Senseca Italy S.r.l.

Multifunction Meter

DO 9847 TP471D1 TP471D TP471D0 TP471 TP472I TP474C TP473P 242 Multifunction Is a multifunctional handheld board instrument and datalogger. It is provided with a 128x64 pixel (56x38 mm) graphic display and three independent inputs. Each input can be connected to one channel or two channel dual probes (ex. two thermocouples, relative humidity/temperature, etc.). The instrument automatically recognises SICRAM probes connected to the input (memory equipped and configurable intelligent probe). Functions: watch, hold, max., min., average, record, immediate or deferred start record logging, difference between the two inputs, relative measures, three input channel meas- urement and inside reference temperature display. Sampling time: one per second/input. Probe calibration through SICRAM module; calibration data permanent storage inside the probe. Storage capacity: 32.000 readings per input. Storage interval and printing can be configured between one second and 1 hour. RS232C serial output: from 300 up to 115.200 baud rate. Immediate or deferred print-out. Stored data can be displayed and stored data blocks can be deleted. Automatic shutout after 8 minutes can be disabled. Units of measurement can be selected according to the physical quantity of the con- nected probe. Firmware update through RS232C serial port. Different types of SICRAM modules or probes can be connected to the input: Platinum sensor temperature, thermocouple, relative humidity/temperature, Discomfort index, continuous voltage (±20V), current (0…24mA), pressure, air speed and light. TeChnICal DaTa of The InsTrumenT Do9847 - Power supply: Battery: 4 1.5V AA alkaline batteries; operating time with high quality batteries: about 60 hours. Mains: through 9Vdc, 250mA external power supply, 2 pole connector. - Operating conditions: Working temperature: -10...+50°C. Storage temperature: -25...+65°C. Relative Humidity: 0...90%R.H., not condensating. - LCD display: 128x64 pixel (56x38 mm) graphic LCD. - Keyboard: 18 multifuction Keys and 3 function keys. - Recorded data safety: independently from batteries charging conditions. - Measured values storage: on 16 files divided into 16-sample pages. - Quantity: 32.000 samples per input channel. - Storage interval: 1 s...1 h. Time and date, real time. Accuracy: 1 minute/month maximum error margin. - Serial interface: RS232C type galvanically insulated SUB D 9 male connector. Baud rate: 300...115.200 baud. Data bit: 8. Parity: none. Stop bit: 1. Flow control: Xon/Xoff. RS232C cable max.length: 15 m. - immediate printing interval: 1 s...1 h. - Firmware can be updated through PC using the instrument serial port. - Probes connections: n° 3 DIN45326 8 pole connectors - Dimensions and weight: 245x100x50 mm - 300 gr. - Case: ABS - Protection: rubber. Do 9847 - CharaCTerIsTICs of The sICram moDules When the instrument is used together with the available sICram modules, its accu- racy and resolution are stated in the section where these modules are described. Do 9847 PorTaBle mulTIfunCTIon DaTa-loGGer InsTrumenT 243 M ul tif un ct io n Multifunction sICram moDules for Do 9847 TP471 Temperature measure through PRT Platinum sensor PRT resistance values @ 0°C 25O, 100O, 500O temperature range Pt25, Pt100 -200°C … +850°C temperature range Pt500 -200°C … +500°C Accuracy with Pt25, Pt100 sensor ±0.03°C up to 350°C ±0.3°C up to 850°C Accuracy with Pt500 sensor ±0.5°C up to 500°C Resolution 0.01°C from -200°C to 350°C 0.1°C from 350°C to 800°C Temperature drift @20°C 0.002%/°C Excitation current 400µA impulse, length=100ms, time=1sTemperature measure for thermocouple with cold joint (inside ice at 0°C) TP471D0 Temperature measure for 1 input thermocouple TP471D1 Temperature measure for 2 input thermocouple VP472 module to connect pyranometers or albedometers. The measurements pro- duced during the time by a pyranometer or an albedometer can be taken, verified and stored. The signal produced by the thermopile can be read in mV or in W/m2, the net radiation of the albedometer is read in W/m2. The thermo- pile sensitivity can be set from 5000 to 30000nV/(Wm-2) that is between 5 and 30µV/(Wm-2). VP473 module for reading the continuous voltage. When connected to the output of a transmitter with voltage signal it can read and take the relevant value. Measur- ing range: ±20Vdc. Input impedance: 1MO. IP472 module for mA reading of continuous current. When connected to the output of a trasmitter with current signal, it can read and take the relevant value. Meas- uring range: 0…24mA. Input impedance: 25O. PP471 module for measuring absolute, relative and differential pressure. It can be con- nected with pressure probes andseries. It measure the instantaneous value and peak value of pressure. The module is complete with 2m cable and DIN 45326 8 pole female connector. Accuracy: ±0.05% of full scale Peak time = 5ms Peak accuracy: ±0.5% f.s. Peak dead band = 