emz - Hanauer GmbH & Co KGaA
- Home
- Companies & Suppliers
- emz - Hanauer GmbH & Co KGaA
- Downloads
- smart Sol - Solar Thermal Controller ...
smart Sol - Solar Thermal Controller Brochure
Control of middle range solar thermal plants with up to 2 collector arrays or 3 tanksCUSTOMER BENEFITDIFFERENTIAL TEMPERATURE CONTROLLER FOR MIDDLE RANGE SOLAR THERMAL PLANTS FOR DRINKING WATER HEATING AND HEATING SUPPORT - 15 % higher performance of the plant by forecast of sun radiation (saving primary energy) efficient tank charge (saving pump current) - Full graphic colour display for clear and logical visualization - Innovative operation concept for easy handling - Smart and time-saving wiring concept - Installation wizard for safe commissioning - Service wizard for targeted and quick customer service - Comprehensive operation, protective as well as monitoring and service functions - Data logging for analysis and systematic plant optimization - Attractive, elegant and puristic design - Various equipment levels for different applicationsC Comfort A Access T TopHardwareNumber inputs for temperature sensors PT1000 4 4 6thereof switchable (analog outputs 0...10V or PWM outputs or temperature inputs) 1 1 1thereof usable as input for pulse encoder/impeller 2 2 2Number inputs (male connectors) for analog vortex flow sensors - 1 1Number triac outputs, max. 1A - for pumps, valves, boiler 2 2 2Number relay outputs - change-over contact, pot.-free, max. 1A - for pumps, valves, boiler 1 1 1Number high current relay outputs - make contact, pot.-free, max. 15A - for immersion heater, boiler - - -Number relays outputs - make contact, 230V output, not pot.-free, max. 1A - for boiler - - -Number fixed analog outputs 0…10V or PWM outputs for high-efficiency pumps - - 2Additional supply terminals, 2 x 85V-265V for valves, 5V and 24V for sensors - - -SD card slot for data logging, upload of hydraulic systems incl. settings - v vUSB port for acces to SD card, PC, remote access and software update - v vAcoustic alarm (to be deactivated) in case of messages v v vPower reserve for real-time clock (min. 8 h) v v vEnergy-saving switch power supply with a wide-range input, 85 … 265VAC, 50/60Hz - - -Transformer power supply, 230VAC +/-10%, 50Hz v v vFull graphic TFT colour display with backlight, dimmable v v vFull graphic FSTN monochrome display with backlight - - -EQUIPMENT LEVELSSolar controllers - equipment levels C A TSystemMulti-piece plastic housing v v vOperation via rotary encoder and esc button v v vMicro fuse incl. spare fuse, type 5x20mm, time-lag 2A 2A 2ALaser engraved connection diagram on the rear side of the terminal cover v v vWall mounting, installation in pump group or tank v v vProtection class IP20 v v vAmbient temperature 0 … 40°C v v vActive display area, width x height in mm 47 x 35 47 x 35 47 x 35Mesaurements, width x height x depth in mm 115 x 173 x 46 115 x 173 x 46 115 x 173 x 46Maximum number national languages 20 20 20Maximum number collector arrays 2 2 2Maximum number tanks 2 2 3Number hydraulic systems with animation of pumps, valves, back-up heating/disable recharge 20 20 24Installation wizard (free configuration, selection hydraulic system, upload from SD card) v v vPreset of configuration at OEM level v v vService wizard v v vSolar heating support v v vProtective functionsCollector emergency OFF adjustable v v vCollector cooling v v vAntifreeze v v vTank maximum temperature limitation v v vTank temperature limit cut-out v v vAnti-blocking protection v v vSoft charge v v vTank cooling v v vOperation and efficiency functionsDifferential temperature control (Delta-T-control) v v vFixed temperature control (Fixed-T-control) v v vDisable the tank recharge with graphical display v v vSolar controllers - equipment levels C A TMonitoring and Service functionsSensor monitoring v v vMonitoring the output parameters v v vPermanent plausibility checks with detection of missing and unplausible settings v v vSensor balancing v v vDisplay free tank sensor top v v vService hour counter for outputs v v vData logging on SD card, upload hydraulic systems - v vDisplay of temperatures and actuators v v vMessage list with messages and warnings v v vManual Mode v v vReset of complete or parameter related factory settings v v vSolar yield calculation via pump activation with data display v v vSolar yield measurement via