Senseca Italy S.r.l.
- Home
- Companies & Suppliers
- Senseca Italy S.r.l.
- Downloads
- Multifunction Meter
Multifunction Meter
DO 9847TP471D1TP471DTP471D0TP471TP472ITP474CTP473P242 MultifunctionIs a multifunctional handheld board instrument and datalogger.It is provided with a 128x64 pixel (56x38 mm) graphic display and three independent inputs. Each input can be connected to one channel or two channel dual probes (ex. two thermocouples, relative humidity/temperature, etc.).The instrument automatically recognises SICRAM probes connected to the input (memory equipped and configurable intelligent probe). Functions: watch, hold, max., min., average, record, immediate or deferred start record logging, difference between the two inputs, relative measures, three input channel meas-urement and inside reference temperature display. Sampling time: one per second/input.Probe calibration through SICRAM module; calibration data permanent storage inside the probe. Storage capacity: 32.000 readings per input.Storage interval and printing can be configured between one second and 1 hour.RS232C serial output: from 300 up to 115.200 baud rate.Immediate or deferred print-out.Stored data can be displayed and stored data blocks can be deleted.Automatic shutout after 8 minutes can be disabled.Units of measurement can be selected according to the physical quantity of the con-nected probe.Firmware update through RS232C serial port. Different types of SICRAM modules or probes can be connected to the input: Platinum sensor temperature, thermocouple, relative humidity/temperature, Discomfort index, continuous voltage (±20V), current (0…24mA), pressure, air speed and light.TeChnICal DaTa of The InsTrumenT Do9847- Power supply:Battery: 4 1.5V AA alkaline batteries; operating time with high quality batteries: about 60 hours.Mains: through 9Vdc, 250mA external power supply, 2 pole connector.- Operating conditions:Working temperature: -10...+50°C. Storage temperature: -25...+65°C.Relative Humidity: 0...90%R.H., not condensating.- LCD display: 128x64 pixel (56x38 mm) graphic LCD.- Keyboard: 18 multifuction Keys and 3 function keys.- Recorded data safety: independently from batteries charging conditions.- Measured values storage: on 16 files divided into 16-sample pages.- Quantity: 32.000 samples per input channel.- Storage interval: 1 s...1 h. Time and date, real time.Accuracy: 1 minute/month maximum error margin.- Serial interface: RS232C type galvanically insulated SUB D 9 male connector.Baud rate: 300...115.200 baud. Data bit: 8.Parity: none. Stop bit: 1.Flow control: Xon/Xoff. RS232C cable max.length: 15 m.- immediate printing interval: 1 s...1 h.- Firmware can be updated through PC using the instrument serial port.- Probes connections: n° 3 DIN45326 8 pole connectors- Dimensions and weight: 245x100x50 mm - 300 gr.- Case: ABS - Protection: rubber.Do 9847 - CharaCTerIsTICs of The sICram moDulesWhen the instrument is used together with the available sICram modules, its accu-racy and resolution are stated in the section where these modules are described.Do 9847PorTaBle mulTIfunCTIon DaTa-loGGer InsTrumenT243MultifunctionMultifunctionsICram moDules for Do 9847TP471 Temperature measure through PRT Platinum sensor PRT resistance values @ 0°C 25O, 100O, 500O temperature range Pt25, Pt100 -200°C … +850°C temperature range Pt500 -200°C … +500°C Accuracy with Pt25, Pt100 sensor ±0.03°C up to 350°C ±0.3°C up to 850°C Accuracy with Pt500 sensor ±0.5°C up to 500°C Resolution 0.01°C from -200°C to 350°C 0.1°C from 350°C to 800°C Temperature drift @20°C 0.002%/°C Excitation current 400µA impulse, length=100ms, time=1sTemperature measure for thermocouple with cold joint (inside ice at 0°C)TP471D0 Temperature measure for 1 input thermocouple TP471D1 Temperature measure for 2 input thermocoupleVP472 module to connect pyranometers or albedometers. The measurements pro-duced during the time by a pyranometer or an albedometer can be taken, verified and stored. The signal produced by the thermopile can be read in mV or in W/m2, the net radiation of the albedometer is read in W/m2. The thermo-pile sensitivity can be set from 5000 to 30000nV/(Wm-2) that is between 5 and 30µV/(Wm-2).VP473 module for reading the continuous voltage. When connected to the output of a transmitter with voltage signal it can read and take the relevant value. Measur-ing range: ±20Vdc. Input impedance: 1MO.IP472 module for mA reading of continuous current. When connected to the output of a trasmitter with current signal, it can read and take the relevant value. Meas-uring range: 0…24mA. Input impedance: 25O.PP471 module for measuring absolute, relative and differential pressure. It can be con-nected with pressure probes andseries. It measure the instantaneous value and peak value of pressure. The