Senseca Italy S.r.l.
Multifunction Meter
DO 9847
TP471D1
TP471D
TP471D0
TP471
TP472I
TP474C
TP473P
242 Multifunction
Is a multifunctional handheld board instrument and datalogger.
It is provided with a 128x64 pixel (56x38 mm) graphic display and three
independent inputs. Each input can be connected to one channel or two channel dual
probes (ex. two thermocouples, relative humidity/temperature, etc.).
The instrument automatically recognises SICRAM probes connected to the input (memory
equipped and configurable intelligent probe).
Functions: watch, hold, max., min., average, record, immediate or deferred start record
logging, difference between the two inputs, relative measures, three input channel meas-
urement and inside reference temperature display.
Sampling time: one per second/input.
Probe calibration through SICRAM module; calibration data permanent storage inside
the probe.
Storage capacity: 32.000 readings per input.
Storage interval and printing can be configured between one second and 1 hour.
RS232C serial output: from 300 up to 115.200 baud rate.
Immediate or deferred print-out.
Stored data can be displayed and stored data blocks can be deleted.
Automatic shutout after 8 minutes can be disabled.
Units of measurement can be selected according to the physical quantity of the con-
nected probe.
Firmware update through RS232C serial port. Different types of SICRAM modules or
probes can be connected to the input: Platinum sensor temperature, thermocouple,
relative humidity/temperature, Discomfort index, continuous voltage (±20V), current
(0…24mA), pressure, air speed and light.
TeChnICal DaTa of The InsTrumenT Do9847
- Power supply:
Battery: 4 1.5V AA alkaline batteries; operating time with high quality batteries: about
60 hours.
Mains: through 9Vdc, 250mA external power supply, 2 pole connector.
- Operating conditions:
Working temperature: -10...+50°C. Storage temperature: -25...+65°C.
Relative Humidity: 0...90%R.H., not condensating.
- LCD display: 128x64 pixel (56x38 mm) graphic LCD.
- Keyboard: 18 multifuction Keys and 3 function keys.
- Recorded data safety: independently from batteries charging conditions.
- Measured values storage: on 16 files divided into 16-sample pages.
- Quantity: 32.000 samples per input channel.
- Storage interval: 1 s...1 h. Time and date, real time.
Accuracy: 1 minute/month maximum error margin.
- Serial interface:
RS232C type galvanically insulated SUB D 9 male connector.
Baud rate: 300...115.200 baud. Data bit: 8.
Parity: none. Stop bit: 1.
Flow control: Xon/Xoff. RS232C cable max.length: 15 m.
- immediate printing interval: 1 s...1 h.
- Firmware can be updated through PC using the instrument serial port.
- Probes connections: n° 3 DIN45326 8 pole connectors
- Dimensions and weight: 245x100x50 mm - 300 gr.
- Case: ABS - Protection: rubber.
Do 9847 - CharaCTerIsTICs of The sICram moDules
When the instrument is used together with the available sICram modules, its accu-
racy and resolution are stated in the section where these modules are described.
Do 9847
PorTaBle mulTIfunCTIon DaTa-loGGer InsTrumenT
243
M
ul
tif
un
ct
io
n
Multifunction
sICram moDules for Do 9847
TP471 Temperature measure through PRT Platinum sensor
PRT resistance values @ 0°C 25O, 100O, 500O
temperature range Pt25, Pt100 -200°C … +850°C
temperature range Pt500 -200°C … +500°C
Accuracy with Pt25, Pt100 sensor ±0.03°C up to 350°C
±0.3°C up to 850°C
Accuracy with Pt500 sensor ±0.5°C up to 500°C
Resolution 0.01°C from -200°C to 350°C
0.1°C from 350°C to 800°C
Temperature drift @20°C 0.002%/°C
Excitation current 400µA impulse, length=100ms,
time=1sTemperature measure for thermocouple with cold joint (inside ice at 0°C)
TP471D0 Temperature measure for 1 input thermocouple
TP471D1 Temperature measure for 2 input thermocouple
VP472 module to connect pyranometers or albedometers. The measurements pro-
duced during the time by a pyranometer or an albedometer can be taken,
verified and stored. The signal produced by the thermopile can be read in mV
or in W/m2, the net radiation of the albedometer is read in W/m2. The thermo-
pile sensitivity can be set from 5000 to 30000nV/(Wm-2) that is between 5 and
30µV/(Wm-2).
VP473 module for reading the continuous voltage. When connected to the output of a
transmitter with voltage signal it can read and take the relevant value. Measur-
ing range: ±20Vdc. Input impedance: 1MO.
IP472 module for mA reading of continuous current. When connected to the output of
a trasmitter with current signal, it can read and take the relevant value. Meas-
uring range: 0…24mA. Input impedance: 25O.
PP471 module for measuring absolute, relative and differential pressure. It can be con-
nected with pressure probes andseries. It measure the instantaneous value and
peak value of pressure. The module is complete with 2m cable and DIN 45326
8 pole female connector.
Accuracy: ±0.05% of full scale Peak time = 5ms
Peak accuracy: ±0.5% f.s. Peak dead band = 2% f.s.