2% f.s. ProBes anD moDules TeChnICal DaTa eQuIPPeD WITh InsTrumenT Temperature probes Pt100 sensor using sICram module model Type applicationrange accuracy TP472I Immersion -196°C…+500°C ±0.25°C (-196°C…+350°C) ±0.4°C (+350°C…+500°C) TP472I.0 Immersion -50°C…+400°C ±0.25°C (-50°C…+350°C) ±0.4°C (+350°C…+400°C) TP473P Penetration -50°C…+400°C ±0.25°C (-50°C…+350°C) ±0.4°C (+350°C…+400°C) TP473P.0 Penetration -50°C…+400°C ±0.25°C (-50°C…+350°C) ±0.4°C (+350°C…+400°C) TP474C Contact -50°C…+400°C ±0.3°C (-50°C…+350°C)±0.4°C (+350°C…+400°C) TP474C.0 Contact -50°C…+400°C ±0.3°C (-50°C…+350°C)±0.4°C (+350°C…+400°C) TP475A.0 Air -50°C…+250°C ±0.3°C (-50°C…+250°C) TP472I.5 Immersion -50°C…+400°C ±0.3°C (-50°C…+350°C) ±0.4°C (+350°C…+400°C) TP472I.10 Immersion -50°C…+400°C ±0.30°C (-50°C…+350°C) ±0.4°C (+350°C…+400°C) TP49A Immersion -70°C…+400°C ±0.25°C (-50°C…+350°C) ±0.4°C (+350°C…+400°C) TP49AC Contact -70°C…+400°C ±0.25°C (-50°C…+350°C) ±0.4°C (+350°C…+400°C) TP49AP Penetration -70°C…+400°C ±0.25°C (-50°C…+350°C) ±0.4°C (+350°C…+400°C) TP875 Globe thermometer Ø 150mm -30°C…+120°C ±0.25°C TP876 Globe thermometer Ø 150mm -30°C…+120°C ±0.25°C TP87 Immersion -50°C…+200°C ±0.25°C TP878 TP878.1 For solar panel +5°C…+80°C ±0.25°C TP879 For compost -20°C…+120°C ±0.25°C Common characteristics Temperature drift @ 20°C 0.003%/°C 4 wire Pt100 and 2 wire Pt1000 Probes model Type application range accuracy TP47.100 Pt100 4 wires -50…+400°C Classe A TP47.1000 Pt1000 2 wires -50…+400°C Classe A Common characteristics Temperature drift @ 20°C Pt100 0.003%/°C Pt1000 0.005%/°C unCerTaInTY anD resoluTIon of The InsTrumenT In measurInG WITh ThermoCouPles Temperature measurement of the instrument Measuring range Tc: K -200…+1370°C Measuring range Tc: J -100…+750°C Measuring range Tc: T -200…+400°C Measuring range Tc: N -200…+1300°C Measuring range Tc: R +200…+1480°C Measuring range Tc: S +200…+1480°C Measuring range Tc: B +200…+1800°C Measuring range Tc: E -200…+750°C resolution 0.05°C up to 199.95°C 0.1°C from 200.0°C to end scale Instrument accuracy Thermocouple K ±0.1°C up to 600°C ±0.2°C above 600°C Thermocouple J ±0.05°C up to 400°C ±0.1°C above 400°C Thermocouple T ±0.1°C Thermocouple N ±0.1°C up to 600°C ±0.2°C above 600°C Thermocouple R ±0.25°C Thermocouple S ±0.3°C Thermocouple B ±0.35°C Thermocouple E ±0.1°C up to 300°C ±0.15°C above 300°C accuracy is referred to the instrument only, error due to the thermocouple or to the cold junction reference sensor is not included. Temperature drift @20°C 0.02%/°C Drift after 1 year 0.1°C/year Type K Thermocouple probes accuracy of the thermocouple probes The tolerance of a type of thermocouple corresponds to the maximum acceptable depar- ture from the e.m.f. of any thermocouple of that type, with reference junction at 0°C. The tolerance is expressed in degrees Celsius, preceded by the sign. The percentage tolerance is given by the ratio between the tolerance expressed in degrees Celsius and the meas- urement junction temperature, multiplied by one hundred. Tolerance classes for thermocouples (reference junction at 0°C) Type of Thermocouple Tolerance Class 1 Tolerance Class 2 Tolerance Class 3 (1) T Type Temperature interval Tolerance Temperature interval Tolerance from -40 to +125°C ± 0.5°C from 125 to 350°C ± 0.004 · ltr from -40 to +133°C ± 1°C from 133 to 350°C ± 0.0075 · ltr from -67 to +40°C ± 1°C from -200 to -67°C ± 0.015 · ltr e Type Temperature interval Tolerance Temperature interval Tolerance from -40 to +375°C ± 1.5°C from 375 to 800°C ± 0.004 · ltr from -40 to +333°C ± 2.5°C from 333 to 900°C ± 0.0075 · ltr from -167 to +40°C ± 2.5°C from -200 to -167°C ± 0.015 · ltr J Type Temperature interval Tolerance Temperature interval Tolerance from -40 to +375°C ± 1.5°C from 375 to 750°C ± 0.004 · ltr from -40 to +333°C ± 2.5°C from 333 to 750°C ± 0.0075 · ltr - - - - K Type, n Type Temperature interval Tolerance Temperature interval Tolerance from -40 to +375°C ± 1.5°C from 375 to 1000°C ± 0.004 · ltr from 40 to +333°C ± 2.5°C from 333 to 1200°C ± 0.0075 · ltr from -167 to +40°C ± 2.5°C from -200 to -167°C ± 0.015 · ltr r Type, s Type Temperature interval Tolerance Temperature interval Tolerance from 0 to +1100°C ± 1°C from 1100 to 1600°C ± [ 1 + 0.003 (t-1 100)] °C from 0 to +600°C ± 1.5°C from 600 to 1600°C ± 0.0025 · ltr - - - - B Type Temperature interval Tolerance Temperature interval Tolerance - - - - - - from 600 to 1700 °C ± 0.0025 · ltr from +600 to +800C + 4°C from 800 to 1700°C ± 0.005 · ltr (1) The materials used for thermocouples are generally supplied so to comply with the pro- duction tolerances specified in the table for temperatures over -40°C. Nevertheless, these materials may not comply with the production tolerances for low temperatures reported under Class 3, for T, E, K and N thermocouples when the thermocouples have to comply at the same time with the limits of Class 3 and those of Class 1 and/or Class 2. Ø 3 300 