Eaton Corporation

Loadcenters and Circuit Breakers Brochure

Volume 1—Residential and Light Commercial CA08100002E—September 2014 www.eaton.com V1-T1-1111111111111111111111111111111Loadcenters and Circuit BreakersResidential Loadcenters and Breaker Family1.1 Type CH Loadcenters and Circuit Breakers Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-2Single-Phase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-7Three-Phase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-12CH Specialty Products. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-14Spa Panels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-14Surge Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-15Plug-On Neutral Loadcenter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-17Type CH Renovation Loadcenter . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-18Type CH Retrofit Interior Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-19Non-Metallic Loadcenter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-21CH Circuit Breakers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-311.2 Type BR Loadcenters and Circuit BreakersOverview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-42Single-Phase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-48Three-Phase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-54BR Specialty Products . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-57Spa Panels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-57Riser Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-58Type BR Renovation Loadcenter. . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-59Type BR Retrofit Interior Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-72BR Circuit Breakers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-751.3 Loadcenter Interiors/OEM LoadcentersProduct Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-88Standards and Certifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-89Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-891.4 Enclosed BreakersProduct Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-93Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-941.5 Classified Circuit BreakersProduct Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-96Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-97Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-99Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-99Wiring Diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-100LearnOnlineV1-T1-2 Volume 1—Residential and Light Commercial CA08100002E—September 2014 www.eaton.com1111111111111111111111111111111.1 Loadcenters and Circuit BreakersType CH Loadcenters and Circuit BreakersEaton Type CH Convertible Family ContentsDescription PageOverviewProduct Description . . . . . . . . . . . . . . . . . . . . . V1-T1-3Features, Benefits and Functions . . . . . . . . . . V1-T1-3Standards and Certifications . . . . . . . . . . . . . . V1-T1-4Catalog Number Selection. . . . . . . . . . . . . . . . V1-T1-6Product Selection. . . . . . . . . . . . . . . . . . . . . . . V1-T1-7Technical Data and Specifications . . . . . . . . . . V1-T1-29CH Specialty Products . . . . . . . . . . . . . . . . . . . . . V1-T1-14CH Loadcenter Options and Accessories . . . . . . . V1-T1-22CH Circuit Breakers. . . . . . . . . . . . . . . . . . . . . . . . V1-T1-31OverviewProduct Selection GuideCH Loadcenters DescriptionServiceSingle-phase, three-wire, 120/240 VacThree-phase, three-wire, 240 V corner grounded deltaThree-phase, four-wire, 208Y/120 VacThree-phase, three-wire, 240 Vac deltaShort-Circuit Current Rating10 kAIC: All single- and three-phase loadcenters 40–400 A, 2–42 circuits except when series ratings are applied25 kAIC: All factory-installed main breakers single-phase loadcenters rated 150–225 A using Type CSR main breakers35 kAIC available on convertible units using CSH main breaker42 and 100 kAIC are available on some styles: single-phase and three-phaseMain Breaker/Main Lug LoadcentersSingle-phaseMain breaker: 100, 125, 150, 200, 225, 400 AMain lugs: 40, 70, 125, 150, 200, 225, 400 AThree-phaseMain breaker: 150, 200, 225, 300, 400 AMain lugs: 125, 150, 200, 225, 400 AConvertible LoadcentersMain breaker or main lugs: single-phase up to 225 ABranch BreakersType CH: 10–150 A. Single-, two- and three-pole. Selected amperages available in shunt trip, HACR and switching dutyGround fault circuit interruptors: 15–60 AType CH-HID: 15–30 A. Single-, two- and three-poleCH-HM high magneticCH-M50 high ambientType CH-AFCI arc fault circuit interrupterType CHP: 10–125 A. Single-, two- and three-pole. three-position commercial tripSelected amperages available in HACR switching dutyType CHP-HID: 15–30 A. Single-, two- and three-poleType CHP-GFCI: 15–30 A. Single-pole ground fault breakersEnclosuresNEMA® Type 1 indoor NEMA Type 3R outdoor.Loadcenter and Breaker AccessoriesBranch circuit breaker:Auxiliary componentsHold-down kitsHandle tiesLockoffsLockdogsComplete line of ground bar kits 5, 10, 14 and 21 circuits, some with additional #2/0 lugsEach terminal will accommodate: (3) #14–#10 Cu/Al or (1) #14–#4 Cu/AlSub-feed lugs 125, 150 A—two- and three-poleShunt tripsUniversal rainproof conduit hubs Group One: 3/4, 1, 1-1/4, 1-1/2, 2 inches (19.1, 25.4, 31.8, 38.1, 50.8 mm) Group Two: 2, 2-1/2, 3 inches (50.8, 63.5, 76.2 mm)Adapter plateBussingSilver flash plated copper bus is a standard featureVolume 1—Residential and Light Commercial CA08100002E—September 2014 www.eaton.com V1-T1-31111111111111111111111111111111.1Loadcenters and Circuit BreakersType CH Loadcenters and Circuit BreakersProduct Description Loadcenters are enclosures specifically designed to house the branch circuit breakers and wiring required to distribute power to individual circuits. They contain either a main breaker when used at the service entrance point or a main lug when used as a sub-panel to add circuits to existing service. The main breaker protects the main entire panel and can be used as a service disconnect. The branch breakers protect the wires leading to individual electrical loads such as fixtures and outlets.Features, Benefits and FunctionsLoadcenter ConstructionEaton’s Type CH loadcenters feature silver flash plated copper bus in all interiors. Stabs are rated 200 A throughout the CH line. Therefore, the sum of the handle ratings connected to any one stab is limited to 200 A maximum. NEMA 1 boxes are manufactured from cold rolled 16 gauge sheet steel. Raintight boxes are manufactured from galvanized steel. All boxes and trims are finished using an electrostatic powder coat, baked urethane paint process.NeutralsEaton Type CH loadcenters feature two types of neutrals:Insulated/Bondable Split NeutralPanels are supplied with split insulated neutrals with an insulated cross strap. For service entrance applications, the neutral must be bonded by using the bonding strap supplied with the panel. For non-service entrance (sub-panel) applications, the panel may be installed with the bonding strap not connected to the neutral. Separate ground bars must be used on non-service entrance panels.Insulated/Bondable Single NeutralPanels are supplied with a single insulated neutral. For service entrance applications, all that is required to bond the neutral is to loosen the bonding screw and the neutral screw directly beside it, insert the bonding strap into the neutral bar, and re-tighten both connections. The single neutral can be moved by the contractor to the other side of the panel, if desired. When used as a service entrance panel, unused neutral connections may be used for the termination of equipment grounds. For non-service entrance (sub-panel) applications, the panel may be installed with the bonding strap not connected to the neutral. Separate ground bars must be used on non-service entrance panels.Inboard Plug-On NeutralCode changes and higher safety standards are leading to more arc fault circuit interrupter (AFCI) installations. With the electrical contractor in mind, Eaton has revolutionized the way Combination AFCIs are installed with the Plug-on Neutral line of loadcenters and breakers. This unique product solution enables the contractor to connect the breaker directly to the neutral bar, eliminating the need for wiring a pigtail.GroundsIn service entrance applications where the neutral is bonded, unused neutral holes may be usedfor terminating ground conductors. In sub-feed panels, the neutral must be isolated (non-bonded), and ground wires must be terminated on a separate ground bar.The insulated/bondable single/split neutral panels have sufficient terminations for both ground and neutral conductors. The insulated/bondable single split neutral panels are supplied with a separate factory-installed ground bar if the catalog number contains a “G.” If not, a separate ground bar should be installed. Insulated/Bondable Single Neutral panels are supplied without a ground bar (unless otherwise noted), and ground bar kits, if needed, must be purchased separately.V1-T1-4 Volume 1—Residential and Light Commercial CA08100002E—September 2014 www.eaton.com1111111111111111111111111111111.1 Loadcenters and Circuit BreakersType CH Loadcenters and Circuit BreakersStandards and CertificationsUL® ListingsAll Eaton Type CH loadcenters are listed under UL File E8741.Neutral and Ground TerminalsThe standard terminals on grounds and neutrals are rated to accept (3)—#14–#10 Cu/Al or (1)—#14–4 wires. For larger cables, add-on neutral lugs may be ordered from the Accessories.Note: NEC® allows only one current carrying conductor per hole on neutrals unless otherwise noted.Bottom-Fed LoadcentersWhen the power cable is brought into the loadcenter from below the panel; then the main lug panels, and single-phase, 225 A and below, loadcenters can be rotated 180 degrees to allow straight-in wiring of power cables to the main terminals. Because the CSR main circuit breaker handle operates horizontally, the orientation of the main circuit breaker handle is consistent with the requirements of NEC Article 240.81.Gutter SplicingLoadcenters are not UL listed as wiring troughs. Therefore, gutter splicing of riser cables to tap off to the main device is not permitted. Refer to NEC Article 373.8.Fire RatingDue to the numerous openings in both loadcenter boxes and trims, they should not be mounted in firewalls. There is no approval method for sealing the enclosures for this application.Date CodeThe date of manufacture of each loadcenter is printed on the outside of the carton as well as inside the loadcenter. On the carton, the date code is printed on the end carton label. In the loadcenter, the date code is located on the small white label located on the right side wall (with the main device on top).The date code is in the following format: F # # # &. The “F” is the numeric code for the Lincoln, IL plant, and the three numbers are the year and week of manufacture, e.g., 023. The “&” sign at the end signifies the decade of the 2000s. The “” at the end signifies the decade of the 2010s. Therefore, the date code F023& would indicate that the product was manufactured in the 23rd week of 2000. The 1980s are represented by a “+” sign and the 1990s are represented by a “=” at the end of the code.Plug-On Type CH BreakersQuick-make, quick-break switch mechanism combined with inverse time element tripping operation and trip-free handle design. Type CH circuit breakers trip to the OFF