ProBes anD moDules TeChnICal DaTa eQuIPPeD WITh InsTrumenT
Temperature probes Pt100 sensor using sICram module
model Type applicationrange accuracy
TP472I Immersion -196°C…+500°C ±0.25°C (-196°C…+350°C) ±0.4°C (+350°C…+500°C)
TP472I.0 Immersion -50°C…+400°C ±0.25°C (-50°C…+350°C) ±0.4°C (+350°C…+400°C)
TP473P Penetration -50°C…+400°C ±0.25°C (-50°C…+350°C) ±0.4°C (+350°C…+400°C)
TP473P.0 Penetration -50°C…+400°C ±0.25°C (-50°C…+350°C) ±0.4°C (+350°C…+400°C)
TP474C Contact -50°C…+400°C ±0.3°C (-50°C…+350°C)±0.4°C (+350°C…+400°C)
TP474C.0 Contact -50°C…+400°C ±0.3°C (-50°C…+350°C)±0.4°C (+350°C…+400°C)
TP475A.0 Air -50°C…+250°C ±0.3°C (-50°C…+250°C)
TP472I.5 Immersion -50°C…+400°C ±0.3°C (-50°C…+350°C) ±0.4°C (+350°C…+400°C)
TP472I.10 Immersion -50°C…+400°C ±0.30°C (-50°C…+350°C) ±0.4°C (+350°C…+400°C)
TP49A Immersion -70°C…+400°C ±0.25°C (-50°C…+350°C) ±0.4°C (+350°C…+400°C)
TP49AC Contact -70°C…+400°C ±0.25°C (-50°C…+350°C) ±0.4°C (+350°C…+400°C)
TP49AP Penetration -70°C…+400°C ±0.25°C (-50°C…+350°C) ±0.4°C (+350°C…+400°C)
TP875 Globe thermometer Ø 150mm -30°C…+120°C ±0.25°C
TP876 Globe thermometer Ø 150mm -30°C…+120°C ±0.25°C
TP87 Immersion -50°C…+200°C ±0.25°C
TP878
TP878.1 For solar panel +5°C…+80°C ±0.25°C
TP879 For compost -20°C…+120°C ±0.25°C
Common characteristics
Temperature drift @ 20°C 0.003%/°C
4 wire Pt100 and 2 wire Pt1000 Probes
model Type application range accuracy
TP47.100 Pt100 4 wires -50…+400°C Classe A
TP47.1000 Pt1000 2 wires -50…+400°C Classe A
Common characteristics
Temperature drift @ 20°C
Pt100 0.003%/°C
Pt1000 0.005%/°C
unCerTaInTY anD resoluTIon of The InsTrumenT In measurInG WITh ThermoCouPles
Temperature measurement of the instrument
Measuring range Tc: K -200…+1370°C
Measuring range Tc: J -100…+750°C
Measuring range Tc: T -200…+400°C
Measuring range Tc: N -200…+1300°C
Measuring range Tc: R +200…+1480°C
Measuring range Tc: S +200…+1480°C
Measuring range Tc: B +200…+1800°C
Measuring range Tc: E -200…+750°C
resolution 0.05°C up to 199.95°C
0.1°C from 200.0°C to end scale
Instrument accuracy
Thermocouple K ±0.1°C up to 600°C
±0.2°C above 600°C
Thermocouple J ±0.05°C up to 400°C
±0.1°C above 400°C
Thermocouple T ±0.1°C
Thermocouple N ±0.1°C up to 600°C
±0.2°C above 600°C
Thermocouple R ±0.25°C
Thermocouple S ±0.3°C
Thermocouple B ±0.35°C
Thermocouple E ±0.1°C up to 300°C
±0.15°C above 300°C
accuracy is referred to the instrument only, error due to the thermocouple or to
the cold junction reference sensor is not included.
Temperature drift @20°C 0.02%/°C
Drift after 1 year 0.1°C/year
Type K Thermocouple probes
accuracy of the thermocouple probes
The tolerance of a type of thermocouple corresponds to the maximum acceptable depar-
ture from the e.m.f. of any thermocouple of that type, with reference junction at 0°C. The
tolerance is expressed in degrees Celsius, preceded by the sign. The percentage tolerance
is given by the ratio between the tolerance expressed in degrees Celsius and the meas-
urement junction temperature, multiplied by one hundred.
Tolerance classes for thermocouples (reference junction at 0°C)
Type of
Thermocouple
Tolerance
Class 1
Tolerance
Class 2
Tolerance
Class 3 (1)
T Type
Temperature interval Tolerance
Temperature interval Tolerance
from -40 to +125°C
± 0.5°C
from 125 to 350°C
± 0.004 · ltr
from -40 to +133°C
± 1°C
from 133 to 350°C
± 0.0075 · ltr
from -67 to +40°C
± 1°C
from -200 to -67°C
± 0.015 · ltr
e Type
Temperature interval Tolerance
Temperature interval Tolerance
from -40 to +375°C
± 1.5°C
from 375 to 800°C
± 0.004 · ltr
from -40 to +333°C
± 2.5°C
from 333 to 900°C
± 0.0075 · ltr
from -167 to +40°C
± 2.5°C
from -200 to -167°C
± 0.015 · ltr
J Type
Temperature interval Tolerance
Temperature interval Tolerance
from -40 to +375°C
± 1.5°C
from 375 to 750°C
± 0.004 · ltr
from -40 to +333°C
± 2.5°C
from 333 to 750°C
± 0.0075 · ltr
-
-
-
-
K Type, n Type
Temperature interval Tolerance
Temperature interval Tolerance
from -40 to +375°C
± 1.5°C
from 375 to 1000°C
± 0.004 · ltr
from 40 to +333°C
± 2.5°C
from 333 to 1200°C
± 0.0075 · ltr
from -167 to +40°C
± 2.5°C
from -200 to -167°C
± 0.015 · ltr
r Type, s Type
Temperature interval Tolerance
Temperature interval Tolerance
from 0 to +1100°C
± 1°C
from 1100 to 1600°C
± [ 1 + 0.003
(t-1 100)] °C
from 0 to +600°C
± 1.5°C
from 600 to 1600°C
± 0.0025 · ltr
-
-
-
-
B Type
Temperature interval Tolerance
Temperature interval Tolerance
-
-
-
-
-
-
from 600 to 1700 °C
± 0.0025 · ltr
from +600 to +800C
+ 4°C
from 800 to 1700°C
± 0.005 · ltr
(1) The materials used for thermocouples are generally supplied so to comply with the pro-
duction tolerances specified in the table for temperatures over -40°C. Nevertheless, these
materials may not comply with the production tolerances for low temperatures reported
under Class 3, for T, E, K and N thermocouples when the thermocouples have to comply at
the same time with the limits of Class 3 and those of Class 1 and/or Class 2.
Ø 3
300
150
Ø 4
230
Ø 5
230
Ø 3
150
Ø 4
230
Ø 5
230
Ø 4
500
Ø 6
1000
Ø 6
244 Multifunction
PT100 ProBes WITh sICram moDule for PorTaBle InsTrumenTs
CoDe °C max t s DIMENSIONS use
TP 472 I -196 +500 3s
TP 473 P -50 +400 5s
TP 474 C -50 +400 5s
TP 472 I.0 -50 +400 3s
TP 473 P.0 -50 +400 5s
TP 474 C.0 -50 +400 5s
TP 475 a.0 -50 +250 12s
TP 472 I.5 -50 +400 3s
TP 472 I.10 -50 +400 3s
150
Ø 2,7
Ø 4
150
150
Ø 2,7
70
Ø 3
230
Ø 3
21
40
Ø 8
Ø 21
1000
15
245
M
ul
tif
un
ct
io
n
Multifunction
PT100 ProBes WITh sICram moDule for PorTaBle InsTrumenTs
CoDe °C max t s DIMENSIONS use
TP 49 a -70 +400 3,5s
TP 49 aC -70 +400 5,5s
TP 49 aP -70 +400 4s
TP 87 -50 +200 3s
TP 878 +5 +80 60s Contact probe for solar panels. Cable L = 2m.
TP 878.1 +5 +80 60s Contact probe for solar panels. Cable L = 5m.
