 + 4/?T) % -6,0-4,0-2,00,02,04,06,00,01 0,10 1,00 10,00q [m³/h]Tol [%]Ec+Et+Ef (EN)Ec+Et+Ef (Typ)MULTICAL ® 402 qp 1,5 m³/h @ ?T 30KMULTICAL® 402 qp 1.5 m³/h @ ?T 30KOrder specifications155810725_E1_GB_11.2010MULTICAL® 402D A T A S H E E TMULTICAL® 402 Type 402 ? ? ? ? ? ? ? ? ? ?Sensor connection Pt100 VPt500 WPt500 (with condensation protected flow sensor for cooling) TModules No module 00Data + 2 pulse inputs (VA, VB) 10Data + 2 pulse outputs (CE, CV) 11M-Bus + 2 pulse inputs (VA, VB) 20M-Bus + 2 pulse outputs (CE, CV) 21Wireless M-Bus, EU, 868 MHz, Mode C1 30Radio, EU, 434 MHz, int. ant., NET0 40Radio, EU, 434 MHz, int. ant., NET1 41Radio, EU, 434 MHz, int.+ext. ant., NET0 + 2 pulse inputs (VA, VB) 42Radio, EU, 434 MHz, int.+ext. ant., NET0 + 2 pulse outputs (CE, CV) 43Radio, EU, 434 MHz, int.+ext. ant., NET1 + 2 pulse inputs (VA, VB) 44Radio, EU, 434 MHz, int.+ext. ant., NET1 + 2 pulse outputs (CE, CV) 45Radio, SE, 444 MHz, int. ant., NET0 + 2 pulse inputs (VA, VB) 50Radio, SE, 444 MHz, int. ant., NET1 + 2 pulse inputs (VA, VB) 52Radio, SE, 444 MHz, ext. ant., NET0 + 2 pulse inputs (VA, VB) 54Radio, SE, 444 MHz, ext. ant., NET1 + 2 pulse inputs (VA, VB) 56Supply No module 0Battery, 2 x AA 1Battery, D-cell 2230 VAC supply module 724 VAC supply module 8Pt500 sensor setNo sensor set 00Pocket sensor set with 1.5 m cable 0APocket sensor set with 3.0 m cable 0BShort direct sensor set with 1.5 m cable 0FShort direct sensor set with 3.0 m cable 0GFlow sensorqp [m³/h] Connection Length [mm] 0.6 G¾B (R½) 110 10.6 G1B (R¾) 190 31.5 G¾B (R½) 110 41.5 G¾B (R½) 165 51.5 G1B (R¾) 130 71.5 G1B (R¾) 190 92.5 G1B (R¾) 130 A2.5 G1B (R¾) 190 B3.5 G5/4B (R1) 260 D6.0 G5/4B (R1) 260 F6.0 DN25 260 G10 G2B (R1½) 300 H10 DN40 300 J15 DN50 270 KMeter type Heat meter (MID: module B+D) 2Heat meter (MID: module B+D. Only MULTICAL® 402 T) 3Heat meter 4Cooling meter (only MULTICAL® 402 T) 5Heat/cooling meter (only MULTICAL® 402 T) 6Country code (language on lable etc.) XXDimentional sketchesMechanical measurements of the electronics unitFlow sensor with G¾ and G1 thread connectionThread L M H2 A B1 B2 H1 Approx. weight [kg]G¾ 110 L/2 89 10.5 50.5 35 48.5 1.4G1 (qp 1.5) 130 L/2 89 20.5 50.5 35 48.5 1.5G1 (qp 2.5) 130 L/2 89 20.5 50.5 35 48.5 1.4G¾ 165 L/2 89 20.5 50.5 35 48.5 1.8G1 (qp 1.5) 190 L/2 89 20.5 50.5 35 48.5 2.0G1 (qp 2.5) 190 L/2 89 20.5 50.5 35 48.5 1.9Weight includes a 3 m Short direct sensor set, but is excluding packing.16 5810725_E1_GB_11.2010MULTICAL® 402D A T A S H E E TDimentional sketchesFlow sensor with G5/4 and G2 thread connectionThread L M H2 A B1 B2 H1 Approx. weight [kg]G5/4 260 L/2 88.7 17 50.5 22 48.5 2.9G2 300 L/2 88.7 21 50.5 31 48.5 5.1Weight includes a 3 m Short direct sensor set, but is excluding packing.175810725_E1_GB_11.2010MULTICAL® 402D A T A S H E E TWeight includes a 3 m short direct sensor set, but is excluding packing.Flow sensor with DN25 to DN50 flange connectionDimentional sketchesNom.diameterBolts Approx. weightL M H2 D H k Number Thread d2 [kg]DN25 260 L/2 92.5 115 106 85 4 M12 14 5.6DN40 300 L/2 92.5 150 136 110 4 M16 18 8.9DN50 270 155 92.5 165 145 125 4 M16 18 10.718 5810725_E1_GB_11.2010MULTICAL® 402D A T A S H E E TPressure loss MULTICAL0,010,110,1 1 10 100Flow [m³/h]?p [bar]A B C ?p MULTICAL® 402Graph qp[m³/h]Nom. diameter[mm]kv Q@0,25 bar[m³/h]A 0.6 & 1.5 DN15 & DN20 3 1.5B 2.5 & 3.5 & 6 DN20 & DN25 13.5 6.8C 10 & 15 DN40 & DN50 43 21.7195810725_E1_GB_11.2010MULTICAL® 402D A T A S H E E TType number Description 402-000-1000-000 Battery module 2 pcs. AA-cell402-000-2000-000 D-cell battery402-000-7000-000 230 VAC supply module402-000-8000-000 24 VAC supply module66-99-097 USB cable with galvanic separation66-99-099 Infra-red optical reading head with USB plug66-99-102 Infra-red optical reading head RS232 with D-sub 9F66-99-106 Data cable RS232, D-sub 9F66-99-372 Pt500 (Heat) Verification Equipment for MULTICAL® 402 (used with METERTOOL)66-99-373 Pt500 (Cooling) Verification Equipment for MULTICAL® 402 (used with METERTOOL)66-99-712 METERTOOL for MULTICAL® 40266-99-713 METERTOOL LogView for MULTICAL® 402AccessoriesGlands including gaskets (PN16)GasketsSize Nipple Union Type No. 2 pcsDN15 R½ G¾ 65-61-323DN20 R¾ G1 65-61-324DN25 R1 G5/4 65-61-325DN40 R1½ G2 65-61-315 For glands For flange meters PN25Size (Union) Type No. Size Type No.G¾ 2210-061 DN20 2210-147G1 2210-062 DN25 2210-133G5/4 2210-063 DN40 2210-132G2 2210-065 DN50 2210-09920 5810725_E1_GB_11.2010MULTICAL® 402D A T A S H E E T
Most popular related searches