150 Ø 4 230 Ø 5 230 Ø 3 150 Ø 4 230 Ø 5 230 Ø 4 500 Ø 6 1000 Ø 6 244 Multifunction PT100 ProBes WITh sICram moDule for PorTaBle InsTrumenTs CoDe °C max t s DIMENSIONS use TP 472 I -196 +500 3s TP 473 P -50 +400 5s TP 474 C -50 +400 5s TP 472 I.0 -50 +400 3s TP 473 P.0 -50 +400 5s TP 474 C.0 -50 +400 5s TP 475 a.0 -50 +250 12s TP 472 I.5 -50 +400 3s TP 472 I.10 -50 +400 3s 150 Ø 2,7 Ø 4 150 150 Ø 2,7 70 Ø 3 230 Ø 3 21 40 Ø 8 Ø 21 1000 15 245 M ul tif un ct io n Multifunction PT100 ProBes WITh sICram moDule for PorTaBle InsTrumenTs CoDe °C max t s DIMENSIONS use TP 49 a -70 +400 3,5s TP 49 aC -70 +400 5,5s TP 49 aP -70 +400 4s TP 87 -50 +200 3s TP 878 +5 +80 60s Contact probe for solar panels. Cable L = 2m. TP 878.1 +5 +80 60s Contact probe for solar panels. Cable L = 5m. TP879 -20 +120 60s Penetration probe for compost. Cable L = 2m TP 875 -30 +120 15s Globe-thermometer probe for measuring radiant heat ø150 mm. (ISO7243, ISO7726). 4 wires Pt100 Sensor cable L=2m. equipped with sICram module. TP 876 -30 +120 15s Globe-thermometer probe for measuring radiant heat ø50 mm. (ISO7243, ISO7726). 4 wires Pt100 Sensor cable L=2m. equipped with sICram module. sonDe sensore Pt100 / Pt1000 Con moDulo TP 47 CoDe °C max t s DIMENSIONS use TP 47.100 (Pt100) TP 47.1000 (Pt1000) -50 +400 3s TP 47 Only connector for connection of probes without SICRAM module: direct 3 and 4 wires Pt100, 2 wires Pt1000. 180 Ø 1,5 90 Ø 1,5 230 Ø 1,5 180 Ø 2 90 Ø 2 230 Ø 2 180 Ø 3 180 Ø 4 246 Multifunction ThermoCouPle ProBes for PorTaBle InsTrumenTs ThermoCouPle K TYPe ProBes (Chromel - alumel) CoDe °C max t s DIMENSIONS use TP 741 800 2s TP 741/1 400 2s TP 741/2 800 2s TP 742 800 2s TP 742/1 400 2s TP 742/2 800 2s TP 743 800 3s TP 744 400 4s 180 1 Ø 5 110 Ø 12Ø 3 Ø 3 500 300 Ø 3 25 Ø 2 200 Ø 15 Ø 15 200 35 Ø 27 300 Ø 27 300 50 247 M ul tif un ct io n Multifunction ThermoCouPle K TYPe ProBes (Chromel - alumel) CoDe °C max t s DIMENSIONS use TP 745 500 5s TP 746 250 2s TP 750 1000 3s TP 750.0 800 3s TP 751 200 2s TP 754 500 2s TP 754/9 500 2s TP 755 800 2s TP 755/9 800 2s 80 22 Ø 1,2 Ø 1,6 Ø 4 150 Ø 4 90 500mm Ø 5 200 35 60 90 Ø 2 35 Ø 3 Ø 1 100 Ø 20 248 Multifunction ThermoCouPle K TYPe ProBes (Chromel - alumel) CoDe °C max t s DIMENSIONS use TP 756 200 2s TP 757 180 30s MAGNETIC PROBE FOR CONTACT MEASURE ON MAGNETIC METALLIC SURFACES TP 758 400 4s TP 758.1 400 4s TP 772 400 3s TP 774 250 2s TP 776 200 2s TP 777 200 3s 1m / 2m / 3m / 5m 1200 Ø 6 700 Ø 6 Ø 6 ÷ 25 70 Ø 1 40 Ø 3,5 40 Ø 4 500 Ø 2 40 Ø 4 1000 Ø 2 Ø 5 500 Ø 1 30 249 M ul tif un ct io n Multifunction ThermoCouPle K TYPe ProBes (Chromel - alumel) CoDe °C max t s DIMENSIONS use TP 647 TP 647/2 TP 647/3 TP 647/5 300 300 300 300 2s 2s 2s 2s SIT calibration up to 300°C. TP 651 1200 6s TP 652 1200 6s TP 655 180 2s TP 656 200 1s TP 656/1 1000 1s TP 656/2 1000 1s TP 657/1 100 5s TP 658 100 2s 150 Ø 3 150 Ø 4,5 85 40 L = 2m Cs Cm L = 2m 400 30 250 Multifunction ThermoCouPle K TYPe ProBes (Chromel - alumel) CoDe °C max t s DIMENSIONS use TP 659 400 3s TP 660 400 4s TP 661 -60 +50 30s TP 662 110 120s PROBE WITH VELCRO TAPE FOR MEASURES ON PIPES MAX 110 DIAM. Cm Cs “K” “K” PW “K” response time for a 63% variation (t0.63) The response time t s is the reaction time of the sensor to a temperature variation, with a signal variation when measuring that corresponds to a given percentage (63%) of the variation. Response time is referred: For immersion probes in water at 100°C For surface probes in contact with metals surface at 200°C For air probe at an air temperature of 100°C 170 Ø 26 170 Ø 26 130 120 Ø 14 130 215 Ø 14 110 560 Ø 14 110 520 18x4 480 Ø 14 130 Ø 14 251 M ul tif un ct io n Multifunction Temperature and relative humidity probes with sICram module model Temperaturesensor Campo d’impiego accuracy %rh Temperature %rh Temp hP472aCr Pt100 0…100%RH -20°C…+80°C ±2%RH (5…90%RH) ±2,5%RH (remaining range) ±0.3°C hP572aCr Thermocouple K 0…100%RH -20°C…+80°C ±0.5°C hP473aCr Pt100 0…100%RH -20°C…+80°C ±0.3°C hP474aCr Pt100 0…100%RH -40°C…+150°C -40°C…150°C (180°C) ±(1,5+0,02 times the displayed value) ±0.3°C hP475aCr Pt100 0…100%RH -40°C…+150°C ±0.3°C hP475aC1r Pt100 0…100%RH -40°C…+150°C ±0.3°C hP477DCr Pt100 0…100%RH -40°C…+150°C ±0.3°C hP478aCr Pt100 0…100%RH -40°C…+150°C ±0.3°C Common characteristics Relative Humidity Sensor Capacitive Typical capacity @30%RH 300pF Probe temperature working range -40°C…+150°C Working range 0 … 100%RH Accuracy ±1,5%RH (5…90%RH), ±2,5 remaining range Resolution 0.1%RH Temperature drift @20°C 0.02%RH/°C %RH response time at 10sec (10?80%RH; air speed=2m/s) constant temperature Temperature with Pt100 sensor Resolution 0.1°C Temperature drift @20°C 0.003%/°C Temperature with thermocouple K-HP572AC Resolution 0.1°C Temperature drift @20°C 0.02%/°C relaTIVe humIDITY anD TemPeraTure ProBes Code sensors rangerh - Temp. DImensIons hP472aCr RH Pt100 5 ÷ 98% RH -20°C…+80°ChP572aCr RH TC.K hP473aCr RH Pt100 hP474aCr 5 ÷ 98% RH -40°C…+150°C