TP879 -20 +120 60s Penetration probe for compost. Cable L = 2m
TP 875 -30
+120
15s
Globe-thermometer probe for
measuring radiant heat ø150 mm.
(ISO7243, ISO7726). 4 wires Pt100
Sensor cable L=2m. equipped with
sICram module.
TP 876 -30
+120
15s
Globe-thermometer probe for
measuring radiant heat ø50 mm.
(ISO7243, ISO7726). 4 wires Pt100
Sensor cable L=2m. equipped with
sICram module.
sonDe sensore Pt100 / Pt1000 Con moDulo TP 47
CoDe °C max t s DIMENSIONS use
TP 47.100
(Pt100)
TP 47.1000
(Pt1000)
-50 +400 3s
TP 47
Only connector for connection
of probes without SICRAM
module: direct 3 and 4 wires
Pt100, 2 wires Pt1000.
180
Ø 1,5
90
Ø 1,5
230
Ø 1,5
180
Ø 2
90
Ø 2
230
Ø 2
180
Ø 3
180
Ø 4
246 Multifunction
ThermoCouPle ProBes for PorTaBle InsTrumenTs
ThermoCouPle K TYPe ProBes (Chromel - alumel)
CoDe °C max t s DIMENSIONS use
TP 741 800 2s
TP 741/1 400 2s
TP 741/2 800 2s
TP 742 800 2s
TP 742/1 400 2s
TP 742/2 800 2s
TP 743 800 3s
TP 744 400 4s
180
1
Ø 5
110
Ø 12Ø 3
Ø 3
500
300
Ø 3
25
Ø 2
200
Ø 15
Ø 15
200
35
Ø 27
300
Ø 27
300
50
247
M
ul
tif
un
ct
io
n
Multifunction
ThermoCouPle K TYPe ProBes (Chromel - alumel)
CoDe °C max t s DIMENSIONS use
TP 745 500 5s
TP 746 250 2s
TP 750 1000 3s
TP 750.0 800 3s
TP 751 200 2s
TP 754 500 2s
TP 754/9 500 2s
TP 755 800 2s
TP 755/9 800 2s
80
22
Ø 1,2
Ø 1,6
Ø 4
150
Ø 4
90
500mm
Ø 5
200
35
60
90
Ø 2
35
Ø 3
Ø 1
100
Ø 20
248 Multifunction
ThermoCouPle K TYPe ProBes (Chromel - alumel)
CoDe °C max t s DIMENSIONS use
TP 756 200 2s
TP 757 180 30s
MAGNETIC PROBE FOR CONTACT MEASURE ON MAGNETIC METALLIC SURFACES
TP 758 400 4s
TP 758.1 400 4s
TP 772 400 3s
TP 774 250 2s
TP 776 200 2s
TP 777 200 3s
1m / 2m / 3m / 5m
1200
Ø 6
700
Ø 6
Ø 6 ÷ 25
70
Ø 1
40
Ø 3,5
40
Ø 4
500
Ø 2
40
Ø 4
1000
Ø 2
Ø 5
500
Ø 1
30
249
M
ul
tif
un
ct
io
n
Multifunction
ThermoCouPle K TYPe ProBes (Chromel - alumel)
CoDe °C max t s DIMENSIONS use
TP 647
TP 647/2
TP 647/3
TP 647/5
300
300
300
300
2s
2s
2s
2s
SIT calibration up to 300°C.
TP 651 1200 6s
TP 652 1200 6s
TP 655 180 2s
TP 656 200 1s
TP 656/1 1000 1s
TP 656/2 1000 1s
TP 657/1 100 5s
TP 658 100 2s
150
Ø 3
150
Ø 4,5
85
40
L = 2m
Cs Cm
L = 2m
400
30
250 Multifunction
ThermoCouPle K TYPe ProBes (Chromel - alumel)
CoDe °C max t s DIMENSIONS use
TP 659 400 3s
TP 660 400 4s
TP 661 -60
+50
30s
TP 662 110 120s
PROBE WITH VELCRO TAPE FOR MEASURES ON PIPES MAX 110 DIAM.
Cm
Cs
“K”
“K”
PW “K”
response time for a 63% variation (t0.63)
The response time t s is the reaction time of the sensor to a temperature variation, with a signal variation when measuring that corresponds to a given percentage (63%)
of the variation.
Response time is referred:
For immersion probes in water at 100°C
For surface probes in contact with metals surface at 200°C
For air probe at an air temperature of 100°C
170
Ø 26
170
Ø 26
130 120
Ø 14
130 215
Ø 14
110 560
Ø 14
110 520
18x4
480
Ø 14
130
Ø 14
251
M
ul
tif
un
ct
io
n
Multifunction
Temperature and relative humidity probes with sICram module
model Temperaturesensor
Campo d’impiego accuracy
%rh Temperature %rh Temp
hP472aCr Pt100 0…100%RH -20°C…+80°C
±2%RH (5…90%RH)
±2,5%RH (remaining range)
±0.3°C
hP572aCr Thermocouple K 0…100%RH -20°C…+80°C ±0.5°C
hP473aCr Pt100 0…100%RH -20°C…+80°C ±0.3°C
hP474aCr Pt100 0…100%RH -40°C…+150°C
-40°C…150°C (180°C)
±(1,5+0,02 times the
displayed value)
±0.3°C
hP475aCr Pt100 0…100%RH -40°C…+150°C ±0.3°C
hP475aC1r Pt100 0…100%RH -40°C…+150°C ±0.3°C
hP477DCr Pt100 0…100%RH -40°C…+150°C ±0.3°C
hP478aCr Pt100 0…100%RH -40°C…+150°C ±0.3°C
Common characteristics
Relative Humidity
Sensor Capacitive
Typical capacity @30%RH 300pF
Probe temperature
working range -40°C…+150°C
Working range 0 … 100%RH
Accuracy ±1,5%RH (5…90%RH), ±2,5 remaining
range
Resolution 0.1%RH
Temperature drift @20°C 0.02%RH/°C
%RH response time at 10sec (10?80%RH; air speed=2m/s)
constant temperature
Temperature with Pt100 sensor
Resolution 0.1°C
Temperature drift @20°C 0.003%/°C
Temperature with thermocouple K-HP572AC
Resolution 0.1°C
Temperature drift @20°C 0.02%/°C
relaTIVe humIDITY anD TemPeraTure ProBes
Code sensors rangerh - Temp. DImensIons
hP472aCr RH
Pt100
5 ÷ 98% RH
-20°C…+80°ChP572aCr
RH
TC.K
hP473aCr
RH
Pt100
hP474aCr
5 ÷ 98% RH
-40°C…+150°C
hP475aCr
hP475aC1r
hP477DCr
hP478aCr
hP475aC
hP477DC
hP474aC
hP473aC
hP472aC
TP704…
TP705…
252 Multifunction
ProBes for Pressure measuremenT
Probes complete with sICram module
PP471: SICRAM module interface between instrument and pressure probes of the series
TP704 and TP705.
