emz - Hanauer GmbH & Co KGaA
  1. Companies
  2. Products
  3. Campbell Scientific - Model 024A-L - ...

smart Sol nano - Solar Thermal Controller Brochure

Control of simple solar thermal plants with 1 collector array and 1 tank - Full graphic display for clear and logical visualization - Innovative operation concept for easy handling - Smart and time-saving wiring concept - Installation wizard for safe commissioning - Service wizard for targeted and quick customer service - Numerous operation, protective as well as monitoring and service functions - Attractive, elegant and puristic design - Various equipment levels for different applicationsCUSTOMER BENEFITDIFFERENTIAL TEMPERATURE CONTROLLER FOR SIMPLE SOLAR THERMAL PLANTS FOR DRINKING WATER HEATING AND HEATING SUPPORTSolar controllers - equipment levels B Basic A Advance S SpecialEQUIPMENT LEVELSHardwareNumber inputs for temperature sensors PT1000 3 3 3thereof switchable (analog outputs 0...10V or PWM outputs or temperature inputs) - - -thereof usable as input for pulse encoder/impeller - - -Number inputs (male connectors) for analog vortex flow sensors - - -Number triac outputs, max. 1A - for pumps, valves, boiler 1 1 1Number relay outputs - change-over contact, pot.-free, max. 1A - for pumps, valves, boiler - - -Number high current relay outputs - make contact, pot.-free, max. 15A - for immersion heater, boiler - - 1Number relays outputs - make contact, 230V output, not pot.-free, max. 1A - for boiler - 1 -Number fixed analog outputs 0…10V or PWM outputs for high-efficiency pumps 1 1 1Additional supply terminals, 2 x 85V-265V for valves, 5V and 24V for sensors - - -SD card slot for data logging, upload of hydraulic systems incl. settings - - -USB port for acces to SD card, PC, remote access and software update - - -Acoustic alarm (to be deactivated) in case of messages - - -Power reserve for real-time clock (min. 8 h) v v vEnergy-saving switch power supply with a wide-range input, 85 … 265VAC, 50/60Hz - - -Transformer power supply, 230VAC +/-10%, 50Hz v v vFull graphic TFT colour display with backlight, dimmable - - -Full graphic FSTN monochrome display with backlight v v vB A SSystemMulti-piece plastic housing v v vOperation via rotary encoder and esc button v v vMicro fuse incl. spare fuse, type 5x20mm, time-lag 2A 2A 2ALaser engraved connection diagram on the rear side of the terminal cover v v vWall mounting, installation in pump group or tank v v vProtection class IP20 v v vAmbient temperature 0 … 40°C v v vActive display area, width x height in mm 45 x 23 45 x 23 45 x 23Mesaurements, width x height x depth in mm 102 x 150 x 45 102 x 150 x 45 102 x 150 x 45Maximum number national languages 15 15 15Maximum number collector arrays 1 1 1Maximum number tanks 1 1 1Number hydraulic systems with animation of pumps, valves, back-up heating/disable recharge 1 3 3Installation wizard (free configuration, selection hydraulic system, upload from SD card) v v vPreset of configuration at OEM level v v vService wizard v v vSolar heating support v v vProtective functionsCollector emergency OFF adjustable v v vCollector cooling v v vAntifreeze v v vTank maximum temperature limitation v v vTank temperature limit cut-out v v vAnti-blocking protection v v vSoft charge - - -Tank cooling v v vOperation and efficiency functionsDifferential temperature control (Delta-T-control) v v vFixed temperature control (Fixed-T-control) v v vDisable the tank recharge with graphical display - - -Solar controllers - equipment levels B A SMonitoring and Service functionsSensor monitoring v v vMonitoring the output parameters v v vPermanent plausibility checks with detection of missing and unplausible settings v v vSensor balancing v v vDisplay free tank sensor top v v vService hour counter for outputs v v vData logging on SD card, upload hydraulic systems - - -Display of temperatures and actuators v v vMessage list with messages and warnings v v vManual Mode v v vReset of complete or parameter related factory settings v v vSolar