hP475aCr hP475aC1r hP477DCr hP478aCr hP475aC hP477DC hP474aC hP473aC hP472aC TP704… TP705… 252 Multifunction ProBes for Pressure measuremenT Probes complete with sICram module PP471: SICRAM module interface between instrument and pressure probes of the series TP704 and TP705. PP472: Barometric probe, measuring range 600…1100mbar. Resolution: 0.1mbar Accuracy @ 20°C: ±0.3mbar. Temperature range: -10 … +60°C PP473s1…s8: Differential pressure probes. Working range s1=f.s.10mbar, s2=f.s.20mbar, s3=f.s.50mbar, s4=f.s.100mbar, s5=f.s.200mbar, s6=f.s.500mbar, s7=f.s.1bar, s8=f.s.2bar Maximum overpressure s1,s2,s3=200mbar s4=300mbar s5,s6=1bar s7=3bar s8=6bar Accuracy @ 25°C ±0.5%f.s. (10, 20, 50mbar) ±0.25%f.s. (100mbar) ±0.12% f.s. (200, 500, 1000, 2000mbar) Temperature range -10 … +60°C Fluid in contact with the membrane non-corrosive dry gas or air Connection tube Ø 5mm Probes to couple to the module to measure the absolute, relative or differential pressure. TP704…/TP705…: Probes to connect to SICRAM module PP471 for measuring relative, absolute or differential pressure. Pressure ProBe TaBle Bottom scale pressure maximum overpressure resolution orDer CoDes accuracy from 20 to 25°C Working temperature ConnectionDifferential pressure relative pressure(compared to atmosphere) absolute pressure NON insulated membrane Insulated membrane Insulated membrane 10.0 mbar 20.0 mbar 0.01 mbar • TP705-10MBD 0.5 % FSO 0..60 °C Tube Ø 5 mm 20.0 mbar 40.0 mbar 0.01 mbar • TP705-20MBD 0.5 % FSO 0..60 °C Tube Ø 5 mm 50.0 mbar 100 mbar 0.01 mbar TP705-50mBD 0.5 % FSO 0..60 °C Tube Ø 5 mm 100 mbar 200 mbar 0.1 mbar TP705-100mBD 0.25 % FSO 0..60 °C Tube Ø 5 mm TP704-100mBGI 0.25 % FSO -10..+80 °C ¼ BSP 200 mbar 400 mbar 0.1 mbar TP705-200mBD 0.25 % FSO 0..60 °C Tube Ø 5 mm TP704-200mBGI 0.25 % FSO -10..+80 °C ¼ BSP 400 mbar 1000 mbar 0.1 mbar TP704-400mBGI 0.25 % FSO -10..+80 °C ¼ BSP 500 mbar 1000 mbar 0.1 mbar TP705-500mBD 0.25 % FSO 0..60 °C Tube Ø 5 mm 600 mbar 1000 mbar 0.1 mbar TP704-600mBGI 0.25 % FSO -40..125 °C ¼ BSP 1.00 bar 2.00 bar 1 mbar TP705-1BD 0.25 % FSO 0..60 °C Tube Ø 5 mm TP705Baro 0.25 % FSO 0..60 °C Tube Ø 5 mm 0.25 % FSO -40..125 °C ¼ BSP TP704-1Ba 0.25 % FSO -40..120 °C ¼ BSP 2.00 bar 4.00 bar 1 mbar TP705-2BD 0.25 % FSO 0..60 °C Tube Ø 5 mm TP704-2BGI 0.25 % FSO -40..+125 °C ¼ BSP TP704-2BaI * 0.25 % FSO -25..+85 °C ¼ BSP 5.00 bar 10.00 bar 1 mbar TP704-5BGI 0.25 % FSO -40..+125 °C ¼ BSP TP704-5BaI * 0.25 % FSO -25..+85 °C ¼ BSP 10.00 bar 20.0 bar 0.01 bar TP704-10BGI 0.25 % FSO -40..+125 °C ¼ BSP TP704-10BaI * 0.25 % FSO -25..+85 °C ¼ BSP 20.0 bar 40.0 bar 0.01 bar TP704-20BGI 0.25 % FSO -40..+125 °C ¼ BSP TP704-20BaI * 0.25 % FSO -25..+85 °C ¼ BSP 50.0 bar 100.0 bar 0.01 bar TP704-50BGI 0.25 % FSO -40..+125 °C ¼ BSP TP704-50BaI * 0.25 % FSO -25..+85 °C ¼ BSP 100 bar 200 bar 0.1 mbar TP704-100BGI 0.25 % FSO -40..+125 °C ¼ BSP TP704-100BaI * 0.25 % FSO -25..+85 °C ¼ BSP 200 bar 400 bar 0.1 mbar TP704-200BGI 0.25 % FSO -40..+125 °C ¼ BSP TP704-200BaI * 0.25 % FSO -25..+85 °C ¼ BSP 500 bar 1000 bar 0.1 mbar TP704-500BGI 0.25 % FSO -40..+125 °C ¼ BSP 700 bar 0.1 mbar TP704-500BaI * 0.25 % FSO -25..+85 °C ¼ BSP * Ceramic diaphragm • Only report of calibration, no SIT certificate T4... T3... T3... T2... T2... T1... aP472s1… aP472s2… aP472s4… aP471s3 aP471s2 aP471s1 253 M ul tif un ct io n Multifunction ProBes anD moDules TeChnICal DaTa eQuIPPeD WITh InsTrumenT Wind speed measurement probes hot-wire probes: aP471 s1 - aP471 s2 - aP471 s3 - aP471 s4 aP471 s1 - aP471 s3 aP471 s2 aP471 s4 Type of measure Air speed, calculated flow rate, air temperature Type of sensor Speed NTC thermistor Omnidirectional NTC thermistor Temperature NTC thermistor NTC thermistor Measurement range Speed 0,1…40m/s 0,1…5m/s Temperature -25…+80°C -25…+80°C 0…80°C Measurement resolution: Speed 0.01 m/s 0.1 km/h 1 ft/min 0.1 mph 0.1 knot Temperature 0.1°C Measurement accuracy: Speed ±0.1 m/s (0…0.99 m/s) ±0.05m/s (0…0.99 m/s) ±0.3 m/s (1.00…9.99 m/s) ±0.15m/s (1.00…5.00 m/s) ±0.8 m/s (10.00…40.0 m/s) Temperature ±0.8°C (-10…+80°C) ±0.8°C (-10…+80°C) Minimum speed 0.1 m/s Air temperature compensation 0…80°C Sensor working conditions Clean air, RH<80% Battery life Approx. 20 hours @ 20 m/s with alkaline batteries Approx. 30 hours @ 5 m/s with alka- line batteries Unit of Measurement Speed m/s – km/h – ft/min – mph – knot Flow rate l/s - m3/s - m3/min - m3/h - ft3/s - ft3/min Pipeline section for flow rate calculation 0.0001…1.9999 m 2 Cable length ~2m Vane probes: aP472 s1… - aP472 s2 - aP472 s4… aP472 s1… aP472 s2 aP472 s4… l lT h hT Type of measure Air speed, calculated flow rate, air temperature Air speed, calculated flow rate Air speed, calculated flow rate. Air speed, calculated flow rate, air tempera- ture. Air speed, calculated flow rate. Air speed, calculated flow rate, air tempera- ture. Diameter 100mm 60mm 16mm Type of measurement Speed Vane Vane Vane Temperature K thermocouple ---- ---- K thermocouple ---- K thermo couple Measurement range Speed (m/s) 0.6…25 0.5…20 0.8…20 10…40 Temperature (°C) -25…+80 (*) -25...