UGA System-Technik GmbH & Co. KG
- Home
- Companies & Suppliers
- UGA System-Technik GmbH & Co. KG
- Downloads
- Rubber Press Seals
Rubber Press Seals
GPDRubber Press SealsSYSTEM-TECHNIKLLeeaaddiinngg iinn iiddeeaassLLeeaaddiinngg iinn iiddeeaassGPDRubber Press SealsGPD - plugs the gapNo matter if cable or pipe -system GPD always offers a safe solution. Rubber PressSeals can be inserted into the most varied pipe linings, diamond tipped drilled holesor entrance systems withoutany problems.For special applications please contact our technicaldepartment.???Available with a rubberthickness of 30 mm for sealing against non-pressingwater and a rubber thicknessof 60 mm for pressing water.The „one-piece design” issuitable for installation during plumbing and wiring. For installation of the GPDafter plumbing and wiring orunder difficult conditions a„divided design“ is required.All metal parts are of stainless steel.Designfor cablesRubber Press Seals GPDare used for protecting pipes and cables. They can be installed in a pipelining as well as directlyinto a diamond tippeddrilled hole.GPDs also serve as a guideand for acoustic uncoupl-ing. When tightening thehexagon nuts the rubber disc is displaced bythe press plates. Thus asecure and permanentsealing is accomplishedeven under water pressurethat can be released atany time.Application and Functionfor pipesnon-pressing waterOne-piece GPD, suitable for non-pressing water. Installation only possible duringplumbing and wiring. Max. numberof cables and diameter of groupingsee grouping table on page 6.? order no.: GPD (A)/1/(Z)x(D)(A) = outside dia. of GPD ? inside dia. of diamond tip-ped drilled hole or pipe lining(Z) = number of cables(D) = diameter of individual cablesnon-pressing waterOne-piece GPD, suitable for non-pressing water. Installation only possible duringplumbing and wiring. ? order no.: GPD (A)/1/1x(D)(A) = outside dia. of GPD ? inside dia. of diamond tip-ped drilled hole or pipe lining(D) = diameter of pipe (Øo)non-pressing waterDivided GPD, suitable for non-pressing water. Installation also possible after plumbing and wiring. ? order no.: GPD (A)/G/1/1x(D)(A) = outside dia. of GPD ? inside dia. of diamond tip-ped drilled hole or pipe lining(D) = diameter of pipe (Øo)pressing waterOne-piece GPD, suitable for pressing water. Installation only possible duringplumbing and wiring. ? order no.: GPD (A)/2/1x(D)(A) = outside dia. of GPD ? inside dia. of diamond tip-ped drilled hole or pipe lining(D) = diameter of pipe (Øo)pressing waterDivided GPD, suitable for pressing water. Installation also possible after plumbing and wiring.? order no.: GPD (A)/G/2/1x(D)(A) = outside dia. of GPD ? inside dia. of diamond tip-ped drilled hole or pipe lining(D) = diameter of pipe (Øo)non-pressing waterDivided GPD, suitable for non-pressing water. Installation also possible after plumbing and wiring. Max. numberof cables and diameter of groupingsee grouping table on page 6.? order no.: GPD (A)/G/1/(Z)x(D)(A) = outside dia. of GPD ? inside dia. of diamond tip-ped drilled hole or pipe lining(Z) = number of cables(D) = diameter of individual cablespressing waterOne-piece GPD, suitable for pressing water. Installation only possible duringplumbing and wiring. Max. numberof cables and diameter of groupingsee grouping table on page 6.? order no.: GPD (A)/2/(Z)x(D)(A) = outside dia. of GPD ? inside dia. of diamond tip-ped drilled hole or pipe lining(Z) = number of cables(D) = diameter of individual cablespressing waterDivided GPD, suitable for pressing water. Installation also possible after plumbing and wiring. Max. numberof cables and diameter of groupingsee grouping table on page 6.? order no.: GPD (A)/G/2/(Z)x(D)(A) = outside dia. of GPD ? inside dia. of diamond tip-ped drilled hole or pipe lining(Z) = number of cables(D) = diameter of individual cablesExample: GPDdiameter of cable or pipe (Øa)characteristic letter for type with connection piececharacteristic letter divided designcharacteristic number 1 for non-pressing watercharacteristic number 2 