Cummins Inc.
QSB7 Series Power Generation Generators Spec Sheet
cumminspower.com ©2013 Cummins Power Generation Inc. | S-1544m (3/13) Specification sheet Diesel Generator set QSB7 series engine 100-200 kW 60 Hz Description Cummins Power Generation commercial generator sets are fully integrated power generation systems providing optimum performance, reliability and versatility for stationary standby and prime power applications. Features Cummins® heavy-duty engine - Rugged 4-cycle, industrial diesel delivers reliable power, low emissions and fast response to load changes. Alternator - Several alternator sizes offer selectable motor starting capability with low reactance 2/3 pitch windings, low waveform distortion with non-linear loads and fault clearing short-circuit capability. Control system - The PowerCommand® 1.1 electronic control is standard equipment and provides total genset system integration including automatic remote starting/stopping, precise frequency and voltage regulation, alarm and status message display, output metering, auto-shutdown at fault detection and NFPA 110 Level 1 compliance. The optional PowerCommand 2.2 control is UL 508 Listed and provides AmpSentry™ protection. Cooling system - Standard integral set-mounted radiator system, designed and tested for rated ambient temperatures, simplifies facility design requirements for rejected heat. Enclosures - Optional weather protective and sound attenuated enclosures are available. NFPA - The genset accepts full rated load in a single step in accordance with NFPA 110 for Level 1 systems. Warranty and service - Backed by a comprehensive warranty and worldwide distributor network. Standby rating Prime rating Continuous rating Data sheets Model 60 Hz kW (kVA) 50 Hz kW (kVA) 60 Hz kW (kVA) 50 Hz kW (kVA) 60 Hz kW (kVA) 50 Hz kW (kVA) 60 Hz 50 Hz DSGAA 100 (125) 90 (113) D-3349 DSGAB 125 (156) 113 (141) D-3350 DSGAC 150 (188) 135 (169) D-3351 DSGAD 175 (219) 160 (200) D-3516 DSGAE 200 (250) 180 (225) D-3517 cumminspower.com ©2013 Cummins Power Generation Inc. | S-1544m (3/13) Generator set specifications Governor regulation class ISO 8528 Part 1 Class G3 Voltage regulation, no load to full load ± 1% Random voltage variation ± 0.5% Frequency regulation Isochronous Random frequency variation ± 0.25% Radio frequency emissions compliance Meets requirements of most industrial and commercial applications Engine specifications Bore 107 mm (4.21 in) Stroke 124.0 mm (4.88 in) Displacement 6.69 L (408 in3) Configuration Cast iron, in-line, 6 cylinder Battery capacity 1100 amps minimum at ambient temperature of -18 °C to 0 °C (0 °F to 32 °F) Battery charging alternator 100 amps Starting voltage 12 volt, negative ground Fuel system Direct injection: number 2 diesel fuel, fuel filter, automatic electric fuel shutoff Fuel filter Single element, 10 micron filtration, spin-on fuel filter with water separator Air cleaner type Dry replaceable element Lube oil filter type(s) Spin-on, full flow Standard cooling system High ambient radiator Alternator specifications Design Brushless, 4 pole, drip proof, revolving field Stator 2/3 pitch Rotor Single bearing, flexible discs Insulation system Class H Standard temperature rise 150 ºC standby at 40 °C ambient Exciter type Torque match (shunt) standard, PMG optional Phase rotation A (U), B (V), C (W) Alternator cooling Direct drive centrifugal blower fan AC waveform total harmonic distortion < 5% no load to full linear load, < 3% for any single harmonic Telephone influence factor (TIF) < 50 per NEMA MG1-22.43 Telephone harmonic factor (THF) < 3 Available voltages 60 Hz Three phase line-neutral/line-line 60 Hz Single phase line-neutral/line-line • 110/190 • 110/220 • 115/200 • 115/230 Delta • 120/208 • 120/240 Delta • 127/220 • 139/240 • 220/380 • 230/400 • 240/416 • 255/440 • 277/480 • 347/600 • 110/220 • 115/230 • 120/240 (not available with DSGAD or DSGAE) Note: Consult factory for other voltages. Generator set options and accessories Engine ? 120 V 150 W lube oil heater ? 120/240 V 1500 W coolant heater Fuel System ? 24 hour sub-base tank (dual wall) Alternator ? 105 °C rise ? 125 °C rise ? 