+80 (*) Resolution Speed 0.01 m/s 0.1 km/h 1 ft/min 0.1 mph 0.1 knot Temperature 0.1°C ---- ---- 0.1°C ---- 0.1°C Accuracy Speed ±(0.3 m/s +1.5%f.s.) ±(0.3m/s +1.5%f.s.) ±(0.4 m/s +1.5%f.s.) Temperature ±0.8°C ---- ---- ±0.8°C ---- ±0.8°C Minimum speed 0.6m/s 0.5m/s 0.8m/s 10m/s Unit of Measurement Speed m/s – km/h – ft/min – mph – knot Flow rate l/s - m3/s - m3/min - m3/h - ft3/s - ft3/min Pipeline section for flow rate calculation 0.0001…1.9999 m 2 Cable length ~2m (*) The indicated value refers to the vane’s working range. lP471lum2 lP471PhoT lP471raD lP471Par lP471uVa lP471uVB lP471uVC aP471s4 254 Multifunction Pitot tube probes: aP473 s1 - aP473 s2 - aP473 s3 - aP473 s4 aP473 s1 aP473 s2 aP473 s3 aP473 s4 Kind of measurement Air speed, calculated flow, differential pressure, Air temperature Working range Diff. pressure 10 mbar f.s. 20mbar f.s. 50mbar f.s. 100mbar f.s. Speed (*) 2 … 40m/s 2 … 55m/s 2 … 90m/s 2 … 130m/s Temperature -200…+600°C -200…+600°C -200…+600°C -200…+600°C Resolution Speed m/s 0.1 km/h 1 ft/min 1.103 mph 1 Knots 1 Temperature 0.1°C Accuracy Speed ±0.4%f.s. of pressure ±0.3%f.s. of pressure Temperature ±0.8°C ±0.8°C Minimum speed 2 m/s Air temperature compensation -200…+600°C (if K thermocouple is connected to the module) Unit of measurement Speed m/s - km/h - ft/min - mph - Knots Flow rate l/s - m3/h - m3/min - ft3/s - ft3/min Duct section for flow calculation .001…1.999 m 2 (*) A 20°C, 1013mbar and Ps negligible. PhoTomeTrIC anD raDIomeTrIC ProBes Technical characteristics of photometric and radiometric probes complete with sICram module equipped with the instruments IllumInanCe measurement probe lP 471 PhoT Measurement range (lux): 0.01…199.99 …1999.9 …19999 …199.99·103 Resolution (lux): 0.01 0.1 1 0.01·103 Spectral range: in agreement with standard photopic curve V(?) Class C (B on request) Calibration uncertainty: <4% f’1 (in agreement with photopic response V(?)): <8% f2 (response according to the cosine law): <3% f3 (linearity): <1% f4 (instrument reading error): <0.5% f5 (fatigue): <0.5% a (temp. coefficient) f6 (T) <0.05%K Drift after 1 year: <1% Functioning temperature: 0…50°C Reference Standards CIE n.69 - UNI 11142 Photometric probe for IllumInanCe measurement, spectral response in agreement with standard photopic vision, diffuser for cosine correction. Measurement range: 0.01 lux…200·103 lux. 0 0,1 0,2 0,3 0,4 0,5 0,6 0,7 0,8 0,9 1 380 430 480 530 580 630 680 730 780 830 ? (nm) 0 0,1 0,2 0,3 0,4 0,5 0,6 0,7 0,8 0,9 1 350 450 550 650 750 850 950 1050 ? (nm) 0 0,1 0,2 0,3 0,4 0,5 0,6 0,7 350 400 450 500 550 600 650 700 750 800 850 Re la tiv e sp ec tra l r es po ns e PAR ? (nm) 0 0,1 0,2 0,3 0,4 0,5 0,6 0,7 0,8 0,9 1 280 300 320 340 360 380 400 420 ? (nm) 255 M ul tif un ct io n Multifunction lumInanCe measurement probe lP 471 lum 2 Measurement range (cd/m2): 0.1…1999.9 …19999 …199.99·103 …1999.9·103 Resolution (cd/m2): 0.1 1 0.01·103 0.1·103 Optical angle: 2° Spectral range: in agreement with standard photopic curve V(?) Class C Calibration uncertainty: <5% f’1 (in agreement with photopic response V(?)): <8% f3 (linearity): <1% f4 (instrument reading error): <0.5% f5 (fatigue): <0.5% a (temp. coefficient) f6 (T) <0.05%K Drift after 1 year: <1% Functioning temperature: 0…50°C Reference Standards CIE n.69 - UNI 11142 Photometric probe for lumInanCe measurement, spectral response in agreement with standard photopic vision, vision angle 2°. Measurement range: 0.1 cd/m2…2000·103 cd/m2. Typical response curve: LP 471 PHOT and LP471 LUM 2 Quantum radiometric probe for the measurement of the photon flow across the chlorophyll range Par lP 471 Par Measurement range (µmolm-2s-1): 0.01… 199.99 200.0…1999.9 2000…10000 Resolution (µmolm-2s-1): 0.01 0.1 1 Spectral range: 400nm…700nm Calibration uncertainty: <5% f’ 1 (response according to the cosine law): <6% f 3 (linearity): <1% f 4 (instrument reading error): ±1digit f5 (fatigue): <0.5% Drift after 1 year: <1% Working temperature: 0…50°C Quantum radiometric probe for the measurement of the photon flow across the chlorophyll range Par (Photosynthetically Active Radiation 400nm…700nm), measurement in µmol/m2s. Measurement range: 0.01µmol/m-2s-1…10·103µmol/m-2s-1. Typical response curve: LP 471 PAR IrraDIanCe measurement probe lP 471 raD Measurement range (W/m2): 0.1·10 -3 … 999.9·10-3 1.000 …19.999 20.00 …199.99 200.0 …1999.9 Resolution (W/m2): 0.1·10-3 0.001 0.01 0.1 Spectral range: 400nm…1050nm Calibration uncertainty: <5% f’ 1 (response according to the cosine law): <6% f3 (linearity): <1% f 4 (instrument reading error): ±1digit f 5 (fatigue): <0.5% Drift after 1 year: <1% Working temperature: 0…50°C Radiometric probe for IrraDIanCe measurement in the spectral range 400nm…1050nm, diffuser for cosine correction. Measurement range: 0.1·10-3W/m2 …2000 W/m2. Typical