PP472: Barometric probe, measuring range 600…1100mbar. Resolution: 0.1mbar
Accuracy @ 20°C: ±0.3mbar. Temperature range: -10 … +60°C
PP473s1…s8: Differential pressure probes.
Working range s1=f.s.10mbar, s2=f.s.20mbar, s3=f.s.50mbar,
s4=f.s.100mbar, s5=f.s.200mbar, s6=f.s.500mbar,
s7=f.s.1bar, s8=f.s.2bar
Maximum overpressure s1,s2,s3=200mbar s4=300mbar s5,s6=1bar
s7=3bar s8=6bar
Accuracy @ 25°C ±0.5%f.s. (10, 20,
50mbar)
±0.25%f.s.
(100mbar)
±0.12% f.s.
(200, 500, 1000,
2000mbar)
Temperature range -10 … +60°C
Fluid in contact with
the membrane
non-corrosive dry gas or air
Connection tube Ø 5mm
Probes to couple to the module to measure the absolute, relative or differential pressure.
TP704…/TP705…: Probes to connect to SICRAM module PP471 for measuring relative,
absolute or differential pressure.
Pressure ProBe TaBle
Bottom scale
pressure
maximum
overpressure resolution
orDer CoDes accuracy
from 20 to 25°C
Working
temperature ConnectionDifferential pressure relative pressure(compared to atmosphere) absolute pressure
NON insulated membrane Insulated membrane Insulated membrane
10.0 mbar 20.0 mbar 0.01 mbar • TP705-10MBD 0.5 % FSO 0..60 °C Tube Ø 5 mm
20.0 mbar 40.0 mbar 0.01 mbar • TP705-20MBD 0.5 % FSO 0..60 °C Tube Ø 5 mm
50.0 mbar 100 mbar 0.01 mbar TP705-50mBD 0.5 % FSO 0..60 °C Tube Ø 5 mm
100 mbar 200 mbar 0.1 mbar
TP705-100mBD 0.25 % FSO 0..60 °C Tube Ø 5 mm
TP704-100mBGI 0.25 % FSO -10..+80 °C ¼ BSP
200 mbar 400 mbar 0.1 mbar
TP705-200mBD 0.25 % FSO 0..60 °C Tube Ø 5 mm
TP704-200mBGI 0.25 % FSO -10..+80 °C ¼ BSP
400 mbar 1000 mbar 0.1 mbar TP704-400mBGI 0.25 % FSO -10..+80 °C ¼ BSP
500 mbar 1000 mbar 0.1 mbar TP705-500mBD 0.25 % FSO 0..60 °C Tube Ø 5 mm
600 mbar 1000 mbar 0.1 mbar TP704-600mBGI 0.25 % FSO -40..125 °C ¼ BSP
1.00 bar 2.00 bar 1 mbar
TP705-1BD 0.25 % FSO 0..60 °C Tube Ø 5 mm
TP705Baro 0.25 % FSO 0..60 °C Tube Ø 5 mm
0.25 % FSO -40..125 °C ¼ BSP
TP704-1Ba 0.25 % FSO -40..120 °C ¼ BSP
2.00 bar 4.00 bar 1 mbar
TP705-2BD 0.25 % FSO 0..60 °C Tube Ø 5 mm
TP704-2BGI 0.25 % FSO -40..+125 °C ¼ BSP
TP704-2BaI * 0.25 % FSO -25..+85 °C ¼ BSP
5.00 bar 10.00 bar 1 mbar
TP704-5BGI 0.25 % FSO -40..+125 °C ¼ BSP
TP704-5BaI * 0.25 % FSO -25..+85 °C ¼ BSP
10.00 bar 20.0 bar 0.01 bar
TP704-10BGI 0.25 % FSO -40..+125 °C ¼ BSP
TP704-10BaI * 0.25 % FSO -25..+85 °C ¼ BSP
20.0 bar 40.0 bar 0.01 bar
TP704-20BGI 0.25 % FSO -40..+125 °C ¼ BSP
TP704-20BaI * 0.25 % FSO -25..+85 °C ¼ BSP
50.0 bar 100.0 bar 0.01 bar
TP704-50BGI 0.25 % FSO -40..+125 °C ¼ BSP
TP704-50BaI * 0.25 % FSO -25..+85 °C ¼ BSP
100 bar 200 bar 0.1 mbar
TP704-100BGI 0.25 % FSO -40..+125 °C ¼ BSP
TP704-100BaI * 0.25 % FSO -25..+85 °C ¼ BSP
200 bar 400 bar 0.1 mbar
TP704-200BGI 0.25 % FSO -40..+125 °C ¼ BSP
TP704-200BaI * 0.25 % FSO -25..+85 °C ¼ BSP
500 bar
1000 bar 0.1 mbar TP704-500BGI 0.25 % FSO -40..+125 °C ¼ BSP
700 bar 0.1 mbar TP704-500BaI * 0.25 % FSO -25..+85 °C ¼ BSP
* Ceramic diaphragm
• Only report of calibration, no SIT certificate
T4...
T3...
T3...
T2...
T2...
T1...
aP472s1…
aP472s2…
aP472s4…
aP471s3
aP471s2
aP471s1
253
M
ul
tif
un
ct
io
n
Multifunction
ProBes anD moDules TeChnICal DaTa eQuIPPeD WITh InsTrumenT
Wind speed measurement probes
hot-wire probes: aP471 s1 - aP471 s2 - aP471 s3 - aP471 s4
aP471 s1 - aP471 s3 aP471 s2 aP471 s4
Type of measure Air speed, calculated flow rate, air temperature
Type of sensor
Speed NTC thermistor Omnidirectional NTC thermistor
Temperature NTC thermistor NTC thermistor
Measurement range
Speed 0,1…40m/s 0,1…5m/s
Temperature -25…+80°C -25…+80°C 0…80°C
Measurement resolution:
Speed
0.01 m/s
0.1 km/h
1 ft/min
0.1 mph
0.1 knot
Temperature 0.1°C
Measurement accuracy:
Speed ±0.1 m/s (0…0.99 m/s) ±0.05m/s (0…0.99 m/s)
±0.3 m/s (1.00…9.99 m/s) ±0.15m/s (1.00…5.00 m/s)
±0.8 m/s (10.00…40.0 m/s)
Temperature ±0.8°C (-10…+80°C) ±0.8°C (-10…+80°C)
Minimum speed 0.1 m/s
Air temperature
compensation 0…80°C
Sensor working conditions Clean air, RH<80%
Battery life Approx. 20 hours @ 20 m/s with alkaline batteries
Approx. 30 hours @ 5 m/s with alka-
line batteries
Unit of Measurement
Speed m/s – km/h – ft/min – mph – knot
Flow rate l/s - m3/s - m3/min - m3/h - ft3/s - ft3/min
Pipeline section for flow
rate calculation 0.0001…1.9999 m
2
Cable length ~2m
Vane probes: aP472 s1… - aP472 s2 - aP472 s4…
aP472 s1… aP472 s2
aP472 s4…
l lT h hT
Type of measure
Air speed,
calculated flow
rate,
air temperature
Air speed,
calculated
flow rate
Air speed,
calculated
flow rate.
