JLA Hydro Srl
List regulators references Brochure
Ref. Nb Customer Country Regulator ref. Regulation type Turbine type1 Haxaire France n.a. Water flow regulation for grid-tied operation (water level regulation)Cross-flow JLA 29 runner2 Leroy Belgium n.a. ELC - Electronic load controller for 3-phases synchronous generatorHorizontal Francis3 Dony sprl I Belgium JLA 11-V-2 Synchronization system for grid-tied operation (asynchronous generator) + Trashrack automationCross-flow JLA 294 Centrale de NyakabandaRwanda JLA 11-V-2 Water flow regulation for isolated site (speed regulation)Cross-flow JLA 295 Willot JLA Belgium JLA 11-V-1 Synchronization system for grid-tied operation (synchronous generator - cos phi regulation) + water flow regulation for water level regulationVertical Francis6 Johnsen Australia JLA 11-V-2 Water flow regulation for grid-tied operation (water level regulation)Cross-flow JLA 297 Centrale d'AntétézambatoMadagascar JLA 11-V-2 Water flow regulation for isolated site (speed regulation)Cross-flow JLA 298 Centrale Zoude s.a. Belgium 2x JLA 11-V-1 Synchronization systems for grid-tied Cross-flow JLA 52References list - JLA electronic regulators8 Centrale Zoude s.a. Belgium 2x JLA 11-V-1 Synchronization systems for grid-tied operation (two asynchronous generators) + Water flow regulation (water level regulation) + Remote control + Automatic computer data archiving + Trashrack automationCross-flow JLA 529 Dony sprl II Belgium JLA 11-V-2 Synchronization system for grid-tie operationCross-flow JLA 2910 Colorado de Mayari Cuba JLAR-ELC-27TPELC - 27kW Electronic load controller for 3-phases synchronous generatorPelton11 Omkoi hydro power stationThaïland JLAR-ELC-VC-136TPELC - 36kW Mixed regulation "water flow + load" for 3-phases synchronous generatorCross-flow JLA 2912 La Cabane du Petit MountetSwitzerland JLAR-IGC-12TPIGC - 12kW Induction generator controller for 3-phases induction generatorPelton13 L. Marchesani France JLAR-IGC-9SP IGC - 9kW Induction generator controller for 1-phase induction generatorCross-flow JLA 2914 Guanayara Cuba JLAR-ELC-30TPELC - 30 kW Electronic load controller for 3-phases synchronous generatorPelton15 Moulin de La Hogue France JLAR-IGC-18SPIGC - 18kW Induction generator controller for 1-phase induction generatorCross-flow JLA 2916 Le Mouliot France JLAR-IGC-9SP IGC - 9kW Induction generator controller for 1-phase induction generatorCross-flow JLA 2917 M'Bayo D.R. Congo JLAR-ELC-30TPELC - 30kW Electronic load controller for 3-phases synchronous generatorCross-flow JLAKit18 Grand Séminaire de KabwéD.R. Congo JLAR-ELC-VC-45TPELC - 45kW Mixed regulation "water flow + load" for 3-phases synchronous generatorCross-flow JLA 29
Stay in the loop!
Select your areas of interest to receive industry updates.