for pressing waternumber of cables or pipescharacteristic letter for type with removable insertcharacteristic letter for type with overlapping flangeoutside diameter of GPD? inside dia. of diamond tipped drilled hole or pipe liningGPD (A) / G / F / 1 oder 2 / WE oder ST / (Z) x (D)Product NomenclatureOn request rubber bore cores up to dia. 50 mm can be supplied free of charge.Plastic Pipe Lining with labyrinth glands and expansionseal coating on the outside. Available from diameter 60 to 500 mm. ? order no.: FU-K (A)/(L)(A) = inside dia. in mm (L) = wall thickness in mmStainless Steel Pipe Lining material no. 1.4301, with welded centre flange. Available from diameter 60 to 1500 mm. ? order no.: FU-VA (A)/(L)(A) = inside dia. in mm (L) = wall thickness in mmPipe Lining with integral / slip-on type flange to DIN 18 195 part 9.For sealing of waterproof sheeting(black basement lining). Made ofstainless steel. Available from diameter 60 to 1500 mm.? order no.:FU-VA (A)/F+L/T9(N)D/L(A) = inside dia. in mm (L) = wall thickness in mmFibre Cement Pipe Liningwith labyrinth grooves on the outside. Asbestos-free material. Available from diameter 80 to 1500 mm.? order no.: FU-FZ (A)/(L)(A) = inside dia. in mm (L) = wall thickness in mmFlangesuitable for sealing in front of a diamond tipped drilled hole in wall or ceiling. Available with flange gasket andfastening elements. Made of stainless steel.? order no.: GPD-F-VA/(A)(A) = inside dia. in mm Divided Flange for subsequently sealing in front of a diamond tipped drilled hole in wallor ceiling. Available with flange gasket andfastening elements. Made of stainless steel.? order no.: GPD-F-G-VA/(A)(A) = inside dia. in mmGPD Pipe Linings available inSpecial DesignSpecial concepts for project-relatedapplications as well as special sizesare available after technical clarifica-tion at short notice.Our field representatives will be gladto support you in planning.Pipe linings will be sup-plied fitting to the wallthickness of the structuralworks and are imbeddedflush into the formwork. Upon supply our plasticpipe linings are closedwith PE covers on thefront side and are thusprepared for imbeddinginto the concrete. In case of fibre cement andstainless steel pipe liningsspecial concepts for project-related applicationsare also possible, as e.g.design with integral andslip-on type flange (basement waterproofing)to DIN 18195 part 9.GeneralPipe LiningsWe provide replacements for all partswhich are impaired in their function dueto faults in the material. No replacementfor defects that are due to transport orstorage or result from faulty processing orinstallation or the effects thereof. Ourspecifications are based on the currentstate of the art.Subject to technical modifications. Due tothe amount of possible influences duringinstallation and application our specifica-tions do not release processors and usersfrom checking and testing the materialthemselves.Example: Pipe Liningwall thicknessstainless steel pipe liningplastic pipe liningpipe inside diameterfibre cement pipe liningFU- K - FZ - VA (A) / (L)Product NomenclatureDimensional TableDimensional Table Pipe Outside Diametersize in inchesnominal diametercopper pipessteel pipessteel pipes with PE coatinghard-PE pipes - 1stlongdistance heating linesCI sewage pipes with sleevesCI sewage pipes withoutsleeves (SML) and MI pipesSG ductile pressure pipesfibre cement pipesvitrified clay pipes(normal)vitrified clay pipes(reinforced)PE pipes HDPE PN 6PE pipesLDPE PNPE pipesLDPE PN 10high temp./canal/plastic sewage pipesPVC pressure pipesPN 10 / 16PP + ABSDIN 2439-41 19522DN 17671 2448 19500 28610 19831 1230 1230 8074 8074 8074 8074 19534 19532 807783/8 10 12 17,2 16 1212 15 16 16 20 16 161/2 15 18 21,3 20 20 25 20 203/4 20 22 26,9 31 90 25 25 32 25 251 25 28 33,7 38 90 32 32 40 32 3211/4 32 35 42,4 46,5 110 40 40 50 40 4011/2 40 42 42 52,5 110 50 50 50 63 50 5048,32 50 54 53 65 125 60 58 64 78±3 63 63 63 75 50 63 6357 60,3 6321/2 65 76,1 76,1 80 140 75 75 63 75 75(70) 80 78 84 75 90 75 7590(75) 105±4 903 80 