position eliminating nuisance callbacks. The thermal-magnetic trip curve avoids nuisance tripping on mild overloads while reacting almost instantaneously to severe short-circuit conditions. CHF breakers include a ‘trip flag’ to differentiate between a tripped breaker and one that has been turned off. Multipole breakers have internal common trip connection to operate all poles simultaneously. Handles are marked with ON-OFF indication and ampere rating of the breaker. Type CH breakers meet UL Standard 489, NEMA standards, and Federal Spec Classification W-C 375 b/Gen. They are UL listed under File Number E11713, E8741, E3624 and E51287: and CSA® certified file number LR87196, except Type CHT breakers.Type CH Circuit Breaker RatingsSingle- and double-pole CH breakers rated 15 and 20 A have low instantaneous magnetic trip levels. The 15 and 20 A breakers with “HM” suffix have high magnetic trip settings recommended for circuits with inherently high inrush currents. All Type CH breakers are marked for heating, air conditioning and refrigeration (HACR) equipment application. Single-pole 15–20 A breakers are also suitable for switching duty (SWD). Shunt trip coils operate on 120 Vac and require one additional pole space per breaker.Volume 1—Residential and Light Commercial CA08100002E—September 2014 www.eaton.com V1-T1-51111111111111111111111111111111.1Loadcenters and Circuit BreakersType CH Loadcenters and Circuit BreakersType CH LoadcenterWarrantyThe minimum warranty for residential loadcenters, breakers and surge protection devices shall be as follows:? Lifetime loadcenter warranty? Lifetime warranty on CH circuit breakers? Lifetime warranty on CHSPT2ULTRA including $75,000 connected equipment warranty? 1-year warranty on plug-in surge protective device (CHSA)Single Keyhole Mounting One keyhole at the top and bottom provides easier mounting and levelingNeutral Bus (Strap) Easily removable for sub-panel applications Bonding Z-Strap Provides easy ?eld conversion for service entrance applicationsTwin Neutral Bars Minimum 150% neutral capacityExtra 1.5 inch Knockout (38.1 mm) Larger knockout provides easier installation and time savings for renovation installations“Tangential” Center Knockout Easier installation for conduit applicationsCommercial Grade Main Breaker 25 kAIC series rated main breaker in 150 A–225 A load-centers. 35, 42 and 100 kAIC series ratings are available Optional convertible design— reduces inventory requirements2/0 Lug Easily removable and can be installed in any location on the neutral barDrywall Marking on Enclosure Indicates proper mounting depth for ?ush applicationsOne Piece Silver-Flashed Copper Bus Provides superior conductivity, corrosion resistance and durabilitySteel Backpan Provides solid and reliable breaker mounting—single piece design for stability and durability Top or Bottom Feed Straight-in wiring saves labor and material One panel for either top or bottom applicationsType CHF AFCI/GFCI/Thermal - Magnetic Breakers Advanced electronics effectively reduce nuisance tripping CHF AFCI breakers have a standard diagnostic LED indicating 1 of 7 trip codes Mechanical ?ag for trip indication (on thermal-magnetic AFCI and GFCI) All CH breakers provide industry exclusive 2-position handle with simple 1 step resetUnique Sandalwood Finish Aesthetically appealing, scratch-resistant powder coating¦¦¦¦¦¦¦¦¦¦¦¦¦¦¦¦¦¦¦V1-T1-6 Volume 1—Residential and Light Commercial CA08100002E—September 2014 www.eaton.com1111111111111111111111111111111.1 Loadcenters and Circuit BreakersType CH Loadcenters and Circuit BreakersCatalog Number SelectionLoadcenters 100–225 A and 12–42 Circuits Indoor Covers Ordered Separately Note: All combinations are not valid, refer to the catalog section.LC TypeType CH 3/4-inch (19.1 mm)branch circuit breakersNumber of CircuitsSelection circuits2481214161820222428303242Main DeviceL = Main lug onlyB = Main breakerN = ConvertibleH = High AIC main breakerCH 42 B 200 K ConstructionBlank = StandardPN = Plug-on neutralPhasesBlank = Single-phase3 = Three-phase AccessoriesBlank = StandardEC = Surge readySUR = Surge factory installedBus Amperes4070100125150200225Box SizesBCDEGJKLR = Outdoor (no cover)CH 8 K F Type CHLoadcenterCover SeriesFactory OptionsBlank = Standard SUR = Surge/surge readyAccessoriesBlank = StandardM = Mechanical interlockMountingF = Combination flush/surfaceS = SurfaceBox SizeIndicated in loadcentercatalog numberVolume 1—Residential and Light Commercial CA08100002E—September 2014 www.eaton.com V1-T1-71111111111111111111111111111111.1Loadcenters and Circuit BreakersType CH Loadcenters and Circuit BreakersProduct SelectionSingle-Phase—Main Circuit Breaker Loadcenters—10/25 kAIC Single-Phase Three-Wire—120/240 Vac—Insulated/Bondable Split Neutral (Unless Otherwise Noted)Notes1 All main circuit breaker loadcenters are listed for use as service entrance equipment.2 Ground bar kits priced separately. See Page V1-T1-25.3 Combination style covers may be used in surface or flush applications.4 Can be top or bottom fed by rotating the enclosure and trim 180 degrees.5 Rainproof panels are furnished with hub closure plates. For rainproof hubs, refer to Page V1-T1-25.6 Panel includes #4–300 kcmil feed-through lugs.7 This cover is for flush applications only (not combination).Box sizes Pages V1-T1-27 and V1-T1-28.MainBreakerTypeMainAmpereRatingMaximum Number3/4-Inch (19.1 mm)of PolesEnclosureTypeBoxSizeWire Size RangeCu/Al 60 °C or 75 °Cfor Main BreakerLoadcenter 12Catalog NumberLoadcenter CoverCatalog NumberCombination 3 SurfaceCH10 kAIC100 14 Indoor B #6–1/0 CH14B100B 4 CH8BF CH8BS14 Outdoor B #6–1/0 CH14B100R 5 — —18 Indoor C #6–1/0 CH18B100C 4 CH8CF CH8CS18 Outdoor C #6–1/0 CH18B100R 5 — —22 Indoor C #6–1/0 CH22B100C 4 CH8CF CH8CS22 Outdoor C #6–1/0 CH22B100R 5 — —30 Indoor D #6–1/0 CH30B100D 4 CH8DF CH8DS30 Outdoor D #6–1/0 CH30B100R 5 — —125 22 Indoor C #6–1/0 CH22B125C 4 CH8CF CH8CS22 Outdoor C #6–1/0 CH22B125R 5 — —30 Indoor D #6–1/0 CH30B125D 4 CH8DF CH8DS30 Outdoor D #6–1/0 CH30B125R 5 — —CSR25 kAIC150 8 Outdoor E #2–300 kcmil CH8B150RF 6 — —24 Indoor E #2–300 kcmil CH24B150E 4 CH8EF CH8ES24 Outdoor E #2–300 kcmil CH24B150R 5 — —32 Indoor J #2–300 kcmil CH32B150J 4 CH8JF CH8JS32 Outdoor J #2–300 kcmil CH32B150R 5 — —200 8 Outdoor E #2–300 kcmil CH8B200RF 6 — —24 Indoor E #2–300 kcmil CH24B200E 4 CH8EF CH8ES24 Outdoor E #2–300 kcmil CH24B200R 5 — —32 Indoor J #2–300 kcmil CH32B200J 4 CH8JF CH8JS32 Outdoor J #2–300 kcmil CH32B200R 5 — —42 Indoor K #2–300 kcmil CH42B200K 4 CH8KF CH8KS42 Outdoor K #2–300 kcmil CH42B200R 5 — —225 32 Indoor J #2–300 kcmil CH32B225J 4 CH8JF CH8JS32 Outdoor J #2–300 kcmil CH32B225R 5 — —42 Indoor K #2–300 kcmil CH42B225K 4 CH8KF CH8KS42 Outdoor K #2–300 kcmil CH42B225R 5 — —DK10 kAIC300 42 Indoor PM (2) 3/0–250 kcmil CH42PM300 CH7PMF 7 CH7PMS400 42 Indoor PM (2) 3/0–250 kcmil CH42PM400 CH7PMF 7 CH7PMSCH42B200KV1-T1-8 Volume 1—Residential and Light Commercial CA08100002E—September 2014 www.eaton.com1111111111111111111111111111111.1 Loadcenters and Circuit BreakersType CH Loadcenters and Circuit BreakersSingle-Phase—High Interrupting Rated Main Circuit Breaker Loadcenters—100 kAIC Single-Phase Three-Wire—120/240 Vac—Insulated/Bondable Split NeutralNotes1 All main circuit breaker loadcenters are listed for use as service entrance equipment.2 Combination style covers may be used in surface or flush applications.3 Loadcenter can be top or bottom fed by rotating the enclosure and trim 180 degrees.4 Rainproof panels are furnished with hub closure plates. For rainproof hubs, refer to Page V1-T1-25. 5 Series rated for 100 kAIC with all Types CH, CHT and CHP breakers.MainBreakerTypeMainAmpereRatingMaximum Number3/4-Inch (19.1 mm)PolesEnclosureTypeBoxSizeWire Size RangeCu/Al 60 °C or 75 °Cfor Main BreakerLoadcenter 1Catalog NumberLoadcenter CoverCatalog NumberCombination 2 SurfaceCHB4100 kAIC 5100 32 Indoor L #6–1/0 CH32H100L 3 CH8LF CH8LS32 Outdoor L #6–1/0 CH32H100R 4 — —CHH100 kAIC 5150 32 Indoor L #2/0–300 kcmil CH32H150L CH8LF CH8LS32 Outdoor L #2/0–300 kcmil CH32H150R 4 — —200 32 Indoor L #2/0–300 kcmil CH32H200L CH8LF CH8LS32 Outdoor L #2/0–300 kcmil CH32H200R 4 — —42 Indoor L #2/0–300 kcmil CH42H200L CH8LF CH8LS42 Outdoor L #2/0–300 kcmil CH42H200R 4 — —225 42 Indoor L #2/0–300 kcmil CH42H225L CH8LF CH8LS42 Outdoor L #2/0–300 kcmil CH42H225R 4 — —Volume 1—Residential and Light Commercial CA08100002E—September 2014 www.eaton.com V1-T1-91111111111111111111111111111111.1Loadcenters and Circuit BreakersType CH Loadcenters and Circuit BreakersSingle-Phase—Main Lug LoadcentersSingle-Phase Three-Wire—120/240 Vac—Insulated/Bondable Single NeutralNotes1 Requires the use of Type CHT breakers.2 Ground bar kits priced separately, see Page V1-T1-25.– For 2/4 and 6/12 circuit loadcenters use Type GBK5 or GBK520 ground bar– For 4/8 and 8/16 circuit loadcenters use Type GBK10 ground bar– Ground bars mount to the left side wall of the enclosure for the 4/8, 6/12 and 8/16 circuit loadcenters3 Suitable for use as service equipment when not more than two service disconnecting mains are provided or when not used as a lighting and appliance panelboard(see Article 408.34 of the NEC).4 Rainproof panels are furnished with hub closure plates. For rainproof hubs, refer to Page V1-T1-25.5 For use as service entrance applications only.6 Neutral/ground holes (6) #14–6 and (3) #14–2/0 AWG Cu/AI.7 Suitable for use as service equipment when not more than two service disconnecting mains are provided or when not more than six service disconnecting mains are provided and when not used as a lighting and appliance panelboard (see Article 408.34 of the NEC).8 Suitable for use as service equipment when a main breaker is used or when not more than six service disconnecting mains are provided and when not used as a lighting and appliance panelboard (see Article 408.34 of the NEC).Box sizes Pages V1-T1-27 and V1-T1-28.MainAmpereRatingMaximum Number3/4-Inch (19.1 mm) EnclosureTypeType of Trim(Included)BoxSizeWire Size RangeCu/Al 60 °C or 75 °Cfor Main LugsLoadcenterCatalog NumberSpace Poles40 2 4 1 Indoor Surface (no door) 5 #14–6 CH2L40SP 232 4 1 Outdoor — 5R #14–6 CH2L40RP 2342 4 1 Indoor Flush (no door) 5 #14–6 CH2L40FP 2370 2 4 1 Indoor Surface (no door) 5 #14–2 CH2L70SP 232 4 1 Outdoor — 5R #14–2 CH2L70RP 2342 4 1 Indoor Flush (no door) 5 #14–2 CH2L70FP 23125 2 4 1 Indoor Surface (no door) 6 #14–1/0 CH2L125SP 232 4 1 Outdoor — 6R #14–1/0 CH2L125RP 2342 2 Outdoor — — #14–1/0 CH2L125RSE2P 4562 4 1 Indoor Flush (no door) 6 #14–1/0 CH2L125FP 234 8 1 Indoor Surface (no door) 7 #14–1/0 CH4L125SP 274 8 1 Outdoor — 7R #14–1/0 CH4L125RP 2474 8 1 Indoor Flush (no door) 7 #14–1/0 CH4L125FP 276 12 1 Outdoor — 6R #14–1/0 CH6L125R 2678 16 1 Indoor Surface (no door) 7 #6–1/0 CH8L125SP 288 16 1 Outdoor — 7R #6–1/0 CH8L125RP 2678 16 1 Indoor Flush (no door) 7 #6–1/0 CH8L125FP 28Surface OutdoorFlush OutdoorSurface (No Door)Flush (No Door)OutdoorV1-T1-10 Volume 1—Residential and Light Commercial CA08100002E—September 2014 www.eaton.com1111111111111111111111111111111.1 Loadcenters and Circuit BreakersType CH Loadcenters and Circuit BreakersSingle-Phase Three-Wire—120/240 Vac—Insulated/Bondable Split Neutral—Factory-Installed Ground BarNotes1 Suitable for use as service equipment when not more than six disconnecting means are provided and when not used as a lighting and appliance panelboard (see Article 408.34 of the NEC).2 Rainproof panels