response curve: LP 471 RAD IrraDIanCe measurement probe lP 471 uVa Measurement range (W/m2): 0.1·10 -3 … 999.9·10-3 1.000 …19.999 20.00 …199.99 200.0 …1999.9 Resolution (W/m2): 0.1·10-3 0.001 0.01 0.1 Spectral range: 315nm…400nm (Peak 360nm) Calibration uncertainty: <5% f’ 1 (response according to the cosine law): <6% f3 (linearity): <1% f 4 (instrument reading error): ±1digit f 5 (fatigue): <0.5% Drift after 1 year: <2% Working temperature: 0…50°C Radiometric probe for IrraDIanCe measurement, in the 315nm…400nm, peak 360nm, uVa spectral range. Measurement range: 0.1·10-3W/m2…2000 W/m2. Typical response curve: LP 471 UVA Ri sp os ta s pe ttr al e re la tiv a Ri sp os ta s pe ttr al e re la tiv a Ri sp os ta s pe ttr al e re la tiv a Ri sp os ta s pe ttr al e re la tiv a 0 0,1 0,2 0,3 0,4 0,5 0,6 0,7 0,8 0,9 1 250 260 270 280 290 300 310 320 330 340 350 ? (nm) 0,00001 0,0001 0,001 0,01 0,1 1 10 250 270 290 310 330 350 370 390 ? (nm) 0 0,1 0,2 0,3 0,4 0,5 0,6 0,7 0,8 0,9 1 200 210 220 230 240 250 260 270 280 290 300 ? (nm) 256 Multifunction IrraDIanCe measurement probe lP 471 uVB Measurement range (W/m2): 0.1·10 -3 … 999.9·10-3 1.000 …19.999 20.00 …199.99 200.0 …1999.9 Resolution (W/m2): 0.1·10-3 0.001 0.01 0.1 Spectral range: 280nm…315nm (Peak 305nm) Calibration uncertainty: <5% f’ 1 (response according to the cosine law): <6% f3 (linearity): <2% f4 (instrument reading error): ±1digit f 5 (fatigue): <0.5% Drift after 1 year: <2% Working temperature: 0…50°C Radiometric probe for IrraDIanCe measurement, in the spectral range 280nm…315nm, peak 305nm, uVB. Measurement range: 0.1·10-3W/m2…2000 W/m2. Typical response curve: LP 471 UVB IrraDIanCe measurement probe lP 471 uVC Measurement range (W/m2): 0.1·10 -3 … 999.9·10-3 1.000 …19.999 20.00 …199.99 200.0 …1999.9 Resolution (W/m2): 0.1·10-3 0.001 0.01 0.1 Spectral range: 220nm…280nm (Peak 260nm) Calibration uncertainty: <5% f’1 (response according to the cosine law): <6% f3 (linearity): <1% f4 (instrument reading error): ±1digit f5 (fatigue): <0.5% Drift after 1 year: <2% Working temperature: 0…50°C Radiometric probe for IrraDIanCe measurement, in the spectral range 220nm…280nm, peak 260nm, uVC. Measurement range: 0.1·10-3W/m2…2000 W/m2. Typical response curve: LP 471 UVC measurement probe lP 471erY of ToTal effeCTIVe IrraDIanCe (W/m2) according to the uV action curve uV (CeI en 60335-2-27) Measurement range (Weff /m 2): 0.1·10 -3 … 999.9·10-3 1.000 …19.999 20.00 …199.99 200.0 …1999.9 Resolution (Weff /m 2): 0.1·10-3 0.001 0.01 0.1 Spectral range: UV action curve for erythema measurement (250nm…400nm) Calibration uncertainty: <15% f 3 (linearity): <3% f 4 (instrument reading error ±1digit f5 (fatigue): <0.5% Drift after 1 year <2% Working temperature: 0…50°C Reference standard CEI EN 60335-2-27 Radiometric probe for effeCTIVe ToTal IrraDIanCe (W eff /m 2) according to the UV action curve (CIE EN 60335-2-27). Spectral range: 250 nm…400 nm, Measurement range: 0.1·10-3Weff /m 2 … 2000 Weff /m 2 Typical response curve. TOTAL EFFECTIVE IRRADIANCE LP 471 ERY Ri sp os ta s pe ttr al e re la tiv a Ri sp os ta s pe ttr al e re la tiv a Ri sp os ta s pe ttr al e re la tiv a Solid line = Action curve Dashed line = Spectral sensitivity LP471ERY probe The probe LP 471 ERY measures the total effective irradiance (Weff/m 2) according to the UV action curve (CEI EN 60335-2-27). A particular type of photodiode and a combination of special filters bring the spectral response closer to the UV action curve. CEI EN 60335-2-27 standards estabilish a maximum allowable dose of 100J/m2 for first- time exposure and an annual dose of 15000J/m2. The typical spectral response curve of LP 471 ERY is shown in the Figure together with the UV action curve. The good accordance between the two curves enables the instrument to take reliable measurements of different types of lamps (and filters) used at present for tanning machines. Each probe is individually calibrated at DeltaOhm photo-radiometry laboratory by means of a double monochrome. Calibration is performed at 290 nm through a sIT calibra- ted reference photodiode. PP473-s... aP473-s3 PP472 257 M ul tif un ct io n Multifunction orDerInG CoDes Do 9847K: The kit is provided with multifunctional instrument, 9CPRS232 serial output cable, 4 1.5V alkaline batteries, instruction manual and carrying case. modules and probes have to be ordered separately . 