Pre-Engineered Solution DatasheetLittelfuse.com © 2013 Littelfuse POWR-GARD® ProductsRev: 0111131 of 3LCP Fused Coordination PaneLSelective Coordination PanelFeatures/Benefits• Meets NEC® requirements• Class CC and J fuse holders have built-in open-circuit indication• Fast-acting UL Listed fuses protect against short circuits • Feed through/sub feed lugs and 84-circuit configuration available• Ground and neutral bars• Copper bus standardAdvanced Design Options• MLO, Main Circuit Breaker, or Main Fused Pullout device• Fused Class T branch circuit pullout• Spare fuse cabinet accessory (holds six spare fuses)• TVSS overvoltage protection • Any NEMA enclosure required• High amperage sub-fed branch breakers (J60A) • Unique Specifier Tool (see pg. 146) to easily identify panel configurations from tens of thousands of optionsSpecificationsVoltage Ratings 120/208, 120/240, 277/480 VACMain Bus Rating 100 A - 400 A StandardConductor Terminals 6 AWG - 300 kcmilUL Listed UL 67 Panel boards and UL 50 EnclosuresWeb ResourcesFuse Curves, sample requests, downloadable CAD drawings and other technical information: Littelfuse.com/lcpDescriptionThe Littelfuse® Coordination Panel provides a simple, time-saving solution for circuits that require selective coordination. This UL Listed product saves time and money, and increases safety by minimizing system downtime.Applications• Elevators • Hospitals• Hotel and Entertainment Industry• Amusement Parks and Stadiums Code RequirementsSystems required by the NEC® to be selectively coordinated include:• Health Care Essential Electrical Systems (NEC 517.26)• Elevators (NEC 620.62)• Emergency Systems (NEC 700.27)• Legally Required Standby Systems (NEC 701.18)• Critical Operations Power Systems (NEC 708.54) † Fuses quoted separately to meet panel specifications. Coordination for breakers >60 A depends on upstream and downstream devices. More specialized configurations are also available. Contact factory for more information.Note: The Littelfuse LPS, LPMP and LCP products are custom designed products that fall outside standard specifications. Custom Options (select one from each column)number oF CirCuitsVoLtage main deViCesneutraL ratingPaneL mountingPaneL doorFuse HoLdersbranCH CirCuit ProteCtion deViCes (1-3 PoLe)†PaneL FeedoPtionaL LugsstandardenCLosure rating2 - 42120/208 V 3P, 4 W 120/240 V 1P, 3 W 277/480 V 3P, 4 W125, 225, 400 or 600 A MLOUp to 600 A MCB or Main Fuse Pullout100% 200%Surface FlushStandard Door-in-door30 A Class CC 60 A Class J10 A- 60 A fused circuit breaker 60 A-200 A fused pullouts Sub-fed circuit breakers >60 A (not fused)Top BottomNone Sub-Fed (MLO panels) Feed-Through NEMA 1 NEMA 3R NEMA 4XTo quickly specify the LCP panel, visit Littelfuse.com/lcp and download the Specifier Tool.Pre-Engineered Solution DatasheetLittelfuse.com © 2013 Littelfuse POWR-GARD® ProductsRev: 0111132 of 3LCP Fused Coordination PaneL Selective Coordination PanelInner LineGND BusNeutral DetailNeutral Detail(6 AWG - 300 kcmil) Cu/AlIncoming Main LugsCutler HammerGHB (480 V) or BAB (208 V)Circuit Breakers(or Pullouts)LPSC001ID POWR-SafeDead front Class CC 600 VACFuseholder for use with LittelfuseCCMR, KLKR or KLDR Class CC fuses or POWR-Safe LPSJ holders for use the Class J fuses. (Fuses not included)LPSC001ID POWR-SafeDead front Class CC 600 VACFuseholder for use with LittelfuseCCMR, KLKR or KLDR Class CC fuses or POWR-Safe LPSJ holders for use the Class J fuses. (Fuses not included)Front TrimType 1 (NEMA) EnclosureFront View with Front RemovedHinged Door with Catch and LockDimensions in mm [inches]Dimensions in mm [inches]GND BusInner Line(6 AWG - 300 kcmil) Cu/AlIncoming Main LugsCutler HammerGHB (480 V) or BAB (208 V)Circuit Breakers(or Pullouts)Front TrimType 1 (NEMA) EnclosureFront View with Front RemovedHinged Door with Catch and Lock[6.00]152.4[6.00]152.4[28.00]711.2[28.00]711.2[36.00]914.4[24.00]609.6[16.50]419.1[28.00]711.2[42.00]1066.8[30.00]762[16.50]419.1[9.69]246.06[8.94]227.01[28.00]711.2[9.69]246.06[8.94]227.01Dimensions mm (inches)Standard Coordination Panel Board (up to 30 circuits)Standard Coordination Panel Board (31-42 circuits)Inner LineGND BusNeutral DetailNeutral Detail(6 AWG - 300 kcmil) Cu/AlIncoming Main LugsCutler HammerGHB (480 V) or BAB (208 V)Circuit Breakers(or Pullouts)LPSC001ID POWR-SafeDead front Class CC 600 VACFuseholder for use with LittelfuseCCMR, KLKR or KLDR Class CC fuses or POWR-Safe LPSJ holders for use the Class J fuses. (Fuses not included)LPSC001ID POWR-SafeDead front Class CC 600 VACFuseholder for use with LittelfuseCCMR, KLKR or