Air speed,
calculated
flow rate,
air tempera-
ture.
Air speed,
calculated
flow rate.
Air speed,
calculated
flow rate,
air tempera-
ture.
Diameter 100mm 60mm 16mm
Type of measurement
Speed Vane Vane Vane
Temperature K thermocouple ---- ---- K thermocouple ----
K thermo
couple
Measurement range
Speed (m/s) 0.6…25 0.5…20 0.8…20 10…40
Temperature (°C) -25…+80 (*) -25...+80 (*)
Resolution
Speed
0.01 m/s
0.1 km/h
1 ft/min
0.1 mph
0.1 knot
Temperature 0.1°C ---- ---- 0.1°C ---- 0.1°C
Accuracy
Speed ±(0.3 m/s +1.5%f.s.)
±(0.3m/s
+1.5%f.s.) ±(0.4 m/s +1.5%f.s.)
Temperature ±0.8°C ---- ---- ±0.8°C ---- ±0.8°C
Minimum speed 0.6m/s 0.5m/s 0.8m/s 10m/s
Unit of Measurement
Speed m/s – km/h – ft/min – mph – knot
Flow rate l/s - m3/s - m3/min - m3/h - ft3/s - ft3/min
Pipeline section for
flow rate calculation 0.0001…1.9999 m
2
Cable length ~2m
(*) The indicated value refers to the vane’s working range.
lP471lum2
lP471PhoT
lP471raD
lP471Par
lP471uVa
lP471uVB
lP471uVC
aP471s4
254 Multifunction
Pitot tube probes: aP473 s1 - aP473 s2 - aP473 s3 - aP473 s4
aP473 s1 aP473 s2 aP473 s3 aP473 s4
Kind of
measurement
Air speed, calculated flow,
differential pressure, Air temperature
Working range
Diff. pressure 10 mbar f.s. 20mbar f.s. 50mbar f.s. 100mbar f.s.
Speed (*) 2 … 40m/s 2 … 55m/s 2 … 90m/s 2 … 130m/s
Temperature -200…+600°C -200…+600°C -200…+600°C -200…+600°C
Resolution
Speed m/s 0.1
km/h 1
ft/min 1.103
mph 1
Knots 1
Temperature 0.1°C
Accuracy
Speed ±0.4%f.s. of pressure ±0.3%f.s. of pressure
Temperature ±0.8°C ±0.8°C
Minimum speed 2 m/s
Air temperature
compensation -200…+600°C (if K thermocouple is connected to the module)
Unit of measurement
Speed m/s - km/h - ft/min - mph - Knots
Flow rate l/s - m3/h - m3/min - ft3/s - ft3/min
Duct section for
flow calculation .001…1.999 m
2
(*) A 20°C, 1013mbar and Ps negligible.
PhoTomeTrIC anD raDIomeTrIC ProBes
Technical characteristics of photometric and radiometric probes complete with
sICram module equipped with the instruments
IllumInanCe measurement probe lP 471 PhoT
Measurement range (lux): 0.01…199.99 …1999.9 …19999 …199.99·103
Resolution (lux): 0.01 0.1 1 0.01·103
Spectral range: in agreement with standard photopic curve V(?)
Class C (B on request)
Calibration uncertainty: <4%
f’1 (in agreement with photopic
response V(?)): <8%
f2 (response according to the cosine law): <3%
f3 (linearity): <1%
f4 (instrument reading error): <0.5%
f5 (fatigue): <0.5%
a (temp. coefficient) f6 (T) <0.05%K
Drift after 1 year: <1%
Functioning temperature: 0…50°C
Reference Standards CIE n.69 - UNI 11142
Photometric probe for IllumInanCe measurement,
spectral response in agreement with standard
photopic vision, diffuser for cosine correction.
Measurement range: 0.01 lux…200·103 lux.
0
0,1
0,2
0,3
0,4
0,5
0,6
0,7
0,8
0,9
1
380 430 480 530 580 630 680 730 780 830
? (nm)
0
0,1
0,2
0,3
0,4
0,5
0,6
0,7
0,8
0,9
1
350 450 550 650 750 850 950 1050
? (nm)
0
0,1
0,2
0,3
0,4
0,5
0,6
0,7
350 400 450 500 550 600 650 700 750 800 850
Re
la
tiv
e
sp
ec
tra
l r
es
po
ns
e
PAR
? (nm)
0
0,1
0,2
0,3
0,4
0,5
0,6
0,7
0,8
0,9
1
280 300 320 340 360 380 400 420
? (nm)
255
M
ul
tif
un
ct
io
n
Multifunction
lumInanCe measurement probe lP 471 lum 2
Measurement range (cd/m2): 0.1…1999.9 …19999 …199.99·103 …1999.9·103
Resolution (cd/m2): 0.1 1 0.01·103 0.1·103
Optical angle: 2°
Spectral range: in agreement with standard photopic curve V(?)
Class C
Calibration uncertainty: <5%
f’1 (in agreement with photopic
response V(?)): <8%
f3 (linearity): <1%
f4 (instrument reading error): <0.5%
f5 (fatigue): <0.5%
a (temp. coefficient) f6 (T) <0.05%K
Drift after 1 year: <1%
Functioning temperature: 0…50°C
Reference Standards CIE n.69 - UNI 11142
Photometric probe for lumInanCe measurement, spectral response
in agreement with standard photopic vision, vision angle 2°.
Measurement range: 0.1 cd/m2…2000·103 cd/m2.
Typical response curve: LP 471 PHOT and LP471 LUM 2
Quantum radiometric probe for the measurement of the photon flow across the chlorophyll
range Par lP 471 Par
Measurement range (µmolm-2s-1): 0.01… 199.99 200.0…1999.9 2000…10000
Resolution (µmolm-2s-1): 0.01 0.1 1
Spectral range: 400nm…700nm
Calibration uncertainty: <5%
f’
1 (response according to the cosine law): <6%
f
3 (linearity): <1%
f
4 (instrument reading error): ±1digit
f5 (fatigue): <0.5%
Drift after 1 year: <1%
Working temperature: 0…50°C
Quantum radiometric probe for the measurement of the
photon flow across the chlorophyll range Par
(Photosynthetically Active Radiation 400nm…700nm),
measurement in µmol/m2s. Measurement range:
0.01µmol/m-2s-1…10·103µmol/m-2s-1.