9CPrs232: Female/female sub D 9 pole extension cable for RS232C (null modem). Deltalog3: Software for downloading and PC data management. TP471: Measures the temperature with PRT Platinum sensors Resistance values of the PRT @ 0°C 25O, 100O, 500O Measuring range Pt25, Pt100 -200°C…+850°C Measuring range Pt500 -200°C…+500°C Accuracy with Pt25, Pt100 sensor ±0.03°C till 350°C ±0.3°C till 500°C Accuracy with Pt500 sensor ±0.5°C till 500°C Resolution 0.01°C from -200°C till 350°C 0.1°C from 350°C till 850°C Temperature drift @20°C 0.02%/°C Excitation current 400µA impulse, length=100ms, time=1s TP471D0: Measures the temperature with thermocouple, cold junction at 0°C inside ice. TP471D: Measures the temperature with thermocouple, 1 input TP741D1: Measures the temperature with thermocouple, 2 inputs VP472: Module for connecting pyranometers or albedometers. For acquisition, verifica- tion, and storage of the values generated by a pyranometer or albedometer. The generated value can be read in mV or in W/m², the net radioation of the albedometer is read in W/m². The sensitivity can be set between 5000 and 30000nV/(W/m²), or rather between 5 and 30µV/(W/m²). VP473: Module for reading continuous voltage. Reads and acquires values when con- nected to a transmitter with voltage signal. Measuring range ±20Vdc. Input imped- ance: 1MO. IP472: Module for reading continuous current. Reads and acquires current values when connected to a transmitter with current output. Measuring range 0…24mA Input impedance: 25O. PP471: Module for the measurement of absolute, relative, and differential pressure. Works with pressure probes of the series TP704 and TP705. Provides instanta- neous value and pressure peak value. Includes cable L=2 and 8-pole DIN 45326 female connector. Accuracy: ±0.05% of f.s. Peak time: = 5ms Accuracy of the peak: ±0.5% f.s Peak dead band: = 2% f.s. Probes complete with sICram module TemPeraTure measuremenT ProBes TP472I: Immersion probe, sensor Pt100. Stem Ø 3 mm, length 300 mm. Cable length 2 metres. TP472I.0: Immersion probe, sensor Pt100. Stem Ø 3 mm, length 230 mm. Cable length 2 metres. TP473P: Penetration probe, sensor Pt100. Stem Ø 4mm, length 150 mm. Cable length 2 metres. TP473P.0: Penetration probe, sensor Pt100. Stem Ø 4mm, length 150 mm. Cable length 2 metres. TP474C: Contact probe, sensor Pt100. Stem Ø 4mm, length 230mm, contact surface Ø 5mm. Cable length 2 metres. TP474C.0: Contact probe, sensor Pt100. Stem Ø 4mm, length 230mm, contact surface Ø 5mm. Cable length 2 metres. TP475a.0: Air probe, sensor Pt100. Stem Ø 4mm, length 230mm. Cable length 2 metres. TP472I.5: Immersion probe, sensor Pt100. Stem Ø 6mm, length 500 mm. Cable length 2 metres. TP472I.10: Immersion probe, sensor Pt100. Stem Ø 6mm, length 1,000mm. Cable length 2 metres. TP49a: Immersion probe, Pt100 sensor. Stem Ø 2.7 mm, Length 150 mm. Cable 2 meters long. Aluminium handle. TP49aC: Contact probe, Pt100 sensor. Stem Ø 4 mm, Length 150 mm. Cable 2 meters long. Aluminium handle. TP49aP: Penetration probe, Pt100 sensor. Stem Ø 2.7 mm, Length 150 mm. Cable 2 meters long. Aluminium handle. TP875: Globe thermometer Ø 150 mm with handle. Cable 2 metres TP876: Globe thermometer Ø 50 mm with handle. Cable 2 metres. TP87: Immersion probe, Pt100 sensor. Stem Ø 3 mm, lenght 70 mm. Cable 2 metres. TP878: Contact probe for solar panels. Cable 2 metres. TP878.1: Contact probe for solar panels. Cable 5 metres. TP879: Penetration probe for compost. Stem Ø 8 mm, Length 1 m. Cable 2 meters. Temperature probes without sICram module TP47.100: Immersion probe, 4 wire direct Pt100 sensor. Stem Ø 3mm, length 230mm. 4 wire connecting cable with connector, length 2 metres. TP47.1000: Immersion probe, 4 wire direct Pt1000 sensor. Stem Ø 3mm, length 230mm. 4 wire connecting cable with connector, length 2 metres. TP47: Connector for probes connection: 4 wire direct Pt100. T3-800TC PW aP471s2 aP471s1 258 Multifunction relative humidity and temperature probes complete with sICram module hP472aCr: %RH and temperature combined probe, dimensions Ø 26x170 mm. 2 m connecting cable. hP572aCr: %RH and temperature combined probe, K thermocouple sensor. Dimen- sions Ø 26x170 mm. 2 m connecting cable. hP473aCr: %RH and temperature combined probe. Dimensions: handle Ø 26x130 mm, probe Ø 14x110 mm. 2m connecting cable. hP474aCr: %RH and temperature combined probe. Dimensions: handle Ø 26x130 mm, probe Ø 14x210 mm. 2m connecting cable. hP475aCr: %RH and temperature combined probe. 2 m connecting cable. Handle Ø 26x110 mm. Stainless-steel tube Ø 12x560 mm. Terminal tip Ø 13.5x75 mm. hP475aC1r: %RH and temperature combined probe. 2 m connection cable. Handle Ø 26x110 mm. Stainless steel stern Ø 14x480 mm. hP477DCr: %RH and temperature combined sword probe. 