module is complete with 2m cable and DIN 45326 8 pole female connector. Accuracy: ±0.05% of full scale Peak time = 5ms Peak accuracy: ±0.5% f.s. Peak dead band = 2% f.s. ProBes anD moDules TeChnICal DaTa eQuIPPeD WITh InsTrumenTTemperature probes Pt100 sensor using sICram module model Type applicationrange accuracyTP472I Immersion -196°C…+500°C ±0.25°C (-196°C…+350°C) ±0.4°C (+350°C…+500°C) TP472I.0 Immersion -50°C…+400°C ±0.25°C (-50°C…+350°C) ±0.4°C (+350°C…+400°C) TP473P Penetration -50°C…+400°C ±0.25°C (-50°C…+350°C) ±0.4°C (+350°C…+400°C)TP473P.0 Penetration -50°C…+400°C ±0.25°C (-50°C…+350°C) ±0.4°C (+350°C…+400°C)TP474C Contact -50°C…+400°C ±0.3°C (-50°C…+350°C)±0.4°C (+350°C…+400°C) TP474C.0 Contact -50°C…+400°C ±0.3°C (-50°C…+350°C)±0.4°C (+350°C…+400°C) TP475A.0 Air -50°C…+250°C ±0.3°C (-50°C…+250°C)TP472I.5 Immersion -50°C…+400°C ±0.3°C (-50°C…+350°C) ±0.4°C (+350°C…+400°C)TP472I.10 Immersion -50°C…+400°C ±0.30°C (-50°C…+350°C) ±0.4°C (+350°C…+400°C)TP49A Immersion -70°C…+400°C ±0.25°C (-50°C…+350°C) ±0.4°C (+350°C…+400°C)TP49AC Contact -70°C…+400°C ±0.25°C (-50°C…+350°C) ±0.4°C (+350°C…+400°C)TP49AP Penetration -70°C…+400°C ±0.25°C (-50°C…+350°C) ±0.4°C (+350°C…+400°C)TP875 Globe thermometer Ø 150mm -30°C…+120°C ±0.25°CTP876 Globe thermometer Ø 150mm -30°C…+120°C ±0.25°CTP87 Immersion -50°C…+200°C ±0.25°CTP878TP878.1 For solar panel +5°C…+80°C ±0.25°CTP879 For compost -20°C…+120°C ±0.25°CCommon characteristicsTemperature drift @ 20°C 0.003%/°C4 wire Pt100 and 2 wire Pt1000 Probesmodel Type application range accuracyTP47.100 Pt100 4 wires -50…+400°C Classe ATP47.1000 Pt1000 2 wires -50…+400°C Classe ACommon characteristicsTemperature drift @ 20°C Pt100 0.003%/°C Pt1000 0.005%/°CunCerTaInTY anD resoluTIon of The InsTrumenT In measurInG WITh ThermoCouPlesTemperature measurement of the instrument Measuring range Tc: K -200…+1370°C Measuring range Tc: J -100…+750°C Measuring range Tc: T -200…+400°C Measuring range Tc: N -200…+1300°C Measuring range Tc: R +200…+1480°C Measuring range Tc: S +200…+1480°C Measuring range Tc: B +200…+1800°C Measuring range Tc: E -200…+750°Cresolution 0.05°C up to 199.95°C 0.1°C from 200.0°C to end scaleInstrument accuracy Thermocouple K ±0.1°C up to 600°C ±0.2°C above 600°C Thermocouple J ±0.05°C up to 400°C ±0.1°C above 400°C Thermocouple T ±0.1°C Thermocouple N ±0.1°C up to 600°C ±0.2°C above 600°C Thermocouple R ±0.25°C Thermocouple S ±0.3°C Thermocouple B ±0.35°C Thermocouple E ±0.1°C up to 300°C ±0.15°C above 300°Caccuracy is referred to the instrument only, error due to the thermocouple or to the cold junction reference sensor is not included.Temperature drift @20°C 0.02%/°CDrift after 1 year 0.1°C/yearType K Thermocouple probes accuracy of the thermocouple probesThe tolerance of a type of thermocouple corresponds to the maximum acceptable depar-ture from the e.m.f. of any thermocouple of that type, with reference junction at 0°C. The tolerance is expressed in degrees Celsius, preceded by the sign. The percentage tolerance is given by the ratio between the tolerance expressed in degrees Celsius and the meas-urement junction temperature, multiplied by one hundred. Tolerance classes for thermocouples (reference junction at 0°C) Type ofThermocoupleToleranceClass 1ToleranceClass 2ToleranceClass 3 (1)T Type Temperature interval ToleranceTemperature interval Tolerancefrom -40 to +125°C± 0.5°Cfrom 125 to 350°C± 0.004 · ltrfrom -40 to +133°C± 1°Cfrom 133 to 350°C± 0.0075 · ltrfrom -67 to +40°C± 1°Cfrom -200 to -67°C± 0.015 · ltre Type Temperature interval ToleranceTemperature interval Tolerancefrom -40 to +375°C± 1.5°Cfrom 375 to 800°C± 0.004 · ltrfrom -40 to +333°C± 2.5°Cfrom 333 to 900°C± 0.0075 · ltrfrom -167 to +40°C± 2.5°Cfrom -200 to -167°C± 0.015 · ltrJ Type Temperature interval ToleranceTemperature interval Tolerancefrom -40 to +375°C± 1.5°Cfrom 375 to 750°C± 0.004 · ltrfrom -40 to +333°C± 2.5°Cfrom 333 to 750°C± 0.0075 · ltr----K Type, n Type Temperature interval ToleranceTemperature interval Tolerancefrom -40 to +375°C± 1.5°Cfrom 375 to 1000°C± 0.004 · ltrfrom 40 to +333°C± 2.5°Cfrom 333 to 1200°C± 0.0075 · ltrfrom -167 to +40°C± 2.5°Cfrom -200 to -167°C± 0.015 · ltrr Type, s Type Temperature interval ToleranceTemperature interval Tolerancefrom 0 to +1100°C± 1°Cfrom 1100 to 1600°C± [ 1 + 0.003(t-1 100)] °Cfrom 0 to +600°C± 1.5°Cfrom 600 to 1600°C± 0.0025 · ltr----B Type Temperature interval ToleranceTemperature interval Tolerance------from 600 to 1700 °C± 0.0025 · ltrfrom +600 to +800C+ 4°Cfrom 800 to 1700°C± 0.005 · ltr(1) The materials used for thermocouples are generally supplied so to comply with the pro-duction tolerances specified in the table for temperatures over -40°C. Nevertheless, these materials may not comply with the production tolerances for low temperatures