Typical response curve: LP 471 PAR
IrraDIanCe measurement probe lP 471 raD
Measurement range (W/m2): 0.1·10
-3
… 999.9·10-3
1.000
…19.999
20.00
…199.99
200.0
…1999.9
Resolution (W/m2): 0.1·10-3 0.001 0.01 0.1
Spectral range: 400nm…1050nm
Calibration uncertainty: <5%
f’
1 (response according to
the cosine law): <6%
f3 (linearity): <1%
f
4 (instrument reading error): ±1digit
f
5 (fatigue): <0.5%
Drift after 1 year: <1%
Working temperature: 0…50°C
Radiometric probe for IrraDIanCe measurement in the
spectral range 400nm…1050nm, diffuser for cosine
correction. Measurement range:
0.1·10-3W/m2 …2000 W/m2.
Typical response curve: LP 471 RAD
IrraDIanCe measurement probe lP 471 uVa
Measurement range (W/m2): 0.1·10
-3
… 999.9·10-3
1.000
…19.999
20.00
…199.99
200.0
…1999.9
Resolution (W/m2): 0.1·10-3 0.001 0.01 0.1
Spectral range: 315nm…400nm (Peak 360nm)
Calibration uncertainty: <5%
f’
1 (response according to the
cosine law): <6%
f3 (linearity): <1%
f
4 (instrument reading error): ±1digit
f
5 (fatigue): <0.5%
Drift after 1 year: <2%
Working temperature: 0…50°C
Radiometric probe for IrraDIanCe measurement, in the
315nm…400nm, peak 360nm, uVa spectral range.
Measurement range: 0.1·10-3W/m2…2000 W/m2.
Typical response curve: LP 471 UVA
Ri
sp
os
ta
s
pe
ttr
al
e
re
la
tiv
a
Ri
sp
os
ta
s
pe
ttr
al
e
re
la
tiv
a
Ri
sp
os
ta
s
pe
ttr
al
e
re
la
tiv
a
Ri
sp
os
ta
s
pe
ttr
al
e
re
la
tiv
a
0
0,1
0,2
0,3
0,4
0,5
0,6
0,7
0,8
0,9
1
250 260 270 280 290 300 310 320 330 340 350
? (nm)
0,00001
0,0001
0,001
0,01
0,1
1
10
250 270 290 310 330 350 370 390
? (nm)
0
0,1
0,2
0,3
0,4
0,5
0,6
0,7
0,8
0,9
1
200 210 220 230 240 250 260 270 280 290 300
? (nm)
256 Multifunction
IrraDIanCe measurement probe lP 471 uVB
Measurement range (W/m2): 0.1·10
-3
… 999.9·10-3
1.000
…19.999
20.00
…199.99
200.0
…1999.9
Resolution (W/m2): 0.1·10-3 0.001 0.01 0.1
Spectral range: 280nm…315nm (Peak 305nm)
Calibration uncertainty: <5%
f’
1 (response according to the
cosine law): <6%
f3 (linearity): <2%
f4 (instrument reading error): ±1digit
f
5 (fatigue): <0.5%
Drift after 1 year: <2%
Working temperature: 0…50°C
Radiometric probe for IrraDIanCe measurement,
in the spectral range 280nm…315nm, peak 305nm,
uVB. Measurement range: 0.1·10-3W/m2…2000 W/m2.
Typical response curve: LP 471 UVB
IrraDIanCe measurement probe lP 471 uVC
Measurement range (W/m2): 0.1·10
-3
… 999.9·10-3
1.000
…19.999
20.00
…199.99
200.0
…1999.9
Resolution (W/m2): 0.1·10-3 0.001 0.01 0.1
Spectral range: 220nm…280nm (Peak 260nm)
Calibration uncertainty: <5%
f’1 (response according to the
cosine law): <6%
f3 (linearity): <1%
f4 (instrument reading error): ±1digit
f5 (fatigue): <0.5%
Drift after 1 year: <2%
Working temperature: 0…50°C
Radiometric probe for IrraDIanCe measurement,
in the spectral range 220nm…280nm, peak 260nm,
uVC. Measurement range: 0.1·10-3W/m2…2000 W/m2.
Typical response curve: LP 471 UVC
measurement probe lP 471erY of ToTal effeCTIVe IrraDIanCe (W/m2) according to the
uV action curve uV (CeI en 60335-2-27)
Measurement range (Weff /m
2): 0.1·10
-3
… 999.9·10-3
1.000
…19.999
20.00
…199.99
200.0
…1999.9
Resolution (Weff /m
2): 0.1·10-3 0.001 0.01 0.1
Spectral range: UV action curve for erythema measurement (250nm…400nm)
Calibration uncertainty: <15%
f
3 (linearity): <3%
f
4 (instrument reading error ±1digit
f5 (fatigue): <0.5%
Drift after 1 year <2%
Working temperature: 0…50°C
Reference standard CEI EN 60335-2-27
Radiometric probe for effeCTIVe ToTal IrraDIanCe
(W
eff /m
2) according to the UV action curve
(CIE EN 60335-2-27). Spectral range: 250 nm…400 nm,
Measurement range: 0.1·10-3Weff /m
2 … 2000 Weff /m
2
Typical response curve. TOTAL EFFECTIVE IRRADIANCE
LP 471 ERY
Ri
sp
os
ta
s
pe
ttr
al
e
re
la
tiv
a
Ri
sp
os
ta
s
pe
ttr
al
e
re
la
tiv
a
Ri
sp
os
ta
s
pe
ttr
al
e
re
la
tiv
a
Solid line = Action curve
Dashed line = Spectral sensitivity LP471ERY probe
The probe LP 471 ERY measures the total effective irradiance (Weff/m
2) according to the
UV action curve (CEI EN 60335-2-27). A particular type of photodiode and a combination
of special filters bring the spectral response closer to the UV action curve.
CEI EN 60335-2-27 standards estabilish a maximum allowable dose of 100J/m2 for first-
time exposure and an annual dose of 15000J/m2.
The typical spectral response curve of LP 471 ERY is shown in the Figure together with
the UV action curve.
The good accordance between the two curves enables the instrument to take reliable
measurements of different types of lamps (and filters) used at present for tanning
machines.
Each probe is individually calibrated at DeltaOhm photo-radiometry laboratory by means
of a double monochrome. Calibration is performed at 290 nm through a sIT calibra-
ted reference photodiode.
