ERLPhase Power Technologies Ltd.

Model S-PRO 4000 - Sub-Harmonic Protection Relay Brochure

10 YearWARRANTYwww.erlphase.comSub-Harmonic Protection Relay S-PRO 4000Product OverviewThe S-PRO 4000 provides easy-to-use, state-of-the-art, comprehensive sub-harmonic protection for transmission lines at any voltage level, particularly those with serial compensation and interconnected with wind farms. It provides control, automation, metering, monitoring, fault oscillography, dynamic swing recording, and event logging with advanced communications in a fl exible cost effective package.Apply the S-PRO 4000 relay for protection and complete control in multi-breaker applications in ring or breaker-and-a-half arrangements. Real-time processing of voltage and current signals Frequency range 5 – 40 HzSub harmonics detection in one (1) secondFundamental frequency protection functions — IEEE devices 27, 50LS, 59Easy-to-use, intuitive setting and analysis software •••••Single and multi-breaker applications (i.e. ring bus and breaker-and-a-half capability) High quality fault and swing recording and event log8 setting groups for many operating conditionsEthernet ports with 2 unique MAC addresses accommodate network access security needs••••www.erlphase.comSub-harmonic protection for transmission lines at any voltage level, particularly those with serial compensation and interconnected with wind farms•Ease of UseEasy-to-use, install, and maintainEasy to order – No complex product codesUser-friendly, Windows®-based relay setting and record analysis softwareSetting software tool – relay specifi c applicationOn-line setting tool – terminal emulator (VT100)Flexible programmable logic for building customized schemes with ProLogicTM statements – 24 control logic statements (total of 192 statements)••••••Sub-Harmonic Detector – Frequency range 5 – 40 Hz Fundamental Frequency Protection functions — IEEE devices 27, 50LS, 59Enhanced user-confi gurable logic – with ProLogicTM which includes 24 control logic statements•••8 setting groups with unique Group Logic Control Statements – full Boolean graphics to create logic for setting groups switching based on a combination of given conditions•ApplicationProduct setting time – 240 x 128 LCD graphical user interface provides convenient means to check/change specifi c settings and parametersFront Panel Indicators – 11 user confi gurable LEDs, Relay Functional, IRIG-B Functional, Service Required, Test Mode, Alarm••Protection & ControlFeatures & Benefi tsReduce Installation and Operation Costwww.erlphase.comFlexible Communications2 rear ports, 100BASE-TX RJ-45 or 100BASE-FX 1300 nm multimode optical with ST style connector Ethernet ports with 2 unique MAC addresses that easily accommodate network access security needs Front panel USB and 100BASE-TX RJ-45 Ethernet port interfaces •••Enhanced DNP3 SCADA communication protocol including user-selectable point lists, class support and multiple master station supportModbus SCADA communication protocolIRIG-B port (through BNC connector) for precise time stamping and sample synchronization•••Serial communication port30 virtual inputs for local and remote controlOptional internal modem•••Exceptional fault recording capabilities (with 96 samples/cycle or 5760 Hz) and dynamic swing recording (at nominal frequency) Up to 30 x 10 second transient records, or up to 150 x 120 seconds swing records, or combination of transient, swing and optionally event records Metering functions for each input connectionSequence of Event Recorder – 250 events with 1 ms resolutionCompressed event record capabilities – a compressed sequence of event fi le is created approximately every 230 events•••••Substation Automation – Ethernet ReadyMulti-Functional Recording and Event LoggingDisplay multiple channels simultaneously and combine recordsDisplay multiple component voltage, current or summed channelsDisplay THD, harmonic magnitudeZoom, alignment, scaling, unit functionsRecord summaries including event listsCOMTRADE, PTI and MS Excel export••••••RecordGraphTM and RecordBase ViewTMwww.erlphase.comProtection & Control Function DiagramBest in Class Human-Machine InterfaceNavigation controls allow foran easy experience throughsettings, maintenance,service and view menusRear optical portsready for Ethernet connectivityProgrammable target LEDsprovide tripping informationto expedite response to system eventsUnique front panel USB andEthernet ports