reported under Class 3, for T, E, K and N thermocouples when the thermocouples have to comply at the same time with the limits of Class 3 and those of Class 1 and/or Class 2. Ø 3300150Ø 4230Ø 5230Ø 3150Ø 4230Ø 5230Ø 4500Ø 61000Ø 6244 MultifunctionPT100 ProBes WITh sICram moDule for PorTaBle InsTrumenTsCoDe °C max t s DIMENSIONS useTP 472 I -196 +500 3sTP 473 P -50 +400 5sTP 474 C -50 +400 5sTP 472 I.0 -50 +400 3sTP 473 P.0 -50 +400 5sTP 474 C.0 -50 +400 5sTP 475 a.0 -50 +250 12sTP 472 I.5 -50 +400 3sTP 472 I.10 -50 +400 3s150Ø 2,7Ø 4150150Ø 2,770Ø 3230Ø 32140Ø 8Ø 21100015245MultifunctionMultifunctionPT100 ProBes WITh sICram moDule for PorTaBle InsTrumenTsCoDe °C max t s DIMENSIONS useTP 49 a -70 +400 3,5sTP 49 aC -70 +400 5,5sTP 49 aP -70 +400 4sTP 87 -50 +200 3sTP 878 +5 +80 60s Contact probe for solar panels. Cable L = 2m.TP 878.1 +5 +80 60s Contact probe for solar panels. Cable L = 5m.TP879 -20 +120 60s Penetration probe for compost. Cable L = 2mTP 875 -30+12015sGlobe-thermometer probe for measuring radiant heat ø150 mm. (ISO7243, ISO7726). 4 wires Pt100 Sensor cable L=2m. equipped with sICram module.TP 876 -30+12015sGlobe-thermometer probe for measuring radiant heat ø50 mm. (ISO7243, ISO7726). 4 wires Pt100 Sensor cable L=2m. equipped with sICram module.sonDe sensore Pt100 / Pt1000 Con moDulo TP 47CoDe °C max t s DIMENSIONS useTP 47.100(Pt100)TP 47.1000(Pt1000)-50 +400 3sTP 47Only connector for connection of probes without SICRAM module: direct 3 and 4 wires Pt100, 2 wires Pt1000.180Ø 1,590Ø 1,5230Ø 1,5180Ø 290Ø 2230Ø 2180Ø 3180Ø 4246 MultifunctionThermoCouPle ProBes for PorTaBle InsTrumenTsThermoCouPle K TYPe ProBes (Chromel - alumel)CoDe °C max t s DIMENSIONS useTP 741 800 2sTP 741/1 400 2sTP 741/2 800 2sTP 742 800 2sTP 742/1 400 2sTP 742/2 800 2sTP 743 800 3sTP 744 400 4s1801Ø 5110Ø 12Ø 3Ø 3500300Ø 325Ø 2200Ø 15Ø 1520035Ø 27300Ø 2730050247MultifunctionMultifunctionThermoCouPle K TYPe ProBes (Chromel - alumel)CoDe °C max t s DIMENSIONS useTP 745 500 5sTP 746 250 2sTP 750 1000 3sTP 750.0 800 3sTP 751 200 2sTP 754 500 2sTP 754/9 500 2sTP 755 800 2sTP 755/9 800 2s8022Ø 1,2Ø 1,6Ø 4150Ø 490500mmØ 5200356090Ø 235Ø 3Ø 1100Ø 20248 MultifunctionThermoCouPle K TYPe ProBes (Chromel - alumel)CoDe °C max t s DIMENSIONS useTP 756 200 2sTP 757 180 30sMAGNETIC PROBE FOR CONTACT MEASURE ON MAGNETIC METALLIC SURFACESTP 758 400 4sTP 758.1 400 4sTP 772 400 3sTP 774 250 2sTP 776 200 2sTP 777 200 3s 1m / 2m / 3m / 5m1200Ø 6700Ø 6Ø 6 ÷ 2570Ø 140Ø 3,540Ø 4500Ø 240Ø 41000Ø 2Ø 5500Ø 130249MultifunctionMultifunctionThermoCouPle K TYPe ProBes (Chromel - alumel)CoDe °C max t s DIMENSIONS useTP 647TP 647/2TP 647/3TP 647/53003003003002s2s2s2sSIT calibration up to 300°C.TP 651 1200 6sTP 652 1200 6sTP 655 180 2sTP 656 200 1sTP 656/1 1000 1sTP 656/2 1000 1sTP 657/1 100 5sTP 658 100 2s150Ø 3150Ø 4,58540L = 2mCs CmL = 2m40030250 MultifunctionThermoCouPle K TYPe ProBes (Chromel - alumel)CoDe °C max t s DIMENSIONS useTP 659 400 3sTP 660 400 4sTP 661 -60+5030sTP 662 110 120sPROBE WITH VELCRO TAPE FOR MEASURES ON PIPES MAX 110 DIAM.CmCs“K”“K”PW “K”response time for a 63% variation (t0.63)The response time t s is the reaction time of the sensor to a temperature variation, with a signal variation when measuring that corresponds to a given percentage (63%) of the variation.Response time is referred: For immersion probes in water at 100°C For surface probes in contact with metals surface at 200°C For air probe at an air temperature of 100°C170Ø 26170Ø 26130 120Ø 14130 215Ø 14110 560Ø 14110 52018x4480Ø 14130Ø 14251MultifunctionMultifunctionTemperature and relative humidity probes with sICram modulemodel TemperaturesensorCampo d’impiego accuracy%rh Temperature %rh TemphP472aCr Pt100 0…100%RH -20°C…+80°C±2%RH (5…90%RH)±2,5%RH (remaining range)±0.3°ChP572aCr Thermocouple K 0…100%RH -20°C…+80°C ±0.5°ChP473aCr Pt100 0…100%RH -20°C…+80°C ±0.3°ChP474aCr Pt100 0…100%RH -40°C…+150°C-40°C…150°C (180°C)±(1,5+0,02 times the displayed value)±0.3°ChP475aCr Pt100 0…100%RH -40°C…+150°C ±0.3°ChP475aC1r Pt100 0…100%RH -40°C…+150°C ±0.3°ChP477DCr Pt100 0…100%RH -40°C…+150°C ±0.3°ChP478aCr Pt100 0…100%RH -40°C…+150°C ±0.3°CCommon characteristicsRelative Humidity Sensor Capacitive Typical capacity @30%RH 300pFProbe temperatureworking range -40°C…+150°CWorking range 0 … 100%RHAccuracy ±1,5%RH (5…90%RH), ±2,5 remaining rangeResolution 0.1%RHTemperature drift @20°C 0.02%RH/°C %RH response time at 10sec (10?80%RH; air speed=2m/s) constant temperatureTemperature with Pt100 sensorResolution 0.1°CTemperature drift @20°C 0.003%/°CTemperature with thermocouple K-HP572AC Resolution 0.1°CTemperature drift @20°C 0.02%/°CrelaTIVe humIDITY anD TemPeraTure ProBesCode sensors rangerh - Temp. DImensIonshP472aCr RHPt1005 ÷ 98% RH-20°C…+80°ChP572aCrRHTC.KhP473aCrRHPt100hP474aCr5 ÷ 