yield calculation via pump activation with data display v v vSolar yield measurement via vortex and/or impeller with data display - - -Graphical representation of the solar yield on the display (from SD card or RAM) - - -Number of heat meters for solar yield measurement 1 1 1Display of CO²-savings - - -Optional accessory and customized adaptions on requestAssembly/operating instructions on CD, safety instructions as a leaflet v v vAssembly/operating instructions incl. safety instructions as a booklet v v vQuick Start Guide as a leaflet v v vCollector sensor PT1000, grey Silicon, operation temperature range -40 … +180°C, length 2.500mm, with ferrulesv v vTank sensor PT1000, black PVC, operation temperature range -5 … +90°C, length 2.500mm, with ferrulesv v vPower cable, black 230V, 3poles, H05VV-F 3G0,75mm, length 1.500mm, with ferrulesv v vSD card - - -Vortex flow sensors, Grundfos types VFS - - -Impeller flow sensors - - -Resistors for disable tank recharge or sensor switching, boiler sensor PT100 = 130 O / PT500 = 620 O / PT1000 = 1,3 kO- - -smart Box for remote access via internet and intranet: graphical visualization of the log-data, parameterization, software update, online operation- - -Local PC software "smart Sol analyzer" for direct connection: graphical visualization of the log-data, parameterization, software update, online operation- - -OEM personalization v v vEfficient tank charge - - -Priority/pendulum charging at multiple tanks/zone tanks with adjustable priorities and temperatures - - -Low-flow-function for low-flow-plants - - -Tube collector function v v vSelectable thermostat functions - - -Maximum number of freely selectable control functions - - -Speed control and speed limitation of the pumps v v vCollector defrosting - - -Holiday function - - -Automatic summer/winter time changeover - - -Collector minimum temperature v v vOvertravel time for outputs v v vQuick charging - - -Inversion of valve signal via menue setting - - -Anti-legionella function in conjunction with back-up heating - v vBack-up heating via different heat sources - v vDirect back-up heating via electric immersion heater - - vHeating return increase - - -Bypass in the solar circuit - - -1.1 EvaluationHeat quantitiesMeasured valuesService hoursError list0.9 EndNextYou have completedcommissioningemz-Hanauer GmbH & Co. KGaASiemensstraße 1D-92507 NabburgTelefon: +49 (0) 9433 898-0Fax: +49 (0) 9433 898-188info@emz-hanauer.comwww.emz-hanauer.comOPERATION AND VISUALIZATION - Full graphic FSTN monochrome display with backlight - Rotary encoder with Push, ESC button - Different operation levels for OEM , heating installer and end user - Self-explanatory menu and user guidance - Combination of plain text displays and symbols - Graphical representation of active functions - Different national languagesWIRING - Easily removable terminal cover for access to the terminal compartment - Laser engraved connection diagram on the rear side of the terminal cover - Generously dimensioned terminal compartment - Variable wiring and connection possibilities - Proven spring-type terminals - Convenient, intersection-free wiring - Strain relief deviceINSTALLATION AND SERVICE WIZARD - Developed in common with Regensburg University and heating trade - Solar thermal plant is ready to operate with just a few settings - By selecting the plant systems all procedures and functions are preset - Optical indications of malfunctions and errors - Possibility of a preliminary diagnosis by the enduser in case of error messages - Recommendations for the installer to eliminate malfunction or to perform maintenance workPLANT VISUALIZATION - Indication of measured values for inputs and outputs - Service hour counter for outputs - Message list - Solar yield calculation via pump activation with data displayBASASASAuxiliary heating circuitTank sensor 1, topCollector sensor 1Tank sensor 1, bottomConnection to power supplySolar circuit pump 1HYDRAULIC SYSTEMSVersion: EN 02/2015Message list
Most popular related searches