are furnished with hub closure plates. For rainproof hubs, refer to Page V1-T1-25.3 Suitable for use as service equipment when a circuit breaker is used as a main breaker. The main breaker is backfed and requires hold-down bracket kit catalog number CH125RB.4 Suitable for use as service equipment when a circuit breaker is used as a main breaker. The main breaker is backfed and must be a Type CHB. The breaker cannot be a Type CH.5 This cover is for flush application only (not combination).Box sizes Pages V1-T1-27 and V1-T1-28.MainAmpereRatingMaximum Number3/4-Inch (19.1 mm)PolesEnclosureTypeBoxSizeWire Size RangeCu/Al 60 °C or 75 °Cfor Main LugsLoadcenterCatalog Number Loadcenter CoverCatalog NumberCombination Surface125 12 Indoor B #6–2/0 CH12L125B 1 CH8BF CH8BS12 Outdoor B #6–2/0 CH12L125R 12 — —16 Indoor B #6–2/0 CH16L125B 1 CH8BF CH8BS16 Outdoor B #6–2/0 CH16L125R 12 — —20 Indoor C #6–2/0 CH20L125C 1 CH8CF CH8CS20 Outdoor C #6–2/0 CH20L125R 12 — —24 Indoor C #6–2/0 CH24L125C 1 CH8CF CH8CS24 Outdoor C #6–2/0 CH24L125R 12 — —150 24 Indoor D #4–300 kcmil CH24L150D 1 CH8DF CH8DS24 Outdoor D #4–300 kcmil CH24L150R 23 — —32 Indoor D #4–300 kcmil CH32L150D 1 CH8DF CH8DS32 Outdoor D #4–300 kcmil CH32L150R 23 — —200 12 Indoor D #4–300 kcmil CH12L200D 1 CH8DF CH8DS12 Outdoor D #4–300 kcmil CH12L200R 23 — —16 Indoor D #4–300 kcmil CH16L200D 1 CH8DF CH8DS16 Outdoor D #4–300 kcmil CH16L200R 23 — —225 24 Indoor D #4–300 kcmil CH24L225D 1 CH8DF CH8DS24 Outdoor D #4–300 kcmil CH24L225R 23 — —32 Indoor D #4–300 kcmil CH32L225D 1 CH8DF CH8DS32 Outdoor D #4–300 kcmil CH32L225R 23 — —42 Indoor G #4–300 kcmil CH42L225G 3 CH8GF CH8GS42 Outdoor G #4–300 kcmil CH42L225R 23 — —400 42 Indoor P (2) 1/0–300 kcmil(1) 750 kcmilCH42PL400 4 CH7PF 5 CH7PSCH42L225GVolume 1—Residential and Light Commercial CA08100002E—September 2014 www.eaton.com V1-T1-111111111111111111111111111111111.1Loadcenters and Circuit BreakersType CH Loadcenters and Circuit BreakersConvertible Loadcenters MCB or MLO—Base Units and Main Devices—10/25/35 kAIC Complete assembly consists of: loadcenter, cover, and either main breaker kit or main lug kit.Indoor—Single-Phase—Three-Wire—120/240V—Insulated/Bondable Split Neutral—Top or Bottom FeedOutdoor—Single-Phase—Three-Wire—120/240V—Insulated/Bondable Split Neutral (Unless Otherwise Noted) Notes1 Panel does not include main. Order main breaker or main lug kit separately.2 If 35 kAIC is required, use CSH breaker.3 Hold-down kit included.4 35 kAIC series combination rating is obtained when Types CH, CHT and CHP branch breakers are used with CSH main.5 Rainproof panels are furnished with hub closure plates. For rainproof hubs, refer to Page V1-T1-25.6 Includes feed-through lugs for both phase and neutral conductors.7 Insulated/bondable single neutral.Interrupting rating depends on main circuit breaker selected.MaximumMain AmpereRatingMaximumNumber of Single PolesBoxSize Loadcenter Box and PanelCatalog Number 1Loadcenter CoverCatalog Number Main Lug Kit Main Breaker KitCatalog NumberCombination SurfaceWire SizeCatalog NumberkAIC RatingWire Size125 22 C CH22N125C CH8CF CH8CS #10–1/0 CHL125N 10 #10–1/0 CH2100N 3 —CH2125N 3 —200 32 J CH32N200J CH8JF CH8JS #4–300kcmilCHL225N 25/35 2 #2–300kcmilCSR2125N CSH2125N 4CSR2150N CSH2150N 4CSR2175N CSH2175N 4CSR2200N CSH2200N 4225 42 K CH42N225K CH8KF CH8KS #4–300kcmilCHL225N 25/35 2 #2–300kcmilCSR2125N CSH2125N 4CSR2150N CSH2150N 4CSR2175N CSH2175N 4CSR2200N CSH2200N 4CSR2225N CSH2225N 4MaximumMain AmpereRatingMaximumNumber of Single PolesBoxSizeLoadcenter Boxand PanelCatalog Number 1Main Lug KitCatalog NumberMain Breaker KitCatalog NumberWire SizekAIC RatingWire Size125 22 C CH22N125R 5 #10–1/0 CHL125N 10 #10–1/0 CH2100N 3 —CH2125N 3 —200 8 E CH8N200RF 567 #4–300 kcmil CHL225N 25/35 2 #2–300 kcmil CSR2125N CSH2125NCSR2150N CSH2150NCSR2175N CSH2175NCSR2200N CSH2200N200 32 J CH32N200R 5 #4–300 kcmil CHL225N 25/35 2 #2–300 kcmil CSR2125N CSH2125N 4CSR2150N CSH2150N 4CSR2175N CSH2175N 4CSR2200N CSH2200N 4225 42 K CH42N225R 5 #4–300 kcmil CHL225N 25/35 2 #2–300 kcmil CSR2125N CSH2125N 4CSR2150N CSH2150N 4CSR2175N CSH2175N 4CSR2200N CSH2200N 4CSR2225N CSH2225N 4V1-T1-12 Volume 1—Residential and Light Commercial CA08100002E—September 2014 www.eaton.com1111111111111111111111111111111.1 Loadcenters and Circuit BreakersType CH Loadcenters and Circuit BreakersThree-Phase—Main Circuit Breaker Loadcenters—10 kAIC Three-Phase Four-Wire—208Y/120 Vac or 240 Vac Insulated/Bondable Split NeutralThree-Phase—High Interrupting Rated Main Circuit Breaker Loadcenters—100 kAIC Three-Phase Four-Wire—208Y/120 Vac or 240 Vac Insulated/Bondable Split NeutralNotes1 All main circuit breaker loadcenters are listed for use as service entrance equipment.2 Ground bar kits priced separately. For ground bar kits, see Page V1-T1-25.3 Rainproof loadcenters are furnished with hub closure plates. For rainproof hubs, refer to Page V1-T1-25.4 This cover for flush application only (not combination).5 100 kAIC series combination rating is obtained when Types CH and CHP branch breakers are used with CHH main.MainBreakerTypeMainAmpereRatingMaximum Number3/4-Inch (19.1 mm)PolesEnclosureTypeBoxSize Wire Size RangeCu/Al 60 °C or 75 °Cfor Main BreakerLoadcenter 12Catalog NumberLoadcenter CoverCatalog NumberCombination SurfaceCC10 kAIC150 30 Indoor L #1–4/0 CH30B3150L CH8LF CH8LS30 Outdoor L #1–4/0 CH30B3150R 3 — —200 30 Indoor L #2/0–300 kcmil CH30B3200L CH8LF CH8LS30 Outdoor L #2/0–300 kcmil CH30B3200R 3 — —42 Indoor L #2/0–300 kcmil CH42B3200L CH8LF CH8LS42 Outdoor L #2/0–300 kcmil CH42B3200R 3 — —225 30 Indoor L #2/0–300 kcmil CH30B3225L CH8LF CH8LS30 Outdoor L #2/0–300 kcmil CH30B3225R 3 — —42 Indoor L #2/0–300 kcmil CH42B3225L CH8LF CH8LS42 Outdoor L #2/0–300 kcmil CH42B3225R 3 — —400 42 Indoor PM (2) 3/0–350 kcmil CH424PM400 CH7PMF 4 CH7PMSMain Breaker TypeMain AmpereRatingMaximum Number 3/4-Inch (19.1 mm)of PolesEnclosureTypeBox SizeWire Size Range Cu/Al 60 °C or 75 °Cfor Main BreakerLoadcenter Catalog Number 12Loadcenter Cover Catalog NumberCombination SurfaceCHH100 kAIC 5200 30 Indoor L #2/0–300 kcmil CH30H3200L CH8LF CH8LS30 Outdoor L #2/0–300 kcmil CH30H3200R 3 — —42 Indoor L #2/0–300 kcmil CH42H3200L CH8LF CH8LS42 Outdoor L #2/0–300 kcmil CH42H3200R 3 — —225 42 Indoor L #2/0–300 kcmil CH42H3225L CH8LF CH8LS42 Outdoor L #2/0–300 kcmil CH42H3225R 3 — —CH42B3200LVolume 1—Residential and Light Commercial CA08100002E—September 2014 www.eaton.com V1-T1-131111111111111111111111111111111.1Loadcenters and Circuit BreakersType CH Loadcenters and Circuit BreakersThree-Phase—Main Lug LoadcentersThree-Phase Four-Wire—208Y/120 Vac or 240 Vac Insulated/Bondable Split Neutral (Unless Otherwise Noted)Notes1 Requires the use of Type CHT breakers.2 Suitable for use as service equipment when not more than two service disconnecting means are provided or when not more than six service disconnecting means are provided and when not used as a lighting and appliance panelboard (see Article 408.34 of the NEC).3 Ground bar kits priced separately, see Page V1-T1-25.– Use GBK10 ground bar– Ground bars mount to the left side wall of the enclosure.4 Insulated/bondable single neutral.5 Rainproof loadcenters are furnished with hub closure plates. For rainproof hubs, refer to Page V1-T1-25.6 Ground bar Type GBK14 is installed.7 Suitable for use as service equipment when a circuit breaker is used as a main breaker. The main breaker is backfed and requires hold-down bracket kit catalog number Type CH125RB. Suitable for use as service equipment when not more than six service disconnecting means are provided and when not used as a lighting and appliance panelboard (see Article 408.34 of the NEC). 8 Ground bar Type GBK21 is installed.9 Suitable for use as service equipment when a circuit breaker is used as a main breaker. The main breaker is backfed and requires hold-down kit catalog number Type CH125RB.j For ground bar kits, see Page V1-T1-25. k Suitable for use as service equipment when a circuit breaker is used as a main breaker. The main breaker is backfed and must be a Type CHB. The breaker cannot be a Type CH.l This cover for flush application only (not combination).Box sizes Pages V1-T1-27 and V1-T1-28.MainAmpereRatingMaximum Number3/4-Inch (19.1 mm) EnclosureTypeType of TrimIncludedBoxSizeWire Size RangeCu/Al 60 °C or 75 °Cfor Main LugsLoadcenterCatalog NumberLoadcenter Cover Catalog NumberSpaces Poles Combination Single125 6 12 1 Indoor Surface, no door 7 #14–1/0 CH6L3125SP 234 — —6 12 1 Outdoor — 7R #14–1/0 CH6L3125RP 2345 — —6 12 1 Indoor Flush, no door 7 #14–1/0 CH6L3125FP 234 — —12 12 Indoor — B #6–2/0 CH12L3125B 67 CH8BF CH8BS12 12 Outdoor — B #6–2/0 CH12L3125R 567 — —18 18 Indoor — C #6–2/0 CH18L3125C 67 CH8CF CH8CS18 18 Outdoor — C #6–2/0 CH18L3125R 678 — —24 24 Indoor — C #6–2/0 CH24L3125C 67 CH8CF CH8CS24 24 Outdoor — C #6–2/0 CH24L3125R 678 — —150 30 30 Indoor — D #4–300 kcmil CH30L3150D 67 CH8DF CH8DS30 30 Outdoor — D #4–300 kcmil CH30L3150R 569 — —225 24 24 Indoor — D #4–300 kcmil CH24L3225D 67 CH8DF CH8DS24 24 Outdoor — D #4–300 kcmil CH24L3225R 569 — —30 30 Indoor — D #4–300 kcmil CH30L3225D 67 CH8DF CH8DS30 30 Outdoor — D #4–300 kcmil CH30L3225R 569 — —42 42 Indoor — G #4–300 kcmil CH42L3225G 89 CH8GF CH8GS42 42 Outdoor — G #4–300 kcmil CH42L3225R 589 — —400 42 42 Indoor — P (2) 1/0–300 kcmil(1) 750 kcmilCH424PL400 jk CH7PF l CH7PSV1-T1-14 Volume 1—Residential and Light Commercial CA08100002E—September 2014 www.eaton.com1111111111111111111111111111111.1 Loadcenters and Circuit BreakersType CH Loadcenters and Circuit BreakersSpa Panels Contents—CH Specialty ProductsDescription PageOverview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-2CH Specialty ProductsSpa PanelsSurge Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-15Plug-On Neutral Loadcenter . . . . . . . . . . . . . . . V1-T1-17Type CH Renovation Loadcenter . . . . . . . . . . . . V1-T1-18Type CH Retrofit Interior Kits . . . . . . . . . . . . . . V1-T1-19CH Loadcenter Options and Accessories. . . . . . . . V1-T1-22CH Circuit Breakers . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-31CH Specialty ProductsSpa PanelsProduct Description:Eaton’s CH Spa Panels are premium factory-assembled “combination” units that provide ground fault protection, as well as a convenient way to turn spa pumps on and off. The NEC requires that all pool and spa pumps be protected by a ground fault interrupter and a disconnect switch mounted within 10 feet of the tub or the spa. Features? Two extra circuits for additional loads ? Limited lifetime warranty ? UL Listed ? Tough powder-coated galvanized steel enclosure ? Factory-installed two-pole ground fault circuit interrupter (GFCI)Quick-ProSMAll you need to know to save time and make more money. Specified on certain Eaton products, the Quick-Pro symbol allows for immediate recognition of products that are designed for straightforward installation. When you see Quick-Pro, you know you can install quickly—sometimes up to 50% less than the usual installation time—and move on to your next job.Product SelectionSingle-Phase Three-Wire—120/240 Vac Insulated/Bondable Neutral—Factory-Installed Ground BarNotes1 Includes a CH230GFI breaker, factory installed, and two extra circuits for convenience.2 Includes a CH240GFI breaker, factory installed, and two extra circuits for convenience.3 Includes a CH250GFI breaker, factory installed, and two extra circuits for convenience.4 Includes a CH260GFI breaker, factory installed, and two extra circuits for convenience.MainAmpere RatingCircuit BreakerIncludedEnclosureTypeType of Trim IncludedBox SizeWire Size Range Cu/Al 60 °C or 75 °C for Main LugsCatalog Number30 CH230GF Outdoor — 5R #14–1/0 CH30SPA 140 CH240GF Outdoor — 5R #14–1/0 CH40SPA 250 CH250GF Outdoor — 5R #14–1/0 CH50SPA 360 CH260GF Outdoor — 5R #14–1/0 CH60SPA 4CH Spa PanelVolume 1—Residential and Light Commercial CA08100002E—September 2014 www.eaton.com V1-T1-151111111111111111111111111111111.1Loadcenters and Circuit BreakersType CH Loadcenters and Circuit BreakersSurge Panel Contents—CH Specialty ProductsDescription PageOverview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-2CH Specialty ProductsSpa Panels . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-14Surge PanelPlug-On Neutral Loadcenter. . . . . . . . . . . . . . . V1-T1-17Type CH Renovation Loadcenter . . . . . . . . . . . V1-T1-18Type CH Retrofit Interior Kits . . . . . . . . . . . . . . V1-T1-19CH Loadcenter Options and Accessories . . . . . . . V1-T1-22CH Circuit Breakers. . . . . . . . . . . . . . . . . . . . . . . . V1-T1-31Surge PanelProduct DescriptionEaton’s Type CH Surge Loadcenter includes a factory-mounted and wired surge suppressor device. There is a knockout in the cover that allows the user to view the status indication lights on the surge suppressor. The CH Surge Loadcenter reduces the surge current, helping protect sensitive home electronic equipment.Save labor by installing a factory-mounted surge protective device.Factory-Installed Surge Protection? Includes a CHSPT2ULTRA and a two-pole 50 A circuit breaker? Increases the effectiveness of surge protection due to reduced lead length? A modified deadfront allows for easy viewing of indicating lightsSurge Ready? Provides a mounting provision for CHSPT2ULTRA? A modified deadfront allows for easy viewing of indicating lightsProduct SelectionSurge Installed LoadcentersNotes1 Order cover separately.2 With main lugs installed.Ampere Rating TypeNumber of CircuitsLoadcenterCatalog NumberLoadcenter Cover Catalog NumberCombination Surface225 Convertible 42 CHSUR42N225L 1 CHSUR8LF CHSUR8LS225 Convertible 2 42 CHSUR42L225L2 1 CHSUR8LF CHSUR8LS200 Main breaker 42 CHSUR42B200L2 1 CHSUR8LF CHSUR8LS225 Convertible 32 CHSUR32N225K 1 CHSUR8KF CHSUR8KS225 Convertible 2 32 CHSUR32L225K 1 CHSUR8KF CHSUR8KS200 Main breaker 32 CHSUR32B200K 1 CHSUR8KF CHSUR8KS150 Main breaker 32 CHSUR32B150K 1 CHSUR8KF CHSUR8KS100 Main breaker 32 CHSUR32B100K 1 CHSUR8KF CHSUR8KS125 Convertible 2 24 CHSUR24L125E 1 CHSUR8EF CHSUR8ES100 Main breaker 24 CHSUR24B100E 1 CHSUR8EF CHSUR8ES200 Convertible 40/40 BRSUR4040N200 Cover included200 Main lug 40/40 BRSUR4040L200 Cover included200 Main breaker 40/40 BRSUR4040B200 Cover included200 Convertible 30/40 BRSUR3040N200 Cover included200 Main lug 30/40 BRSUR3040L200 Cover included200 Main breaker 30/40 BRSUR3040B200 Cover includedV1-T1-16 Volume 1—Residential and Light Commercial CA08100002E—September 2014 www.eaton.com1111111111111111111111111111111.1 Loadcenters and Circuit BreakersType CH Loadcenters and Circuit BreakersSurge Ready Loadcenters (provision only, CHSPT2ULTRA and breaker not included) Main Breaker Kits Main Lug KitsTechnical Data and SpecificationsRatings? Loadcenter? 25 kAIC main breaker, main lug only, and convertible main breaker/main lug? Factory installed or provision for field-installed surge suppressor? Top or bottom feed? Surge protective device (CHSPT2ULTRA)? Nominal discharge current: 20 kA (In)? Surge current capacity per phase: 108 kA? Warranty: $75,000 connected equipment 4? For further product ratings, see Volume 1, Tab 2.1 Surge ProtectionNotes1 Order cover separately.2 With main lugs installed.3 Rainproof loadcenters are furnished with hub closure plates. For rainproof hubs, refer to Page V1-T1-25.4 For warranty details, visit www.eaton.com/surgetrap.AmpereRating TypeNumber of CircuitsLoadcenterCatalog Number 1Loadcenter Cover Catalog NumberCombination Surface225 Convertible 42 CHEC42N225L CHSUR8LF CHSUR8LS225 Convertible 2 42 CHEC42L225L CHSUR8LF CHSUR8LS200 Main breaker 42 CHEC42B200L CHSUR8LF CHSUR8LS225 Convertible 2 32 CHEC32L225K CHSUR8KF CHSUR8KS225 Convertible 32 CHEC32N225K CHSUR8KF CHSUR8KS225 Convertible 32 CHEC32N225R 3 — —200 Main breaker 32 CHEC32B200K CHSUR8KF CHSUR8KS150 Main breaker 32 CHEC32B150K CHSUR8KF CHSUR8KS100 Main breaker 32 CHEC32B100K CHSUR8KF CHSUR8KS125 Convertible 2 24 CHEC24L125E CHSUR8EF CHSUR8ES100 Main breaker 24 CHEC24B100E CHSUR8EF CHSUR8ESMaximum Main Ampere RatingCatalog Number25 kAIC 35 kAIC100 CSR2100N CSH2100N150 CSR2150N CSH2150N200 CSR2200N CSH2200N225 CSR2225N CSH2225NMaximum Main Ampere Rating Catalog Number125 CHL125N225 CHL225NVolume 1—Residential and Light Commercial CA08100002E—September 2014 www.eaton.com V1-T1-171111111111111111111111111111111.1Loadcenters and Circuit BreakersType CH Loadcenters and Circuit Breakers60-Circuit Plug-On Neutral Loadcenter Contents—CH Specialty ProductsDescription PageOverview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-2CH Specialty ProductsSpa Panels . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-14Surge Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-15Plug-On Neutral LoadcenterType CH Renovation Loadcenter . . . . . . . . . . . V1-T1-18Type CH Retrofit Interior Kits . . . . . . . . . . . . . . V1-T1-19CH Loadcenter Options and Accessories . . . . . . . V1-T1-22CH Circuit Breakers. . . . . . . . . . . . . . . . . . . . . . . . V1-T1-31Plug-On Neutral LoadcenterProduct DescriptionCode changes and higher safety standards are leading to more arc fault and ground fault circuit interrupter installations. Eaton offers a unique product solution that enables a direct connection of the breaker to the neutral bar, eliminating the need for wiring a pigtail. Features and Benefits? Time savings up to 25% per AFCI/GFCI installation? Eliminates nuisance tripping due to loose pigtail connections? Clean gutter space? Easier troubleshooting due to less wiring? Backed by a limited lifetime warrantyProduct SelectionMain Breaker Plug-On Neutral LoadcentersMain Lug Only/Convertible Plug-On Neutral Loadcenters—With Factory Installed Main LugsNotes1 Requires the use of Type CHT breakers.2 If 35 kAIC is required, use CSH breaker equivalent.MainBreakerTypeMainAmpereRatingMax.Number3/4-InchCircuitsMax.Numberof PolesEnclosureTypeBoxSizeWire SizeRangeCu/AlCatalogNumberCover CatalogNumber Combination SurfaceCSR 25 kAIC100 24 24 Indoor E #2–300 kcmil CH24BPN100E CH8EF CH8ES200 32 32 Indoor J #2–300 kcmil CH32BPN200J CH8JF CH8JS200 42 42 Indoor K #2–300 kcmil CH42BPN200K CH8KF CH8KS200 60 120 1 Indoor N #2–300 kcmil CH60BPN200N CH8NF —Max.AmpereRatingMax.Number3/4-InchPolesEnclosureTypeBoxSizeCatalogNumberWire SizeRangefor Main LugMainBreakerKit 2Wire SizeRangeFor MainBreakerCover CatalogNumber Combination Surface125 24 Indoor E CH24NLPN125E #6–300 kcmil CSR2100N #2–300 kcmil CH8NLEF CH8NLESCSR2125N225 32 Indoor J CH32NLPN225J #6–300 kcmil CSR2125N #2–300 kcmil CH8NLJF CH8NLJSCSR2200NCSR2100N225 42 Indoor K CH42NLPN225K #6–300 kcmil CSR2125N #2–300 kcmil CH8NLKF CH8NLKSCSR2150NCSR2200NV1-T1-18 Volume 1—Residential and Light Commercial CA08100002E—September 2014 www.eaton.com1111111111111111111111111111111.1 Loadcenters and Circuit BreakersType CH Loadcenters and Circuit BreakersRenovation Panel Contents—CH Specialty ProductsDescription PageOverview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-2CH Specialty ProductsSpa Panels. . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-14Surge Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-15Plug-On Neutral Loadcenter . . . . . . . . . . . . . . . V1-T1-17Type CH Renovation LoadcenterType CH Retrofit Interior Kits . . . . . . . . . . . . . . V1-T1-19CH Loadcenter Options and Accessories. . . . . . . . V1-T1-22CH Circuit Breakers . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-31Type CH Renovation LoadcenterProduct DescriptionEaton’s Renovation Loadcenter is designed for the service contractor. With the addition of a five-circuit terminal block factory mounted in the top left corner of the loadcenter, the service contractor can terminate short-circuit wires instead of having to use expensive wire nuts. Also, the Renovation Loadcenter incorporates a twin-stacked neutral design that places the neutral and ground terminations higher in the loadcenter. Both of these features were added without increasing any size from a standard loadcenter. These features will eliminate the need for wire nuts and make for a much neater installation. There is a provision to field mount a second five-circuit terminal block (RN5TB) in the top right corner of the loadcenter. Choose amongst Eaton’s Type CH breaker family for use in the Renovation Panel.Product SelectionSingle-Phase—Main Circuit Breaker Loadcenters 25 kAIC 1Single-Phase, Three-Wire—120/240 Vac—Stacked Split NeutralBranch Circuit Breakers (CH)See Pages V1-T1-2–V1-T1-13.Renovation LoadcenterNotes1 100 A main breaker is rated 10 kAIC.2 Combination style covers may be used in surface or flush applications.All main circuit breaker loadcenters are listed for use as service entrance equipment. Loadcenters are factory-bonded for service entrance applications. Remove bonding strap for separate neutral and ground bars for sub-feed applications.MainBreakerTypeMainAmpereRatingMax.Number3/4-Inch(19.1 mm)of PolesEnclosureTypeBoxSizeWire SizeRangeCu/Al60 ºC or 70 ºCfor MainBreakersLoadcenterCatalogNumberCover CatalogNumber 2Combination SurfaceCH 100 20 Indoor C #6–1/0 CH22B100CRN CH8CFF CH8CSCSR 150 32 Indoor J #2–300 kcmil CH32B150JRN CH8JF CH8JSCSR 200 32 Indoor J #2–300 kcmil CH32B200JRN CH8J CH8JSCSR 200 42 Indoor K #2–300 kcmil CH42B200KRN CH8KF CH8KSDescription Catalog NumberFive-circuit terminal block kitGround bar kits (two maximum per panel)RN5TB(See Page V1-T1-25)Volume 1—Residential and Light Commercial CA08100002E—September 2014 www.eaton.com V1-T1-191111111111111111111111111111111.1Loadcenters and Circuit BreakersType CH Loadcenters and Circuit BreakersType CH Retrofit Type CH Retrofit Interior Collar Adjustable Interior and Assembly with TrimType CH Retrofit Interior Contents—CH Specialty ProductsDescription PageOverview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-2CH Specialty ProductsSpa Panels . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-14Surge Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-15Plug-On Neutral Loadcenter . . . . . . . . . . . . . . . V1-T1-17Type CH Renovation Loadcenter . . . . . . . . . . . V1-T1-18Type CH Retrofit Interior KitsCH Loadcenter Options and Accessories . . . . . . . V1-T1-22CH Circuit Breakers . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-31Type CH Retrofit Interior KitsProduct DescriptionEaton’s unique Retrofit Interior allows the customer to cost-effectively and safely upgrade an electrical service without removing the existing enclosure from the wall.Application DescriptionThe Retrofit Interior is designed and tested specifically for renovating an outdated electrical panel in an apartment, a condominium or a single family home. These outdated panels are being recognized by local inspectors and other authorities as a possible hazard.Opportunities to Retrofit? Single- or three-phase? Main lug only or main breaker? Up to 42 circuits? Up to 225 A interiors, 400 A available upon request? Available with CH breakers (3/4-inch) with copper bus or BR breakers (1-inch) with aluminum bus? The minimum lifetime warranty for residential breakers shall be as follows:? Limited lifetime warranty on all CH branch breakers and loadcenters? Refer to Eaton for complete warranty detailsFeatures and BenefitsUpgrading Existing Electrical Infrastructure Is Simple? Replaces vintage brands that have hard to find, expensive replacement breakers? Safely upgrade to arc fault and ground fault breakers to meet current electrical codes? Maximizes number of circuits available with compact design? Eco-friendly in asbestos-filled environments? Exclusive designSave Time and Money Throughout the Installation? Uses existing panel box and wires? Eliminates expensive and time-consuming drywall/paint repair? Saves 2–3 hours of installation time compared to a complete panel changeout? Eliminates precise measurements with field-adjustable kitDetailed Product GuideFor questions about retrofit solutions, contact the Lincoln Flex Center at 800-330-6479 or flexcenterlincoln@eaton.com. Be sure to provide width, height and depth of panel.Standards and CertificationsMeets 2008/2011/2014 NEC wire bending requirements.V1-T1-20 Volume 1—Residential and Light Commercial CA08100002E—September 2014 www.eaton.com1111111111111111111111111111111.1 Loadcenters and Circuit BreakersType CH Loadcenters and Circuit BreakersCH Specialty Product SelectionTo select the retrofit kit:1. From the existing box size determine which retrofit groups are suitable (may be more than one).2. Use type of interior, number of phases, and type of main to find the selection chart.3. Select part number from chart (if main breaker, replace XXX with specific amp rating).4. Note that the overlap of the existing wall is the retro cover size minus the existing box size. If specific measurements are needed, communicate that you need a custom trim size.5. Contact the Lincoln Flex Center at 800-330-6479 for pricing, lead-times, and order entry instructions.How to Order:1. Measure the existing panel enclosure to determine appropriate kits for your project.2. Match the existing dimensions with the table below to obtain the correct catalog number.3. Order your retrofit kit from a local Eaton authorized distributor.Need assistance or can’t find retrofit to fit existing enclosure?Email or call Eaton’s Residential Flex Center at 1-800-330-6479 for all your retrofit needs. Go to www.eaton.com/eccn to locate an Eaton Certified Contractor.Retrofit Interior Kit SpecificationsFive recommended groups: existing box height determines retro group size. Approximate Dimensions in Inches (mm).Notes1 Catalog numbers shown with "_" at the end need one of the following suffixes to denote depth: J = 3.75–4.25K = 4.25–5.00L = 5.00–6.00Example: RBCH24B200J would signify an interior set with a depth range of 3.75 to 4.25 inches.2 ****Denotes characters in the catalog number that relate to overall cover size.Example: CRWCH6ML2620 would signify a cover 26.00 inches H x 20.00 inches W, or CRBCH24CS3324 would be 33.00 inches H x 24.00 inches W.3 Amperes for MB panels is maximum; catalog number will reflect actual amperage of breaker included.For UL applications, maximum cover sizes may apply.Existing Enclosure Parameters—Inches (mm)Catalog Number 1 Cover 2MinimumDepth MaximumDepthMinimumWidthMinimumHeight Phase Main Bus Amperes 3Spaces / CircuitsUL 67 ListedCH Retrofit Interiors and CoversRWCH6L125N CRWCH6ML**** 3.13 (79.5) 4.13 (104.9) 7.00 (177.8) 8.50 (215.9) Single MLO CH 125 6 NoRSCH10B125N CRWCH12ML**** 3.50 (88.9) 4.50 (114.3) 8.50 (215.9) 16.50 (419.1) Single MCB CH 125 10 NoRSCH12L125N CRWCH12ML**** 3.50 (88.9) 4.50 (114.3) 8.50 (215.9) 16.50 (419.1) Single MLO CH 125 12 NoRACH22B125J CRACH24ML**** 3.75 (95.3) 4.25 (108.0) 13.00 (330.2) 21.00 (533.4) Single MCB CH 125 22 NoRACH24L125J CRACH24ML**** 3.75 (95.3) 4.25 (108.0) 13.00 (330.2) 21.00 (533.4) Single MLO CH 125 24 NoRBCH24B200_ CRBCH24CS**** 3.75 (95.3) 6.00 (152.4) 13.00 (330.2) 29.00 (736.6) Single MCB CH 200 24 NoRBCH32L200_ CRBCH32ML**** 3.75 (95.3) 6.00 (152.4) 13.00 (330.2) 29.00 (736.6) Single MLO CH 200 32 NoRCCH32B200_ CRBCH32CS**** 3.75 (95.3) 6.00 (152.4) 13.00 (330.2) 34.00 (863.6) Single MCB CH 200 32 NoVolume 1—Residential and Light Commercial CA08100002E—September 2014 www.eaton.com V1-T1-211111111111111111111111111111111.1Loadcenters and Circuit BreakersType CH Loadcenters and Circuit BreakersComplete AssemblyNote: For complete assembly, interior and cover need to be ordered separately.Adjustable Interior? Factory installed ground and neutral bars positioned to accept existing wires? Field adjustable depth matches existing panel box? Adjustable height enables optional placement of the interior? Field bondable for service entrance optionsAdjustable InteriorStandard Trim and Collar? Standard trim matches new interior? New circuit directory for updated labeling? Oversized collar eliminates expensive wall/paint repairCollar and Assembly with TrimSingle-Phase—Main Lug Loadcenters, Non-MetallicSingle-Phase Three-Wire—120/240 Vac—Insulated/Bondable NeutralNotes1 Suitable for use as service equipment when not more than six main disconnecting means are provided and when not used as a lighting and appliance panelboard (see Article 408.34 of the NEC).2 This device has no main lugs. A Type BR or BD breaker is required to be backfed to supply power to branch breakers. This device is single-phase 120 Vac only. With the use of three Type BR breakers, there are two branch circuits available. With the use of three Type BD breakers, there are five branch circuits available.3 Includes GB4NM ground bar.MainAmpere RatingMaximum Number1-Inch (25.4 mm) EnclosureType Trim TypeBoxSizeWire Size Range Cu/Al 60 °C or 75 °C for Main LugsLoadcenterCatalog NumberSpaces Circuits40 1 2 4 Indoor Flush (no door) 2 2 TT120FLGNM 232 4 Indoor Surface (no door) 2 TT120SLGNM 2360 2 4 Indoor Flush (no door) 2 #14–2 2460FNM2 4 Indoor Surface (no door) 2 2460SNM2 4 Indoor Flush (no door) 2 2460FGNM 32 4 Indoor Surface (no door) 2 2460SGNM 32 4 Outdoor — — 2460RNM-A22460SNMV1-T1-22 Volume 1—Residential and Light Commercial CA08100002E—September 2014 www.eaton.com1111111111111111111111111111111.1 Loadcenters and Circuit BreakersType CH Loadcenters and Circuit BreakersCH Loadcenter Options and AccessoriesField Installation and PartsNote1 Must be purchased in multiples of ordering quantities indicated.DescriptionOrdering Quantity 1Catalog NumberSub-feed lug blocks—two-pole, 125 A, 3/4-inch (19.1 mm) spaces needed 1 CHSF2125Sub-feed lug blocks—three-pole, 125 A, 3/4-inch (19.1 mm) spaces needed 1 CHSF3125Neutral/ground lug—add-on neutral or ground lug 1 NL201 NL301 NL300Filler plates—3/4-inch (19.1 mm) space circuit breaker space 25 CHFPCSR main circuit breaker filler plate (with hardware) 1 CSRFPDoor lock—12–42 circuits, and 100–225 A 1 TDLSandlewood spray paint 1 SPCSWANSI-61 light gray touchup paint for outdoor loadcenters 1 SPC61Isolated neutral assembly (computer circuits) 1 BINACircuit directory—adhesive backed 10 TCDCover screws 25 LCCSCover replacement latch 14-5/16 inch (363.55 mm) wide loadcenters only 1 CHRLSCircuit marking strip (next to breakers) 10 CHMSCircuit identification label (preprinted breaker labels next to breakers) 25 CHBLSeries rated caution label 25 SRLBranch circuit numbering strip 20 CHNSBonding strap with screw 1 BSSUSECHSF2125CHSF3125CHFPTDLBINAVolume 1—Residential and Light Commercial CA08100002E—September 2014 www.eaton.com V1-T1-231111111111111111111111111111111.1Loadcenters and Circuit BreakersType CH Loadcenters and Circuit BreakersMechanical Interlock CoversCovers mechanically interlock two breakers. Type A covers interlock two CH breakers mounted across from one another. Type B covers interlock a main Type CSR breaker with a Type CH.Mechanical InterlocksMechanical Interlock Trim/Deadfront Catalog NumbersTypeFits LoadcenterCatalog Numbers Flush SurfaceA CH12L125B CH8BFM CH8BSMCH16L125BCH12L3125BCH14B100BCH20L125C CH8CFM CH8CSMCH24L125CCH18L3125CCH24L3125CCH22B100CCH22N100CCH24L150D CH8DFM CH8DSMCH32L150DCH24L3225DCH30L3150DCH42L225G CH8GFM CH8GSMCH42L3225GInner cover of Box B raintight — CH8BRMInner cover of Box C raintight — CH8CRMIndoorB CH24B150E CHEFM CHESMCH24B200ECH32B150J CH8JFM CH8JSMCH32B200JCH3242B200JCH32N200JCH32B225JCH42B200K CH8KFM CH8KSMCH42N200KCH42B225KOutoorB CH8B150RF CH3RDF7M —CH8B200RFCH8N200RFCH24B150RCH24B200RCH32B150R CH3RDF9M —CH32B200RCH32N200RCH32B225RCH42B200R CH3RDF10M —CH42N200RCH42B225RCH8BRM Type ACH8EFM Type BV1-T1-24 Volume 1—Residential and Light Commercial CA08100002E—September 2014 www.eaton.com1111111111111111111111111111111.1 Loadcenters and Circuit BreakersType CH Loadcenters and Circuit BreakersMechanical Interlocks, contiunedNote1 If vintage part number does not match exactly, the cover may not fit. Simple variations such as an “N” at the end of the part number contain minor design variations that will prevent our cover from working with that particular loadcenter.Mechanical Interlock Trim/Deadfront Catalog NumbersTypeFits LoadcenterCatalog Numbers Flush SurfaceNext Generation Power Center B CHPC32B150L CHPC8B32LFM —CHPC32B200LCHPC32N200LCHPC42B150L CHPC8B42LFM —CHPC42B200LCHPC42N200LCHPC32B125TR CH3RDF15M —CHPC32B150TRCHPC32B200TRCHPC32N200TRCHPC42B150TR CH3RDF16M —CHPC42B200TRCHPC42N200TRCHPC32B150TR CH3RDF17M —CHPC32B200TRCHPC42B200BR CH3RDF18M —Vintage 1CH20JJM200 CH7JJFREPLM —CH24JJM150CH30JJM150CH30JJM200CH30JJM150HCH3040JJMM200CH304JJM150CH304JJM200CH304JJM200HCH30KKM225 CH7KKFREPLM —CH40KKM200HCH40KKM225CH40KKM200HCH40KKM225HCH304KKM200CH304KKM200HCH304LLM225 CH7LLFREPLM —CH424LLM225HCH8BRM Type ACH8EFM Type BVolume 1—Residential and Light Commercial CA08100002E—September 2014 www.eaton.com V1-T1-251111111111111111111111111111111.1Loadcenters and Circuit BreakersType CH Loadcenters and Circuit BreakersField Installation Rainproof Conduit HubsGround Bar KitsGround Bar LegendGrounded “B” Phase Adapters Neutral Bar AccessoriesNotes1 Must be purchased in multiples of ordering quantities indicated.2 Distance between mounting holes is 1-3/4 inches (44.5 mm).3 For single- and three-phase 400 A loadcenters.4 Distance between mounting holes is 2-13/32 inches.5 Cannot be used in Safety Breaker Panels. Classic Plus Panels only.DescriptionConduit Size OrderingQuantity 1CatalogNumberInches (mm)Group 1—for use with 70, 100 and 125 A MLO and MCB loadcenters and circuit breaker enclosures 0.75 (19.1) 1 DS075H11.00 (25.4) 1 DS100H11.25 (31.8) 1 DS125H11.50 (38.1) 1 DS150H12.00 (50.8) 1 DS200H1Group 2—for use with 150, 200 and 225 A MLO and MCB loadcenters and circuit breaker enclosures 2.00 (50.8) 1 DS200H22.50 (63.5) 1 DS250H23.00 (76.2) 1 DS300H2Adapter kit—allows installing a Group 1 hub on devices arranged for Group 2 hubs — 1 DS900APGroup 1—small blank hub closure plate — 1 DS900CP1Group 2 —large blank hub closure plate — 1 DS900CP2Description (See Legend)Length OrderingQuantity 2Catalog NumberInches (mm)dssssds 2.54 (64.5) 1 GBK5 2dssssdsj 3.59 (91.2) 1 GBK520 2dssssdssssss 4.29 (109.0) 1 GBK10 2dssssdssssssj 5.34 (135.6) 1 GBK1020 24.61 (117.1) 1 GBK13 2dssssdssssssssss 5.69 (144.5) 1 GBK14 2dssssdssssssssssj 6.74 (171.2) 1 GBK1420 2dssssdsssssssssssssssss 8.14 (206.8) 1 GBK21 2dssssdsssssssssssssssssj 9.19 (233.4) 1 GBK2120 2ssssssssdssssssdsssssss 7.94 (201.7) 1 CH9GP21 34DS100H1GBK14f d f f f k f d f k f f fsjd= (3) #14–#10 Cu/Al or (1) #14–#4 