98% RH-40°C…+150°ChP475aCrhP475aC1rhP477DCrhP478aCrhP475aChP477DChP474aChP473aChP472aCTP704…TP705…252 MultifunctionProBes for Pressure measuremenTProbes complete with sICram modulePP471: SICRAM module interface between instrument and pressure probes of the series TP704 and TP705.PP472: Barometric probe, measuring range 600…1100mbar. Resolution: 0.1mbarAccuracy @ 20°C: ±0.3mbar. Temperature range: -10 … +60°CPP473s1…s8: Differential pressure probes. Working range s1=f.s.10mbar, s2=f.s.20mbar, s3=f.s.50mbar, s4=f.s.100mbar, s5=f.s.200mbar, s6=f.s.500mbar,s7=f.s.1bar, s8=f.s.2barMaximum overpressure s1,s2,s3=200mbar s4=300mbar s5,s6=1bars7=3bar s8=6barAccuracy @ 25°C ±0.5%f.s. (10, 20, 50mbar)±0.25%f.s. (100mbar)±0.12% f.s. (200, 500, 1000, 2000mbar)Temperature range -10 … +60°CFluid in contact with the membranenon-corrosive dry gas or airConnection tube Ø 5mmProbes to couple to the module to measure the absolute, relative or differential pressure.TP704…/TP705…: Probes to connect to SICRAM module PP471 for measuring relative, absolute or differential pressure.Pressure ProBe TaBleBottom scalepressuremaximumoverpressure resolutionorDer CoDes accuracyfrom 20 to 25°CWorkingtemperature ConnectionDifferential pressure relative pressure(compared to atmosphere) absolute pressureNON insulated membrane Insulated membrane Insulated membrane10.0 mbar 20.0 mbar 0.01 mbar • TP705-10MBD 0.5 % FSO 0..60 °C Tube Ø 5 mm20.0 mbar 40.0 mbar 0.01 mbar • TP705-20MBD 0.5 % FSO 0..60 °C Tube Ø 5 mm50.0 mbar 100 mbar 0.01 mbar TP705-50mBD 0.5 % FSO 0..60 °C Tube Ø 5 mm100 mbar 200 mbar 0.1 mbarTP705-100mBD 0.25 % FSO 0..60 °C Tube Ø 5 mmTP704-100mBGI 0.25 % FSO -10..+80 °C ¼ BSP200 mbar 400 mbar 0.1 mbarTP705-200mBD 0.25 % FSO 0..60 °C Tube Ø 5 mmTP704-200mBGI 0.25 % FSO -10..+80 °C ¼ BSP400 mbar 1000 mbar 0.1 mbar TP704-400mBGI 0.25 % FSO -10..+80 °C ¼ BSP500 mbar 1000 mbar 0.1 mbar TP705-500mBD 0.25 % FSO 0..60 °C Tube Ø 5 mm600 mbar 1000 mbar 0.1 mbar TP704-600mBGI 0.25 % FSO -40..125 °C ¼ BSP1.00 bar 2.00 bar 1 mbarTP705-1BD 0.25 % FSO 0..60 °C Tube Ø 5 mmTP705Baro 0.25 % FSO 0..60 °C Tube Ø 5 mm0.25 % FSO -40..125 °C ¼ BSPTP704-1Ba 0.25 % FSO -40..120 °C ¼ BSP2.00 bar 4.00 bar 1 mbarTP705-2BD 0.25 % FSO 0..60 °C Tube Ø 5 mmTP704-2BGI 0.25 % FSO -40..+125 °C ¼ BSPTP704-2BaI * 0.25 % FSO -25..+85 °C ¼ BSP5.00 bar 10.00 bar 1 mbarTP704-5BGI 0.25 % FSO -40..+125 °C ¼ BSPTP704-5BaI * 0.25 % FSO -25..+85 °C ¼ BSP10.00 bar 20.0 bar 0.01 barTP704-10BGI 0.25 % FSO -40..+125 °C ¼ BSPTP704-10BaI * 0.25 % FSO -25..+85 °C ¼ BSP20.0 bar 40.0 bar 0.01 barTP704-20BGI 0.25 % FSO -40..+125 °C ¼ BSPTP704-20BaI * 0.25 % FSO -25..+85 °C ¼ BSP50.0 bar 100.0 bar 0.01 barTP704-50BGI 0.25 % FSO -40..+125 °C ¼ BSPTP704-50BaI * 0.25 % FSO -25..+85 °C ¼ BSP100 bar 200 bar 0.1 mbarTP704-100BGI 0.25 % FSO -40..+125 °C ¼ BSPTP704-100BaI * 0.25 % FSO -25..+85 °C ¼ BSP200 bar 400 bar 0.1 mbarTP704-200BGI 0.25 % FSO -40..+125 °C ¼ BSPTP704-200BaI * 0.25 % FSO -25..+85 °C ¼ BSP500 bar1000 bar 0.1 mbar TP704-500BGI 0.25 % FSO -40..+125 °C ¼ BSP700 bar 0.1 mbar TP704-500BaI * 0.25 % FSO -25..+85 °C ¼ BSP * Ceramic diaphragm • Only report of calibration, no SIT certificateT4...T3...T3...T2...T2...T1...aP472s1…aP472s2…aP472s4…aP471s3aP471s2aP471s1253MultifunctionMultifunctionProBes anD moDules TeChnICal DaTa eQuIPPeD WITh InsTrumenTWind speed measurement probeshot-wire probes: aP471 s1 - aP471 s2 - aP471 s3 - aP471 s4aP471 s1 - aP471 s3 aP471 s2 aP471 s4Type of measure Air speed, calculated flow rate, air temperatureType of sensorSpeed NTC thermistor Omnidirectional NTC thermistorTemperature NTC thermistor NTC thermistorMeasurement rangeSpeed 0,1…40m/s 0,1…5m/sTemperature -25…+80°C -25…+80°C 0…80°CMeasurement resolution:Speed0.01 m/s0.1 km/h1 ft/min0.1 mph0.1 knotTemperature 0.1°CMeasurement accuracy:Speed ±0.1 m/s (0…0.99 m/s) ±0.05m/s (0…0.99 m/s)±0.3 m/s (1.00…9.99 m/s) ±0.15m/s (1.00…5.00 m/s)±0.8 m/s (10.00…40.0 m/s)Temperature ±0.8°C (-10…+80°C) ±0.8°C (-10…+80°C)Minimum speed 0.1 m/sAir temperaturecompensation 0…80°CSensor working conditions Clean air, RH<80%Battery life Approx. 20 hours @ 20 m/s with alkaline batteriesApprox. 30 hours @ 5 m/s with alka-line batteriesUnit of MeasurementSpeed m/s – km/h – ft/min – mph – knotFlow rate l/s - m3/s - m3/min - m3/h - ft3/s - ft3/minPipeline section for flow rate calculation 0.0001…1.9999 m2Cable length ~2mVane probes: aP472 s1… - aP472 s2 - aP472 s4…aP472 s1… aP472 s2aP472 s4…l lT h hTType of measureAir speed,calculated flow rate,air temperatureAir speed,calculated flow rateAir speed,calculated flow rate.Air speed,calculated flow rate,air tempera-ture.Air speed,calculated flow rate.Air speed,calculated flow rate,air tempera-ture.Diameter 100mm 60mm 16mmType of measurementSpeed Vane Vane VaneTemperature K thermocouple ---- ---- K thermocouple ----K thermocouple Measurement rangeSpeed (m/s) 0.6…25 0.5…20 0.8…20 10…40Temperature (°C) -25…+80 (*) -25...