provide easyand fast access to settingsand set upLarge LCD display,allows for bettermetering displayNew fasterprocessor andhardware platform27 59 Rec.Bus 152-2PTPTCTLineFault Recording6 Voltages12 CurrentsProtection ElementsExternal InputsActive Setting GroupSwing RecordingPositive Sequence VoltagePositive Sequence CurrentSystem Frequency6 Analog Currents14 Output Contacts1 Relay InoperativeAlarm Contact59 2752-1 CTRec.Rec.Bus 29 External Inputs50LS50LS PLSub-HarmonicCurrent DetectorSub-HarmonicVoltage DetectorSub-HarmonicCurrent DetectorSub-HarmonicCurrent DetectorSub-HarmonicVoltage Detectorwww.erlphase.comDetailed Specifi cations S-PRO 4000 Sub-Harmonic Protection Relay for Transmission Systems Item Quantity/Specs Notes General Nominal Frequency 50 or 60 HzSub-Harmonics Frequencies 5 to 40 Hz Operating Time 16 – 25 ms typical Including relay output operationSampling Rate 96 samples/cycle Records up to 25th harmonicPower Supply Range: 43 – 275 Vdc, 90 – 265 Vac Power Consumption: 25 – 35 VA (ac) 25 – 35 W (dc)Sub-Harmonic Protection FunctionsSub-Harmonic Detection Frequency range: 5 – 40 Hz Time delay: 0 to 999 secondsSetting level: 5 – 100% absolute nominal,OR5 – 100% ratio sub-harmonic to fundamentalTotal Sub-Harmonic Distortion Frequency Range: 5 – 40 Hz Operations/minute setting: 0 – 999Fundamental Frequency Protection Functions IEEE Dev 27 & 59 2 x 3-phase voltage inputs0.1 – 1.2 x V rated Available for the 2 sets of voltage inputs on anAND/OR basisIEEE Dev 50LS 4 x 3-phase and summated currents0.2 – 50 Arms, 60 HzRing bus confi guration, available for everyindividual 3-phase current input and summated3-phase input ProLogic 24 statements per setting group 5 inputs per Prologic statement Setting Groups 8 (16 group logic statements per setting group) 5 inputs per statementRecordingRecord Capacity From up to 30 x 10 second to up to 150 x 2 second transient recordsorup to 150 x 120 seconds swing recordsorcombination of transient, swing and optionally event records with a total number of records limited to 150Transient record length is user confi gurable (range from 0.2 to 10 seconds); transient record pre-fault time is user confi gurable (range from 0.10 to 9 seconds)Swing record length is user confi gurable (range from 60 – 120 seconds); swing record pre-trigger time is fi xed at 30 secondsViewing software provides waveform, symmetrical components and harmonic analysisTransient 96 s/c oscillography of all analog and external input digital channelsSequence of Events Recorder 250 Events 1 ms resolution. When “event auto save” is enabled, a compressed event record is created is created approximately every 230 events.A/D Resolution 16 bits, 65536 counts full scale peak – peakInput & OutputAnalog Voltage Inputs2 sets of 3-phase voltage inputs(6 voltage channels)Nominal voltageContinuous rating over voltageMaximum over-scale thermal ratingThermal Rating BurdenVn = 69 Vrms2x Vn = 138 Vrms3x Vn = 207 Vrms for 10 seconds400 Arms for 1 second <0.15 VA @ 69 VrmsAnalog Current Inputs4 sets of 3-phase current inputs (12 current channels)Nominal currentFull scale/continuousMaximum full-scale ratingBurdenIn = 5 or 1 Arms3x In = 15 or 3 Arms40x In = 200 Arms or 40 Arms symmetrical<0.25 VA @ 5 Armswww.erlphase.comS-PRO 4000 Sub-Harmonic Protection Relay for Transmission Systems Item Quantity/Specs NotesInput & OutputExternal Inputs (digital) 9 inputs20 inputs (optional 4U model – future)Optional 48/125/250 Vdc nominal, externally wettedVirtual Inputs 30 Virtual InputsOutput (contacts) 14 programmable outputs and 1 relay inoperative output (3U model)21 inputs (optional 4U model - future)Externally wettedMake: 30 A as per IEEE C37.90Carry: 8 ABreak: 0.9 A at 125 Vdc0.35 A at 250 Vdc Interface & Communication Front Display 240 x 128 pixels graphics LCD Front Panel Indicators 16 LEDs: 11 programmable and 5 fi xed Target, Relay Functional, IRIG-B Functional, Service Required, Test Mode, Alarm Front User Interfaces USB port and 100BASE-T Ethernet port USB 2.0, RJ-45 Rear User Interfaces LAN Port 1: 100BASE – copper or optical 1300 nmLAN Port 2: 100BASE – copper or optical 1300 nm Copper: RJ-45, 100BASE-TOptical: 100BASE-FX, Multimode, 1300 nm,ST style connector Two Serial RS-232 ports to 115 kbd modem Com port can support an external modem Internal Modem 33.6 Kbps, V.32 bis Optional internal modem SCADA Interface DNP3 or Modbus DNP3: Ethernet or RS-232, Modbus: RS-232 Time Sync IRIG-B, BNC connector