KLDR Class CC fuses or POWR-Safe LPSJ holders for use the Class J fuses. (Fuses not included)Front TrimType 1 (NEMA) EnclosureFront View with Front RemovedHinged Door with Catch and LockDimensions in mm [inches]Dimensions in mm [inches]GND BusInner Line(6 AWG - 300 kcmil) Cu/AlIncoming Main LugsCutler HammerGHB (480 V) or BAB (208 V)Circuit Breakers(or Pullouts)Front TrimType 1 (NEMA) EnclosureFront View with Front RemovedHinged Door with Catch and Lock[6.00]152.4[6.00]152.4[28.00]711.2[28.00]711.2[36.00]914.4[24.00]609.6[16.50]419.1[28.00]711.2[42.00]1066.8[30.00]762[16.50]419.1[9.69]246.06[8.94]227.01[28.00]711.2[9.69]246.06[8.94]227.01Note: The Littelfuse LPS, LPMP and LCP products are custom designed products that fall outside standard specifications. Dimensions may change depending on panel components. More specialized configurations are also available. Contact factory for more information.Pre-Engineered Solution DatasheetLittelfuse.com © 2013 Littelfuse POWR-GARD® ProductsRev: 0111133 of 3exCeL® sPeCiFier tooL For LCP Coordination PaneLFax to Your Local Littelfuse Rep Agency or Call 1-800-TEC-FUSEJob Name: LF Quote #Panel ID:Distributor:LF Rep Agency:FUSE HOLDER BKR CKT# PH. CKT# BKR FUSE HOLDER30A CC Holder 20/1 1 A 2 **20/3** 30A CC HolderInput Values Step 3 30A CC Holder 20/1 3 B 4 **//** 30A CC Holder42 # of Panel Circuits 30A CC Holder 20/1 5 C 6 **///3** 30A CC Holder30A CC Holder 20/1 7 A 8 **20/3** 30A CC HolderStep 2 277/480V 3 Phase, 4 Wire Voltage, Phase, Wire 30A CC Holder 20/1 9 B 10 **//** 30A CC Holder60A J Holder **60/3** 11 C 12 **///3** 30A CC HolderFlush Mount Mounting 60A J Holder **//** 13 A 14 **20/3** 30A CC Holder60A J Holder **///3** 15 B 16 **//** 30A CC Holder200A Main Breaker Main Circuit Breaker 30A CC Holder 20/1 17 C 18 **///3** 30A CC Holder30A CC Holder 20/1 19 A 20 20/1 30A CC Holder200% Neutral Rating 30A CC Holder 20/1 21 B 22 20/1 30A CC Holder30A CC Holder 20/1 23 C 24 20/1 30A CC HolderBottom Feed Panel Feed 30A CC Holder 20/1 25 A 26 20/1 30A CC Holder30A CC Holder 20/1 27 B 28 20/1 30A CC HolderFeed-Through Lugs Panel Options 30A CC Holder 20/1 29 C 30 20/1 30A CC Holder30A CC Holder 20/1 31 A 32 20/1 30A CC HolderType 3R Enclosure Rating 30A CC Holder 20/1 33 B 34 20/1 30A CC Holder30A CC Holder 20/1 35 C 36 20/1 30A CC HolderDoor-in-Door Panel Door 30A CC Holder 20/1 37 A 38 20/1 30A CC Holder30A CC Holder 20/1 39 B 40 **60/2** 60A J Holder 30A CC Holder 20/1 41 C 42 **//2** 60A J Holder ***Consult Factory when specifying 2 Pole and 3 Pole Circuit Breakers *** Bill of Materials Quantity Base Part Number: LCP 42 C 1Options From above: Mounting: 1Main Circuit Breaker: 1Neutral Rating: 1Panel Feed: 1Panel Options: 1Enclosure Rating: 1Panel Door: 1Select Poles Breaker Select Amperage1 Breaker 313 Breaker 32 Breaker 1Breaker 0Breaker 0 Step 4 Breaker 0Breaker 0Breaker 030 Amp Class CC Holder 4060 Amp Class J Holder 2800-TEC FUSEFuseholder Quantities Calculate AutomaticallyFlush Mount200A Main Breaker200%Bottom FeedFeed-Through LugsType 3RDoor-in-DoorPlease configure individual feeder circuits by selecting fuse holder and breaker placement and size in Drop down menus.Littelfuse Reps Enter Breaker Quantities From Above Panel Schedule2020 www.littelfuse.com60 Step 1 LCP42C-SampleH1EM1Littelfuse DistributorPart NumbersLittelfuse Coordination Panel Circuit ScheduleLCP Fused Coordination Panel SpecifierSimplify Communication and Minimize ErrorsA Microsoft Excel® spreadsheet designed to help engineers and contractors clearly convey which technical components they would like incorporated into the Littelfuse Coordination Panel.• Easily specify technical components of your panels /system• Quickly and accurately captures desired electrical protection devices• Effectively manage each job with up-to-date information• Ensures all pertinent information is captured to prevent unnecessary delaysPanel circuit schedule identifies specific branch circuit protection devices each panel needsIdentify specific panel optionsAutomatically tabulates your Bill of Material to keep an accurate countAutomatically generates base part numberEasy identification for project trackingGet Started Today1. Download The Specifier from Littelfuse.com/lcp or request it from your Littelfuse sales representative2. Fill it out to identify what you need (See sample below)3. Send it back to Littelfuse and get a quick quote 4. Automatically generate your custom Bill of Material and base part number
Most popular related searches
Stay in the loop!
Select your areas of interest to receive industry updates.