+80 (*)ResolutionSpeed0.01 m/s0.1 km/h1 ft/min0.1 mph0.1 knotTemperature 0.1°C ---- ---- 0.1°C ---- 0.1°CAccuracySpeed ±(0.3 m/s +1.5%f.s.)±(0.3m/s +1.5%f.s.) ±(0.4 m/s +1.5%f.s.)Temperature ±0.8°C ---- ---- ±0.8°C ---- ±0.8°CMinimum speed 0.6m/s 0.5m/s 0.8m/s 10m/sUnit of MeasurementSpeed m/s – km/h – ft/min – mph – knotFlow rate l/s - m3/s - m3/min - m3/h - ft3/s - ft3/minPipeline section for flow rate calculation 0.0001…1.9999 m2Cable length ~2m(*) The indicated value refers to the vane’s working range.lP471lum2lP471PhoTlP471raDlP471ParlP471uValP471uVBlP471uVCaP471s4254 MultifunctionPitot tube probes: aP473 s1 - aP473 s2 - aP473 s3 - aP473 s4aP473 s1 aP473 s2 aP473 s3 aP473 s4Kind ofmeasurementAir speed, calculated flow, differential pressure, Air temperatureWorking rangeDiff. pressure 10 mbar f.s. 20mbar f.s. 50mbar f.s. 100mbar f.s.Speed (*) 2 … 40m/s 2 … 55m/s 2 … 90m/s 2 … 130m/sTemperature -200…+600°C -200…+600°C -200…+600°C -200…+600°CResolutionSpeed m/s 0.1km/h 1ft/min 1.103mph 1Knots 1Temperature 0.1°CAccuracy Speed ±0.4%f.s. of pressure ±0.3%f.s. of pressureTemperature ±0.8°C ±0.8°CMinimum speed 2 m/sAir temperature compensation -200…+600°C (if K thermocouple is connected to the module)Unit of measurementSpeed m/s - km/h - ft/min - mph - KnotsFlow rate l/s - m3/h - m3/min - ft3/s - ft3/minDuct section for flow calculation .001…1.999 m2(*) A 20°C, 1013mbar and Ps negligible.PhoTomeTrIC anD raDIomeTrIC ProBesTechnical characteristics of photometric and radiometric probes complete with sICram module equipped with the instrumentsIllumInanCe measurement probe lP 471 PhoTMeasurement range (lux): 0.01…199.99 …1999.9 …19999 …199.99·103Resolution (lux): 0.01 0.1 1 0.01·103Spectral range: in agreement with standard photopic curve V(?)Class C (B on request)Calibration uncertainty: <4%f’1 (in agreement with photopic response V(?)): <8%f2 (response according to the cosine law): <3%f3 (linearity): <1%f4 (instrument reading error): <0.5%f5 (fatigue): <0.5%a (temp. coefficient) f6 (T) <0.05%KDrift after 1 year: <1%Functioning temperature: 0…50°CReference Standards CIE n.69 - UNI 11142Photometric probe for IllumInanCe measurement,spectral response in agreement with standardphotopic vision, diffuser for cosine correction.Measurement range: 0.01 lux…200·103 lux. 00,10,20,30,40,50,60,70,80,91380 430 480 530 580 630 680 730 780 830? (nm)0 0,1 0,2 0,3 0,4 0,5 0,6 0,7 0,8 0,9 1 350 450 550 650 750 850 950 1050 ? (nm) 00,10,20,30,40,50,60,7350 400 450 500 550 600 650 700 750 800 850Relative spectral responsePAR? (nm)0 0,1 0,2 0,3 0,4 0,5 0,6 0,7 0,8 0,9 1 280 300 320 340 360 380 400 420 ? (nm) 255MultifunctionMultifunctionlumInanCe measurement probe lP 471 lum 2Measurement range (cd/m2): 0.1…1999.9 …19999 …199.99·103 …1999.9·103Resolution (cd/m2): 0.1 1 0.01·103 0.1·103Optical angle: 2°Spectral range: in agreement with standard photopic curve V(?)Class CCalibration uncertainty: <5%f’1 (in agreement with photopic response V(?)): <8%f3 (linearity): <1%f4 (instrument reading error): <0.5%f5 (fatigue): <0.5%a (temp. coefficient) f6 (T) <0.05%KDrift after 1 year: <1%Functioning temperature: 0…50°CReference Standards CIE n.69 - UNI 11142Photometric probe for lumInanCe measurement, spectral responsein agreement with standard photopic vision, vision angle 2°.Measurement range: 0.1 cd/m2…2000·103 cd/m2.Typical response curve: LP 471 PHOT and LP471 LUM 2Quantum radiometric probe for the measurement of the photon flow across the chlorophyll range Par lP 471 ParMeasurement range (µmolm-2s-1): 0.01… 199.99 200.0…1999.9 2000…10000Resolution (µmolm-2s-1): 0.01 0.1 1Spectral range: 400nm…700nm Calibration uncertainty: <5%f’1 (response according to the cosine law): <6%f3 (linearity): <1%f4 (instrument reading error): ±1digitf5 (fatigue): <0.5%Drift after 1 year: <1%Working temperature: 0…50°CQuantum radiometric probe for the measurement of thephoton flow across the chlorophyll range Par(Photosynthetically Active Radiation 400nm…700nm),measurement in µmol/m2s. Measurement range:0.01µmol/m-2s-1…10·103µmol/m-2s-1.Typical response curve: LP 471 PARIrraDIanCe measurement probe lP 471 raD Measurement range (W/m2): 0.1·10-3… 999.9·10-3 1.000…19.99920.00…199.99200.0…1999.9Resolution (W/m2): 0.1·10-3 0.001 0.01 0.1Spectral range: 400nm…1050nm Calibration uncertainty: <5%f’1 (response according to the cosine law): <6%f3 (linearity): <1%f4 (instrument reading error): ±1digitf5 (fatigue): <0.5%Drift after 1 year: <1%Working temperature: 0…50°CRadiometric probe for IrraDIanCe measurement in thespectral range 400nm…1050nm, diffuser for cosinecorrection. Measurement range:0.1·10-3W/m2 …2000 W/m2.Typical response curve: LP 471 RADIrraDIanCe measurement