PP473-s... aP473-s3
PP472
257
M
ul
tif
un
ct
io
n
Multifunction
orDerInG CoDes
Do 9847K: The kit is provided with multifunctional instrument, 9CPRS232 serial output
cable, 4 1.5V alkaline batteries, instruction manual and carrying case. modules
and probes have to be ordered separately .
9CPrs232: Female/female sub D 9 pole extension cable for RS232C (null modem).
Deltalog3: Software for downloading and PC data management.
TP471: Measures the temperature with PRT Platinum sensors
Resistance values of the PRT @ 0°C 25O, 100O, 500O
Measuring range Pt25, Pt100 -200°C…+850°C
Measuring range Pt500 -200°C…+500°C
Accuracy
with Pt25, Pt100 sensor ±0.03°C till 350°C
±0.3°C till 500°C
Accuracy with Pt500 sensor ±0.5°C till 500°C
Resolution 0.01°C from -200°C till 350°C
0.1°C from 350°C till 850°C
Temperature drift @20°C 0.02%/°C
Excitation current 400µA impulse, length=100ms, time=1s
TP471D0: Measures the temperature with thermocouple, cold junction at 0°C inside ice.
TP471D: Measures the temperature with thermocouple, 1 input
TP741D1: Measures the temperature with thermocouple, 2 inputs
VP472: Module for connecting pyranometers or albedometers. For acquisition, verifica-
tion, and storage of the values generated by a pyranometer or albedometer. The
generated value can be read in mV or in W/m², the net radioation of the albedometer
is read in W/m². The sensitivity can be set between 5000 and 30000nV/(W/m²), or
rather between 5 and 30µV/(W/m²).
VP473: Module for reading continuous voltage. Reads and acquires values when con-
nected to a transmitter with voltage signal. Measuring range ±20Vdc. Input imped-
ance: 1MO.
IP472: Module for reading continuous current. Reads and acquires current values when
connected to a transmitter with current output. Measuring range 0…24mA Input
impedance: 25O.
PP471: Module for the measurement of absolute, relative, and differential pressure.
Works with pressure probes of the series TP704 and TP705. Provides instanta-
neous value and pressure peak value. Includes cable L=2 and 8-pole DIN 45326
female connector.
Accuracy: ±0.05% of f.s. Peak time: = 5ms
Accuracy of the peak: ±0.5% f.s Peak dead band: = 2% f.s.
Probes complete with sICram module
TemPeraTure measuremenT ProBes
TP472I: Immersion probe, sensor Pt100. Stem Ø 3 mm, length 300 mm. Cable length
2 metres.
TP472I.0: Immersion probe, sensor Pt100. Stem Ø 3 mm, length 230 mm. Cable length
2 metres.
TP473P: Penetration probe, sensor Pt100. Stem Ø 4mm, length 150 mm. Cable length
2 metres.
TP473P.0: Penetration probe, sensor Pt100. Stem Ø 4mm, length 150 mm. Cable length
2 metres.
TP474C: Contact probe, sensor Pt100. Stem Ø 4mm, length 230mm, contact surface Ø
5mm. Cable length 2 metres.
TP474C.0: Contact probe, sensor Pt100. Stem Ø 4mm, length 230mm, contact surface Ø
5mm. Cable length 2 metres.
TP475a.0: Air probe, sensor Pt100. Stem Ø 4mm, length 230mm. Cable length 2
metres.
TP472I.5: Immersion probe, sensor Pt100. Stem Ø 6mm, length 500 mm. Cable length
2 metres.
TP472I.10: Immersion probe, sensor Pt100. Stem Ø 6mm, length 1,000mm. Cable length
2 metres.
TP49a: Immersion probe, Pt100 sensor. Stem Ø 2.7 mm, Length 150 mm. Cable 2 meters
long. Aluminium handle.
TP49aC: Contact probe, Pt100 sensor. Stem Ø 4 mm, Length 150 mm. Cable 2 meters
long. Aluminium handle.
TP49aP: Penetration probe, Pt100 sensor. Stem Ø 2.7 mm, Length 150 mm. Cable 2
meters long. Aluminium handle.
TP875: Globe thermometer Ø 150 mm with handle. Cable 2 metres
TP876: Globe thermometer Ø 50 mm with handle. Cable 2 metres.
TP87: Immersion probe, Pt100 sensor. Stem Ø 3 mm, lenght 70 mm. Cable 2 metres.
TP878: Contact probe for solar panels. Cable 2 metres.
TP878.1: Contact probe for solar panels. Cable 5 metres.
TP879: Penetration probe for compost. Stem Ø 8 mm, Length 1 m. Cable 2 meters.
Temperature probes without sICram module
TP47.100: Immersion probe, 4 wire direct Pt100 sensor. Stem Ø 3mm, length 230mm. 4
wire connecting cable with connector, length 2 metres.
TP47.1000: Immersion probe, 4 wire direct Pt1000 sensor. Stem Ø 3mm, length 230mm.
4 wire connecting cable with connector, length 2 metres.
TP47: Connector for probes connection: 4 wire direct Pt100.
T3-800TC
PW
aP471s2
aP471s1
258 Multifunction
relative humidity and temperature probes complete with sICram module
hP472aCr: %RH and temperature combined probe, dimensions Ø 26x170 mm. 2 m
connecting cable.
hP572aCr: %RH and temperature combined probe, K thermocouple sensor. Dimen-
sions Ø 26x170 mm. 2 m connecting cable.
hP473aCr: %RH and temperature combined probe. Dimensions: handle Ø 26x130 mm,
probe Ø 14x110 mm. 2m connecting cable.
hP474aCr: %RH and temperature combined probe. Dimensions: handle Ø 26x130 mm,
probe Ø 14x210 mm. 2m connecting cable.
hP475aCr: %RH and temperature combined probe. 2 m connecting cable. Handle Ø
26x110 mm. Stainless-steel tube Ø 12x560 mm. Terminal tip Ø 13.5x75 mm.
hP475aC1r: %RH and temperature combined probe. 2 m connection cable. Handle Ø
26x110 mm. Stainless steel stern Ø 14x480 mm.
hP477DCr: %RH and temperature combined sword probe. 2 m connecting cable. Handle
Ø 26x110 mm. Probe tube 18x4 mm, length 520 mm.
hP478aCr: %RH and temperature combined probe. Dimensions Ø 14x130 mm. 5m con-
nection cable.
ProBes for Pressure measuremenT
Probes complete with sICram module
PP471: SICRAM module interface between instrument and pressure probes of the series
TP704 and TP705.
PP472: Barometric probe, measuring range 600…1100mbar. Resolution: 0.1mbar
Accuracy @ 20°C: ±0.3mbar. Temperature range: -10 … +60°C
PP473s1…s8: Differential pressure probes.