vortex and/or impeller with data display v v vGraphical representation of the solar yield on the display (from SD card or RAM) v v vNumber of heat meters for solar yield measurement 2 2 2Display of CO²-savings v v vOptional accessory and customized adaptions on requestAssembly/operating instructions on CD, safety instructions as a leaflet v v vAssembly/operating instructions incl. safety instructions as a booklet v v vQuick Start Guide as a leaflet v v vCollector sensor PT1000, grey Silicon, operation temperature range -40 … +180°C, length 2.500mm, with ferrulesv v vTank sensor PT1000, black PVC, operation temperature range -5 … +90°C, length 2.500mm, with ferrulesv v vPower cable, black 230V, 3poles, H05VV-F 3G0,75mm, length 1.500mm, with ferrulesv v vSD card - v vVortex flow sensors, Grundfos types VFS - v vImpeller flow sensors v v vResistors for disable tank recharge or sensor switching, boiler sensor PT100 = 130 O / PT500 = 620 O / PT1000 = 1,3 kOv v vsmart Box for remote access via internet and intranet: graphical visualization of the log-data, parameterization, software update, online operation- v vLocal PC software "smart Sol analyzer" for direct connection: graphical visualization of the log-data, parameterization, software update, online operation- v vOEM personalization v v vEfficient tank charge v v vPriority/pendulum charging at multiple tanks/zone tanks with adjustable priorities and temperatures v v vLow-flow-function for low-flow-plants v v vTube collector function v v vSelectable thermostat functions v v vMaximum number of freely selectable control functions 2 2 2Speed control and speed limitation of the pumps v v vCollector defrosting v v vHoliday function v v vAutomatic summer/winter time changeover v v vCollector minimum temperature v v vOvertravel time for outputs v v vQuick charging v v vInversion of valve signal via menue setting v v vAnti-legionella function in conjunction with back-up heating v v vBack-up heating via different heat sources v v vDirect back-up heating via electric immersion heater - - -Heating return increase v v vBypass in the solar circuit v v vemz-Hanauer GmbH & Co. KGaASiemensstraße 1D-92507 NabburgTelefon: +49 (0) 9433 898-0Fax: +49 (0) 9433 898-188info@emz-hanauer.comwww.emz-hanauer.comQRCODEemz-Hanauer GmbH & Co. KGaASiemensstraße 1D-92507 NabburgTelefon: +49 (0) 9433 898-0Fax: +49 (0) 9433 898-188info@emz-hanauer.comwww.emz-hanauer.comTank sensor 2, bottomTank sensor 2, topS olar circuit pump 2Connection to power supplyCollector sensor 1Solar circuit pump 1Tank sensor 1, bottomheating boiler connection according to page 45-46OPERATION AND VISUALIZATION - Full graphic TFT colour display with backlight - Rotary encoder with Push, ESC button - Different operation levels for OEM, heating installer and end user - Self-explanatory menu and user guidance - Combination of plain text displays and symbols - Graphical representation of active functions - Different national languagesWIRING - Easily removable terminal cover for access to the terminal compartment - Laser engraved connection diagram on the rear side of the terminal cover - Generously dimensioned terminal compartment - Variable wiring and connection possibilities - Proven spring-type terminals - Convenient, intersection-free wiring - Strain relief deviceINSTALLATION AND SERVICE WIZARD - Developed in common with Regensburg University and heating trade - Solar thermal plant is ready to operate with just a few settings - Commissioning via free configuration, selection of the hydraulic system or upload from the SD card - Optical and/or acustical indications of malfunctions and errors - Possibility of a preliminary diagnosis by the enduser in case of error messages - Recommendations for the installer to eliminate malfunction or to perform maintenance workPLANT VISUALIZATION - Indication of measured values for inputs and outputs - Service hour counter for outputs - Display CO²-savings - Message list - Solar yield measurement with data display and graphical representation - Remote access plus software packages for plant monitoring and optimizationDATA INTERFACES - Data interfaces such as SD card for data logging and commissioning or USB for remote control and software updateCATCATCATCATCATCATCATCATCATCATCATCATCATCATCATCATCATCATCATCAT TT T THYDRAULIC SYSTEMSVersion: EN 02/2015
Most popular related searches
