Eaton Corporation

PowerXL DG1 Product Sheet

Next-generation drives for today’s demandsThe DG1 general-purpose drives are part of the Eaton next-generation PowerXL? series of adjustable frequency drives specifically engineered for today’s more demanding commercial and industrial applications. With an industry-leading energy efficiency algorithm, high short-circuit current rating and robust design, the DG1 offers customers increased efficiency, safety and reliability.Features• Graphic LCD keypad display• Active energy control algorithm• On-board communications:• EtherNet/IP, Modbus?/TCP• RS-485: Modbus RTU, BACnet?, MS/TP• Onboard I/O: • 8DI, 1DO• 2AI, 2AO• 2 FC relays and 1 FA relay• Real-time clock with battery backup• 5% DC link choke• Standard applications:• Standard• Multi-pump and fan control• Multi-PID• Multi-purpose• Advanced configurationPC toolBenefi ts• Dual VT and CT ratings• Easy menu navigation• Two configurable keypad soft keys• Conformal coated boards standard• EMC filter standard• Brake chopper standard (FR1–FR3)Product range• 230V to 125 hp, 310A, 90 kW• 480V to 250 hp, 310A, 160 kW• 575V to 250 hp, 250A, 160 kW• Type 1/IP21 or Type 12/IP54 packagingPowerXL SeriesDG1 general-purpose drives Eaton is a registered trademark.All other trademarks are property of their respective owners.Eaton1000 Eaton BoulevardCleveland, OH 44122United StatesEaton.com© 2014 EatonAll Rights ReservedPrinted in USAPublication No. PA040002EN / Z14668February 2014Space requirements for mounting the DG1 Series VFD and airflow Frame Size Voltage hp (CT/IH) kW ? Amperes (CT/IH)FR1 230 Vac 0.75–3 0.55–2.2 3.7–11 480 Vac 1–5 0.75–3.7 2.2–7.6 575 Vac 2–5 1.5–3.7 3.3–7.5FR2 230 Vac 4–7.5 3–5.5 12.5–25 480 Vac 7.5–15 5.5–11 12–23 575 Vac 7.5–15 5.5–11 10–18FR3 230 Vac 10–15 7.5–11 31–48 480 Vac 20–30 15–22 31–46 575 Vac 20–30 15–22 22–34FR4 230 Vac 20–30 15–22 61–88 480 Vac 40–60 30–45 61–87 575 Vac 40–60 30–45 41–62FR5 230 Vac 40–60 30–45 114–170 480 Vac 75–125 55–90 105–170 575 Vac 75–125 55–90 80–125FR6 230 Vac 75–100 55–75 211–261480 Vac 150–200 110–150 205–261575 Vac 150–200 110–160 144–208? kW ratings are at 400V / 50 Hz. The above guidelines apply unless testing has been completed to validate a design outside of these recommendations. Input ratingsDescription SpecificationInput voltage (Bin) 208–240V, 380–500V, 525–600V, –15 to 10%Input frequency (fin) 50–60 Hz (variation up to 45–66 Hz)Connection to power Once per minute or lessShort-circuit withstand rating 100 kAICOutput ratingsDescription SpecificationOutput voltage 0 to VinVT/IL overload Overload 1.1 x IL (1 min./10 min.)CT/IH overload Overload 1.5 x IH (1 min./10 min.)Initial output current 200% (2 sec./20 sec.)Output frequency 0–400 Hz (standard)Frequency resolution 0.01 HzAmbient conditionsDescription SpecificationOperating temperature –10°C (no frost) to +40°C, up to +60°C with deratingStorage temperature –40° to +70°CRelative humidity 0–95% RH, noncondensing, non-corrosiveAltitude 100% load capacity (no derating) up to 3280 ft (1000m); 1% derating for each 328 ft (100m) above 3280 ft (1000m)9843 ft (3000m) maximumCatalog numbering systemInternal Brake ChopperN = No brake chopperB = Brake chopperPower Part Options– 3 4 4D8 F B – C 21 CInput/Output Voltage Rating2 = 230V (208–240V, –15%, +10%)4 = 400V (380–500V, –15%, +10%)5 = 575V (525–600V, –15%, +10%)208–240V 380–500V 525–600VPhase Reference3 = 3~ INPUT/3~ OUTPUTInternal EMC FilterCoating of BoardsEnclosure (IP Rating)21 = IP21/Type 154 = IP54/Type 12Display OptionOutput Current Rating (CT)3D7 = 3.7A, 0.55 kW, 0.75 hp4D8 = 4.8A, 0.75 kW, 1 hp6D6 = 6.6A, 1.1 kW, 1.5 hp7D8 = 7.8A, 1.5 kW, 2 hp011 = 11A, 2.2 kW, 3 hp012 = 12.5A, 3 kW, 5 hp (VT)017 = 17.5A, 3.7 kW, 5 hp025 = 25A, 5.5 kW, 7.5 hp031 = 31A, 7.5 kW, 10 hp048 = 48A, 11 kW, 15 hp061 = 61A, 15 kW, 20 hp075 = 75A, 18.5 kW, 25 hp088 = 88A, 22 kW, 30 hp114 = 114A, 30 kW, 40 hp143 = 143A, 37 kW, 50 hp170 = 170A, 45 kW, 60 hp211 = 211A, 55 kW, 75 hp261 = 261A, 75 kW, 100 hp2D2 = 2.2A, 0.75 kW, 1 hp3D3 = 3.3A, 1.1 kW, 1.5 hp4D3 = 4.3A, 1.5 kW, 2 hp5D6 = 5.6A, 2.2 kW, 3 hp7D6 = 7.6A, 3 kW, 5 hp9D0 = 9A, 4 kW, 7.5 hp (VT)012 = 12A, 5.5 kW, 7.5 hp016 = 16A, 7.5 kW, 10 hp023 = 23A, 11 kW, 15 hp031 = 31A, 15 kW, 20 hp038 = 38A, 18 kW, 25 hp046 = 46A, 22 kW, 30 hp061 = 61A, 30 kW, 40 hp072 = 72A, 37 kW, 50 hp087 = 87A, 45 kW, 60 hp105 = 105A, 55 kW, 75 hp140 = 140A, 75 kW, 100 hp170 = 170A, 90 kW, 125 hp205 = 205A, 110 kW, 150 hp261 = 261A, 132 kW, 200 hp3D3 = 3.3A, 1.5 kW, 2 hp4D5 = 4.5A, 2.2 kW, 3 hp7D5 = 7.5A, 3.7 kW, 5 hp010 = 10A, 5.5 kW, 7.5 hp013 = 13.5A, 7.5 kW, 10 hp018 = 18A, 11 kW, 15 hp022 = 22A, 15 kW, 20 hp027 = 27A, 18 kW, 25 hp034 = 34A, 22 kW, 30 hp041 = 41A, 30 kW, 40 hp052 = 52A, 37 kW, 50 hp062 = 62A, 45 kW, 60 hp080 = 80A, 55 kW, 75 hp100 = 100A, 75 kW, 100 hp125 = 125A, 90 kW, 125 hp144 = 144A, 110 kW, 150 hp208 = 208A, 160 kW, 200 hpF = Internal EMC ?lterC = CoatedC = LCD (graphical)SeriesD G1Basic NamingD = DriveSeriesG1 = General purpose
Most popular related searches