Modulated or unmodulated, auto-detect Self Checking/Relay Inoperative 1 contact Closed when relay inoperative Physical Weight 9.55 kg 21 lbs Dimensions 132 mm height x 482.6 mm width x 328 mm depth 5.2” height x 19” width x 12.9” depth Time Sychronization and Accuracy External Time Source Sychronized using IRIG-B input (modutated or unmodulated)auto detect EnvironmentalAmbient Temperature Range -40°C to 85°C for 16 hours-40°C to 70°C continuousIEC 60068-2-1, 2LCD contrast impaired for temperaturesbelow -20°C and above 70° CHumidity Up to 95% without condensation IEC 60068-2-30Insulation Test (Hi-Pot) Power supply, analog inputs, external inputs, outputcontacts at 2.0 kV, 50/60 Hz, 1 minuteIEC 60255-5, ANSI/IEEE C37.90Electrical Fast Transient Tested to level 4 – 4.0 kV 2.5/5 kHz on power and I/O lines IEEE C37.90.1: 4kV / IEC 60255-22-4Class 3 / IEC 61000-4-4: Level 3Oscillatory Transient Test level = 2.5 kV IEEE C37.90.1: 2.5 kV / IEC 60255-22-1:Level 3 / IEC 61000-4-12): Level 3RFI Susceptibility 10 V/m modulated, 35 V/unmodulated IEEE C37.90.2:35 V/m / (IEC 60255-22-3/IEC61000-4-3): Level 3Vibration, Shock and Bump 5 g and 15 g (IEC 60255-21-1,2 / IEC60068 2-6, 27): Class 1Conducted RF Immunity (IEC 60255-22-6 / IEC 61000-4-6): Level 3Voltage Interruptions 200 ms interrupt IEC 60255-11 / IEC 61000-4-11www.erlphase.com S-PRO 4000 Sub-Harmonic Protection Relay for Transmission SystemsDetailed Environmental TestsTest Description Test LevelType Test Test PointsFCC Part 15 RF emissions Enclosure ports Class A: 30 – 1000 MHzConducted emissions ac/dc power ports Class A: 0.15 – 30 MHzIEC/EN 60255-25 RF emissions Enclosure ports Class A: 30 – 1000 MHzConducted emissions ac/dc power ports Class A: 0.15 – 30 MHzIEC/EN 61000-3-2 Power line harmonics ac power port Class D: max.1.08, 2.3, 0.43, 1.14, 0.3, 0.77, 0.23 A.... for 2nd to nth harmonicdc power port N/AIEC/EN 61000-3-3 Power line fl uctuations ac power port THD/ 3%; Pst < 1, Plt < 0.65dc power port N/AIEC/EN 61000-4-2IEC/EN 60255-22-2ESD Enclosure contact +/- 6 kVEnclosure air +/- 8 kVIEEE C37.90.3 ESD Enclosure contact +/- 8 kVEnclosure air +/- 15 kVIEC/EN 61000-4-3IEC/EN 60255-22-3Radiated RFI Enclosure ports 10 V/m: 80 – 1000 MHzIEEE C37.90.2 Radiated RFI Enclosure ports 35 V/m: 25 – 1000 MHzIEC/EN 61000-4-4IEC/EN 60255-22-4IEEE C37.90.1Burst (fast transient) Signal ports +/- 4 kV @2.5 kHzac power port +/- 4 kVdc power Port +/- 4 kVEarth ground ports +/- 4 kVIEC/EN 61000-4-5IEC/EN 60255-22-5Surge Communication ports +/- 1 kV L-PESignal ports +/- 4 kV L-PE, +/-2 kV L-Lac power port +/- 4 kV L-PE, +/-2 kV L-Ldc power port +/- 2 kV L-PE, +/-1 kV L-LIEC/EN 61000-4-6IEC/EN 60255-22-6Induced (conducted) RFI Signal ports 10 Vrms: 0.150 – 80 MHzac power port 10 Vrms: 0.150 – 80 MHzdc power port 10 Vrms: 0.150 – 80 MHzEarth ground ports 10 Vrms: 0.150 – 80 MHzIEC/EN 60255-22-7 Power frequency Binary input ports: Class A Differential = 150 VrmsCommon = 300 VrmsIEC/EN 61000-4-8 Magnetic fi eld Enclosure ports 40 A/m continuous, 1000 A/m for 1 s IEC/EN 61000-4-11IEC/EN 61000-4-29Voltage dips & interrupts ac power port 30% for 1 period, 60% for 50 periods100% for 5 periods, 100% for 50 periodsdc power port 30% for 0.1 s, 60% for 0.1 s, 100% for 0.05 s IEC 60255-11 Voltage dips & interrupts dc power port 100% reduction for up to 200 mswww.erlphase.comERLPhase Power TechnologiesTel: 204-477-0591Email: info@erlphase.com The specifi cations and product information contained in this document are subject to change without notice. In case of inconsistencies between documents, the version at www.erlphase.com will be considered correct. (D03015R07) S-PRO 4000 Sub-Harmonic Protection Relay for Transmission SystemsDetailed Environmental TestsTest Description Test LevelType Test Test PointsIEC/EN 61000-4-12IEC/EN 60255-22-1Damped oscillatory Communication ports 1.0kV Common, 0 kV DiffSignal ports 2.5kV Common, 1 kV Diffac power port 2.5kV Common, 1 kV Diffdc power port 2.5kV Common, 1 kV DiffIEEE C37.90.1 Oscillatory Signal ports 2.5kV Common, 0 kV Diffac power port 2.5kV Common, 0 kV Diffdc power port 2.5kV Common, 0 kV DiffIEC/EN 61000-4-16 Mains frequency voltage Signal ports 30V continuous, 300V for 1sac power port 30V continuous, 300V for 1sIEC/EN 61000-4-17 Ripple on dc power supply dc power port 10%NOTE:The S-PRO 4000 is available with 5 or 1 amp current input. All current specifi cations change accordingly.
Most popular related searches