80 88,9 93 160 98 90 9088,9 1681804 100 104 102 112 180 112 110 118 116 132±5 110/ 110 110 110 110108 108 119 200 125114,3 114,35 125 130 133 137 225 137 135 144 141 160±4 125/ 140 125 140 125133 139,7 144 140 1406 150 154 159 163 250 162 160 170 168 187±4 160 180 160 160 160159 168,3 173 266 180 180280200 208 219,1 224 315 212 210 222 220 242±5 262±5 160/ 225 200 225 200219 334 180 225250(225) 355 200/ 250 225225 250280250 267 273 278 400 274 274 274 270 296±6 318±6 250/ 280 250 280 250280 280315300 324 323,9 450 326 326 322 350±7 374±7 315/ 355 315 355 315355 400350 355,6 500 378 378 404±7 430±7 400 355400400 406,4 560 429 429 432 460±8 490±8 400 450450 457,2 630 486 524±8 548±8 450500 508 670 532 532 573 581±9 607±9 500560 560600 609,6 635 646 687±12 721±12 630 630700 711,2 738 750 790±15 831±15 710800 812,8 842 856 895±17 941±17 800PE pipes HDPE PN 2.5 / 3.2UGA SYSTEM-TECHNIK GmbH & Co.Technical Systems and Products for integration into buildingsHeidenheimer Str. 80-82 · 89542 HerbrechtingenPostfach 12 61 · 89539 HerbrechtingenPhone: 0049 73 24 / 96 96 - 0 · Fax: 0049 73 24 / 96 96 - 96e-mail: info@uga-systeme.de · internet: www.uga-systeme.deSealing systems and fire protection for cables and pipesGPDVariants and Special SolutionsSuitable for the distributionof electricity, gas and waterin structural and civil engineering.For diamond tipped drilledholes and pips of all dia-meters.Subsequent installation foralready laid cables and pipespossible.Gas- and watertight up to10 bars.Soundproof.Elastic bedding of cables orpipes, i.e. shocks are ab-sorbed.Basement waterproofing ac-cording to DIN 18195 part 9,integral / slip-on type flange.More efficiency due to shortinstallation time.The GPD IdeaGPD with connection piecesa combination of the rubber presstechnique and the shrink-on technique. With 1 to 8 connectionpieces suitable for cables and pipes.? order no.:GPD (A)/2/ST/(Z1)x(D1)(A) = outside dia. of GPD ? inside dia. of diamond tip-ped drilled hole or pipe lining(Z1) = number of connection pieces(D1) = inside diameter of connection piecesGPD with removable insert for changing repeated groupings, suitable for pressing water.? order no.:GPD (A)/G/2/WE(A1)/(Z)x(D)GPD with overlapping Flange available as one-piece or divided design, for non-pressing and pressingwater.One-piece design:? order no.:GPD (A)/F/(1or2)/(Z)x(D)Divided design:? order no.:GPD (A)/G/F/(1or2)/(Z)x(D)GPD rubbers are made ofEPDM. As an option, theyare also available in NBR.Rubber Press Seals are available in numerous variants and designs.Grouping tableInside ? Z=1 Z=3 Z=5 Z=9 order no. d. t. dr. hole/ cable/pipe cables/pipes cables/pipes cables/pipes divided GPD for pipe lining ? in mm ? in mm ? in mm ? in mm pressing water60 mm up to 34 up to 20 up to 12 up to 8 GPD 60/G/2/(Z)x(D)80 mm up to 45 up to 25 up to 16 up to 12 GPD 80/G/2/(Z)x(D)100 mm up to 66 up to 30 up to 22 up to 15 GPD 100/G/2/(Z)x(D)125 mm up to 87 up to 40 up to 35 up to 22 GPD 125/G/2/(Z)x(D)150 mm up to 112 up to 50 up to 40 up to 28 GPD 150/G/2/(Z)x(D)200 mm up to 162 up to 70 up to 60 up to 43 GPD 200/G/2/(Z)x(D)250 mm up to 212 up to 85 up to 70 up to 50 GPD 250/G/2/(Z)x(D)300 mm up to 260 up to ... up to up to GPD 300/G/2/(Z)x(D)350 mm up to 300 GPD 350/G/2/(Z)x(D)400 mm up to 350 GPD 400/G/2/(Z)x(D)450 mm up to 400 GPD 450/G/2/(Z)x(D)500 mm up to 450 GPD 500/G/2/(Z)x(D)GPD with Replacement InsertInside dia Z=3 Z=5 Z=9 order no. d. t. dr. hole/ cables cables cables divided GPD for pipe lining dia in mm dia in mm dia in mm pressing water100 mm up to 22 up to 17 up to 12 GPD 100/G/2/WE65/(Z)x(D)125 mm up to 30 up to 24 up to 16 GPD 125/G/2/WE85/(Z)x(D)150 mm up to 42 up to 34 up to 24 GPD 150/G/2/WE110/(Z)x(D)200 mm up to 50 up to 38 up to 27 GPD 200/G/2/WE125/(Z)x(D)(A) = outside diameter of GPD? inside diameter of diamond tipped drilled hole or pipe lining(A1) = outside diameter of replacement insert(Z) = number of cables to be sealed(D) = diameter of individual cablesOther combinations with different diameters are also possible.
