Serfilco International Ltd

R-103 Carbon Purification Systems Brochure

BULLETINR-103LAUG 2008CARBON PURIFICATIONSYSTEMSTHE BEST AND LOWEST COST WAY TO PURIFY BRIGHT NICKEL, ACID COPPER AND SIMILAR SOLUTIONS.• Modular design accommodates custom requirements• Eliminates down-time• Compact pre-engineered systems can be used on multiple baths thus saving in equipment cost• Systems are adaptable to almost any type of use:Continuous or intermittent, total or partial flow, with or without pre-filtering• Leakproof assembly, easy servicing• Magnetic-coupled pump• Available for use with:Bulk carbon, carbon canister or carbon cartridges• Optional pre-filterLabmasterGuardianSpace-SaverGranular Carbon Puri?cation Systems provide a simple, economical and efficient method of removing organic impurities from electroplating or other chemical solutions.Three product lines are offered: Labmaster, Space-Saver, and Guardian. The user can choose the particular model that is right for his/her application, flow rates, and the degree of solution purity required. Carbon canisters include trap filter.Connect the Carbon Purification System to your plating tank to achieve efficient organic removal. Select a system with replaceable carbon cartridges or with a chamber which has removable and refillable bulk carbon canister. The latter also accept C528PE powdered carbon cartridges which are interchangeable with the canisters.Seal-less, leak-proof pumps are rugged enough for continuous duty in systems that require total flow through the carbon chamber for effective organic removal, or they can be used at partial flow, as required. Units can be connected to a plating bath for continuous carbon treatment, then disconnected and used on another tank. Thus, one system can serve several tanks.Pre-filters, offered optionally, protect the carbon from contamination by efficient removal of solid impurities that could render the carbon inefficient.Larger and custom systems available to meet your particular application. Consult Sales Dept. for assistance.F.O.B. Northbrook, Illinois Specification subject to change without notice.R-103LPage 2CARBON PURIFICATION SYSTEMSLABMASTER© FOR CARBON CARTRIDGES WITH PRE-FILTRATIONSystems are assembled without or with clear PVC pre-filter chamber for depth cartridges as indicated and a CPVC carbon chamber with one PVC refillable canister with trap filter for granular carbon. The pump is magnetic-coupled, made of glass-filled polypropylene. Reinforced vinyl hoses, 10 ft. suction and 10 ft. discharge, CPVC and polypropylene fittings. System, mounted on a corrosion resistant base, includes -G3 pressure gauge on polypropylene gauge guard with EPDM diaphragm. * For PVC – change CL to PL in model number.Systems consist of two clear PVC chambers; the first for depth cartridges, the second for carbon cartridges. The pump is magnetic-coupled, made of glass-fi l led polypropylene. Reinforced vinyl hoses, 6 ft. suction and 6 ft. discharge with CPVC fittings included. System is mounted on a corrosion resistant base.Systems are assembled without or with CPVC or PVC pre-filter chamber for depth cartridges as indicated and a CPVC carbon chamber with three PVC refillable canisters with trap filter for granular carbon. The pump is magnetic-coupled, made of polypropylene. System, mounted on a PVC base, includes -G3A pressure gauge on polypropylene gauge guard with EPDM diaphragm and CPVC air release valve. * For PVC – change CL to PL in Model Number.1 Design flow rates may vary, but the lower value offers the maximum adsorbency and the most efficient purification for each gallon processed.2 All motors are 115/230V/1/60, 3450 RPM and include 8 ft. of 3-wire cord and plug. Motors are wired for 115V operation, unless otherwise requested. 3 (528P) canister includes 03U10U trap filter cartridge.4 Filter cartridges, carbon cartridges and bulk carbon must be ordered separately. To order: Filter cartridges, see Bulletin M-109Carbon cartridges, see Bulletin M-109 Bulk carbon, see Bulletin R-102The following systems are designed for full flow through a filter and purification chamber. These systems are usually used in conjunction with filtration systems which are sized to remove the bulk of solids from the solution being treated. Therefore, the filters offered on these systems are sized to hold only the solids which have not been picked up with the main filter.MODEL NUMBERFLOWRATE1GPMMAX.PSICARBON CHAMBERMEDIA3, 4PRE-FILTERCHAMBERCARTRIDGES4DIM. LxWxHInchesMOTOR2TEFCHPPRICE CODE NUMBERPCL10 x PCL10CC ½V APSVPCL20 x PCL20CC ½V APSVPCL30 x PCL30CC ½V APSV1 - 21 - 411/2 - 591 of CU10P1 of CU20P1 of CU30P1 of 15U10U1 of 15U20U1 of 15U30U10 x 7 x 2310 x 7 x 3310 x 7 x 431/12S-0385 BS-0386 BS-0387 BSPACE-SAVER® WITH CANISTER FOR CARBON WITHOUT OR WITH PRE-FILTRATION w/CPVCChamberw/PVCChamber*CL1(528)S 3/4V BPSV-G3CL1(528)S x PCL30 3/4V BPSV-G3 11/2 - 5 13 7 lbs. carbonfor 1 canister–3 of 15U10U 13 x 9 x 47 1/6S-0413 AS-0414 AS-0413 AAS-0414 AAGUARDIAN® WITH CANISTERS FOR CARBON WITHOUT OR WITH PRE-FILTRATION w/CPVCChamberw/PVCChamber*CL3(528P)CCS 3/4C MPLCR 1A-C.5-G3ACL3(528P)CCS x CL60(2)S 3/4C MPLCR1A-C.5-G3A 41/2 - 15 22 21 lbs. carbonfor 3 canisters–6 of 15U10U 33 x 18 x 53 1/2S-0357 FS-0358 FS-0357 FAS-0358 FAOPTIONAL ADD TOMODELPRICECODE NO.Portable - addition of two wheels For Labmaster 20" & 30" models and Space-Saver-two ?xed wheels, two swivel casters For Guardian- P- PO-0191O-0454Flow control valve on pump discharge 1/2" for Labmaster 3/4" for Space-Saver, Guardian-V1-V1O-CV12O-0984Motor starter with overload protection, push button, waterlight, 1 phase Optional 3-phase (for all systems except Labmaster)-ST4 O-MS1PO-MS3POperating voltage - under 1 HP, 3-phase motor (except Labmaster) – O-3PH50 Hz operation - Consult Sales Dept. – –@
Most popular related searches