probe lP 471 uVaMeasurement range (W/m2): 0.1·10-3… 999.9·10-3 1.000…19.99920.00…199.99200.0…1999.9Resolution (W/m2): 0.1·10-3 0.001 0.01 0.1Spectral range: 315nm…400nm (Peak 360nm)Calibration uncertainty: <5%f’1 (response according to the cosine law): <6%f3 (linearity): <1%f4 (instrument reading error): ±1digitf5 (fatigue): <0.5%Drift after 1 year: <2%Working temperature: 0…50°CRadiometric probe for IrraDIanCe measurement, in the315nm…400nm, peak 360nm, uVa spectral range.Measurement range: 0.1·10-3W/m2…2000 W/m2.Typical response curve: LP 471 UVARisposta spettrale relativaRisposta spettrale relativaRisposta spettrale relativaRisposta spettrale relativa0 0,1 0,2 0,3 0,4 0,5 0,6 0,7 0,8 0,9 1 250 260 270 280 290 300 310 320 330 340 350 ? (nm) 0,00001 0,0001 0,001 0,01 0,1 1 10 250 270 290 310 330 350 370 390 ? (nm) 0 0,1 0,2 0,3 0,4 0,5 0,6 0,7 0,8 0,9 1 200 210 220 230 240 250 260 270 280 290 300 ? (nm) 256 MultifunctionIrraDIanCe measurement probe lP 471 uVBMeasurement range (W/m2): 0.1·10-3… 999.9·10-3 1.000…19.99920.00…199.99200.0…1999.9Resolution (W/m2): 0.1·10-3 0.001 0.01 0.1Spectral range: 280nm…315nm (Peak 305nm)Calibration uncertainty: <5%f’1 (response according to the cosine law): <6%f3 (linearity): <2%f4 (instrument reading error): ±1digitf5 (fatigue): <0.5%Drift after 1 year: <2%Working temperature: 0…50°CRadiometric probe for IrraDIanCe measurement,in the spectral range 280nm…315nm, peak 305nm,uVB. Measurement range: 0.1·10-3W/m2…2000 W/m2.Typical response curve: LP 471 UVBIrraDIanCe measurement probe lP 471 uVCMeasurement range (W/m2): 0.1·10-3… 999.9·10-31.000…19.99920.00…199.99200.0…1999.9Resolution (W/m2): 0.1·10-3 0.001 0.01 0.1Spectral range: 220nm…280nm (Peak 260nm)Calibration uncertainty: <5%f’1 (response according to the cosine law): <6%f3 (linearity): <1%f4 (instrument reading error): ±1digitf5 (fatigue): <0.5%Drift after 1 year: <2%Working temperature: 0…50°CRadiometric probe for IrraDIanCe measurement,in the spectral range 220nm…280nm, peak 260nm,uVC. Measurement range: 0.1·10-3W/m2…2000 W/m2.Typical response curve: LP 471 UVCmeasurement probe lP 471erY of ToTal effeCTIVe IrraDIanCe (W/m2) according to the uV action curve uV (CeI en 60335-2-27)Measurement range (Weff /m2): 0.1·10-3… 999.9·10-3 1.000…19.99920.00…199.99200.0…1999.9Resolution (Weff /m2): 0.1·10-3 0.001 0.01 0.1Spectral range: UV action curve for erythema measurement (250nm…400nm)Calibration uncertainty: <15%f3 (linearity): <3%f4 (instrument reading error ±1digit f5 (fatigue): <0.5%Drift after 1 year <2%Working temperature: 0…50°CReference standard CEI EN 60335-2-27Radiometric probe for effeCTIVe ToTal IrraDIanCe(Weff /m2) according to the UV action curve(CIE EN 60335-2-27). Spectral range: 250 nm…400 nm,Measurement range: 0.1·10-3Weff /m2 … 2000 Weff /m2Typical response curve. TOTAL EFFECTIVE IRRADIANCE LP 471 ERYRisposta spettrale relativaRisposta spettrale relativaRisposta spettrale relativaSolid line = Action curveDashed line = Spectral sensitivity LP471ERY probeThe probe LP 471 ERY measures the total effective irradiance (Weff/m2) according to the UV action curve (CEI EN 60335-2-27). A particular type of photodiode and a combination of special filters bring the spectral response closer to the UV action curve.CEI EN 60335-2-27 standards estabilish a maximum allowable dose of 100J/m2 for first-time exposure and an annual dose of 15000J/m2.The typical spectral response curve of LP 471 ERY is shown in the Figure together with the UV action curve.The good accordance between the two curves enables the instrument to take reliable measurements of different types of lamps (and filters) used at present for tanning machines.Each probe is individually calibrated at DeltaOhm photo-radiometry laboratory by means of a double monochrome. Calibration is performed at 290 nm through a sIT calibra-ted reference photodiode.PP473-s... aP473-s3PP472257MultifunctionMultifunctionorDerInG CoDes Do 9847K: The kit is provided with multifunctional instrument, 9CPRS232 serial output cable, 4 1.5V alkaline batteries, instruction manual and carrying case. modules and probes have to be ordered separately . 