Cu/Al= (1) #6–2/0 Cu/Al= (1) 1/0–14 or (3) #10–12 Cu/Al= (1) #14–1/0 Cu/Al or (3) #14–#10 Cu/Al= Mounting holef kMaximumAmperesThree-Phase LoadcenterTypes of PanelsKit CatalogNumber 5125 12–32 circuit main lug CHGRD1225 Main lug and CHH main breaker panels CHGRD2CC main CB panels CHGRD3DescriptionCatalogNumber 5Replacement neutral for all B and C type boxes CHN125CReplacement neutral for all D type boxes CHN125DReplacement neutral for all E, G, J, K and L type boxes CHN225LIsolated Neutral Assembly (computer circuits) BINAV1-T1-26 Volume 1—Residential and Light Commercial CA08100002E—September 2014 www.eaton.com1111111111111111111111111111111.1 Loadcenters and Circuit BreakersType CH Loadcenters and Circuit BreakersDecorator Cover Accessory? For easy use with CH loadcenters mounted in living space? Easily wallpapered or painted to match any decor? Loadcenter accessory—exclusively from EatonNow you see it … … Now you don’t.Decorator Cover Accessory 1Loadcenter Goof CollarsDon’t let an ugly drywall problem ruin a beautiful electrical installation.Eaton’s Goof Collar is designed to cover gaps between the finished drywall and loadcenter enclosure. This is often necessary when upgrading the electrical service and the drywall surrounding the panel is damaged. The collar allows 2 inches of overhang beyond the standard flush trim.Before AfterCH Goof CollarsBR Goof CollarsNote1 For goof collars not listed in the table, please contact the Lincoln Flex Center at 1-800-330-6479.Catalog NumberCorresponding Cover Existing CH Loadcenter Cover CH8BF CH8KDNBCH8CF CH8KDNCCH8DF/EF CH8KDNDCH8GF/JF CH8KDNJCH8KF CH8KDNKInches (mm) Catalog NumberHeight Width Loadcenter Cover Goof Collar21.00 (533.4) 19.00 (482.6) CH8BF CH8BFC192126.00 (660.4) 19.00 (482.6) CH8CF CH8CFC192634.00 (863.6) 19.00 (482.6) CH8DF CH8DFC1934CH8EFCHSUR8EF39.00 (990.6) 19.00 (482.6) CH8GF CH8JFC1939CH8JF42.00 (1066.8) 19.00 (482.6) CH8KF CH8KFC1942CHSUR8KF44.00 (1117.6) 19.00 (482.6) CH8LF CH8LFC1944CHSUR8LFInches (mm) Catalog NumberHeight Width BR Box Size Goof Collar21.00 (533.4) 19.00 (482.6) B1 BRB2GC231923.00 (584.2) 19.00 (482.6) B2 BRB1GC211925.00 (635.0) 19.00 (482.6) C1 BRC1GC251927.00 (685.8) 19.00 (482.6) C2 BRC2GC271931.00 (787.4) 19.00 (482.6) C4 BRC4GC311934.00 (863.6) 19.00 (482.6) D1 BRD1GC341938.00 (965.2) 19.00 (482.6) G1 BRG1GC381943.00 (1092.2) 19.00 (482.6) L1 BRL1G431948.00 (1219.2) 19.00 (482.6) L2 BRL2GC4819SCOTTHASPHOTOVolume 1—Residential and Light Commercial CA08100002E—September 2014 www.eaton.com V1-T1-271111111111111111111111111111111.1Loadcenters and Circuit BreakersType CH Loadcenters and Circuit BreakersDimensionsApproximate Dimensions in Inches (mm)Residential/Commercial/Unit Enclosure—Box SizesNote: Box sizes do not include covers/fronts.Residential LoadcentersCommercial LoadcentersTypes ECB and ECC Unit EnclosuresResidential Loadcenter KnockoutResidential NEMA Type 1 Indoor and NEMA Type 3R Outdoor Enclosures.Knockouts for Box Sizes 5, 6, 7, 5R, 6R, 7RKnockout PositionsBox Size Height Width DepthNEMA Type 1 Indoor5 9.50 (241.3) 4.50 (114.3) 3.13 (79.4)6 11.38 (288.9) 6.88 (174.6) 3.39 (86.1)7 13.00 (330.2) 11.00 (279.4) 3.69 (93.7)B 16.75 (425.5) 14.31 (363.5) 3.88 (98.4)C 21.00 (533.4) 14.31 (363.5) 3.88 (98.4)D 29.13 (739.8) 14.31 (363.5) 3.88 (98.4)E 29.13 (739.8) 14.31 (363.5) 3.88 (98.4)G 34.13 (866.8) 14.31 (363.5) 3.88 (98.4)J 34.13 (866.8) 14.31 (363.5) 3.88 (98.4)K 37.00 (939.8) 14.31 (363.5) 3.88 (98.4)L 39.00 (990.6) 14.31 (363.5) 3.88 (98.4)N 45.00 (1143.0) 14.31 (363.5) 3.88 (98.4)NEMA Type 3R Outdoor5R 9.50 (241.3) 4.50 (114.3) 3.13 (79.4)6R 11.75 (298.5) 6.50 (165.1) 4.50 (114.3)7R 13.00 (330.2) 11.00 (279.4) 3.69 (93.7)B 16.75 (425.5) 14.31 (363.5) 5.19 (131.8)C 21.00 (533.4) 14.31 (363.5) 5.19 (131.8)D 29.13 (739.8) 14.31 (363.5) 5.19 (131.8)E 29.13 (739.8) 14.31 (363.5) 5.19 (131.8)G 34.13 (866.8) 14.31 (363.5) 5.19 (131.8)J 34.13 (866.8) 14.31 (363.5) 5.19 (131.8)K 37.00 (939.8) 14.31 (363.5) 5.19 (131.8)L 39.00 (990.6) 14.31 (363.5) 5.19 (131.8)Box Size Height Width DepthNEMA Type 1 IndoorP 54.38 (1381.1) 21.00 (533.4) 6.00 (152.4)PM 62.63 (1590.7) 21.00 (533.4) 6.00 (152.4)Height Width DepthNEMA Type 1 Indoor23.25 (590.6) 8.88 (225.4) 4.50 (114.3)NEMA Type 3R Outdoor23.69 (601.7) 9.31 (236.5) 5.44 (138.1)Code DiameterA 0.50 (12.7) — — —B 0.50 (12.7) 0.75 (19.1) — —C 0.50 (12.7) 0.75 (19.1) 1.00 (25.4) —D 0.50 (12.7) 0.75 (19.1) 1.00 (25.4) 1.25 (31.8)E 0.75 (19.1) 1.00 (25.4) 1.25 (31.8) —F 0.75 (19.1) 1.00 (25.4) 1.25 (31.8) 1.50 (38.1)G 1.00 (25.4) 1.25 (31.8) 1.50 (38.1) —H 1.00 (25.4) 1.25 (31.8) 1.50 (38.1) 2.00 (50.8)I 1.25 (31.8) 1.50 (38.1) 2.00 (50.8) —Box 6RBox 7 Box 7RBox 5 Box 5RBox 6AAD D DFHubAABABBCCF FFFABFFHABABHFB BBHHubD DAAAAAAAAAAA AAAB B BA B BBBBBC CCCCB CGGGGG GFAAA AAAA B BB CCGG GFHubAAAAAAD D DDFFV1-T1-28 Volume 1—Residential and Light Commercial CA08100002E—September 2014 www.eaton.com1111111111111111111111111111111.1 Loadcenters and Circuit BreakersType CH Loadcenters and Circuit BreakersApproximate Dimensions in Inches (mm)Residential and Commercial Loadcenter Knockout Residential NEMA Type 1 indoor and NEMA Type 3R outdoor enclosures.Knockouts for Box Sizes 8, 8R, P, PM, B, C, D, E, G, J, K, L, N and Outdoor Boxes 12–60 Circuits Knockout DiagramType ECB and ECC Unit Enclosure KnockoutNEMA Type 1—IndoorNEMA Type 3R—OutdoorCode Diametera 0.75 (19.1) — — — —b 0.50 (12.7) 0.75 (19.1) — — —c 0.50 (12.7) — — — —d 1.00 (25.4) 1.25 (31.8) 1.50 (38.1) 2.00 (50.8) 2.50 (63.5)e 1.25 (31.8) 1.50 (38.1) 2.00 (50.8) 2.50 (63.5) —f 0.75 (19.1) 1.25 (31.8) 1.50 (38.1) 2.00 (50.8) —g 0.50 (12.7) 0.75 (19.1) 1.00 (25.4) — —h 1.50 (38.1) 2.00 (50.8) 2.50 (63.5) — —i 0.50 (12.7) 0.75 (19.1) 1.00 (25.4) 1.25 (31.8) 1.50 (38.1)j 1.00 (25.4) 1.25 (31.8) 1.50 (38.1) — —k 1.25 (31.8) 1.50 (38.1) 2.00 (50.8) — —m 0.75 (19.1) 1.00 (25.4) 1.25 (31.8) 1.50 (38.1) 2.00 (50.8)n 0.75 (19.1) 1.00 (25.4) 1.25 (31.8) 1.50 (38.1) —p 2.00 (50.8) 2.50 (63.5) — — —e e e edcccc cbbicccc cbgbcc c caFlushTrim3/4chbbegbbcccgebegbbcccgee eeeg gdc ccccbbic ccccbgbcdcccc cbbicccc cbgbc0.45 Dia.0.45 Dia.0.45 Dia.0.45 Dia.begbbccgee eeeg gbccbegbbcccgebcdc ccccbbic ccccbgbcdcccc cbbicccc cbgbc0.45 Dia.0.45 Dia.Box P, PMOutdoor Boxes12–42 Circuits 225 A MaximumBox B Box C, D, E, G, J, K, L, N0.45 Dia.0.45 Dia.0.45 Dia.0.45 Dia.Code DiameterNEMA Type 1 Indoor (Flush and Surface Trims)A 0.50 (12.7) — — — —B 1.25 (31.8) 1.50 (38.1) 1.75 (44.5) 2.00 (50.8) 2.50 (63.5)NEMA Type 3R OutdoorA 0.50 (12.7) — — — —B 1.25 (31.8) 1.50 (38.1) 1.75 (44.5) 2.00 (50.8) 2.50 (63.5)BBBBAABBBBBB AB BHUBVolume 1—Residential and Light Commercial CA08100002E—September 2014 www.eaton.com V1-T1-291111111111111111111111111111111.1Loadcenters and Circuit BreakersType CH Loadcenters and Circuit BreakersTechnical Data and SpecificationsGeneralA. The Contractor shall furnish and install loadcenters incorporating circuit breakers of the number, rating and type as specified herein and as shown on the contract drawings.B. The loadcenter and all components shall be designed, manufactured and tested in accordance with the latest applicable standards of UL and NEMA including:1. UL 67—standards for panelboards2. UL 50—standards for cabinets and boxes3. UL 489—standards for molded case circuit breakers4. Federal Spec Classification W-C 3755. UL 1699—all fault interruptingQualificationsA. The manufacturer of the loadcenter shall be the manufacturer of the circuit breaker within the load center. All breakers shall be full size.B. For the equipment specified herein, the manufacturer shall be ISO® 9000 certified.C. The manufacturer of this equipment shall have produced similar electrical equipment for a minimum period of seven (7) years.ManufacturersA. EatonRatingsA. Loadcenters shall be rated for 240 Vac and shall have short-circuit ratings as shown on the drawings or as herein scheduled, but not less than 10,000 amperes rms symmetrical.B. Breakers shall be full size and a minimum of 125 A frame. Breakers 10 –125 A trip size shall take up the same pole spacing.C. Loadcenters shall be labeled with a UL short-circuit rating. When series ratings are applied with integral or remote devices, a label shall be provided. Series ratings shall cover all trip ratings of installed frames. It shall state the conditions of the UL series ratings including:1. Size and type of upstream device.2. Branch devices that can be used.3. UL series short-circuit rating.ConstructionA. All interiors, with the exception of the branch circuit breakers shall be completely factory assembled with main breakers, main lugs or no main device.B. Interiors shall be so designed that circuit breakers can be replaced without disturbing adjacent units and without removing the main bus connectors and shall be so designed that circuits may be changed without machining, drilling or tapping.C. Physical means must be provided to prevent the installation of more overcurrent devices than that number for which the enclosure was designed. Full size breakers are required.BusA. Busbars for the main and cross connectors shall be of silver flash plated copper construction in accordance with UL standards. Bussing shall be braced to 65 kAIC.B. Neutral bussing shall have a suitable lug for each outgoing feeder requiring a neutral connection of same ampacity as branch.Wiring/TerminationA. All wire connectors and terminals shall be of the anti-turn solderless type and suitable for copper or aluminum wire of the sizes indicated. All connectors shall meet the “Requirements for Wire Connectors and Soldering Lugs” UL 486B.B. All loadcenters where marked shall be suitable for use with 60/75 °C rated wire.Circuit BreakersA. Circuit breakers shall be molded case type, 3/4-inch (19.1 mm) wide per pole. Multipole circuit breakers shall be of a stack pole design to provide electrical phase isolation and have an internal common trip.B. Each pole of the circuit breaker will have inverse time delay overload and instantaneous short-circuit protection by means of both thermal and magnetic sensors. Circuit breakers shall be quick-make/quick-break.C. The circuit breaker calibration shall not be affected by environmental changes in relative humidity. Breakers shall be calibrated after assembly.D. All circuit breakers shall be operated by a toggle-type handle and multipole circuit breakers shall have an internal common trip mechanism. The circuit breakers shall incorporate trip mechanisms that are mechanically trip-free from the handle. The handle position shall provide good visual trip indication.E. Contacts shall be of non-welding silver alloy.F. All branch breaker handles shall be of a different color than the case of the breaker.G. All terminals shall be listed for use with copper or aluminum conductors. Terminals shall be of the box lug design. The terminals shall meet UL 486B requirements and shall be suitable for use with either 60° or 75 °C wire.H. Breakers shall be SWD rated and/or HACR rated as required.I. Arc fault interrupting circuit breakers, (AFC), shall be provided on all 15 and 20 A single-phase 120/240 Vac circuits except those indicated as remote controlled breakers. AFI breakers shall be “Classified for mitigating the effects of arcing faults,” or conforming to UL Standard 1699 and as defined by per Article 210.12 Section A of the NEC Code.V1-T1-30 Volume 1—Residential and Light Commercial CA08100002E—September 2014 www.eaton.com1111111111111111111111111111111.1 