Power Partners, Inc.

Power Partners - Single-Phase Specifications Sheet

Power Partners Inc.Athens, GAISO 9001 CertifiedPDL 46-200Page 1Single PhaseOverheadDistributionTransformersPower Partners, Inc. single phase, oil-filled, pole-mounted distribution transformers are specifically designed for servicing residential overhead distribution loads. They are also suitable for light commercial loads, industrial lighting and diversified power applications. These transformers are designed for the application conditions normally encoun-tered on electric utility power distribution systems.Ratings• 5-1000 kVA• 65° C temperature rise• 60 hertz standard, 50 hertz optional• Low voltages: 120/240, 240/480 and 277• High voltages: 2400 through 34,400 Volts• Insulation levels:Standard Features: 1. Lifting lugs. 2. Arrester mounting pads. 3. Cover-mounted high voltage porcelain bushing(s) with eyebolt terminal (10-100 kVA) or spade terminal. 4. Low voltage insulators are available in fiberglass reinforced polyester material or porcelain (both eyebolt and spade terminals). 5. Low voltage neutral grounding strap (furnished on 10-50 kVA single HV bushing units). 6. ANSI support lugs (hanger brackets). 7. Cover has 13 mils minimum of polyester coating providing 15 kV dielectric insulation of tank ground parts from live parts and increased resistance to corrosion. 8. Self-venting and resealing cover assembly. 9. The core/coil bolt-in pads are 180° apart. 10. Embossed low voltage leads.11. Oil filled plug with cover ground strap.12. Tank ground pad.13. Laser etched anodized aluminum nameplate with bar coded serial number.14. The paint finish process applies a durable, corrosion resistant finish to the product. The finish meets or exceeds all the performance require-ments of ANSI C57.12.28. The multi-step process includes an epoxy primer uniformly applied by cationic electro-deposition and a urethane top coat.The following additional features are all standard on self-protected type CSP® units:15. Primary protective link.16. Surge arrester.17. Secondary circuit breaker.18. Secondary breaker operating handle with emergency overload reset and overload signal light.Options1. Primary Termination• Cover-mounted high voltage porcelain bushing(s) with spin top terminal.• Side-wall mounted high voltage porcelain bushing(s) with spin top terminal (Standard on all 4800 volts and below).• Primary current limiting backup fuse.2. Secondary Termination• Low voltage porcelain bushings with NEMA spade terminals (Standard on all units 167 kVA and above).3. Primary Switching • Externally-operated tap changer.• Externally-operated dual voltage switch or internal terminal board.4. Overcurrent Protection• Internally-mounted current limiting fuse in series with protective link.5. Contact the division for voltages and dimensions on 666 through 1000 kVA.Optional Accessories 1. High voltage bushings are of two types and are made of wet process porcelain:• Speed wrench operable eyebolt bushing for cover mounting.• Spin-top bushings for either cover or side-wall mount.2. Tap changers compensate for small voltage variations along the distribution system. The externally-operated tap changer is a single-phase, five-position design for de-energized operation.3. A dual voltage switch permits use of the same transformer on distribution systems with different system voltages. 4. The CSP® protection package consists of four related components that work together to provide complete self- contained protection against surge currents, short circuits and overloads:2009 Rated Voltage Insulation Basic Impulse Ranges Class Level (kV)120-600 1.2 302160-2400 5.0 604160-4800 8.7 757200-12470 15.0 95Optional 125 kV BIL 12000 volts available.13200-14400 18.0 12519920-22900 25.0 150Optional 125 kV BIL 19920 volts available.-34400 34.5 200Type CSP Type SPower Partners Inc.Athens, GAISO 9001 Certified2009• The protective link removes an internally-faulted transformer from the primary line, maintaining service to other customers on the line not served by the faulted unit.• The MOV polymer arresters handle surges of 65,000 amperes (small block) and 100,000 amperes (large block).• Secondary circuit breakers protect against overloads and external short circuits.Standard Design Dimensions and Weights(All weights and dimensions are approxi-mate. Dimensions may change to meet the customer spec.)Single Phase, 60 HZ, OISC, 65° Rise High Voltage(Refer to Division for available tap positions and dimensions for other primary voltages.)Low Voltage 120/240 or 240/480 or 277Standard Performance levelOverhead Distribution TransformersApproximate weights and dimensions• An optional current limiting fuse sup-plements the protective link when the fault current exceeds the link’s rating.5. Stainless steel tanks and covers are available.Overall weights and dimensions are given in pounds, inches or gallons and are approximates‘A’=Overall Height, ‘B’=Overall Width, ‘C’=Overall Depth, ‘D’=Tank Diameter, ‘E’=Hanger Spacing1 Phase Type ‘S’ - Class 0A - 7200 /12470Y Primary Voltage KVA A B C D E Wgt Ship Wgt OIL Qty10 34 17 20 13.25 11.25 205 217 1115 36 17 20 13.25 11.25 236 247 1225 41 19 22 15.25 11.25 349 363 1837.5 44 22 24 17.5 11.25 489 510 2950 49 22 24 17.5 11.25 585 605 3175 49 25 27 20 23.25 850 875 40100 50 27 28 20 23.25 923 968 42167 58 38 33 24 23.25 1475 1542 78250 66 38 33 24 24 1820 1885 90333 62 42 37 24 24 2040 2110 82500 66 45 41 27 36 2850 2950 109Type ‘S’ - Class 0A - 14400 /24940Y Primary Voltage KVA A B C D E Wgt Ship Wgt OIL Qty 10 38 17 20 13.25 11.25 205 217 1115 38 17 20 13.25 11.25 245 256 1125 46 22 24 17.5 11.25 455 470 2937.5 46 22 24 17.5 11.25 505 526 2850 51 25 27 20 11.25 730 755 4175 52 25 28 20 23.25 910 936 38100 56 27 28 20 23.25 985 1025 46167 56 38 33 24 23.25 1430 1495 70250 68 38 33 24 24 1865 1930 91333 61 42 35 24 24 1970 2041 75500 72 45 39 27 36 2960 3055 121All Approximate Dimensions shown reference designs with +/- 2.5% Taps75-100 KVA1.5 - 50 KVA167 - 500 KVA ABBABBCEBDACEC BDABDAE
Most popular related searches

Contact supplier

Drop file here or browse