Working range s1=f.s.10mbar, s2=f.s.20mbar, s3=f.s.50mbar,
s4=f.s.100mbar, s5=f.s.200mbar, s6=f.s.500mbar,
s7=f.s.1bar, s8=f.s.2bar
Maximum overpressure s1,s2,s3=200mbar s4=300mbar s5,s6=1bar
s7=3bar s8=6bar
Accuracy @ 25°C ±0.5%f.s. (10, 20,
50mbar)
±0.25%f.s.
(100mbar)
±0.12% f.s.
(200, 500, 1000,
2000mbar)
Temperature range -10 … +60°C
Fluid in contact with
the membrane
non-corrosive dry gas or air
Connection tube Ø 5mm
Probes to couple to the module to measure the absolute, relative or differential pressure.
TP704…/TP705…: Probes to connect to SICRAM module PP471 for measuring relative,
absolute or differential pressure.
ProBes for aIr sPeeD measuremenTs
Probes equipped with sICram modules
hoT-WIre ProBes
aP471 s1: Hot-wire telescopic probe, measuring range: 0.1…40m/s.
aP471 s2: Omni-directional hot-wire probe, measuring range: 0.1…5m/s.
aP471 s3: Hot-wire telescopic probe with terminal tip for easy position, measuring
range: 0.1…40m/s.
aP471 s4: Omnidirectional hot-wire telescopic probe with base, measuring range:
0.1…5m/s. Cable length 2 metres.
Vane probes:
aP472 s1: Vane probe with thermocouple, Ø 100mm. Speed from 0.6 to 25m/s; tem-
perature from -25 to 80°C. Cable length 2 metres.
aP472 s2: Vane probe, Ø 60mm. Measurement range: 0.5…20m/s. Cable length 2
metres.
aP472 s4l: Vane probe, Ø 16mm. speed from 0.8 to 20m/s. Cable length 2 metres.
aP472 s4lT: Vane probe with thermocouple, Ø 16mm, speed from 0.8 to 20m/s. Tem-
perature from -25 to 80°C with thermocouple K sensor(*). Cable length 2 metres.
aP472 s4h: Vane probe, Ø 16mm speed from 10 to 40m/s. Cable length 2
metres.
aP472 s4hT: Vane probe with thermocouple, Ø 16mm speed from 10 to 40m/s. Tem-
perature from -25 to 80°C with thermocouple K sensor(*). Cable length 2 metres.
moDules for PIToT TuBes
aP473 s1: Pitot tube probe, differential pressure 10mbar f.s. Air speed from 2 to 40m/s.
The Pitot tube has to be ordered separately.
aP473 s2: Pitot tube probe, differential pressure 20mbar f.s. Air speed from 2 to 55m/s.
The Pitot tube has to be ordered separately.
aP473 s3: Pitot tube probe, differential pressure 50mbar f.s. Air speed from 2 to 90m/s.
The Pitot tube has to be ordered separately.
aP473 s4: Pitot tube probe, differential pressure 100mbar f.s. Air speed from 2 to
130m/s. The Pitot tube has to be ordered separately.
PW: Connection cable between AP473S… module and Pitot tube.
lP Bl
aP472s1
aP471s1
259
M
ul
tif
un
ct
io
n
Multifunction
PIToT TuBes
Stainless steel Pitot tubes to measure air speed and temperature for models provided
with ‘K’ thermocouple. They can be connected to the SICRAM modules AP473S1,
AP473S2, AP473S3 and AP473S4
d1
d
L
L1
L 2
D
d
mm
d1
mm
D
mm
l
mm
l1
mm
l2
mm Temp.°C
Thermo-
couple K material
T1-300 3 1 6 300 30 72
0…600°C
---
AISI 316
T2-400 5 2 8 400 45 120 ---
T2-600 5 2 8 600 45 120 ---
T3-500 8 3.2 8 500 --- 192 ---
T3-800 8 3.2 8 800 --- 192 ---
T3-800TC 8 3.2 8 800 --- 192 TC
T4-500 10 4.0 10 500 --- 240 ---
T4-800 10 4.0 10 800 --- 240 ---
T4-800TC 10 4.0 10 800 --- 240 TC
T4-1000 10 4.0 10 1000 --- 240 ---
T4-1000TC 10 4.0 10 1000 --- 240 TC
ProBes for lIGhT measuremenT
Probes complete with sICram module
lP 471 PhoT: Photometric probe for IllumInanCe measurement complete with SICRAM
module, spectral response in agreement with standard photopic vision, diffuser for
cosine correction. Measurement range:
0.01 lux…200·103 lux.
lP 471 lum 2: Photometric probe for lumInanCe measurement complete with SICRAM
module, spectral response in agreement with standard photopic vision, vision angle
2°. Measurement range: 0.1 cd/m2…2000·103 cd/m2.
lP 471 Par: Quantum radiometric probe for the measurement of the photon flow across
the chlorophyll range Par (Photosynthetically Active Radiation 400nm…700nm)
complete with SICRAM, measurement in µmol/m2s, diffuser for cosine correction.
Measurement range: 0.01µmol/m2s…10·103µmol/m2s.
lP 471 raD: Radiometric probe for IrraDIanCe measurement complete with SICRAM
module; in the 400nm…1050nm spectral range, diffuser for cosine correction.
Measurement range: 0.1·10-3W/m2 …2000 W/m2.
lP 471 uVa: Radiometric probe for IrraDIanCe measurement complete with SICRAM
module; in the 315nm…400nm, peak 360nm, uVa spectral range, quartz diffuser
for cosine correction. Measurement range:
0.1·10-3W/m2…2000 W/m2.
lP 471 uVB: Radiometric probe for IrraDIanCe measurement complete with SICRAM
module, in the 280nm…315nm, peak 305nm, uVB spectral range, quartz diffuser
for cosine correction. Measurement range:
0.1·10-3W/m2…2000 W/m2.
lP 471 uVC: Radiometric probe for IrraDIanCe measurement complete with SICRAM
module, in the 220nm…280nm, peak 260nm, uVC spectral range, quartz diffuser
for cosine correction. Measurement range:
0.1·10-3W/m2…2000 W/m2.
lP 471 erY: Radiometric probe for ToTal effeCTIVe IrraDIanCe (Weff/m
2) according
to the UV action curve (CEI EN 60335-2-27) complete with SICRAM module. Spec-
tral range: 250 nm…400 nm, quartz diffuser for cosine correction. Measurement
range: 0.1·10-3Weff /m
2 … 2000 Weff /m
2.
lP Bl: Base with levelling device for the probes (except LP 471 LUM2).
lP 471 lum 2