120 V 100 W anti-condensation heater ? PMG excitation ? Single phase Exhaust system ? Heavy duty exhaust elbow ? Slip on exhaust connection Generator set ? Battery ? Battery charger ? Enclosure: aluminum, steel, weather protective or sound attenuated ? Main line circuit breaker ? Remote annunciator panel ? Spring isolators ? 2 year prime power warranty ? 2 year standby power warranty ? 5 year basic power warranty Note: Some options may not be available on all models - consult factory for availability. cumminspower.com ©2013 Cummins Power Generation Inc. | S-1544m (3/13) Control system PowerCommand 1.1 PowerCommand control is an integrated generator set control system providing voltage regulation, engine protection, operator interface and isochronous governing (optional). Major features include: • Battery monitoring and testing features and smart starting control system. • Standard PCCNet interface to devices such as remote annunciator for NFPA 110 applications. • Control boards potted for environmental protection. • Control suitable for operation in ambient temperatures from -40 °C to +70 °C (-40 °F to +158 °F) and altitudes to 5000 meters (13,000 feet). • Prototype tested; UL, CSA, and CE compliant. • InPower™ PC-based service tool available for detailed diagnostics. Operator/display panel • Manual off switch • Alpha-numeric display with pushbutton access for viewing engine and alternator data and providing setup, controls and adjustments (English or international symbols) • LED lamps indicating genset running, not in auto, common warning, common shutdown, manual run mode and remote start • Suitable for operation in ambient temperatures from -20 °C to +70 °C • Bargraph display (optional) AC protection • Over current warning and shutdown • Over and under voltage shutdown • Over and under frequency shutdown • Over excitation (loss of sensing) fault • Field overload Engine protection • Overspeed shutdown • Low oil pressure warning and shutdown • High coolant temperature warning and shutdown • Low coolant level warning or shutdown • Low coolant temperature warning • High, low and weak battery voltage warning • Fail to start (overcrank) shutdown • Fail to crank shutdown • Redundant start disconnect • Cranking lockout • Sensor failure indication • Low fuel level warning or shutdown • Fuel-in-rupture-basin warning or shutdown Alternator data • Line-to-line and line-to-neutral AC volts • 3-phase AC current • Frequency • Total kVA Engine data • DC voltage • Lube oil pressure • Coolant temperature • Engine speed Other data • Genset model data • Start attempts, starts, running hours • Fault history • RS485 Modbus® interface • Data logging and fault simulation (requires InPower service tool) Digital governing (optional) • Integrated digital electronic isochronous governor • Temperature dynamic governing Digital voltage regulation • Integrated digital electronic voltage regulator • 2-phase line-to-line sensing • Configurable torque matching Control functions • Time delay start and cooldown • Cycle cranking • PCCNet interface • (2) Configurable inputs • (2) Configurable outputs • Remote emergency stop • Glow plug control (some models) Options ? Auxiliary output relays (2) ? 120/240 V, 100 W anti-condensation heater ? Remote annunciator with (3) configurable inputs and (4) configurable outputs ? PMG alternator excitation ? PowerCommand iWatch web server for remote monitoring and alarm notification (loose) ? Auxiliary, configurable signal inputs (8) and configurable relay outputs (8) ? Digital governing ? AC output analog meters (bargraph) - Color-coded graphical display of: - 3-phase AC voltage - 3-phase current - Frequency - kVa ? Remote operator panel ? PowerCommand 2.2 control with AmpSentry protection For further detail see document S-1531. North America 1400 73rd Avenue N.E. Minneapolis, MN 55432 USA Phone 763 574 5000 Fax 763 574 5298 ©2013 Cummins Power Generation Inc. All rights reserved. Cummins Power Generation and Cummins are registered trademarks of Cummins Inc. PowerCommand, AmpSentry, InPower and “Our energy working for you.” are trademarks of Cummins Power Generation. Other company, product, or service names may be trademarks or service marks of others. Specifications are subject