2 m connecting cable. Handle Ø 26x110 mm. Probe tube 18x4 mm, length 520 mm. hP478aCr: %RH and temperature combined probe. Dimensions Ø 14x130 mm. 5m con- nection cable. ProBes for Pressure measuremenT Probes complete with sICram module PP471: SICRAM module interface between instrument and pressure probes of the series TP704 and TP705. PP472: Barometric probe, measuring range 600…1100mbar. Resolution: 0.1mbar Accuracy @ 20°C: ±0.3mbar. Temperature range: -10 … +60°C PP473s1…s8: Differential pressure probes. Working range s1=f.s.10mbar, s2=f.s.20mbar, s3=f.s.50mbar, s4=f.s.100mbar, s5=f.s.200mbar, s6=f.s.500mbar, s7=f.s.1bar, s8=f.s.2bar Maximum overpressure s1,s2,s3=200mbar s4=300mbar s5,s6=1bar s7=3bar s8=6bar Accuracy @ 25°C ±0.5%f.s. (10, 20, 50mbar) ±0.25%f.s. (100mbar) ±0.12% f.s. (200, 500, 1000, 2000mbar) Temperature range -10 … +60°C Fluid in contact with the membrane non-corrosive dry gas or air Connection tube Ø 5mm Probes to couple to the module to measure the absolute, relative or differential pressure. TP704…/TP705…: Probes to connect to SICRAM module PP471 for measuring relative, absolute or differential pressure. ProBes for aIr sPeeD measuremenTs Probes equipped with sICram modules hoT-WIre ProBes aP471 s1: Hot-wire telescopic probe, measuring range: 0.1…40m/s. aP471 s2: Omni-directional hot-wire probe, measuring range: 0.1…5m/s. aP471 s3: Hot-wire telescopic probe with terminal tip for easy position, measuring range: 0.1…40m/s. aP471 s4: Omnidirectional hot-wire telescopic probe with base, measuring range: 0.1…5m/s. Cable length 2 metres. Vane probes: aP472 s1: Vane probe with thermocouple, Ø 100mm. Speed from 0.6 to 25m/s; tem- perature from -25 to 80°C. Cable length 2 metres. aP472 s2: Vane probe, Ø 60mm. Measurement range: 0.5…20m/s. Cable length 2 metres. aP472 s4l: Vane probe, Ø 16mm. speed from 0.8 to 20m/s. Cable length 2 metres. aP472 s4lT: Vane probe with thermocouple, Ø 16mm, speed from 0.8 to 20m/s. Tem- perature from -25 to 80°C with thermocouple K sensor(*). Cable length 2 metres. aP472 s4h: Vane probe, Ø 16mm speed from 10 to 40m/s. Cable length 2 metres. aP472 s4hT: Vane probe with thermocouple, Ø 16mm speed from 10 to 40m/s. Tem- perature from -25 to 80°C with thermocouple K sensor(*). Cable length 2 metres. moDules for PIToT TuBes aP473 s1: Pitot tube probe, differential pressure 10mbar f.s. Air speed from 2 to 40m/s. The Pitot tube has to be ordered separately. aP473 s2: Pitot tube probe, differential pressure 20mbar f.s. Air speed from 2 to 55m/s. The Pitot tube has to be ordered separately. aP473 s3: Pitot tube probe, differential pressure 50mbar f.s. Air speed from 2 to 90m/s. The Pitot tube has to be ordered separately. aP473 s4: Pitot tube probe, differential pressure 100mbar f.s. Air speed from 2 to 130m/s. The Pitot tube has to be ordered separately. PW: Connection cable between AP473S… module and Pitot tube. lP Bl aP472s1 aP471s1 259 M ul tif un ct io n Multifunction PIToT TuBes Stainless steel Pitot tubes to measure air speed and temperature for models provided with ‘K’ thermocouple. They can be connected to the SICRAM modules AP473S1, AP473S2, AP473S3 and AP473S4 d1 d L L1 L 2 D d mm d1 mm D mm l mm l1 mm l2 mm Temp.°C Thermo- couple K material T1-300 3 1 6 300 30 72 0…600°C --- AISI 316 T2-400 5 2 8 400 45 120 --- T2-600 5 2 8 600 45 120 --- T3-500 8 3.2 8 500 --- 192 --- T3-800 8 3.2 8 800 --- 192 --- T3-800TC 8 3.2 8 800 --- 192 TC T4-500 10 4.0 10 500 --- 240 --- T4-800 10 4.0 10 800 --- 240 --- T4-800TC 10 4.0 10 800 --- 240 TC T4-1000 10 4.0 10 1000 --- 240 --- T4-1000TC 10 4.0 10 1000 --- 240 TC ProBes for lIGhT measuremenT Probes complete with sICram module lP 471 PhoT: Photometric probe for IllumInanCe measurement complete with SICRAM module, spectral response in agreement with standard photopic vision, diffuser for cosine correction. Measurement range: 0.01 lux…200·103 lux. lP 471 lum 2: Photometric probe for lumInanCe measurement complete with SICRAM module, spectral response in agreement with standard photopic vision, vision angle 2°. Measurement range: 0.1 cd/m2…2000·103 cd/m2. lP 471 Par: Quantum radiometric probe for the measurement of the photon flow across the chlorophyll range Par (Photosynthetically Active Radiation 400nm…700nm) complete with SICRAM, measurement in µmol/m2s, diffuser for cosine correction. Measurement range: 0.01µmol/m2s…10·103µmol/m2s. lP 471 raD: Radiometric probe for IrraDIanCe measurement complete with SICRAM module; in the 400nm…1050nm spectral range, diffuser for cosine correction. Measurement range: 0.1·10-3W/m2 …2000 W/m2. lP 471 uVa: Radiometric probe for IrraDIanCe measurement complete with SICRAM module; in the 315nm…400nm, peak 360nm, uVa spectral range, quartz diffuser for cosine correction. Measurement range: 0.1·10-3W/m2…2000 W/m2. lP 471 uVB: Radiometric probe for IrraDIanCe measurement complete with SICRAM module, in the 280nm…315nm, peak 305nm, uVB spectral range, quartz diffuser for cosine correction. Measurement range: 0.1·10-3W/m2…2000 W/m2. lP 471 uVC: Radiometric probe for IrraDIanCe measurement complete with SICRAM module, in the 220nm…280nm, peak 260nm, uVC spectral range, quartz diffuser for cosine correction. Measurement range: 0.1·10-3W/m2…2000 W/m2. lP 471 erY: Radiometric probe for ToTal effeCTIVe IrraDIanCe (Weff/m 2) according to the UV action curve (CEI EN 60335-2-27) complete with SICRAM module. Spec- tral range: 250 nm…400 nm, quartz diffuser for cosine correction. Measurement range: 0.1·10-3Weff /m 2 … 2000 Weff /m 2. lP Bl: Base with levelling device for the probes (except LP 471 LUM2). lP 471 lum 2
Most popular related searches

Contact supplier

Drop file here or browse