Loadcenters and Circuit BreakersType CH Loadcenters and Circuit BreakersEnclosuresA. Loadcenters shall have NEMA 1 general purpose or NEMA 3R rainproof enclosures as indicated on the drawings and shall be surface or flush mounted except where noted.B. For indoor applications, enclosures shall be rated NEMA 1. Enclosures shall be manufactured from cold-rolled code-gauge sheet steel having multiple knockouts and painted per paint specification. For outdoor applications, enclosures shall be rated NEMA 3R. Enclosures shall be manufactured from galvanized steel which shall be painted per the painted as specified. Enclosures shall be of sufficient size to meet or exceed NEC wire bending space.C. The cover shall have an easy adjustment feature for flush applications.D. Boxes shall be factory assembled into a single rigid structure.E. Provide circuit breaker marking labels and directories.FinishA. Boxes and trims shall be finished with a high scratch-resistant aesthetically pleasing finish. The finish shall be polyurethane coating electrostatically applied to a thickness of 1.8 to2 mils.All loadcenters shall be provided with provisions for accepting a paintable or wall paperable decorator accessory cover. Where loadcenters are installed in living areas, provide manufacturer designed and tested decorator cover kits.Volume 1—Residential and Light Commercial CA08100002E—September 2014 www.eaton.com V1-T1-311111111111111111111111111111111.1Loadcenters and Circuit BreakersType CH Loadcenters and Circuit BreakersPlug-On Circuit Breakers ContentsDescription PageOverview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-2CH Specialty Products. . . . . . . . . . . . . . . . . . . . . . V1-T1-14CH Loadcenter Options and Accessories . . . . . . . V1-T1-22CH Circuit BreakersProduct Selection . . . . . . . . . . . . . . . . . . . . . . . V1-T1-32Options and Accessories . . . . . . . . . . . . . . . . . V1-T1-38Technical Data and Specifications . . . . . . . . . . V1-T1-40Wiring Diagrams. . . . . . . . . . . . . . . . . . . . . . . . V1-T1-40CH Circuit BreakersProduct DescriptionQuick-make, quick-break switch mechanism combined with inverse time element tripping operation and trip- free handle design. Type CH circuit breakers trip to the OFF position, eliminating nuisance callbacks. The CHF family also includes a trip flag to differentiate between a trip and the breaker being turned off. The thermal-magnetic trip curve avoids nuisance tripping on mild overloads while reacting almost instantaneously to severe short-circuit conditions. Multipole breakers have internal common trip connection to operate all poles simultaneously. Handles are marked with ON-OFF indication and ampere rating of the breaker. Special Application Plug-On Circuit Breakers—Type CH 10 kAIC 120 Vac and 120/240 VacBranch Feeder Type Arc Fault Circuit BreakersA branch feeder type arc fault circuit interrupter is a device intended to mitigate high current arcing faults in the complete circuit, including connected cords. High current arcing faults can occur from line to neutral or line to ground. These arcing faults are in parallel with the load and produce the most energy of all arcing faults.The branch feeder type AFCI is required in the 1999 and 2002 National Electrical Code.The Combination Type AFCI is required in all subsequent editions of the National Electrical Code.Combination Type Arc Fault Circuit BreakersA combination type arc fault circuit interrupter is a device that offers mitigation of high current arcing faults in the complete circuit, including connected cords. In addition it provides direct detection of persistent low current arcing faults down to 5 amps with associated mitigation of fire hazards in the cords connected to the outlets. High current arcing faults can occur from line to neutral or line to ground. These arcing faults are in parallel with the load and produce the most energy of all arcing faults. The current level of low current arcing faults is limited by the load.Ground Fault Circuit Breakers—Ground Fault Application NotesSingle-pole Type CHGFIs are designed for use in two-wire, 120 Vac circuits. The diagram on Page V1-T1-40 shows a typical wiring configuration.Two-pole Type CHGFIs are designed for use in three-wire, 120/240 Vac circuits, 120 Vac multiwire circuits employing common, neutral and two-wire, 240 Vac circuits obtained from a 120/240 Vac source.Diagrams on Page V1-T1-40 illustrate typical wiring configurations for 120/240 Vac multiwire circuits.The diagram on Page V1-T1-40 depicts a 240 Vac, two-wire circuit. Note the “panel neutral” conductor connects to the neutral bar, even though the neutral is not included in the load circuit. This connection is necessary to supply a 120 Vac power source to the ground fault sensing circuit.The figures are shown with a 120/240 Vac, single-phase, three-wire power source, but are also applicable to a 120/208 Vac, three-phase,four-wire power supply. For all figures, the electrical operation of the Type CHGFI is not affected by the equipment ground.FeaturesLatch SpringOver-CenterToggle SpringLatch LeverMagneticArmatureCurrent Bi-MetalLugScrewLoad TerminalMagnetic Pole PieceContact Line Contact ClipV1-T1-32 Volume 1—Residential and Light Commercial CA08100002E—September 2014 www.eaton.com1111111111111111111111111111111.1 Loadcenters and Circuit BreakersType CH Loadcenters and Circuit BreakersProduct Selection10 kAIC, 120 Vac, 120/240 Vac and 240 VacType CH Breakers, 3/4-Inch (19.1 mm) per Pole 120, 120/240 or 240 Vac, 10 kAICCHF Breakers with Mechanical Trip Flag Notes1 For single- and two-pole breakers.2 Solid and stranded wire can be used together.3 For three-pole breakers.4 Single-pole 60–70 A, two-pole 80–125 A, three-pole 40–100 A.5 Single-pole 40–50 A, two-pole 40–70 A.6 Two-pole 150 A.7 Switching duty rated.8 HACR rated.For factory-installed options, refer to Page V1-T1-39.AmpereRatingWire Size Range Cu/Al 60 °C or 75 °CCatalog NumberSingle-Pole 120/240 Vac Requires One3/4-Inch (19.1 mm) Space10 per Shelf CartonTwo-Pole 120/240 Vac Common Trip Requires Two 3/4-Inch (19.1 mm) Spaces5 per Shelf CartonThree-Pole 240 Vac Common Trip Requires Three 3/4-Inch (19.1 mm) Spaces5 per Shelf Carton10 (1) #14–8 1(2) #14–10 12(1) #14–6 3CH110 CH210 CH31015 CH115 78 CH215 8 CH315 820 CH120 78 CH220 8 CH320 825 CH125 8 CH225 8 CH325 830 CH130 8 CH230 8 CH330 835 #14–2 1#14–6 3CH135 8 CH235 8 CH335 840 #10–1/0 4#14–2 5#3/0 6CH140 8 CH240 8 CH340 845 CH145 8 CH245 8 CH345 850 CH150 8 CH250 8 CH350 860 CH160 CH260 CH36070 CH170 CH270 CH37080 — CH280 CH308090 — CH290 CH3090100 — CH2100 CH3100110 — CH2110 —125 — CH2125 —AmpereRatingWire Size Range Cu/Al 60 °C or 75 °CCatalog NumberSingle-Pole 120/240 Vac Requires One3/4-Inch (19.1 mm) Space10 per Shelf CartonTwo-Pole 120/240 Vac Common Trip Requires Two 3/4-Inch (19.1 mm) Spaces5 per Shelf Carton10 (1) #14–8 1(2) #14–10 12CHF110 CHF21015 CHF115 78 CHF215 820 CHF120 78 CHF220 825 CHF125 8 CHF225 830 CHF130 8 CHF230 835 #14–2 1 CHF135 8 CHF235 840 #10–1/0 4#14–2 5CHF140 8 CHF240 845 CHF145 8 CHF245 850 CHF150 8 CHF250 8Type CH Plug-On Circuit BreakersType CH Plug-On Circuit BreakersVolume 1—Residential and Light Commercial CA08100002E—September 2014 www.eaton.com V1-T1-331111111111111111111111111111111.1Loadcenters and Circuit BreakersType CH Loadcenters and Circuit BreakersPlug-On Branch Feeder Type Arc Fault Circuit Breakers, Type CH 10 kAIC, 120 Vac and 120/240 VacCombination Type CH AFCI 3/4-Inch (19.1 mm) Wide Circuit BreakersBranch Type CH AFCI 3/4-Inch (19.1 mm) Wide FIRE-GUARD® Circuit BreakersPlug-On Combination Type Arc Fault Circuit Breakers and Ground Fault, Type CH 10 kAIC, 120 Vac and 120/240 Vac 4Combination Type CH AFCI 3/4-Inch (19.1 mm) and CHGFCI Circuit BreakersNotes1 Clamshell packaging available with CS modification code on the end of catalog number.2 Common trip refers to two-pole 240 V load application sourced by 120/240 Vac (see diagram on Page V1-T1-40).3 Independent trip refers to two-pole multi-wire, home run or shared neutral circuits (see diagrams on Page V1-T1-40).4 Requires plug-on neutral loadcenter. Poles Ampere Rating Catalog NumberStandard PigtailSingle-pole10 kAIC15 CHFCAF11520 CHFCAF120Two-pole10 kAIC15 CHCAF21520 CHCAF220Poles Ampere Rating Configuration Catalog NumberSingle-pole10 kAIC15 AFCI CH115AF 120 AFCI CH120AF 1Two-pole10 kAIC 2315 AFCI common trip CH215AF20 AFCI common trip CH220AFPoles Ampere Rating Configuration Catalog NumberSingle-pole10 kAIC15 AFCI plug-on neutral CHFCAF115PN20 AFCI plug-on neutral CHFCAF120PN15 GFCI plug-on neutral CHFGF115PN20 CHFGF120PN25 CHFGF125PN30 CHFGF130PNType CH AFCI Single-Pole Circuit BreakerType CH AFCI Single-Pole Circuit BreakerType CH AFCI Single-Pole PON Combo Circuit BreakerV1-T1-34 Volume 1—Residential and Light Commercial CA08100002E—September 2014 www.eaton.com1111111111111111111111111111111.1 Loadcenters and Circuit BreakersType CH Loadcenters and Circuit BreakersPlug-On Ground Fault Circuit Breakers, Type CH 10 kAIC, 120 Vac and 120/240 VacType CH Ground Fault Circuit Breakers (5 Milliampere) 3/4-Inch (19.1 mm) per Pole 120 Vac or 120/240 Vac,10 kAICType CH Ground Fault Equipment Protectors (30 Milliampere) 3/4-Inch (19.1 mm) per Pole 120 Vac or 120/240 Vac, 10 kAICType CH Switching Neutral Breakers—10 kAIC, 120 Vac and 120/240 VacUsed to open the neutral along power line(s) for applications of gas pumps.3/4-Inch (19.1 mm) per Pole 120/240 or 240 Vac, 10 kAICNotes1 60 A breaker listed for 75 °C Cu wire only.2 For circuit breakers with shunt trip, add ST suffix. Shunt trip requires one additional pole space. 3 Switching duty rated.Ampere RatingWire Size Range Cu/Al 60 °C or 75 °C 1Catalog Number—1 per Shelf CartonSingle-Pole 120 Vac Requires One 3/4-Inch (19.1 mm) SpaceTwo-Pole 120/240 Vac Common Trip Requires Two 3/4-Inch (19.1 mm) Spaces15 #14–6 CHFGF115 CH215GF20 #14–6 CHFGF120 CH220GF25 #14–6 CHFGF125 CH225GF30 #14–6 CHFGF130 CH230GF35 #14–6 — CH235GF40 #14–6 — CH240GF45 #14–6 — CH245GF50 #14–6 — CH250GF60 #14–6 1 — CH260GFAmpere RatingWire Size Range Cu/Al 60 °C or 75 °C 1Catalog Number—1 per Shelf CartonSingle-Pole 120 Vac Requires One 3/4-Inch (19.1 mm) SpaceTwo-Pole 120/240 Vac Common Trip Requires Two 3/4-Inch (19.1 mm) Spaces15 #14–6 CHFEP115 CH215EPD20 #14–6 CHFEP120 CH220EPD25 #14–6 CHFEP125 —30 #14–6 CHFEP130 CH230EPD40 #14–6 — CH240EPD50 #14–6 — CH250EPD60 #14–6 1 — CH260EPDAmpereRatingWire Size Range Cu/Al 60 °C or 75 °CCatalog Number—1 per Shelf CartonTwo-Pole 120 Vac Common Trip Requires Two 3/4-Inch (19.1 mm) SpacesThree-Pole 120/240 VacCommon Trip Requires Three 3/4-Inch (19.1 mm) Spaces15 #14–8 CH215SW 2 CH315SW 320 #14–8 CH220SW 2 CH320SW 330 #14–8 CH230SW 2 CH330SW 340 #14–8 CH240SW 2 CH340SW 350 #14–8 CH250SW 2 CH350SW 3Type CH Single-PoleType CH Two-PoleCH220SWNeutral InNeutral Out(Hot leg)Neutral InNeutral OutPhasePhaseVolume 1—Residential and Light Commercial CA08100002E—September 2014 www.eaton.com V1-T1-351111111111111111111111111111111.1Loadcenters and Circuit BreakersType CH Loadcenters and Circuit BreakersType CH-HID Circuit Breakers—10 kAIC, 120 Vac, 120/240 and 240 VacSuitable for use in circuits for fluorescent and high intensity discharge lighting. Also suitable for HACR applications.3/4-Inch (19.1 mm) per Pole 120 Vac, 120/240 and 240 Vac, 10 kAIC Type CHT Twin 10 kAIC, 120/240 Vac, Universal CTL and Non-CTL Plug-On Circuit BreakersSuitable for CTL and Non-CTL CH