to change without notice. S-1544m (3/13) cumminspower.com Ratings definitions Emergency standby power (ESP): Applicable for supplying power to varying electrical load for the duration of power interruption of a reliable utility source. Emergency Standby Power (ESP) is in accordance with ISO 8528. Fuel Stop power in accordance with ISO 3046, AS 2789, DIN 6271 and BS 5514. Limited-time running power (LTP): Applicable for supplying power to a constant electrical load for limited hours. Limited Time Running Power (LTP) is in accordance with ISO 8528. Prime power (PRP): Applicable for supplying power to varying electrical load for unlimited hours. Prime Power (PRP) is in accordance with ISO 8528. Ten percent overload capability is available in accordance with ISO 3046, AS 2789, DIN 6271 and BS 5514. Base load (continuous) power (COP): Applicable for supplying power continuously to a constant electrical load for unlimited hours. Continuous Power (COP) in accordance with ISO 8528, ISO 3046, AS 2789, DIN 6271 and BS 5514. This outline drawing is for reference only. See respective model data sheet for specific model outline drawing number. Do not use for installation design Model Dim “A” mm (in.) Dim “B” mm (in.) Dim “C” mm (in.) Set Weight* dry kg (lbs) Set Weight* wet kg (lbs) DSGAA 2656 (104.6) 1100 (43.3) 1549 (61) 1180 (2602) DSGAB 2656 (104.6) 1100 (43.3) 1549 (61) 1225 (2700) DSGAC 2656 (104.6) 1100 (43.3) 1549 (61) 1263 (2784) DSGAD 2656 (104.6) 1100 (43.3) 1549 (61) 1361 (3000) DSGAE 2656 (104.6) 1100 (43.3) 1549 (61) 1361 (3000) * Note: Weights represent a set with standard features. See outline drawings for weights of other configurations. Codes and standards Codes or standards compliance may not be available with all model configurations – consult factory for availability. This generator set is designed in facilities certified to ISO 9001 and manufactured in facilities certified to ISO 9001 or ISO 9002. The generator set is available Listed to UL 2200, Stationary Engine Generator Assemblies for all 60 Hz low voltage models. The Prototype Test Support (PTS) program verifies the performance integrity of the generator set design. Cummins Power Generation products bearing the PTS symbol meet the prototype test requirements of NFPA 110 for Level 1 systems. U.S. EPA Engine certified to Stationary Emergency U.S. EPA New Source Performance Standards, 40 CFR 60 subpart IIII Tier 3 exhaust emission levels. U.S. applications must be applied per this EPA regulation. All low voltage models are CSA certified to product class 4215-01. International Building Code The generator set package is available certified for seismic application in accordance with the following International Building Code: IBC2000, IBC2003 IBC2006, IBC2009 and IBC2012. Warning: Back feed to a utility system can cause electrocution and/or property damage. Do not connect to any building’s electrical system except through an approved device or after building main switch is open. <<
/ASCII85EncodePages false
/AllowTransparency false
/AutoPositionEPSFiles true
/AutoRotatePages /None
/Binding /Left
/CalGrayProfile (Dot Gain 20%)
/CalRGBProfile (sRGB IEC61966-2.1)
/CalCMYKProfile (U.S. Web Coated \\050SWOP\\051 v2)
/sRGBProfile (sRGB IEC61966-2.1)
/CannotEmbedFontPolicy /Error
/CompatibilityLevel 1.4
/CompressObjects /Tags
/CompressPages true
/ConvertImagesToIndexed true
/PassThroughJPEGImages true
/CreateJobTicket false
/DefaultRenderingIntent /Default
/DetectBlends true
/DetectCurves 0.0000
/ColorConversionStrategy /CMYK
/DoThumbnails false
/EmbedAllFonts true
/EmbedOpenType false
/ParseICCProfilesInComments true
/EmbedJobOptions true
/DSCReportingLevel 0
/EmitDSCWarnings false
/EndPage -1
/ImageMemory 1048576
/LockDistillerParams false
/MaxSubsetPct 100
/Optimize true
/OPM 1
/ParseDSCComments true
/ParseDSCCommentsForDocInfo true
/PreserveCopyPage true
/PreserveDICMYKValues true
/PreserveEPSInfo true
/PreserveFlatness true
/PreserveHalftoneInfo false
/PreserveOPIComments true
/PreserveOverprintSettings true
/StartPage 1
/SubsetFonts true
/TransferFunctionInfo /Apply
/UCRandBGInfo /Preserve
/UsePrologue false
/ColorSettingsFile ()
/AlwaysEmbed [ true
]
/NeverEmbed [ true