9CPrs232: Female/female sub D 9 pole extension cable for RS232C (null modem). Deltalog3: Software for downloading and PC data management.TP471: Measures the temperature with PRT Platinum sensors Resistance values of the PRT @ 0°C 25O, 100O, 500O Measuring range Pt25, Pt100 -200°C…+850°C Measuring range Pt500 -200°C…+500°C Accuracy with Pt25, Pt100 sensor ±0.03°C till 350°C ±0.3°C till 500°C Accuracy with Pt500 sensor ±0.5°C till 500°C Resolution 0.01°C from -200°C till 350°C 0.1°C from 350°C till 850°C Temperature drift @20°C 0.02%/°C Excitation current 400µA impulse, length=100ms, time=1s TP471D0: Measures the temperature with thermocouple, cold junction at 0°C inside ice. TP471D: Measures the temperature with thermocouple, 1 inputTP741D1: Measures the temperature with thermocouple, 2 inputsVP472: Module for connecting pyranometers or albedometers. For acquisition, verifica-tion, and storage of the values generated by a pyranometer or albedometer. The generated value can be read in mV or in W/m², the net radioation of the albedometer is read in W/m². The sensitivity can be set between 5000 and 30000nV/(W/m²), or rather between 5 and 30µV/(W/m²).VP473: Module for reading continuous voltage. Reads and acquires values when con-nected to a transmitter with voltage signal. Measuring range ±20Vdc. Input imped-ance: 1MO. IP472: Module for reading continuous current. Reads and acquires current values when connected to a transmitter with current output. Measuring range 0…24mA Input impedance: 25O. PP471: Module for the measurement of absolute, relative, and differential pressure. Works with pressure probes of the series TP704 and TP705. Provides instanta-neous value and pressure peak value. Includes cable L=2 and 8-pole DIN 45326 female connector. Accuracy: ±0.05% of f.s. Peak time: = 5ms Accuracy of the peak: ±0.5% f.s Peak dead band: = 2% f.s. Probes complete with sICram moduleTemPeraTure measuremenT ProBesTP472I: Immersion probe, sensor Pt100. Stem Ø 3 mm, length 300 mm. Cable length 2 metres.TP472I.0: Immersion probe, sensor Pt100. Stem Ø 3 mm, length 230 mm. Cable length 2 metres.TP473P: Penetration probe, sensor Pt100. Stem Ø 4mm, length 150 mm. Cable length 2 metres.TP473P.0: Penetration probe, sensor Pt100. Stem Ø 4mm, length 150 mm. Cable length 2 metres.TP474C: Contact probe, sensor Pt100. Stem Ø 4mm, length 230mm, contact surface Ø 5mm. Cable length 2 metres.TP474C.0: Contact probe, sensor Pt100. Stem Ø 4mm, length 230mm, contact surface Ø 5mm. Cable length 2 metres.TP475a.0: Air probe, sensor Pt100. Stem Ø 4mm, length 230mm. Cable length 2 metres.TP472I.5: Immersion probe, sensor Pt100. Stem Ø 6mm, length 500 mm. Cable length 2 metres.TP472I.10: Immersion probe, sensor Pt100. Stem Ø 6mm, length 1,000mm. Cable length 2 metres.TP49a: Immersion probe, Pt100 sensor. Stem Ø 2.7 mm, Length 150 mm. Cable 2 meters long. Aluminium handle.TP49aC: Contact probe, Pt100 sensor. Stem Ø 4 mm, Length 150 mm. Cable 2 meters long. Aluminium handle.TP49aP: Penetration probe, Pt100 sensor. Stem Ø 2.7 mm, Length 150 mm. Cable 2 meters long. Aluminium handle.TP875: Globe thermometer Ø 150 mm with handle. Cable 2 metresTP876: Globe thermometer Ø 50 mm with handle. Cable 2 metres.TP87: Immersion probe, Pt100 sensor. Stem Ø 3 mm, lenght 70 mm. Cable 2 metres.TP878: Contact probe for solar panels. Cable 2 metres.TP878.1: Contact probe for solar panels. Cable 5 metres.TP879: Penetration probe for compost. Stem Ø 8 mm, Length 1 m. Cable 2 meters.Temperature probes without sICram moduleTP47.100: Immersion probe, 4 wire direct Pt100 sensor. Stem Ø 3mm, length 230mm. 4 wire connecting cable with connector, length 2 metres.TP47.1000: Immersion probe, 4 wire direct Pt1000 sensor. Stem Ø 3mm, length 230mm. 4 wire connecting cable with connector, length 2 metres.TP47: Connector for probes connection: 4 wire direct Pt100.T3-800TCPWaP471s2aP471s1258 Multifunctionrelative humidity and temperature probes complete with sICram modulehP472aCr: %RH and temperature combined probe, dimensions Ø 26x170 mm. 2 m connecting cable.hP572aCr: %RH and temperature combined probe, K thermocouple sensor. Dimen-sions Ø 26x170 mm. 2 m connecting cable. hP473aCr: %RH and temperature combined probe. Dimensions: handle Ø 26x130 mm, probe Ø 14x110 mm. 2m connecting cable.hP474aCr: %RH and temperature combined probe. Dimensions: handle Ø 26x130 mm, probe Ø 14x210 mm. 2m connecting cable.hP475aCr: %RH and temperature combined probe. 2 m connecting cable. Handle Ø 26x110 mm. Stainless-steel tube Ø 12x560 mm. Terminal tip Ø 13.5x75 mm.hP475aC1r: %RH and temperature combined probe. 2 m connection cable. Handle Ø 26x110 mm. Stainless steel stern Ø 14x480 mm.hP477DCr: %RH and temperature combined sword probe. 2 m connecting cable. Handle Ø 26x110 mm. Probe tube 18x4 mm, length 520 mm.hP478aCr: %RH and temperature combined probe. Dimensions Ø 14x130 mm. 5m con-nection cable.ProBes for Pressure measuremenTProbes complete with sICram modulePP471: SICRAM module interface between instrument and pressure probes of the series TP704 and TP705.PP472: Barometric probe, measuring range 600…1100mbar. Resolution: 0.1mbarAccuracy @ 20°C: ±0.3mbar. Temperature range: -10 … +60°CPP473s1…s8: Differential pressure probes. Working range s1=f.s.10mbar, s2=f.s.20mbar, s3=f.s.50mbar, s4=f.s.100mbar, s5=f.s.200mbar, s6=f.s.500mbar,s7=f.s.1bar, s8=f.s.2barMaximum overpressure s1,s2,s3=200mbar s4=300mbar s5,s6=1bars7=3bar s8=6barAccuracy @ 25°C ±0.5%f.s. (10, 