loadcenters. Twin (CTL) 3/4-Inch (19.1 mm) per Pole 120 Vac Class CTL 10 kAICNotes1 CH215HID is rated for 120/240 V.2 Switching duty rated.3 HACR rated.AmpereRatingWire Size RangeCu/Al 60 ºC or 75 ºCSingle-Pole 120/240 Vac Requires One 3/4-Inch (19.1 mm) SpaceTwo-Pole 240 VacCommon Trip Requires Two 3/4-Inch (19.1 mm) SpacesThree-Pole 240 VacCommon Trip Requires Three 3/4-Inch (19.1 mm) Spaces10 per Shelf CartonCatalog Number5 per Shelf CartonCatalog Number5 per Shelf CartonCatalog Number15 #14–8 CH115HID CH215HID 1 CH315HID20 #14–8 CH120HID CH220HID CH320HID30 #14–8 CH130HID CH230HID CH330HIDAmpereRatingWire Size Range Cu/Al 60 °C or 75 °CSingle-Pole Requires One 3/4-Inch (19.1 mm) Space10 per Shelf CartonCatalog Number15–15 #14–8 CHT1515 2315–20 #14–8 CHT1520 2320–20 #14–8 CHT2020 23Type CH and CHT Circuit Breakers Mounted in Twin Breaker Panel120/240 Vac120/240 VacV1-T1-36 Volume 1—Residential and Light Commercial CA08100002E—September 2014 www.eaton.com1111111111111111111111111111111.1 Loadcenters and Circuit BreakersType CH Loadcenters and Circuit BreakersType CHP Commercial Breakers—10 kAIC, 120 Vac, 120/240 Vac and 240 VacNote: CHP breakers feature on-off and trip positions for commercial applications.3/4-Inch (19.1 mm) per Pole 120, 120/240 or 240 Vac, 10 kAICType CHP-GFCI Circuit Breakers—10 kAIC, 120 Vac and 120/240 VacNote: CHP breakers offer on-off and trip positions for commercial applications.5 Milliampere—3/4-Inch (19.1 mm) per Pole 120 V and 120/240 Vac, 10 kAICNotes1 For single- and two-pole breakers.2 Solid and stranded wire can be used together.3 For three-pole breakers.4 Single-pole 60–70 A, two-pole 80–125 A, three-pole 40–100 A.5 Single-pole 40–50 A, two-pole 40–70 A.6 Switching duty rated.7 HACR rated.CHP breakers offer on-off and trip positions for commercial applications.AmpereRatingWire Size RangeCu/Al 60 °C or 75 °CSingle-Pole 120/240 VacRequires One 3/4-Inch (19.1 mm) SpaceTwo-Pole 120/240 VacCommon TripRequires Two 3/4-Inch (19.1 mm) SpacesThree-Pole 240 VacCommon TripRequires Three 3/4-Inch (19.1 mm) Spaces10 per Shelf CartonCatalog Number5 per Shelf CartonCatalog Number5 per Shelf CartonCatalog Number10 (1) #14–8 1(2) #14–10 12(1) #14–6 3CHP110 CHP210 CHP31015 CHP115 67 CHP215 7 CHP315 720 CHP120 67 CHP220 7 CHP320 725 CHP125 7 CHP225 7 CHP325 730 CHP130 7 CHP230 7 CHP330 735 #14–2 1#14–6 3CHP135 7 CHP235 7 CHP335 740 #10–1/0 4#14–2 5CHP140 7 CHP240 7 CHP340 745 CHP145 7 CHP245 7 CHP345 750 CHP150 7 CHP250 7 CHP350 760 CHP160 7 CHP260 7 CHP360 770 CHP170 CHP270 CHP37080 — CHP280 —90 — CHP290 —100 — CHP2100 CHP3100110 — CHP2110 —125 — CHP2125 —AmpereRatingWire Size RangeCu/Al 60 °C or 75 °CSingle-Pole 120 Vac Requires One 3/4-Inch (19.1 mm) Space1 per Individual CartonCatalog Number15 #14–6 CHP115GF20 #14–6 CHP120GF30 #14–6 CHP130GFVolume 1—Residential and Light Commercial CA08100002E—September 2014 www.eaton.com V1-T1-371111111111111111111111111111111.1Loadcenters and Circuit BreakersType CH Loadcenters and Circuit BreakersType CHP Neutral Switching Breakers—10 kAIC, 120 Vac and 120/240 VacUsed to open the neutral along power line(s) for applications of gas pumps.3/4-Inch (19.1 mm) per Pole 120 or 120/240 Vac, 10 kAICType CH-M50 High Ambient Breaker3/4-Inch (19.1 mm) per Pole 120 or 120/240 Vac, 10 kAICType CH-HM and CHP-HM High Magnetic Breakers3/4-Inch (19.1 mm) per Pole 120 or 120/240 Vac, 10 kAICNote1 For circuit breakers with shunt trip, add ST suffix. Shunt trip requires one additional pole space, obtain pricing from Page V1-T1-39.AmpereRatingWire Size RangeCu/Al 60 °C or 75 °CTwo-Pole 120 Vac Common TripRequires Two 3/4-Inch (19.1 mm) SpacesThree-Pole 120/240 Vac Common TripRequires Three 3/4-Inch (19.1 mm) Spaces1 per Shelf CartonCatalog Number1 per Shelf CartonCatalog Number15 #14–8 CHP215SW 1 CHP315SW 120 #14–8 CHP220SW 1 CHP320SW 1AmpereRatingWire Size RangeCu/Al 60 °C or 75 °CSingle-Pole 120/240 Vac Requires One 3/4-Inch (19.1 mm) SpaceTwo-Pole 120/240 Vac Common Trip Requires Two 3/4-Inch (19.1 mm) Spaces10 per Shelf CartonCatalog Number5 per Shelf CartonCatalog Number15 (1) #14–8(2) #14–10CH115M50 CH215M5020 CH120M50 CH220M5025 CH125M50 CH225M5030 CH130M50 CH230M5035 CH135M50 CH235M5040 CH140M50 CH240M5045 CH145M50 CH245M5050 CH150M50 CH250M5060 — CH260M5070 — CH270M50AmpereRatingWire Size RangeCu/Al 60 °C or 75 °CSingle-Pole 120/240 Vac Requires One 3/4-Inch (19.1 mm) SpaceTwo-Pole 120/240 Vac Common Trip Requires Two 3/4-Inch (19.1 mm) Spaces10 per Shelf CartonCatalog Number5 per Shelf CartonCatalog Number15 (1) #14–8(2) #14–10CH115HM CH215HM20 CH120HM CH220HM15 (1) #14–8(2) #14–10CHP115HM CHP215HM20 CHP120HM CHP220HMNeutral InNeutral Out(Hot leg)Neutral InNeutral OutPhasePhaseV1-T1-38 Volume 1—Residential and Light Commercial CA08100002E—September 2014 www.eaton.com1111111111111111111111111111111.1 Loadcenters and Circuit BreakersType CH Loadcenters and Circuit BreakersOptions and AccessoriesField Installation Kits and PartsNotes1 Must be purchased in multiples of ordering quantities indicated.2 Handle ties: typically used to join two similar independent single-pole breakers to form a two-pole noncommon trip breaker.3 Handle lockoffs: devices that use a padlock to lock the circuit breaker’s handle in the ON or OFF position.4 Requires one additional pole space.5 Escutcheon mounted: device mounted semipermanently to the face of the circuit breaker and secured by the loadcenter deadfront.6 Screw mounted: device permanently mounted to the face of the circuit breaker by the use of a non-removable screw.7 Handle lockdogs: devices that are used to secure a circuit breaker’s handle in the ON or OFF position. Handle lockdogs are not padlockable devices.8 Handle mounted: device mounted above or below handle using spring pressure.9 Hold-down kits: devices used to secure the circuit breaker to the loadcenter for back-feed main application. See NEC Article 384.16(g).DescriptionOrdering Quantity 1Catalog NumberHandle Ties 2Handle tie bar for physically joining the handles of two adjacent single-pole Type CH circuit breakers (molded plastic handle cover) 25 CHHTHandle Lockoffs 34Padlockable device for locking the handle of single-, two- or three-pole Type CH circuit breakers (escutcheon mounted) 5 1 CHPLPadlockable device for locking the handle of a single-, two- or three-pole Type CHGFI circuit breaker (escutcheon mounted) 5 1 CHPLGFPadlockable device for locking the handle of main circuit breaker Types CC and CCH into the ON or OFF position.(screw mounted) 6 1 CCPLPadlockable device for locking the handle of main breaker Types BW and CSR into the ON or OFF position (escutcheon mounted) 5 1 MCBPLHandle Lockdogs 47Device used to secure handle in ON or OFF position for single-pole Type CH circuit breakers (handle mounted) 8 10 CHLOHold-Down Kits 9Hold-down retainer kit for single-, two-, three-pole Type CH circuit breakers. For 6–24 circuit 125 A single- and three-phase, 12–42 circuit single-phase 225 A and 24–42 circuit three-phase 225 A MLO Type CH loadcenters1 CH125RBHold-down retainer kit for single-, two-, three-pole Type CH circuit breakers for 2–4 circuit MLO CH loadcenters. 1 CH125RB24Mounting BasesMounting base for two-pole Type CH circuit breaker—70 A maximum 1 CH9MB270Main Breaker Lug KitsTypes CC and CCH main breaker lug kit (2) 300 kcmil 1 CCL300Type CSR main breaker lug kit (2) 300 kcmil 1 MCBL300Mechanical InterlockType CH for two-, three- and four-pole breakers 10 CHMLCHHTCHPLCHPLGFMCBPLCHLOCH125RBCH9MB270CHMLVolume 1—Residential and Light Commercial CA08100002E—September 2014 www.eaton.com V1-T1-391111111111111111111111111111111.1Loadcenters and Circuit BreakersType CH Loadcenters and Circuit BreakersShunt Trip OptionsHandle Position Changeability ChartNotes1 Add suffix indicated to end of breaker catalog number.2 Requires one additional pole space.Description Catalog NumberSuffix Adder 1Type VoltsCSR 12 DC SR12CSR 24 DC SR24CSR 120 AC SR01CH 120 AC ST 2CC 12 DC SR12CC 24 DC SR24CC 120 AC SR01CC 208 AC SR08CC 240 AC SR02Handle Lockoff andLockdog TypesTo Change Handle Position from ON to OFF or OFF to ON You Must...RemovePadlockRemoveDeviceRemove LoadcenterDeadfrontLockoff escutcheon mounted Remove — —Lockoff screw mounted Remove — —Lockdog handle mounted N/A Remove —V1-T1-40 Volume 1—Residential and Light Commercial CA08100002E—September 2014 www.eaton.com1111111111111111111111111111111.1 Loadcenters and Circuit BreakersType CH Loadcenters and Circuit BreakersTechnical Data and SpecificationsRatingsSingle- and two-pole CH breakers rated 15 and 20 A have low instantaneous magnetic trip levels. The 15 and 20 A breakers with “HM” suffix have high magnetic trip settings recommended for circuits with inherently high inrush currents. All Type CH breakers are marked for heating, air conditioning and refrigeration (HACR) equipment application. Single-pole 15–20 A breakers are also suitable for switching duty (SWD). Shunt trip coils operate on 120 Vac and require one additional pole space per breaker.Wiring DiagramsTypical Single-PoleSingle-Pole 120 V Load Application Sourced by 120/240 VacTwo-Pole Shared Neutral with Multi-Duplex Receptacle ApplicationTwo-Pole 240 V Load Application Sourced by 120/240 VacTwo-Pole Shared Neutral with Duplex Receptacle ApplicationSingle-Pole 120 V Duplex Receptacle ApplicationN A B120/240 VacSource120VDuplexReceptacleSingle-PoleLine BNeutralNeutralN A B120/240 VacSource120VDuplexReceptacleSingle-PoleLine BNeutralNeutralEquipment GroundN A B120/240 VacSourceTwo 120VDuplexReceptaclesTwo-PoleLine BLine ANeutralNeutralEquipment GroundLine BN A B120/240 VacSourceLine A 240VDuplexReceptacleTwo-PoleNeutralEquipment GroundN A B120/240 VacSourceLine A120V DuplexReceptacle(With Line SideJumper Removed)Two-PoleLine BNeutralNeutralEquipment GroundN A B120/240 VacSource120VDuplexReceptacleSingle-PoleLine BNeutralNeutralEquipment GroundVolume 1—Residential and Light Commercial CA08100002E—September 2014 www.eaton.com V1-T1-411111111111111111111111111111111.1Loadcenters and Circuit BreakersType CH Loadcenters and Circuit BreakersTwo-Pole 120 V Multi-Duplex Receptacle ApplicationTwo-Pole 120 V Duplex Receptacle ApplicationTwo-Pole 240 V Duplex Receptacle ApplicationN A B120/240 VacSourceTwo 120VDuplexReceptaclesTwo-PoleLine BLine ANeutralNeutralN A B120/240 VacSourceLine A120V DuplexReceptacle(With Line SideJumper Removed)Two-PoleLine BNeutralNeutralLine BN A B120/240 VacSourceLine A 240VDuplexReceptacleTwo-PoleNeutralV1-T1-42 Volume 1—Residential and Light Commercial CA08100002E—September 2014 www.eaton.com1111111111111111111111111111111.2 Loadcenters and Circuit BreakersType BR Loadcenters and Circuit BreakersType BR Loadcenters and Circuit Breakers ContentsDescription PageOverviewProduct Description . . . . . . . . . . . . . . . . . . . . . V1-T1-43Features, Benefits and Functions . . . . . . . . . . V1-T1-43Standards and Certifications . . . . . . . . . . . . . . V1-T1-45Catalog Number Selection. . . . . . . . . . . . . . . . V1-T1-45Product Selection. . . . . . . . . . . . . . . . . . . . . . . V1-T1-46BR Specialty ProductsSpa Panels . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-57Riser Panel. . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-58Type BR Renovation Loadcenter . . . . . . . . . . . V1-T1-59Type BR Mechanical Interlock Kits . . . . . . . . . . V1-T1-61Type BR Retrofit Interior Kits .
Most popular related searches

Contact supplier

Drop file here or browse