Power Partners - T-T - Three-Phase Specifications Sheet
Power Partners Inc.Athens, GAISO 9001 CertifiedPDL 46-203Page 1Three Phase “T-connected” Overhead DistributionTransformer2009 The Power Partners, Inc. “T-connected,” overhead distribution transformer can be used to serve most three phase applica-tions up to 500 kVA. “T-connected” trans-formers consist of two single-phase core/coil assemblies. This type of connection is also referred to as a “Scott-T” connection.“T-connected”, overhead distribution transformers can be used to serve most three-phase applications. However, Triplex designed three phase transformers are needed for some applications where large motors are the load and these motors are frequently started. Oil field pumping loads and some irrigation pumping loads should use only the triplex designs. Ratings• 30-500 kVA• 65°C rise• 60 Hertz standard, 50 Hertz optional• High Voltages: 13800 and below• Low Voltages: 208T/120, 240T x 480T, and 480T/277• Transformer BIL Ratings Transformer Primary Transformer BIL 2400T 60 kV 4160T 60 kV 4800T 60 kV 7200T 75 kV 8320T 75 kV 12000T 95 kV 12470T 95 kV 13200T 95 kV 13800T 95 kVAdvantages• Easier, more economical and cleaner installations are provided by three phase overhead transformers compared to three single-phase units.• Lighter weight and lower cost provided by “T-connected” design compared to conventional three-phase design.• Elimination of overloads from system unbalance by operating “T-connected” transformers without primary grounds.• Avoidance of transformer neutral requirement since third harmonic currents on “T-connected” transformers are negative sequence not requiring a ground path.• Reduced installation costs, lower operating cost, safer operation, minimized service disruptions and increased transformer life provided by optional CSP coordinated protection package.• The same design, manufacturing and performance advantages that are provided on PPI single phase overhead distribution transformers are incorpo-rated into “T-connected” design.Features1) Wound core with step-lap joints for increased efficiency and lower noise levels.2) Progressively wound coils with adhesive resins on insulating paper or conductors for increased short-circuit strength and thermal strength.3) Three point core-coil bracing for increased mechanical strength.4) CSP protection package available as an option for increased protection against surge currents, short circuits and overloads:• Primary protective links • Surge arresters• Secondary circuit breakers• Secondary breaker operating handle with emergency overload reset and overload signal light.5) Self-venting and resealing cover that eliminates the need for an auxiliary pressure relief device and offers increased safety through higher tank withstand.6) The paint finish process applies a durable, corrosion resistant finish to the product. The finish meets or exceeds all the performance requirements of ANSI C57.12.28. The multi-step process includes an epoxy primer uniformly applied by cationic electro- deposition and a urethane top coat.7) Cover has 13 mils minimum of polyester coating providing 15 KV dielectric insulation of tank ground parts from live parts and increasing resistance to corrosion. The cover is sloped 15° preventing water from collecting, thereby reducing the chances of corrosion and leaking.8) Tank bottom rim is three layers thick for increased durability and resistance to shipping and handling damage.Power Partners Inc.Athens, GAISO 9001 Certified2009Standard Design Dimensions and Weights (All weights and dimensions are approximate.)HV > 5000 HV < 5000BCBCA ADDOverall weights and dimensions are given in pounds, inches or gallons and are approximatesA = Overall Height, B = Overall Width, C = Overall Depth, D = Tank Diameter, E = Hanger Spacing3 Phase T - T ConnectedHigh Voltages 2400T, 4160T, 4800TKVA A B C D E* Wgt Ship Wgt OIL Qty30 49 26 25 17.5 11.25 685 720 3545 49 29 28 20 23.25 990 1035 4475 49 33 28 20 23.25 1100 1175 52112.5 57 31 30 22 36 1530 1625 62150 57 40 30 22 36 1770 1840 70225 61 37 34 24 36 2215 2303 81300 64 41 36 27 36 2750 2860 98500 78 45 42 27 3560 3650 118High Voltages 12000T, 12470T, 13200T, 13800TKVA A B C D E* Wgt Ship Wgt OIL Qty 30 54 23 25 17.5 11.25 700 735 3845 54 29 28 20 23.25 905 965 4375 54 33 28 20 23.25 1175 1225 50112.5 62 33 30 22 36 1505 1565 59150 62 40 30 22 36 1725 1780 65225 61 37 34 24 36 2285 2275 84300 69 41 36 27 36 2915 3015 100500 80 45 42 27 3815 3900 123*E is the distance between the hanger brackets.All Approximate Dimensions shown reference designs with +/- 2.5% Taps
Most popular related searches