]
/AntiAliasColorImages false
/CropColorImages true
/ColorImageMinResolution 300
/ColorImageMinResolutionPolicy /OK
/DownsampleColorImages true
/ColorImageDownsampleType /Bicubic
/ColorImageResolution 300
/ColorImageDepth -1
/ColorImageMinDownsampleDepth 1
/ColorImageDownsampleThreshold 1.50000
/EncodeColorImages true
/ColorImageFilter /DCTEncode
/AutoFilterColorImages true
/ColorImageAutoFilterStrategy /JPEG
/ColorACSImageDict <<
/QFactor 0.15
/HSamples [1 1 1 1] /VSamples [1 1 1 1]
>>
/ColorImageDict <<
/QFactor 0.15
/HSamples [1 1 1 1] /VSamples [1 1 1 1]
>>
/JPEG2000ColorACSImageDict <<
/TileWidth 256
/TileHeight 256
/Quality 30
>>
/JPEG2000ColorImageDict <<
/TileWidth 256
/TileHeight 256
/Quality 30
>>
/AntiAliasGrayImages false
/CropGrayImages true
/GrayImageMinResolution 300
/GrayImageMinResolutionPolicy /OK
/DownsampleGrayImages true
/GrayImageDownsampleType /Bicubic
/GrayImageResolution 300
/GrayImageDepth -1
/GrayImageMinDownsampleDepth 2
/GrayImageDownsampleThreshold 1.50000
/EncodeGrayImages true
/GrayImageFilter /DCTEncode
/AutoFilterGrayImages true
/GrayImageAutoFilterStrategy /JPEG
/GrayACSImageDict <<
/QFactor 0.15
/HSamples [1 1 1 1] /VSamples [1 1 1 1]
>>
/GrayImageDict <<
/QFactor 0.15
/HSamples [1 1 1 1] /VSamples [1 1 1 1]
>>
/JPEG2000GrayACSImageDict <<
/TileWidth 256
/TileHeight 256
/Quality 30
>>
/JPEG2000GrayImageDict <<
/TileWidth 256
/TileHeight 256
/Quality 30
>>
/AntiAliasMonoImages false
/CropMonoImages true
/MonoImageMinResolution 1200
/MonoImageMinResolutionPolicy /OK
/DownsampleMonoImages true
/MonoImageDownsampleType /Bicubic
/MonoImageResolution 1200
/MonoImageDepth -1
/MonoImageDownsampleThreshold 1.50000
/EncodeMonoImages true
/MonoImageFilter /CCITTFaxEncode
/MonoImageDict <<
/K -1
>>
/AllowPSXObjects false
/CheckCompliance [
/None
]
/PDFX1aCheck false
/PDFX3Check false
/PDFXCompliantPDFOnly false
/PDFXNoTrimBoxError true
/PDFXTrimBoxToMediaBoxOffset [
0.00000
0.00000
0.00000
0.00000
]
/PDFXSetBleedBoxToMediaBox true
/PDFXBleedBoxToTrimBoxOffset [
0.00000
0.00000
0.00000
0.00000
]
/PDFXOutputIntentProfile ()
/PDFXOutputConditionIdentifier ()
/PDFXOutputCondition ()
/PDFXRegistryName ()
/PDFXTrapped /False
/CreateJDFFile false
/Description <<
/ARA
/BGR
/CHS
/CHT
/CZE
/DAN
/DEU
/ESP
/ETI
/FRA
/GRE
/HEB
/HRV (Za stvaranje Adobe PDF dokumenata najpogodnijih za visokokvalitetni ispis prije tiskanja koristite ove postavke. Stvoreni PDF dokumenti mogu se otvoriti Acrobat i Adobe Reader 5.0 i kasnijim verzijama.)
/HUN
/ITA
/JPN
/KOR
/LTH
/LVI
/NLD (Gebruik deze instellingen om Adobe PDF-documenten te maken die zijn geoptimaliseerd voor prepress-afdrukken van hoge kwaliteit. De gemaakte PDF-documenten kunnen worden geopend met Acrobat en Adobe Reader 5.0 en hoger.)
/NOR
/POL
/PTB
/RUM
/RUS
/SKY
/SLV
/SUO
/SVE
/TUR
/UKR
/ENU (Use these settings to create Adobe PDF documents best suited for high-quality prepress printing. Created PDF documents can be opened with Acrobat and Adobe Reader 5.0 and later.)
>>
/Namespace [
(Adobe)
(Common)
(1.0)
]
/OtherNamespaces [
<<
/AsReaderSpreads false
/CropImagesToFrames true
/ErrorControl /WarnAndContinue
/FlattenerIgnoreSpreadOverrides false
/IncludeGuidesGrids false
/IncludeNonPrinting false
/IncludeSlug false
/Namespace [
(Adobe)
(InDesign)
(4.0)
]
/OmitPlacedBitmaps false
/OmitPlacedEPS false
/OmitPlacedPDF false
/SimulateOverprint /Legacy
>>
<<
/AddBleedMarks false
/AddColorBars false
/AddCropMarks false
/AddPageInfo false
/AddRegMarks false
/ConvertColors /ConvertToCMYK
/DestinationProfileName ()
/DestinationProfileSelector /DocumentCMYK
/Downsample16BitImages true
/FlattenerPreset <<
/PresetSelector /MediumResolution
>>
/FormElements false
/GenerateStructure false
/IncludeBookmarks false
/IncludeHyperlinks false
/IncludeInteractive false
/IncludeLayers false
/IncludeProfiles false
/MultimediaHandling /UseObjectSettings
/Namespace [
(Adobe)
(CreativeSuite)
(2.0)
]
/PDFXOutputIntentProfileSelector /DocumentCMYK
/PreserveEditing true
/UntaggedCMYKHandling /LeaveUntagged
/UntaggedRGBHandling /UseDocumentProfile
/UseDocumentBleed false
>>
]
>> setdistillerparams
<<
/HWResolution [2400 2400]
/PageSize [612.000 792.000]
>> setpagedevice
Most popular related searches