Parca EL 36 - Electric Brochure (PDF 728 KB)
For professional usersTelephone: +46 479 177 00 • info@osbyparca.se • www.osbyparca.se• After a power cut of more than 3 min, boiler power reactivation is delayed for 1 hour.• Boiler power reactivation is controlled in 7 steps of 5.2 kW. The number of steps can be limited for lower boiler powers.• The system main fuse can be protected by installing current transformers and current sensors.• Boiler water temperature is controlled in accordance with the expected values set. The electric boiler is equipped with adjustable overheating protection, which provides the opportunity for simple testing. The overheating protection remains in the circuit broken mode after overheating.Parca EL 3636 kWSmall electric boiler with microprocessor controlled regulation equipmentPart no. TypePower kWPower stepkW numberVoltageVCurrentARec fuseAConn. cablearea mm2Weightkg76 00 064-03 EL 36 36 5,2 73x400 PE+N 53 63 25 40Technical dataOsbyParca • Parca EL 36 1. Supply line con. 32 (ext. threaded)2. Return line con. 32 (ext. threaded)3. Drain line R1” ext4. Connection aperture El 1 x 48 3 x 22.5Note that the boiler is supplied without a switch. The boiler should be positioned minimum 500 mm above the floor.AccessoriesPart no. 3317-0202 Outdoor temperature compensator for OX 2001 incl. outdoor sensor.Part no. 11 18 404-01 3 x current sensors for secondary measurements max 5A. NB Excl system adapted current transformer.Part no. 76 41 437-01 Frame H = 500 mmDimensions and connectionsParc OX 2001 – an electronic control systemPart.no. 4992-0401 Edition A Production: Joma GP 2009-06 Tecnical data may be subject to change without previous notice.OX 2001 is an electronic control system for EL 36, EL 50, EL 150, EL 350 and EL 500 series boilers. The unit consists of two printed circuit cards fitted one above the other. All 230V connections are to the lower printed circuit card. The upper card contains electronics for the control and regulation functions and a dis-play with 8 light diodes to indicate status. OX 2001 has the following options/functions:• External limitation which shows whether the external analogue input limits or blocks power.• One hour delay after power failure.• Current limitation.• Supply line temperature in balance with set expected value.• Power regulation.• Step regulation.• 6 x light diodes which show which power steps are activated.• 7 x potentiometers for setting: – step time. – current limit. – current margin. – min. limit. – max. limit. – expected boiler temperature.• 4 x buttons for reading and setting parameters.• 8 x electronic DIL switches for programming the boiler: – supply line sensor. – overtemperature setting, relative or constant. – internal or external expected values. – external expected signal value 0–10 V or 4–20 mA. – input – external signal for power control 0–10 V or 4–20 mA. – relay function, alarm or operation indication.• Options: – outdoor compensator. – current sensor for current limitation.Osby Parca Division • Box 93 • SE-283 22 Osby, SwedenTelephone: +46 479 177 00 • Fax: + 46 479 177 25info@osbyparca.se • www.osbyparca.se Flow l/sMax Flow 1.8 l/sec. (? = 5°C)Water resistanceDesign dataDesign pressure 4.0 barsOperating temperature max 100°CBoiler volume 24 litresProtection IP21The boiler is produced according to current standards and direc-tives in Europe or US.Design Codes97/23/EC art. 3.3 Pressure equipment directive73/23/EEG Low voltage directive89/336/EEG EMC directive
Most popular related searches