20, 50mbar)±0.25%f.s. (100mbar)±0.12% f.s. (200, 500, 1000, 2000mbar)Temperature range -10 … +60°CFluid in contact with the membranenon-corrosive dry gas or airConnection tube Ø 5mmProbes to couple to the module to measure the absolute, relative or differential pressure.TP704…/TP705…: Probes to connect to SICRAM module PP471 for measuring relative, absolute or differential pressure.ProBes for aIr sPeeD measuremenTs Probes equipped with sICram moduleshoT-WIre ProBesaP471 s1: Hot-wire telescopic probe, measuring range: 0.1…40m/s. aP471 s2: Omni-directional hot-wire probe, measuring range: 0.1…5m/s.aP471 s3: Hot-wire telescopic probe with terminal tip for easy position, measuring range: 0.1…40m/s.aP471 s4: Omnidirectional hot-wire telescopic probe with base, measuring range: 0.1…5m/s. Cable length 2 metres.Vane probes:aP472 s1: Vane probe with thermocouple, Ø 100mm. Speed from 0.6 to 25m/s; tem-perature from -25 to 80°C. Cable length 2 metres.aP472 s2: Vane probe, Ø 60mm. Measurement range: 0.5…20m/s. Cable length 2 metres.aP472 s4l: Vane probe, Ø 16mm. speed from 0.8 to 20m/s. Cable length 2 metres.aP472 s4lT: Vane probe with thermocouple, Ø 16mm, speed from 0.8 to 20m/s. Tem-perature from -25 to 80°C with thermocouple K sensor(*). Cable length 2 metres.aP472 s4h: Vane probe, Ø 16mm speed from 10 to 40m/s. Cable length 2 metres.aP472 s4hT: Vane probe with thermocouple, Ø 16mm speed from 10 to 40m/s. Tem-perature from -25 to 80°C with thermocouple K sensor(*). Cable length 2 metres.moDules for PIToT TuBesaP473 s1: Pitot tube probe, differential pressure 10mbar f.s. Air speed from 2 to 40m/s. The Pitot tube has to be ordered separately.aP473 s2: Pitot tube probe, differential pressure 20mbar f.s. Air speed from 2 to 55m/s. The Pitot tube has to be ordered separately. aP473 s3: Pitot tube probe, differential pressure 50mbar f.s. Air speed from 2 to 90m/s. The Pitot tube has to be ordered separately. aP473 s4: Pitot tube probe, differential pressure 100mbar f.s. Air speed from 2 to 130m/s. The Pitot tube has to be ordered separately.PW: Connection cable between AP473S… module and Pitot tube.lP BlaP472s1aP471s1259MultifunctionMultifunctionPIToT TuBesStainless steel Pitot tubes to measure air speed and temperature for models provided with ‘K’ thermocouple. They can be connected to the SICRAM modules AP473S1, AP473S2, AP473S3 and AP473S4d1dLL1L 2Ddmmd1mmDmmlmml1mml2mm Temp.°CThermo-couple K materialT1-300 3 1 6 300 30 720…600°C---AISI 316T2-400 5 2 8 400 45 120 ---T2-600 5 2 8 600 45 120 ---T3-500 8 3.2 8 500 --- 192 ---T3-800 8 3.2 8 800 --- 192 ---T3-800TC 8 3.2 8 800 --- 192 TCT4-500 10 4.0 10 500 --- 240 ---T4-800 10 4.0 10 800 --- 240 ---T4-800TC 10 4.0 10 800 --- 240 TCT4-1000 10 4.0 10 1000 --- 240 ---T4-1000TC 10 4.0 10 1000 --- 240 TCProBes for lIGhT measuremenTProbes complete with sICram modulelP 471 PhoT: Photometric probe for IllumInanCe measurement complete with SICRAM module, spectral response in agreement with standard photopic vision, diffuser for cosine correction. Measurement range: 0.01 lux…200·103 lux.lP 471 lum 2: Photometric probe for lumInanCe measurement complete with SICRAM module, spectral response in agreement with standard photopic vision, vision angle 2°. Measurement range: 0.1 cd/m2…2000·103 cd/m2.lP 471 Par: Quantum radiometric probe for the measurement of the photon flow across the chlorophyll range Par (Photosynthetically Active Radiation 400nm…700nm) complete with SICRAM, measurement in µmol/m2s, diffuser for cosine correction. Measurement range: 0.01µmol/m2s…10·103µmol/m2s.lP 471 raD: Radiometric probe for IrraDIanCe measurement complete with SICRAM module; in the 400nm…1050nm spectral range, diffuser for cosine correction. Measurement range: 0.1·10-3W/m2 …2000 W/m2.lP 471 uVa: Radiometric probe for IrraDIanCe measurement complete with SICRAM module; in the 315nm…400nm, peak 360nm, uVa spectral range, quartz diffuser for cosine correction. Measurement range: 0.1·10-3W/m2…2000 W/m2.lP 471 uVB: Radiometric probe for IrraDIanCe measurement complete with SICRAM module, in the 280nm…315nm, peak 305nm, uVB spectral range, quartz diffuser for cosine correction. Measurement range: 0.1·10-3W/m2…2000 W/m2.lP 471 uVC: Radiometric probe for IrraDIanCe measurement complete with SICRAM module, in the 220nm…280nm, peak 260nm, uVC spectral range, quartz diffuser for cosine correction. Measurement range: 0.1·10-3W/m2…2000 W/m2.lP 471 erY: Radiometric probe for ToTal effeCTIVe IrraDIanCe (Weff/m2) according to the UV action curve (CEI EN 60335-2-27) complete with SICRAM module. Spec-tral range: 250 nm…400 nm, quartz diffuser for cosine correction. Measurement range: 0.1·10-3Weff /m2 … 2000 Weff /m2.lP Bl: Base with levelling device for the probes (except LP 471 LUM2).lP 471 lum 2
Most popular related searches
